共查询到19条相似文献,搜索用时 95 毫秒
1.
2.
文章利用循环喷淋吸收塔针对氨气和硫化氢两种恶臭气体进行化学氧化吸收处理,研究了水溶液、氧化吸收液、紫外辅助氧化吸收3种工况条件下氨气和硫化氢的吸收效率以及硫化氢的氧化途径。结果表明:紫外辅助条件下相对于水溶液吸收和氧化液吸收具有较好的吸收效果,出气口硫化氢和氨气的平均浓度分别为0.65和0.13 mg/m~3,去除效率分别为89.97%和90.71%,吸收液中硫酸根含量可达24.6 mg/L,单质硫和亚硫酸根分别为22.3和32.5 mg/L,可见紫外辅助条件下具有最好的氧化效果和吸收效果。向循环槽定量添加H_2O_2和补充浓硫酸,48 h内硫化氢的平均去除率进一步提升至91.1%。 相似文献
3.
4.
生物膜填料塔净化低浓度硫化氢恶臭气体研究 总被引:31,自引:1,他引:31
本文研究用生物膜填料塔净化低浓度硫化氢恶臭气体。实验结果表明:用城市污水处理厂污水驯化培养的脱硫菌对硫化物具有较好的降解性。用该菌液挂膜的生物膜填料塔对低浓度硫化氢恶臭气体具有较好的去除效果,最大生化去除量为190m g/l·h,控制适宜的液体喷淋量和增加气体在塔内的停留时间可提高生物膜填料塔对硫化氢的生化去除量和净化效率,同时,该塔对二氧化硫废气也有较好的净化效率。在光照有氧的条件下,硫化氢在微生物的作用下被氧化为单质硫和硫酸,但以硫酸为主。 相似文献
5.
6.
脉冲放电等离子体治理炼油厂恶臭气体研究 总被引:17,自引:0,他引:17
应用脉冲放电等离子体技术,在线板式反应器内对炼油厂恶臭气体中代表性污染物———硫化氢、乙硫醇的去除进行了试验,试验规模4~16m3·h-1 采用闸流管开关脉冲电源,其最大输出功率1kW,最大脉冲电压峰值100kV.试验考察了峰值电压、重复频率、进口浓度、处理气量、背景气体各单因素对去除率的影响.结果表明:硫化氢几乎完全去除,乙硫醇最大去除率为84%;在有正己烷背景气体存在时,乙硫醇的去除可不受低浓度背景气体影响;在高浓背景气体情况下,乙硫醇的去除率有所降低,硫化氢也有类似规律;硫化氢和乙硫醇中硫元素主要转化为二氧化硫.结合恶臭气体去除率与能量密度、进口浓度的关系,建立反应器动力学模型,获得硫化氢和乙硫醇的氧化速率常数分别为0 042和0 034L·J-1,为进一步反应器优化、放大设计及与电源匹配提供了基础数据. 相似文献
7.
介绍污水汽提(一)装置原料污水罐罐顶臭气源的情况,臭气治理方法的选择,降膜吸收工艺技术的反应机理、工艺流程及该装置应用此项技术的治理效果。讨论了恶臭气体流量、浓度的变化对处理过程的影响,吸收剂的循环量对吸收效果的影响,温度对恶臭气体流量和浓度的影响,分析了触变型催化氧化的情况。采用降膜吸收工艺技术后,该装置对H2S、NH3及甲硫醇、乙硫醚等非常恶臭的气体去除率分别为99.98%、96%、96%和96%。 相似文献
8.
低浓度硫化氢恶臭气体的生化处理研究 总被引:5,自引:1,他引:5
采用生物膜填料塔净化低浓度硫化氢恶臭气体,研究了进气负荷,液体喷淋量,气体流量和PH值等因素对生物净化低浓度硫化氢恶臭气体净化性能的影响,为下一步工业应用提供基础数据。 相似文献
9.
马恒亮 《安全.健康和环境》2014,14(11):29-32
通过对低温柴油吸收处理炼油厂酸性水罐区恶臭气体效果的探讨,将处理过程中存在的气相线频繁堵塞、制冷机组运行异常、吸收塔设计负荷小、超重力反应器运行效果不理想和测量存在较大误差等问题进行了分析,并提出了具体可行措施:定期清理恶臭气体流程管线,对废气管路所有低点进行密闭排凝;在吸收塔前路恶臭气体管线增上液环真空泵;对废气管线增加伴热保温措施;将测量元件进行位置变更;完善恶臭处理设施管理体制。 相似文献
10.
11.
废水脱氮与沼气脱硫耦联菌株的驯化和分离 总被引:5,自引:2,他引:3
在不接种污泥、接种厌氧污泥和接种好氧污泥的条件下,采用鼓泡反应器研究猪场废水脱氮与沼气脱硫耦联反应器的启动及关键微生物.试验前期(第26 d前),接种污泥反应器的脱氮脱硫率为50%~64%,而不接种污泥反应器的脱氮脱硫率只有11%~14%.到驯化结束时(第56 d),3个反应器的脱氮效率为90%左右,脱硫效率达到70%以上.结果表明,不接种污泥反应器经过一段时间驯化后也可以达到同样的脱氮脱硫效果,只是启动时间比接种污泥的反应器稍长.在反应器启动期间,于不同时段分别进行了微生物种群动态变化检测,结果显示微生物种群数量变化与3个反应器的脱氮脱硫效果变化趋势基本一致.在驯化成功的反应器中,分离筛选出氮硫去除率同时达到60%以上的菌株2株,初步鉴定为脱氮硫杆菌(Thiobacillus denitrificans)和假单胞菌属(Pseudomonas)细菌. 相似文献
12.
13.
14.
The nuisance impact of air pollutant emissions from wastewater pumping stations is a major issue of concern to China. Hydrogen sulfide and ammonia are commonly the primary odor and are important targets for removal. An alternative control technology, biofiltration, was studied. The aim of this study is to investigate the potential of unit systems packed with compost in terms of ammonia and hydrogen sulfide emissions treatment, and to establish optimal operating conditions for a full-scale conceptual design. The laboratory scale biofilter packed with compost was continuously supplied with hydrogen sulfide and ammonia gas mixtures. A volumetric load of less than 150 gH2S/(m^3.d) and 230 gNH3/(m^3.d) was applied for about fifteen weeks. Hydrogen sulfide and ammonia elimination occurred in the biofilter simultaneously. The removal efficiency, removal capacity and removal kinetics in the biofilter were studied. The hydrogen sulfide removal efficiency reached was very high above 99%, and ammonia removal efficiency was about 80%. Hydrogen sulfide was oxidized into sulphate. The ammonia oxidation products were nitrite and nitrate. Ammonia in the biofilter was mainly removed by adsorption onto the carrier material and by absorption into the water fraction of the carrier material. High percentages of hydrogen sulfide or ammonia were oxidized in the first section of the column. Through kinetics analysis, the presence of ammonia did not hinder the hydrogen sulfide removal. According to the relationship between pressure drop and gas velocity for the biofilter and Reynolds number, non-Darcy flow can be assumed to represent the flow in the medium. 相似文献
15.
16.
利用压力釜在100500 kPa 压力和303500 kPa 压力和303323K温度下,研究了 2.0323K温度下,研究了 2.0 4.9的哌嗪水溶液对二氧化碳的平衡吸收量,测试了温度和浓度对平衡吸收量的影响。co2的平衡吸收量随着浓度的增加而增加。313 K的操作温度既能保证较高的吸收量,又能保证较快的吸收速率,因此是合适的操作温度。对3.5M的PZ水溶液,在温度为368 4.9的哌嗪水溶液对二氧化碳的平衡吸收量,测试了温度和浓度对平衡吸收量的影响。co2的平衡吸收量随着浓度的增加而增加。313 K的操作温度既能保证较高的吸收量,又能保证较快的吸收速率,因此是合适的操作温度。对3.5M的PZ水溶液,在温度为368383K的条件下进行再生。温度为368 K时,再生效率为82.13%,再生过程需 55 min,而升温至383 K后再生效率大幅提升至 95.98%,再生时间迅速降为41 min。考虑到再生的时间、效率及能耗等因素,在 378 K下进行再生相对适宜。在373K 的操作温度下进行多次再生实验,PZ 水溶液经过10个周期的实验后9.76%,吸收容量与新鲜溶液相比只损失了并且只降低了1.0个pH,这也说明,PZ水溶液再生效率及连续再生能力较为突出。 相似文献
17.
利用低温等离子体在降解污染过程中产生的副产物臭氧,开展了低温等离子体-臭氧催化氧化耦合工艺同时去除硫化氢和臭氧研究,考察了催化剂粒径、空床停留时间、催化反应温度、等离子体输入功率等工艺参数对硫化氢降解和副产物臭氧浓度的影响。研究发现:臭氧需求因子(Df)与催化床层出口的硫化氢与臭氧浓度之间有一定的对应关系,ln(Df)介于3~4时,尾气中硫化氢和臭氧的浓度可分别维持在5.0×10-6,3×10-6m3/m3以下;等离子体能量密度SIE/Cin与ln(Df)值成明显的正相关:ln(Df)=30.924SIE/Cin-3.5622。对于进气浓度(Cin)和气体流速(Q)皆已知的硫化氢废气,通过调控输入功率(P)来调控SIE使ln(Df)值在3~4,可使耦合工艺具有最佳的去除效果,实现硫化氢和臭氧最佳去除。 相似文献
18.
19.
目的电气设备铜材因遭受含硫化氢环境腐蚀的影响,致使其性能下降,并给电气设备的安全运行埋下安全隐患。为保证电气设备在现场服役环境中的安全可靠性,需对铜材在该环境中的寿命进行预测。方法利用失重法研究电气设备用铜材在现场环境和室内外硫化氢加速环境下的腐蚀动力学规律,通过灰色关联度分析方法探讨两种环境条件下的关联性,并建立铜材在现场服役环境中的寿命预测模型。结果在现场和室内硫化氢环境下,铜材腐蚀动力规律遵循幂函数定律;两种环境的灰色关联系数为0.72,相关性良好;铜材的腐蚀寿命模型为T_(现场)=0.74T_(加速)~(2.16)。结论利用室内硫化氢加速腐蚀试验可以对电气设备用铜材在现场环境中的腐蚀状态和腐蚀寿命进行预测。 相似文献