1.
The microbiological quality in dental unit waterlines (DUWLs) is considered to be important because patients and dental staff with suppressed immune systems are regularly exposed to water and aerosols generated from dental units (DUs). Opportunistic pathogens like Pseudomonas, Legionella, Candida, and Aspergillus can be present in DUWLs, while during consultations, bioaerosols can be dispersed in the air, thus resulting in effects on microbiological quality of indoor air. This present study represents microbiological air and water quality in dental offices (DOs) and also concerns the relationship between the quality of DO air and dental unit water. This study aimed to assess both the microbial quality of dental unit water and the indoor air in 20 DOs and to survey the effect on the quality of the indoor air with the existing microorganisms in dental unit water. Fourteen out of 20 (70 %) DUWLs were found to be contaminated with a high number of aerobic mesophilic heterotrophic bacteria. In terms of bacterial air contamination levels, in 90 % of DOs, a medium level (<500 colony-forming units (CFU)/m3) of contamination was determined, while in terms of microfungal air contamination, in all DOs, a low level (<100 CFU/m3) of contamination was determined. Potential infection or allergen agents, such as Pseudomonas, Micrococcus, Staphylococcus, Alternaria, Cladosporium, Penicillium, Aspergillus, and Paecilomyces were isolated from water and air samples. This study’s determination of contamination sources and evaluation of microbial load in DOs could contribute to the development of quality control methods in the future.  相似文献   

2.
The water used in dental unit waterlines (DUWLs) acts as a coolant for the high-speed equipment and as an irrigant during dental treatments. There are kind of water tanks. DUWLs provide a favorable environment for microbial biofilm and multiplation primarily due to the high surface in the tubing and the character of fluid dynamics in narrow, smooth-walled waterlines. Biofilms can harbour opportunist pathogens such as Legionella sp., Pseudomonas sp. Several studies have shown that DUWLs have high levels of microbial contamination. Presence of high level of microbial contamination is an important problem for dentists and dental patients who are immunocompromised. We collected water samples from DUWLs of 20 private dental offices. We have determined that only 2 (3.4%) out of 59 dental unit water samples were found to meet the standard (<200 CFU.ml(-1)) for DUWLs water quality by American Dental Association (ADA). Of the 59 water samples examined, 14 (24%) were positive for Pseudomonas sp. and 18 (30.5%) were positive for fungi. The most common 14 bacterial strains and seven fungi were isolated. Of bacterial strains, 57.1% were identified: Majority of the bacterial species isolated from our samples was identified as Pseudomonas fluorescens, Pasteurella haemolytica, Photobacterium damsela, Ochrobacter anthropi, Moraxella sp., Aspergillus flavus, Penicillium expansum. Legionella sp. were not detected in all water samples.  相似文献   

3.
Although bacterial contamination is widely researched in dental unit water systems, we have been unable to find any published reports to date about the presence and distribution of sulphate-reducing bacteria (SRB) in dental unit waterlines (DUWLs). The aim of this study was to evaluate microbial contamination and to determine the presence and distribution of SRB in DUWLs. One hundred twenty-three water samples were collected from the air–water syringes, high-speed drills and water sources from 41 dental units in Istanbul, Turkey. The counts of aerobic heterotrophic bacteria and SRB were investigated in the water samples. In addition, the presence of free-living amoebae (FLA) was examined. In this work, we evaluated microbial contamination and reported for the first time the distribution of SRB in DUWLs. We determined that only ten out of 123 water samples were able to meet the American Dental Association’s limit (≤200 CFU ml − 1). SRB were observed in 102 out of 123 samples (82.9%). In addition, SRB were detected in all of the air–water syringes and high-speed drills. FLA were established in 103 out of 123 samples (83.7%).  相似文献   

4.
Safety of patients and dental personnel requires the appropriate microbiological water quality in dental units. During treatment, patients and dental workers are exposed both to direct contact with bacteria-contaminated water in the form of splatter and with contaminated water aerosol emitted during work by unit handpieces, including rotating and ultrasonic instruments. The aim of the study was to determine the qualitative and quantitative contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria. The study material included water sampled from 107 dental unit reservoirs located in dental surgeries of public health centres. Conventional microbiological methods were used to identify microorganisms. The study shows that the contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria is commonplace. The mean concentration of mesophile bacteria in dental unit reservoir water exceeded 1.1?×?105 cfu/ml. The prevailing species were Gram-negative bacteria of the families Burkholderiaceae, Pseudomonadaceae, Ralstoniaceae and Sphingomonadaceae. The most numerous bacteria were Ralstonia pickettii, constituting 49.33 % of all the identified aerobic and facultative anaerobic bacteria. Among Gram-positive rods, the most numerous were bacteria of the genus Brevibacterium (5.83 %), while the highest percentage shares (13.25 %) of all Gram-positive microorganisms were found for Actinomyces spp. The study confirms the necessity of regular monitoring of microbial contamination of dental unit waterlines (DUWL) and use of various water treatment procedures available to disinfect DWUL.  相似文献   

5.
This study was conducted to assess potential human health risks presented by pathogenic bacteria in a protected multi-use lake-reservoir (Lake Ma Vallée) located in west of Kinshasa, Democratic Republic of Congo (DRC). Water and surface sediments from several points of the Lake were collected during summer. Microbial analysis was performed for Escherichia coli, Enterococcus (ENT), Pseudomonas species and heterotrophic plate counts. PCR amplification was performed for the confirmation of E. coli, ENT, Pseudomonas spp. and Pseudomonas aeruginosa isolated from samples. The results reveal low concentration of bacteria in water column of the lake, the bacterial quantification results observed in this study for the water column were below the recommended limits, according to WHO and the European Directive 2006/7/CE, for bathing water. However, high concentration of bacteria was observed in the sediment samples; the values of 2.65?×?103, 6.35?×?103, 3.27?×?103 and 3.60?×?108 CFU g?1 of dry sediment for E. coli, ENT, Pseudomonas spp. and heterotrophic plate counts, respectively. The results of this study indicate that sediments of the Lake Ma Vallée can constitute a reservoir of pathogenic microorganisms which can persist in the lake. Possible resuspension of faecal indicator bacteria and pathogens would affect water quality and may increase health risks to the population during recreational activities. Our results indicate that the microbial sediment analysis provides complementary and important information for assessing sanitary quality of surface water under tropical conditions.  相似文献   

6.
The aims of the present study were to determine the levels of bioaerosols including airborne culturable bacteria (total suspended bacteria, Gram-positive bacteria, Staphylococcus, Staphylococcus aureus, methicillin-resistant S. aureus (MRSA), and Gram-negative bacteria), fungi, endotoxin, and viruses (influenza A, influenza B, respiratory syncytial virus types A/B, parainfluenza virus types 1/2/3, metapnemovirus, and adenovirus) and their seasonal variations in indoor air of residential apartments. Of the total suspended bacteria cultured in an indoor environment, Staphylococcus was dominant and occupied 49.0 to 61.3 % of indoor air. Among Staphylococcus, S. aureus were detected in 100 % of households' indoor air ranging from 4 to 140 CFU/m3, and 66 % of households were positive for MRSA ranging from 2 to 80 CFU/m3. Staphylococcus and S. aureus concentrations correlated with indoor temperature (adjusted β: 0.4440 and 0.403, p?<?0.0001). Among respiratory viruses, adenovirus was detected in 14 (14 %) samples and influenza A virus was detected in 3 (3 %) samples regarding the indoor air of apartments. Adenovirus concentrations were generally higher in winter (mean concentration was 2,106 copies/m3) than in spring (mean concentration was 173 copies/m3), with concentrations ranging between 12 and 560 copies/m3. Also, a strong negative correlation between adenovirus concentrations and relative humidity in indoor air was observed (r?=??0.808, p?<?0.01). Furthermore, temperature also negatively correlated with adenovirus concentrations (r?=??0.559, p?<?0.05).  相似文献   

7.
The present work aims at identification of multiple drug-resistant pathogenic bacteria in a selected stretch, namely, Puri on the Bay of Bengal, India. Six stations at the coast of Puri were selected and samples of water and sediment were collected during the winter of 2008 and 2009 for this study. Thirty-eight pathogenic bacteria were isolated and identified from both the water and the sediment of 6 fixed stations (PU-1a, PU-1b, PU-2, PU-3, PU-4, and PU-5). The identified pathogens were Escherichia coli, Vibrio cholerae, Vibrio parahaemolyticus, Klebsiella pneumoniae, Staphylococcus aureus, Enterococcus faecalis, Pseudomonas aeruginosa, and Proteus mirabilis. Antibiotic sensitivity of the isolated bacteria was studied by using 12 selected antibiotics, commonly used for the medication of human beings and animals. The isolated pathogens from both the water and the sediment samples showed lowest resistance to chloramphenicol (C-30 μg) where as the pathogens showed highest level of resistance to ampicillin (10-μg) among the antibiotics used for the study. Among the isolated pathogens E. faecalis (PU-1a), P. aeruginosa (PU-2 and PU-3), E. coli (PU-3 and PU-4), and K. pneumonia (PU-4) showed resistance to more than four antibiotics. Out of the isolated species, 57.8% pathogens were multi-drug resistant. Antibiotic resistance indexes of all the stations were calculated and found to be in the range of 0.066 to 0.083.  相似文献   

8.
In this study, we investigated the distribution of Legionella in sources of spring water and wastewater throughout Taiwan. Legionella were detected with culture method and PCR method from water samples, combined with molecular methods that allow the taxonomic identification of Legionella species. Factors associated with the distribution of Legionella including the physical?Cchemical and microbiological water quality characteristics were also measured. Legionella were detected in 18 of the 68 samples. Additionally, 16 of the 68 samples analyzed by polymerase chain reaction (PCR) and eight of the 68 samples evaluated using the culture method were found to be positive for Legionella. The Legionella species identified included Legionella pneumophila, unnamed Legionella genotypes, uncultured Legionella spp., and Legionella lytica. Legionella species were found in water with temperatures ranging from 10.0 to 50.6??C and with pH values ranging from 5.59 to 9.32. Significant differences (Mann?CWhitney U test, P?<?0.05) were observed in the presence/absence of Legionella in samples with different pH values when Legionella were detected by the culture method. The results of this survey confirmed that Legionella is ubiquitous in the water of spring recreational areas in Taiwan. Long-term investigations of the occurrence of Legionella in hot spring recreational areas throughout Taiwan are needed.  相似文献   

9.
This is a cross-sectional study of the incoming and distal outlet water quality from 41 dental units in Istanbul, carried out to compare the total microbial loads using traditional culture method versus epifluorescence microscopy. The possible presence of Legionella pneumophila using traditional culture method was also analyzed. One hundred and twenty three samples were taken from the high-speed handpiece lines, air-water syringe lines and source (incoming) water supplies from 41 dental units. The samples were assayed for live/dead bacteria, heterotrophic bacterial counts and presence of L. pneumophila bacteria. Thirty nine out of 41 dental units (91%) were not able to meet the standard limit of 200 CFU/ml in dental unit waters. The live bacterial counts were 1-1.5 orders of magnitude higher than aerobic mesophilic heterotrophic bacteria. L. pneumophila (serogroup 2-14) was isolated from five out of 41 units. Some dental units were using commercially bottled (19 l) drinking water as a source. The source water of eight dental unit was heavily contaminated which were fed up by commercially bottled drinking water.  相似文献   

10.
Samples of soil, water, and sediments from industrial estates in Lagos were collected and analyzed for heavy metals and physicochemical composition. Bacteria that are resistant to elevated concentrations of metals (Cd2?+?, Co2?+?, Ni2?+?, Cr6?+?, and Hg2?+?) were isolated from the samples, and they were further screened for antibiotic sensitivity. The minimum tolerance concentrations (MTCs) of the isolates with dual resistance to the metals were determined. The physicochemistry of all the samples indicated were heavily polluted. Twenty-two of the 270 bacterial strains isolated showed dual resistances to antibiotics and heavy metals. The MTCs of isolates to the metals were 14 mM for Cd2?+?, 15 mM for Co2?+? and Ni2?+?, 17 mM for Cr6?+?, and 10 mM for Hg2?+?. Five strains (Pseudomonas aeruginosa, Actinomyces turicensis, Acinetobacter junni, Nocardia sp., and Micrococcus sp.) resisted all the 18 antibiotics tested. Whereas Rhodococcus sp. and Micrococcus sp. resisted 15 mM Ni2?+?, P. aeruginosa resisted 10 mM Co2?+?. To our knowledge, there has not been any report of bacterial strains resisting such high doses of metals coupled with wide range of antibiotics. Therefore, dual expressions of antibiotics and heavy-metal resistance make the isolates, potential seeds for decommissioning of sites polluted with industrial effluents rich in heavy metals, since the bacteria will be able to withstand in situ antibiosis that may prevail in such ecosystems.  相似文献   

11.
We evaluated the in vitro activity of antimicrobial agents against Legionella obtained from hotel and hospital water systems in three different regions of Turkey. Sixty-five Legionella strains (Legionella pneumophila serogroup 6 [n?=?32], L. pneumophila serogroup 1 [n?=?27], L. pneumophila serogroup 3 [n?=?2], and Legionella spp. [n?=?4]) were tested against levofloxacin, ciprofloxacin, clarithromycin, azithromycin, and rifampicin. The minimum inhibitory concentration (MIC) values of each antimicrobial agent for these strains was determined by the microdilution method using buffered yeast extract medium supplemented with 0.1% ketoglutarate broth. L. pneumophila ATCC 33152, Staphylococcus aureus ATCC 29213, and Escherichia coli ATCC 25922 were used as controls. Minimum inhibitory concentration values were in the following ranges: clarithromycin 0.001–0.5 mg/L, azithromycin 0.001–0.5 mg/L, levofloxacin 0.001–0.5 mg/L, ciprofloxacin 0.001–0.125 mg/L, and rifampicin 0.001– 0.5 mg/L. The MIC90 for rifampicin, levofloxacin, ciprofloxacin, azithromycin, and clarithromycin were 0.015, 0.125, 0.06, 0.125, and 0.06 mg/L, respectively. To the best of our knowledge, this is the first study to determine in vitro activities of antimicrobial agents against Legionella species in Turkey. Rifampicin had the lowest MIC90 value. It would seem that azithromycin and clarithromycin exhibit good activity as well as levofloxacin and ciprofloxacin against Legionella isolated from environmental water systems in Turkey.  相似文献   

12.
The aim of the present study was to determine the level of antibiotic resistance patterns and distribution of heavy metal resistance of bacterial isolates from aquatic animals (Lissotriton vulgaris, Pelophylax ridibundus, Emys orbicularis, Mauremys rivulata, and Natrix natrix) in Turkey (Kavak Delta). A total of 153 bacteria have been successfully isolated from cloaca and oral samples of the aquatic amphibians and reptilians which were found, namely, Aeromonas sp. (n?=?29), Plesiomonas sp. (n?=?7), Vibrio sp. (n?=?12), Citrobacter sp. (n?=?12), Enterobacter sp. (n?=?11), Escherichia sp. (n?=?22), Klebsiella sp. (n?=?22), Edwardsiella sp. (n?=?6), Hafnia sp. (n?=?1), Proteus sp. (n?=?19), Providencia sp. (n?=?8), and Pseudomonas sp. (n?=?4). In terms of antibiotic and heavy metal susceptibility testing, each isolate was tested against 12 antibiotics and 4 metals. There was a high incidence of resistance to cefoxitin (46.40 %), ampicillin (44.44 %), erythromycin (35.29 %), and a low incidence of resistance to gentamicin (6.53 %), kanamycin (8.49 %), chloramphenicol (9.15 %), and cefotaxime (10.45 %). The multiple antibiotic resistance index of each bacterial species indicated that bacteria from raised amphibians and reptiles have been exposed to tested antibiotics, with results ranging from 0 to 0.58. Most isolates showed tolerance to different concentrations of heavy metals, and minimal inhibition concentrations ranged from100 to >3,200 μg/mL. According to these results, a significant occurrence of bacteria in the internal organs of reptiles and amphibians, with a high incidence of resistance against antibiotics and heavy metals, may risk aquatic animals and the public health. These data appoint the importance of epidemiological surveillance and microbiological monitoring and reinforce the need to implement environment protection programs for amphibian and reptile species.  相似文献   

13.
This paper presents information about airborne mesophilic bacteria in the indoor and outdoor air of child day-care centers (CDCCs) in the city of Edirne, Turkey. Air samples were collected using the Petri plate gravitational settling method from the indoor and outdoor air of CDCCs. Counts of airborne bacteria were measured as colony forming units (CFU) collected by gravity onto Brain Heart Infusion Agar plates (with 5% sheep blood). Samples were taken monthly over a period of 12 months between January and December 2004. A total of 3,120 bacteria colonies were counted on 192 Petri plates. Four groups of culturable bacteria were identified: Gram-positive cocci, Gram-positive bacilli, endospore-forming Gram-positive bacilli, and Gram-negative bacteria. Airborne Gram-positive bacteria were the most abundant at more than 95% of the measured population. While Gram-positive cocci were more common in indoor environments, Gram-positive bacilli were more dominant in outdoor air. Bacteria commonly isolated from CDCCs were identified at a genus level. Staphylococcus (39.16%), Bacillus (18.46%), Corynebacterium (16.25%), and Micrococcus (7.21%) were dominant among the genera identified in the present study. The dominant genera identified in the day-care centers were Staphylococcus, Micrococcus, and Corynebacterium for indoor air and Bacillus, Corynebacterium, and Staphylococcus for outdoor air. Staphylococcus, Streptococcus, Bacillus, and Corynebacterium genera were found in samples from every month. Bacterial colony counts were compared by sampling location (indoors and outdoors), seasons, and meteorological factors. We found negative correlations between the monthly total outdoor bacterial counts and the sampling day’s average relative humidity and average rainfall, and the monthly average rainfall. Fluctuations in bacterial counts in different seasons were observed.  相似文献   

14.
Microbiological quality of crude oil storage tanks was determined. The samples were taken from crude oil storage tanks in three stations, at Ughelli, Escravos and Forcados tank farms in the Delta State of Nigeria. Two tanks were sampled at each station with samples collected from three levels of the tank, namely the oil layer, oil water interface, and effluent layer. Samples from the inner walls and bottom sediment of the only empty tank in Ughelli during the study were also taken. The total heterotrophic count of bacteria and total fungal count were obtained by plating samples on nutrient agar and sabouraud's glucose agar respectively and incubated for 14 days at 28 °C±2 °C. Oilutilizing bacteria and fungi were isolated on oil agar using fungizone and antibiotics to inhibit fungal and bacterial growth respectively. Pure cultures of bacteria and fungi were prepared on nutrient agar and sabouraud's glucose agar respectively at 28 °C±2 °C for 4 days. Isolates were identified using approved standard methods. Three bacterial genera, Pseudomonas, Proteus and Bacillus, and one actinomycete, Actinomyces and two fungal genera, Penicillium and Cunninghamella, were isolated. Pseudomonas was dominant among the bacteria (41.62%) and Penicillium dominant among the fungi (94%). It was also found that the total microbial load of the effluent layer was higher than that of the oil layer.  相似文献   

15.
We studied the susceptibility patterns to 15 different antibiotics and six heavy metals in Aeromonas spp. and Pseudomonas spp. isolated from Iskenderun Bay, Turkey (northeast Mediterranean Sea). A high percentage of Aeromonas isolates showed resistance to cefazolin (66.6%) and trimethoprim–sulphamethoxazole (66.6%). Amongst the Pseudomonas isolates, there was a high incidence of resistance to nitrofurantoin (86.2%), cefazolin (84.8%) and cefuroxime (71.7%). Most isolates showed tolerance to different concentrations of heavy metals, and minimal inhibition concentrations ranged from 25 to >3,200 μg/ml. The Aeromonas spp. and Pseudomonas spp. showed high resistance to copper of 98.3% and 75.4%, respectively, and low resistance to lead of 1.7% and 7.2%, respectively. Our results show that antibiotic and heavy metal resistant Aeromonas spp. and Pseudomonas spp. were widespread in Iskenderun Bay in 2007 and 2008. The increasing presence of antibiotic and heavy metal resistant Aeromonas spp. and Pseudomonas spp. may become a potential human health hazard.  相似文献   

16.
Water quality monitoring is essential for the provision of safe drinking water. In this study, we compared a selection of fecal indicators with universal Bacteroidales genetic marker to identify fecal pollution of a variety of drinking water sources. A total of 60 samples were collected from water sources. The microbiological parameters included total coliforms, fecal coliforms, Escherichia coli and fecal streptococci as the fecal indicator bacteria (FIB), Clostridium perfringens and H2S bacteria as alternative indicators, universal Bacteroidales genetic marker as a promising alternative fecal indicator, and Salmonella spp., Shigella spp., and E. coli O157 as pathogenic bacteria. From 60 samples analyzed, Bacteroidales was the most frequently detected indicator followed by total coliforms. However, the Bacteroidales assay failed to detect the marker in nine samples positive for FIB and other alternative indicators. The results of our study showed that the absence of Bacteroidales is not necessarily an evidence of fecal and pathogenic bacteria absence and may be unable to ensure the safety of the water. Further research, however, is required for a better understanding of the use of a Bacteroidales genetic marker as an indicator in water quality monitoring programs.  相似文献   

17.
The resistance pattern and mechanisms of bacterial isolates obtained from clinical origin, soil, industrial effluent, orange juice products and drinking water were studied using commonly used antibiotics. The microbial load of the water samples, industrial effluent and orange juice products were 1.0 × 101–2.25 × 106, 2.15 × 105, and 3.5 × 104–2.15 × 105 cfu mL–1, respectively. The faecal coliform test revealed that only two out of twenty orange juice products had MPN of 2 and 20, the MPN of water ranged from 1–1800, while the effluent had MPN of 1800. The bacterial isolates that were isolated include E. coli, S. aureus, P. vulgaris, S. marcescens, S. pyogenes, B. cereus, B. subtilis, Micrococcus sp., Klebsiella sp., P. aeruginosa, and Enterobacter sp. Also, clinical and soil isolates of P. aeruginosa were used in the study. Among the eight antibiotics tested for resistance on five strains of each bacterium, seven different resistance patterns were observed among the bacterial isolates obtained from water, effluent and orange juice products. Among the clinical and soil isolates of P. aeruginosa, four multiple-drug resistance patterns were obtained. Thirty strains of E. coli and S. aureus were tested for -lactamase production and fourteen strains, seven each of E. coli and S. aureus that had high Minimum Inhibitory Concentration values (MIC) for both Amoxycillin and Cloxacillin were positive.  相似文献   

18.
Urbanization and industrialization has increased the strength and qualities of municipal sewage in Bangalore, India. The disposal of sewage into natural water bodies became a serious issue. Byramangala reservoir is one such habitat enormously polluted in South India. The water samples were collected from four hotspots of Byramangala tank in 3 months. The biochemical oxygen demand (BOD) and bacterial counts were determined. The fecal coliforms were identified by morphological, physiological, and biochemical studies. The antibiotics sensitivity profiling of isolated bacteria were further carried out. We have noticed that a high content of BOD in the tank in all the 3 months. The total and fecal counts were found to be varied from 1.6?×?106 to 8.2?×?106?colony forming unit/ml and >5,500/100 ml, respectively. The variations in BOD and total count were found to be statistically significant at p?>?0.05. Many pathogenic bacteria were characterized and most of them were found to be multidrug resistant. Salmonella showed resistance to cefoperazone, cefotaxime, cefixime, moxifloxacin, piperacillin/tazobactam, co-trimoxazole, levofloxacin, trimethoprim, and ceftazidime. Escherichia coli showed resistance to chloramphenicol, trimethoprim, co-trimoxazole, rifampicin, and nitrofurantoin while Enterobacter showed resistant to ampicillin, cefepime, ceftazidime, cefoperazone, and cefotaxime. Klebsiella and Shigella exhibited multiple drug resistance to conventional antibiotics. Staphylococcus showed resistance to vancomycin, methicillin, oxacillin, and tetracycline. Furthermore, Salmonella and Klebsiella are on the verge of acquiring resistance to even the strongest carbapenems-imipenem and entrapenem. Present study revealed that Byramanagala tank has become a cesspool of multidrug-resistant “superbugs” and will be major health concern in South Bangalore, India.  相似文献   

19.
A total of 144 isolates of Pseudomonas spp. (48 each from the Yamuna River water, wastewater irrigated soil and groundwater irrigated soil) were tested for their resistance against certain heavy metals and antibiotics. Minimum inhibitory concentrations (MICs) of Hg2?+?, Cd2?+?, Cu2?+?, Zn2?+?, Ni2?+?, Pb2?+?, Cr3?+? and Cr6?+? for each isolate were also determined. A maximum MIC of 200 ??g/ml for mercury and 3,200 ??g/ml for other metals were observed. The incidences of metal resistance and MICs of metals for Pseudomonas isolates from the Yamuna water and wastewater irrigated soil were significantly different to those of groundwater irrigated soil. A high level of resistance against tetracycline and polymyxin B (81.2%) was observed in river water isolates. However, 87.5% of Pseudomonas isolates from soil irrigated with wastewater showed resistance to sulphadiazine, whereas 79.1% were resistant to both ampicillin and erythromycin. Isolates from soil irrigated with groundwater exhibited less resistance towards heavy metals and antibiotics as compared to those of river water and wastewater irrigated soil. Majority of the Pseudomonas isolates from water and soil exhibited resistance to multiple metals and antibiotics. Resistance was transferable to recipient Escherichia coli AB2200 strains by conjugation. Plasmids were cured with the curing agent ethidium bromide and acridine orange at sub-MIC concentration.  相似文献   

20.
Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the β-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the β-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.  相似文献   