首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

2.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

3.
Concentrations of 17 toxic 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) have been determined in pooled samples of breast milk from 15 mothers living in two residential areas (Tarragona downtown and an industrial area) in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (southern Catalonia, Spain). PCDD/Fs in human milk samples ranged between 5.9 and 17.1 pg I-TEQ/g fat (162-498 pg I-TEQ/l), with a mean value of 11.8 pg I-TEQ/g fat (310.8 pg I-TEQ/l). The percentages of fat ranged between 1.53 and 3.52. Although PCDD/F levels in milk from mothers living in the industrial area were found to be slightly higher than those observed in women living Tarragona downtown, most differences did not reach the level of statistical significance. In general terms, PCDD/F concentrations in human milk (pooled) samples of mothers living in the area of Tarragona are similar or lower than those previously reported for most industrialized countries.  相似文献   

4.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

5.
In this study, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) in breast milk from mothers living in the vicinity of a new hazardous waste incinerator (HWI) were determined. Monitoring was performed after three years of regular operations in the facility and the present results were compared with baseline concentrations obtained in a pre-operational program. PCDD/PCDF levels were determined by HRGC/HRMS in 15 samples. In the present study, PCDD/PCDF concentrations ranged from 4.9 to 39.9 pg I-TEQ/g fat (5.1-46.8 pg WHO-TEQ/g fat), with a median value of 7.7 pg I-TEQ/g fat (9.1 pg WHO-TEQ/g fat). In the baseline survey, PCDD/PCDF concentrations ranged between 5.9 and 17.1 pg I-TEQ/g fat, with a median value of 11.7 pg I-TEQ/g fat. In relation to this, a percentage of reduction of 34.2% was noted. This decrease is in agreement with the relevant reduction found in the dietary intake of PCDD/PCDFs between both surveys. The results of the present study, as well as other recent environmental and biological data, indicate that living in the vicinity of this HWI should not mean additional health risks due to PCDD/PCDFs for the general population.  相似文献   

6.
Liu HM  Lu SY  Buekens AG  Chen T  Li XD  Yan JH  Ma XJ  Cen KF 《Chemosphere》2012,86(3):300-307
In order to determine the baseline contamination by polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in different areas in China, prior to the construction of municipal solid waste incinerators (MSWIs), a total of 32 representative soil samples was collected near 16 incinerators and analyzed for their PCDD/F concentrations. The PCDD/F baseline concentrations in the soil samples ranged from 0.32 to 11.4 ng I-TEQ kg−1 (dry matter), with average and median value of 2.73 and 2.24 ng I-TEQ kg−1 (dry matter), respectively, and a span between maximum and minimum recorded value of 36. The PCDD homologues predominated in 26 out of 32 soil samples, with the ratio (PCDDs)/(PCDFs) ranging from 1.1 to 164; however in the other 6 samples, PCDF homologues were larger, with the same ratio varying from 0.04 to 0.8. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) were used to examine PCDD/F amount and profile in these soil samples, and their possible associations with known emission sources: in this process 6 really distinct isomer fingerprints were identified. Background PCDD/F levels and profiles were comparable to those found in soils from China and other countries and indicate a rather low baseline PCDD/F contamination of soils. The present data provide the tools for future assessment of a possible impact of these MSWIs.  相似文献   

7.
Polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) levels were determined in adipose tissue of 15 autopsied subjects who at the time of death had lived in the city of Tarragona (Catalonia, Spain) and surroundings during at least the last 10 years. PCDD/F concentrations ranged between 13.37 and 69.37 ng I-TEQ/kg fat, with mean and median values of 30.98 and 26.30 ng I-TEQ/kg fat, respectively. PCDD/F concentrations were higher (p < 0.01) in women (mean value: 44.95 ng I-TEQ/kg fat) than in men (mean value: 24.00 ng I-TEQ/kg fat). Although individuals living in industrial areas showed higher PCDD/F levels than those living Tarragona downtown the difference was not statistically significant. When Principal Component Analysis was applied to the concentrations of PCDD/Fs found in the 15 adipose tissue samples together with those found in 20 blood samples collected in a previous study, a single two-dimensional model was obtained, which would explain 62.9% of the variance in the data. The PCDD/F concentrations in adipose tissue found in the current study are of the same order of magnitude than those reported for most industrialized countries.  相似文献   

8.
The aim of this study was to measure, 6 years after regular operations, the concentrations of a number of organic substances in blood and urine of 19 workers employed at a hazardous waste incinerator (HWI) in Spain, and to establish the temporal variation with respect to baseline data and previously performed surveys. This facility was the first, and so far the only HWI in that country. The levels of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB 28, 52, 101, 138, 153 and 180) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were analyzed in six composite plasma samples, while concentrations of di-, tri, and pentachlorophenols, as well those of 1-hydroxypyrene were measured in the urine of these workers. The current mean PCDD/F concentration, 10.4 ng I-TEQ/kg lipid, was significantly lower than that found in the baseline survey, 26.7 ng I-TEQ/kg lipid and similar to that found in the previous (2004) study (7.7 ng I-TEQ/kg lipid). PCDD/F levels in plasma were similar or even lower than those recently reported for various non-exposed populations. For the remaining analyzed substances in plasma and urine, there was not any significant increase in comparison with the levels found in the baseline survey. On the other hand, no marked differences between the concentrations of organic substances in plasma or urine were found according to the respective workplace (plant, laboratory and administration). The results of the present survey indicate that after 6 years of regular operation, the workers at the HWI are not occupationally exposed to PCDD/Fs and other organic substances in their workplaces.  相似文献   

9.
Eight sewage sludges from rural, urban and industrial wastewater treatment plants (WWTPs) in Catalonia (Spain) were analysed for polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and biphenyls (PCBs) to determine the present levels of contamination. A method based on an automated cleanup system followed by an isotope-dilution high-resolution mass spectrometric analysis was employed. Total toxicity equivalent (WHO-TEQ) values were calculated using the toxicity equivalent factors (WHO-TEFs) proposed by WHO for dioxin-like PCBs, PCDDs and PCDFs. The WHO-TEQ(PCDD/F) values for these samples ranged from 4.9 to 20.8 pg/g dry weight (d.w.), with a mean value of 9.3 pg/g d.w., whereas WHO-TEQ(PCB) levels ranged between 1.9 and 6.6 pg/g d.w., with a mean value of 4.2 pg/g d.w. The WHO-TEQ(PCB) contribution varied from 13% to 50%, suggesting that PCB contribution on the toxicity of the samples must be taken into account. Moreover, these contemporary PCDD, PCDF and PCB concentrations were compared with previous data obtained from sewage sludge samples collected during the 80s. Our findings show that contemporary PCDD, PCDF and PCB levels have declined since the 80s.  相似文献   

10.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

11.
Congener-specific analyses of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and non-ortho (coplanar) polychlorinated biphenyls (cPCBs) were performed on 20 non-pooled breast milk samples collected in or close to an industrial area of Wallonia (Belgium). PCDD/F concentrations ranged between 16.0 and 52.1 pg TEQ/g fat, with a mean value of 29.4 pg TEQ/g fat. If coplanar PCBs (77, 126, 169) are included in TEQ calculations, levels ranged between 22.2 and 100.2 pg TEQ/g fat, with a mean value of 40.8 pg TEQ/g fat. It appears that 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF and PCB-126 account for more than 90% of the TEQ. Estimated PCDD/F dietary intake is 76 pg TEQ/kg body weight (bw)/day. This value is almost 20 times higher than the World Health Organization tolerable daily intake. A value of 103 pg TEQ/kg bw/day represents the intake of PCDDs, PCDFs and cPCBs (no mono-ortho PCBs included).  相似文献   

12.
Sin DW  Choi JY  Louie PK 《Chemosphere》2002,47(6):647-653
A total of 27 ambient air samples of were collected from six locations in Hong kong during the period of January-August, 2000 and analysed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). In all sampling locations, higher concentrations of PCDDs/PCDFs, ranging from 0.03 to 0.43 pg I-TEQ/m3 were measured in winter months (January and March) than in the summer months (July and August) of concentrations at 0.018-0.025 pg I-TEQ/m3. These concentrations are similar to annual ranges reported earlier for two Hong Kong urban sites and other urban cities in Asia. Europe, and the United States. Despite significant seasonal variations in ambient air concentrations of PCDD/Fs (expressed in I-TEQ) were observed, the congener profiles of all the samples in this study period were similar, with OCDD, 1,2,3,4,6,7,8-HpCDD, OCDF and 1,2,3,4,6,7,8-HpCDF being the predominant species. However, the homologue profiles for the samples collected at the six locations of this study were found to display significantly different spatial and seasonal trends.  相似文献   

13.
PCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.4 and 4.27 pg I-TEQ kg(-1) with a geometric mean of 0.76 pg I-TEQ kg(-1), while those in ambient air were between 23 and 563 f gm(-3), with geometric mean of 82.0 f gm(-3). Ambient air PCDD/F concentration in the city center was about 10 times higher than those in the rural area. Combustion activities present in the area were assessed to be the most significant source of the PCDD/F pollution based on the congener and homologue profiles and statistical analysis of the data. The deposition rate modeling of USEPA was applied and the deposition rates were determined in the range between 7.6 and 66.3 ng I-TEQ m(-2)year(-1) with a geometric mean of 15.9 ng I-TEQ m(-2)year(-1). The rates were higher than the recommended deposition rates in relation to the tolerable daily intake (TDI) range of PCDD/Fs for humans. The deposition velocities computed were also found to be high in both low and highly chlorinated PCDD/Fs, and this was attributed to the vapor phase deposition of volatile PCDD/Fs, and the scavenging effect of the precipitation on the particle-bound PCDD/Fs.  相似文献   

14.
This study was designed to evaluate soil and air (gas and particle) transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to vegetation in residential and industrial areas. In a first part, soil-vegetation transfer was assessed. The levels of PCDD/Fs in 120 soil and 120 herbage samples collected from 1996 to 2002 in an industrial area of Montcada (Barcelona, Spain), near a municipal solid waste incinerator (MSWI), were determined. Some additional individual samples were also evaluated. It was concluded that high soil concentrations, which are not at steady state with the air layer above it, show a tendency for PCDD/Fs to escape via volatilization. In a second part of the study, air-vegetation transfer was examined. PCDD/F concentrations from 24 herbage samples were used, while PCDD/F concentrations were also measured in seven high-volume air samples and seven passive air-vapor samples. Scavenging coefficients (m3 air "sampled"/g grass d.m.) ranged from 1.9 to 11.3 m3/g. A good trend with K(OA) was observed for PCDDs (R=0.82), while it was lower for PCDFs (R=0.55). The current results corroborate that PCDD/F concentrations in vegetation are associated with atmospheric deposition. For the highest substituted PCDD/F congeners, the air-particle uptake from plants is the principal pathway. In regions impacted by combustion emission sources, PCDD/F gas-particle partitioning is influenced by a higher concentration of particles in the air. Particles and associated particle-bound PCDD/Fs would sorb to leaf surfaces, and are subject to removal via wash off. However, in areas where emissions to air are not very notable, vapor absorption would be the principal source of vegetation pollution. The results of this investigation can have a potential interest in risk assessment studies and environmental fate models.  相似文献   

15.
Arfi C  Seta N  Fraisse D  Revel A  Escande JP  Momas I 《Chemosphere》2001,44(6):1347-1352
We evaluated individual adipose tissue (subcutaneous lipomas) dioxin contamination in non-occupationally exposed persons living in France (adult patients undergoing a surgical ablation of benign lipomas), in relation to the corresponding individually evaluated mean daily dietary dioxin intake (DDDI). The diet survey (questionnaire) included information on consumption of meat, fish, milk and dairy products, from which the individual DDDI was calculated. Sixteen subjects participated in this study. DDDI ranged between 1.06 and 3.31 pg I-TEQ/kg body weight, bw (mean value: 2.05+/-0.72). Adipose tissue polychlorinated dibenzo-p-dioxins (PCDD)/polychlorinated dibenzofurans (PCDF) levels ranged between 18.5 and 76.9 pg I-TEQ/g lipids (mean value: 35.6+/-14.8). No relation was found between the DDDI and adipose tissue PCDD/PCDF concentrations. The mean DDDI in France does not fundamentally differ from those found in other industrialised countries, is within the range of 1-4 pg I-TEQ/kg/day recently suggested by WHO-ECEH/ICPS for the tolerable daily intake of dioxins. Adipose tissue PCDD/PCDFs levels are similar to levels in other European countries and USA without relation to sex or age, and can be considered representative European background concentrations. Globalisation of alimentary production leads to a similar food exposure in Western European countries, in spite of dioxins accidental selective contaminations that are epiphenomenon and thus do not have any impact in human dioxin background levels.  相似文献   

16.
There is no previous report from Turkey on chemically determined polychlorinated dibenzo-para-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (PCBs) in human tissues expressed as World Health Organization (WHO) toxic equivalents (TEQs). The objective of this study was to determine the occurrence of PCDDs/Fs, and dioxin-like PCBs in the general adult Turkish population. For this reason we measured adipose tissue concentrations of PCDDs/Fs and dioxin-like PCBs in 23 Turkish men living in Ankara,Turkey in 2004. PCDD/F concentrations ranged between 3.2 and 19.7 pg WHO-TEQ/g fat (5.34 and 42.7 WHO-TEQ/g fat, respectively, including dioxin-like PCBs). The mean concentrations of WHO(PCDD/F)-TEQ and WHO(PCB)-TEQ were 9.2 and 6.67 pg/g on a lipid basis , respectively. Samples were analyzed for PCDD/F and twelve dioxin-like PCB congeners using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). This study is very important since it is the first report on PCDDs/Fs and dioxin-like PCB contamination in human adipose tissue from Turkey.  相似文献   

17.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were measured in bulk deposition at three Danish rural forest sites with a mutual maximum distance of 450 km. At one of the forest sites concentrations in the ambient atmosphere were sampled from a 12 m high tower. Sampling was carried out within a period of 3 years with sampling intervals of 1–2 months. Mean bulk deposition fluxes were 1 ng m−2 yr−1 I-TEQ and deviated less than 30% between the sites. Yearly average PCDD/F concentrations in the atmosphere were 24 fg m−3 I-TEQ with maximum values in the winter period. During winter months atmospheric concentrations of PCDD/F and oxidized sulphur compounds showed a positive correlation, furthermore seasonal bulk deposition showed correlation between PCDD/F and sulphate.  相似文献   

18.
Ten years measuring PCDDs/PCDFs in ambient air in Catalonia (Spain)   总被引:2,自引:0,他引:2  
This work summarizes the results of a ten year surveillance programme on PCDD/F in ambient air carried out in Catalonia (Spain). The study has been conducted by the Dioxin Laboratory of Spanish Council for Scientific Research (CSIC) in collaboration with the Environment Department of the Catalonian Government. 175 samples have been collected throughout Catalonia from 1994 to 2004. Different sampling locations classified as industrial, traffic, urban, suburban and rural sites have been monitored in order to find the most contaminated zones as well as the ones with expected background concentrations. The highest concentrations found in this study were determined at the industrial locations. Concentrations ranging from 5 to 1196 fg I-TEQ/m3, with a mean value of 140 fg I-TEQ/m3 and from 10 to 357 fg I-TEQ/m3, with a mean value of 72 fg I-TEQ/m3 were determined in industrial and traffic sampling points, respectively. In contrast, the lowest concentrations were found in rural stations, ranging from 5 to 45 fg I-TEQ/m3, with a mean value of 28 fg I-TEQ/m3. The PCDD/F concentration trend in Catalonian ambient air shown a clear drop of the median values occurred during the study sampling period. A decline of about 70% was observed from 1997-1998 to 2003-2004.  相似文献   

19.
Estonia still has no waste incineration facilities, which would act as substantial sources of dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) pollution. As landfill fires may serve as sources of dioxins, we focused on the concentrations of PCDD and PCDF in soil samples taken in the vicinity of the landfill located at south-east Estonia in the course of our inventory. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were studied in five soil samples taken in the vicinity of the Laguja landfill in south-east Estonia. The four soil samples were taken in southern, eastern, western and northern parts not further than 300 m from the landfill, and one sample was taken at the distance of 3 km from the landfill. The PCDD/F concentrations in all soil samples were at background level (0.64-2.33 pg I-TEQ WHO/g dry weight). To maintain this situation, the administrator of the landfill must avoid landfill fires, which are one of the reasons for the generation of dioxins and furans.  相似文献   

20.
To assess the influence of a new hazardous waste incinerator (HWI) on public health, a preoperational monitoring program was established during the period of construction. In this study, the levels of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) accumulated in adipose tissue of 15 autopsied subjects living in the area under potential impact of the HWI were determined after approximately 3 years of regular operations in the facility. The non-ortho PCBs 77, 126 and 169 were also determined. PCDD/F concentrations ranged between 1.5 and 41 pg WHO-TEQ/g fat (2.4 and 72 WHO-TEQ/g fat, respectively, including PCBs), with a mean value of 11 pg WHO-TEQ/g fat and a median value of 7.4 pg WHO-TEQ/g fat (22 and 13 WHO-TEQ/g fat, respectively, including PCBs). In the baseline study, the mean level of PCDD/Fs was 36 pg WHO-TEQ/g fat (61 pg WHO-TEQ/g fat, including non-ortho PCBs 77, 126 and 169), which means a reduction of 70% (64% including PCBs). This notable reduction is in accordance with the important decrease observed in recent years in PCDD/F intake through the diet. The current concentrations of PCDD/Fs in human adipose tissue, as well as recent data on PCDD/F levels in plasma and breast milk of subjects living in the vicinity of the same HWI, indicate that there is not any additional significant exposure to PCDD/Fs for this population.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号