首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Performance comparison of structural stormwater best management practices.   总被引:2,自引:0,他引:2  
This paper describes a method for comparing the pollutant removal of a number of structural stormwater treatment devices, commonly referred to as best management practices (BMPs). Historically, the pollutant removal ability of a BMP has been expressed as a percent reduction in concentration or load. Unfortunately, the calculated percent reduction in pollutant concentration is strongly affected by the influent concentration, with the calculated reduction generally being much lower when the event mean concentrations (EMCs) in the untreated runoff from the test watershed are low. The objective of the proposed methodology is to eliminate this problem by predicting BMP performance for an arbitrary influent concentration, so that BMPs evaluated in different watersheds can be compared as if the influent quality at all sites were the same. This method allows BMPs to be compared based on the quality of effluent produced and the mass reduction. The proposed method uses linear regression as the primary tool to compute the expected effluent concentration from a BMP, given a specific influent concentration of interest and was developed using data collected in the California Department of Transportation BMP Retrofit Pilot Program. This technique reveals that for media filters, the concentration of sediment and other particle-associated pollutants in treated runoff is generally unrelated to influent quality and is relatively constant. Wet basins with large permanent pool volumes also have effluent concentrations that are constant for most constituents and unrelated to influent concentrations. In these situations, the "percent reduction" in a pollutant EMC is not an inherent characteristic of the BMP, but a function of the influent EMC, because the quality of effluent produced is constant. Predicting the effluent quality of several types of conventional BMPs based on a common influent concentration allows an objective comparison of their performance and the selection of a BMP that addresses specific constituents of concern.  相似文献   

2.
Ozone disintegration of excess biomass and application to nitrogen removal.   总被引:1,自引:0,他引:1  
A pilot-scale facility integrated with an ozonation unit was built to investigate the feasibility of using ozone-disintegration byproducts of wasted biomass as a carbon source for denitrification. Ozonation of biomass resulted in mass reduction by mineralization as well as by ozone-disintegrated biosolids recycling. Approximately 50% of wasted solids were recovered as available organic matter (ozonolysate), which included nonsettleable microparticles and soluble fractions. Microparticles were observed in abundance at relatively low levels of ozone doses, while soluble fractions became dominant at higher levels of ozone doses in ozone-disintegrated organics. Batch denitrification experiments showed that the ozonolysate could be used as a carbon source with a maximum denitrification rate of 3.66 mg nitrogen (N)/g volatile suspended solids (VSS) x h. Ozonolysate was also proven to enhance total nitrogen removal efficiency in the pilot-scale treatment facility. An optimal chemical oxygen demand (COD)-to-nitrogen ratio for complete denitrification was estimated as 5.13 g COD/g N. The nitrogen-removal performance of the modified intermittently decanted extended aeration process dependent on an external carbon supply could be described as a function of solids retention time.  相似文献   

3.
A pilot submerged membrane bioreactor coupled with biological nutrient removal was used to treat the primary effluent at a municipal wastewater treatment plant. Long-term experiments were conducted by varying hydraulic retention time from 6 to 8 hours and solids retention time from 20 to 50 days, respectively. The performance was assessed by monitoring key wastewater parameters, including chemical oxygen demand (COD), nitrogen, and phosphorus concentration in individual anoxic, anaerobic, aerobic, and membrane separation zones. Results showed that the tested system can consistently achieve COD, nitrogen, and phosphorus removal efficiencies at 80 to 98%, 70 to 93%, and 89 to 98%, respectively. Effluent COD remained low as a result of efficient solid retention, even though there was great variation in influent quality. However, total nitrogen increased proportionally with influent concentration. At a 50-day solids retention time, higher COD and nitrogen oxides specific utilization rates in the anoxic zone resulted in a high production of nitrogen oxides in the subsequent aerobic zone.  相似文献   

4.
The goal of this study was to determine the removal efficiencies of chromium, copper, lead, nickel, and zinc from raw wastewater by chemically enhanced primary treatment (CEPT) and to attain a total suspended solids removal goal of 80%. Operating parameters and chemical doses were optimized by bench-scale tests. Locally obtained raw wastewater samples were spiked with heavy metal solutions to obtain representative concentrations of metals in wastewater. Jar tests were conducted to compare the metals removal efficiencies of the chemical treatment options using ferric chloride, alum, and anionic polymer. The results obtained were compared with those from other studies. It was concluded that CEPT using ferric chloride and anionic polymer is more effective than CEPT using alum for metals removal. The CEPT dosing of 40 mg/L ferric chloride and 0.5 mg/L polymer enhanced heavy metals removal efficiencies by over 200% for chromium, copper, zinc, and nickel and 475% for lead, compared with traditional primary treatment. Efficient metals capture during CEPT can result in increased allowable headworks loadings or lower metal levels in the outfall.  相似文献   

5.
The effect of sequencing batch reactor operation on presence and concentration of tetracycline-resistant organisms was studied as a function of organic loading rate (OLR) and solids retention time (SRT), with and without supplemented influent tetracycline. These effects were evaluated using bacterial counts, bacterial production, system growth rate, and percent resistance. These evaluation parameters were applied to both intermediate resistant and resistant heterotrophs, enterics, and lactose fermenters. Tetracycline intermediate resistant and resistant bacteria are defined as the survival of colonies on agar with 5 and 20 mg/L tetracycline, respectively. Based on these studies, increases in influent tetracycline concentration and OLR resulted in amplification of tetracycline resistance. Decreases in SRT also resulted in amplification of tetracycline resistance.  相似文献   

6.
A circular gravity-phase separator using coalescing medium with cross flow was developed to remove oil and suspended solids from wastewaters. Coalescence medium in the form of inclined plates promotes rising of oil droplets through coalescence and settling of solid particles through coagulation. It exhibits 22.67% higher removal of total suspended solids (TSS) compared to separators without coalescing medium. Moreover, it removed more than 70% of oil compared to conventional American Petroleum Institute separators, which exhibit an average of 33% oil removal. The flowrate required to attain an effluent oil concentration of 10 mg/L (Q(o10)) at different influent oil concentrations (C(io)) can be represented by Q(o10) x 10(-5) = -0.0012C(io) + 0.352. The flowrate required to attain an effluent TSS concentration of 50 mg/L (Q(ss50)) at different influent TSS concentrations (C(iss)) can be represented by Q(ss50) x 10(-5) = 1.0 x 10(6) C(iss)(-2.9576). The smallest removable solid particle size was 4.87 microm.  相似文献   

7.
A membrane enhanced biological phosphorus removal (MEBPR) process was studied to determine the impact of hydraulic retention time (HRT) and solids retention time (SRT) on the removal of chemical oxygen demand (COD), nitrogen, and phosphorus from municipal wastewater. The MEBPR process was capable of delivering complete nitrification independent of the prevailing operating conditions, whereas a significant improvement in COD removal efficiency was observed at longer SRTs. In the absence of carbon-limiting conditions, the MEBPR process was able to achieve low phosphorus concentrations in the effluent at increasingly higher hydraulic loads, with the lowest HRT being 5 hours. The MEBPR process was also able to maintain optimal phosphorus removal when the SRT was increased from 12 to 20 days. However, at higher suspended solids concentrations, a substantial increase was observed in carbon utilization per unit mass of phosphorus removed from the influent. These results offer critical insights to the application of membrane technology for biological nutrient removal systems.  相似文献   

8.
The effect of an oxidative co-treatment on anaerobic digestion of a mixture of primary and waste activated sludge was investigated. The oxidant used in this study was hydrogen peroxide (H2O2). A maximum improvement in solid destruction of 15.2% was achieved in the overall process, with a dosage of 2.0 g H2O2/g influent volatile suspended solids (VSS(influent)). All configurations operated at this dosage also showed statistically significant increases in solids removal. A statistically significant enhancement in overall solids destruction was observed for the lower oxidant dosage (0.5 H2O2/g VSS(influent)). Surprisingly, for 1.0 g H2O2/g VSS(influent), only one of the three configurations involving oxidative co-treatment showed significant increases in solids destruction. Special attention was paid to the performance of this process relative to fecal coliforms destruction. Class A biosolids were obtained for all the different hydrogen peroxide dosages used when oxidative co-treatment is combined with a two-stage anaerobic digestion process.  相似文献   

9.
The objective of this research was to modify an extended detention basin to provide batch treatment of stormwater runoff. An automated valve/controller was developed and placed on the outlet of a detention basin in Austin, Texas, which allowed the water quality volume to be retained in the basin for a preset length of time. The influent and effluent of the modified basin were monitored for total suspended solids (TSS), nutrients, chemical oxygen demand (COD), and total and dissolved metals. Statistically significant removal of total metals, COD, total nitrogen, total phosphorus, and TSS was observed, with a discharge event mean TSS concentration of 7 mg/L and a TSS removal efficiency of 91%. The modified basin has substantially better pollutant removal than conventional extended detention basins and is comparable with that of Austin sand filters, which are a common structural stormwater treatment system in the Austin area. The valve also can be used to isolate hazardous material spills.  相似文献   

10.
In this study, a cascade of anoxic and oxic fluidized bed biofilm reactors system was carried out to treat synthetic municipal wastewater. The parameters of the influent flow rates and C/N ratios were discussed. System performance was acceptable for chemical oxygen demand (COD), ammonia, and total nitrogen removal. A decrease of ammonia and total nitrogen removal efficiencies, however, was observed when the influent flow rates increased to 5.04 and 6.12 1 h(-1). Total nitrogen removal decreased at the influent C/N ratio of 3:1. The measured ratios of COD reduction in the anoxic column to nitrogen removal through nitrification-denitrification were 3.7, 3.5, 3.3, and 3.1 g COD/g(-1) N on average when the influent C/N ratios changed from 6:1 to 3:1. The observed sludge yield (Yobs) was 0.169 g VSS g COD(-1) because of perfect denitrification in the anoxic column and the relatively long solids retention time.  相似文献   

11.
采用厌氧 缺氧SBR反应器对以硝酸盐作为电子受体的反硝化除磷过程进行了研究。结果表明 ,反硝化聚磷菌完全可以在厌氧 缺氧交替运行条件下得到富集。稳定运行的厌氧 缺氧SBR反应器的反硝化除磷效率 >90 % ,出水磷浓度 <1mg L。进水COD浓度对反硝化除磷的效率影响很大 ,在COD浓度 <180mg L时 ,进水COD浓度越高 ,除磷效率也就越高。较高浓度的进水COD浓度将导致有剩余的COD进入缺氧段 ,对反硝化吸磷构成不利影响。污泥龄为 16d时 ,厌氧 缺氧SBR反应器取得稳定和理想的反硝化除磷效果。污泥龄减少到 8d ,由于反硝化聚磷菌的流失导致反硝化除磷效率的下降。当污泥龄恢复到 16d时 ,经过一段时间的运行 ,反硝化聚磷菌重新得到富集 ,除磷效率恢复到 90 %以上。  相似文献   

12.
The seasonal treatment efficiency of a pilot-scale constructed wetland system located outdoors in a semi-arid, temperate climate was evaluated for graywater in a comprehensive, 1-year study. The system consisted of two wetland beds in series--a free water surface bed followed by a subsurface flow bed. Water quality monitoring evaluated organics, solids, nutrients, microbials, and surfactants. The results showed that the wetland substantially reduced graywater constituents during fall, spring, and summer, including biochemical oxygen demand (BOD) (92%), total nitrogen (85%), total phosphorus (78%), total suspended solids (TSS) (73%), linear alkylbenzene sulfonate (LAS) surfactants (94%), and E. coli (1.7 orders of magnitude). Except for TSS, lower removals of graywater constituents were noted in winter--BOD (78%), total nitrogen (64%), total phosphorus (65%), LAS (87%), and E. coli (1.0 order), indicating that, although wetland treatment slowed during the winter, the system remained active, even when the average water temperature was 5.2 +/- 4.5 degrees C.  相似文献   

13.
To use the results of kinetic tests to predict effluent concentrations of specific contaminants in activated sludge systems, the fraction of the biomass that has an ability to degrade the test compound (i.e., competent biomass) must be estimated. A calibration procedure was developed to assess the competent biomass concentration because the chemical oxygen demand (COD) fraction tended to underestimate the degrading fraction for three of the four test compounds. Acetone, for instance, had a measured influent COD fraction of 0.08%, and the actual competent fraction was estimated to be 2.3%, based on the model calibration. Once the competent biomass fraction in the mixed liquor was determined, the extant kinetic parameters were subsequently used to predict activated sludge system performance. Predicted effluent concentrations were within 2, 5, and 16% of the average measured concentrations for acetone, linear alkylbenzene sulfonate, and furfural, respectively. Day-to-day predictions for these compounds were less accurate, possibly because of the non-steady-state nature of the activated sludge systems studied. The difference between the fraction of the influent COD contributed by the target compounds and the competent biomass fraction in the mixed liquor was found to be more significant when the target compound contributed less than 1% of the influent organic matter. The chemical structure of the target compound and chemical composition of the influent likely had an effect on the resulting competent biomass concentration. The total maximum growth rate, microX, was observed to be independent of the influent concentration of acetone and furfural, thus suggesting that the competent biomass concentration for these compounds was not affected by the changes in their influent concentrations. Consequently, a majority of competent biomass growth resulted from the degradation of other substrates, resulting in a competent biomass concentration significantly higher than predicted based on the influent COD fraction contributed by the test compound.  相似文献   

14.
Anaerobically digested swine manure (ADSM) generally contains high concentrations of zinc (Zn) and copper (Cu). These metals levels exceed the land application regulations of municipal biosolids of many European countries and are on the borderline of exceptional quality in the U.S. Environmental Protection Agency (U.S. EPA) 40 CFR part 503 standards. From this perspective, a series of batch tests were conducted to evaluate the feasibility of bioleaching of Zn and Cu from ADSM so that the produced biosolids could safely be applied to land. The effect of different substrate levels (sulfur) and total solids content (as high as 9%) on metal solubilization was investigated. The results showed that metal solubilization efficiency for both Zn and Cu declined significantly with an increase in total solids from 3 to 6% and then to 9% at the same substrate level. Metal solubilization increased proportionately with increases in substrate concentration up to 6% of total solids content. However, at 9% total solids content, metal solubilization was insignificant at all substrate levels tested. At a 6% total solids level and 10 000 mg/L of substrate, 94% of Zn and 72% of Cu were solubilized. Bioleaching was also found to be effective in destruction of pathogens with approximately 2.5 log-scale reduction. The residual biosolid was found to meet the Class A biosolids standands of U.S. EPA 40 CFR part 503.  相似文献   

15.
First flush in a combined sewer system   总被引:1,自引:0,他引:1  
Pollutant first flush was examined in an urban catchment with area of 12.7 ha and drained by a combined sewer system located in northern Italy. A total of 23 rainfall-runoff events were monitored and 281 samples were analyzed. The selected quality parameters were biochemical oxygen demand, chemical oxygen demand, suspended solids, settleable solids, total phosphorus, total nitrogen, ammonium nitrogen, lead, and zinc, specific conductivity and hydrocarbons. A subset of representative storms was selected for first flush analysis. The catchment presented a strong first flush for almost all storms and most constituents. The analysis shows that treating the maximum amount of the early part of the runoff is a better strategy than treating a constant flow rate. Best management practices that can treat or store the first runoff are favored in this kind of system for these water quality parameters.  相似文献   

16.
Co-produced water from the oil and gas industry accounts for a significant waste stream in the United States. This "produced water" is characterized by saline water containing a variety of pollutants, including water soluble and immiscible organics and many inorganic species. To reuse produced water, removal of both the inorganic dissolved solids and organic compounds is necessary. In this research, the effectiveness of a pretreatment system consisting of surfactant modified zeolite (SMZ) adsorption followed by a membrane bioreactor (MBR) was evaluated for simultaneous removal of carboxylates and hazardous substances, such as benzene, toluene, ethylbenzene, and xylenes (BTEX) from saline-produced water. A laboratory-scale MBR, operated at a 9.6-hour hydraulic residence time, degraded 92% of the carboxylates present in synthetic produced water. When BTEX was introduced simultaneously to the MBR system with the carboxylates, the system achieved 80 to 95% removal of BTEX via biodegradation. These results suggest that simultaneous biodegradation of both BTEX and carboxylate constituents found in produced water is possible. A field test conducted at a produced water disposal facility in Farmington, New Mexico confirmed the laboratory-scale results for the MBR and demonstrated enhanced removal of BTEX using a treatment train consisting of SMZ columns followed by the MBR. While most of the BTEX constituents of the produced water adsorbed onto the SMZ adsorption system, approximately 95% of the BTEX that penetrated the SMZ and entered the MBR was biodegraded in the MBR. Removal rates of acetate (influent concentrations of 120 to 170 mg/L) ranged from 91 to 100%, and total organic carbon (influent concentrations as high as 580 mg/L) ranged from 74 to 92%, respectively. Organic removal in the MBR was accomplished at a low biomass concentration of 1 g/L throughout the field trial. While the transmembrane pressure during the laboratory-scale tests was well-controlled, it rose substantially during the field test, where no pH control was implemented. The results suggest that pretreatment with an SMZ/MBR system can provide substantial removal of organic compounds present in produced water, a necessary first step for many water-reuse applications.  相似文献   

17.
高基质浓度下厌氧氨氧化反应器的启动过程   总被引:2,自引:0,他引:2  
李祥  黄勇  袁怡 《环境工程学报》2010,4(8):1771-1775
采用3套厌氧序批式生物膜反应器,研究了高基质浓度对厌氧氨氧化反应器启动过程的影响。经过50 d左右培养,3个反应器氮容积去除负荷均达到0.23 kg N/(m3.d)。但是随着氮容积负荷的提高,反应器内pH也随之升高,最终超过了厌氧氨氧化菌最适生长条件,3个反应器脱氮效果逐渐下降。然后分别通过降低浓度、延长水力停留时间的方式对其脱氮效能进行恢复性研究。结果表明高基质浓度不利于厌氧氨氧化反应器脱氮能力的增强。采用低基质浓度的方式提高反应器氮容积去除负荷时,脱氮效能不仅得到了恢复,而且能够提高到0.45 kg N/(m3.d)。说明低基质难度比高基质浓度更有利于厌氧氨氧化脱氮效能的提高。  相似文献   

18.
In a storm sewer system, the catch basin is the interface between surface runoff and the sewer. Responding to the need to improve the quality of stormwater from urban areas and transportation facilities, and spurred by Phase I and II Stormwater Rules from the U.S. Environmental Protection Agency, several companies market catch basin inserts as best management practices for urban water quality management. However, little data have been collected under controlled tests that indicate the pollutant removal efficiency of these inserts when the inflow is near what can be expected to occur in the field. A stormwater simulator was constructed to test inserts under controlled and replicable conditions. The inserts were tested for removal efficiency of total suspended solids (TSS) and total petroleum hydrocarbons (TPH) at an inflow rate of 757 to 814 L/min, with influent pollutant concentrations of 225 mg/L TSS and 30 mg/L TPH. These conditions are similar to stormwater runoff from small commercial sites in the southeastern United States. Results from the tests indicate that at the test flowrate and pollutant concentration, average TSS removal efficiencies ranged from 11 to 42% and, for TPH, the removal efficiency ranged from 10 to 19%.  相似文献   

19.
The microwave-enhanced advanced oxidation process was used to treat fish silage for nutrient release and solids reduction prior to its use as a fertilizer for greenhouse operations. Fifteen sets of experiments with varying hydrogen peroxide dosages and treatment temperatures were conducted to evaluate the effectiveness of the process on the solubilization of fertilizer constituents. It was found that up to 26% of total Kjeldahl nitrogen could be released as ammonia with 6% hydrogen peroxide dosage at 170°C. An increase of nitrate/nitrite concentration was observed with higher hydrogen peroxide dosage and higher microwave temperature; the highest concentration of 10.2 mg L? 1 nitrates/nitrites was achieved at at 170°C and 6% H2O2 dosage. Up to 20 ± 9.5% of total chemical oxygen demand was reduced at temperatures between 120 and 170°C. Large quantities of volatile fatty acids were generated at lower temperatures, corresponding to an increase in soluble chemical oxygen demand, but not at higher temperatures. The treatment of fish silage using the microwave-enhanced advanced oxidation process appears to be promising.  相似文献   

20.
The removal of polycyclic aromatic hydrocarbons (PAHs) from soil using water as flushing agent is relatively ineffective due to their low aqueous solubility. However, addition of cyclodextrin (CD) in washing solutions has been shown to increase the removal efficiency several times. Herein are investigated the effectiveness of cyclodextrin to remove PAH occurring in industrially aged-contaminated soil. Beta-cyclodextrin (BCD), hydroxypropyl-beta-cyclodextrin (HPCD) and methyl-beta-cyclodextrin (MCD) solutions were used for soil flushing in column test to evaluate some influent parameters that can significantly increase the removal efficiency. The process parameters chosen were CD concentration, ratio of washing solution volume to soil weight, and temperature of washing solution. These parameters were found to have a significant and almost linear effect on PAH removal from the contaminated soil, except the temperature where no significant enhancement in PAH extraction was observed for temperature range from 5 to 35 degrees C. The PAHs extraction enhancement factor compared to water was about 200.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号