首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

2.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

3.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

4.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

5.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

6.
The aim of this work is to give representative data on polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyl (PCBs) from stack gas emissions of an urban solid waste management plant which has to comply with the limit of 0.1 ng I-TEQ/Nm3. In particular, the study is focused on 29 target compounds, the seventeen 2,3,7,8-PCDDs/Fs, four non-ortho PCBs and eight mono-ortho PCBs which configure so-called 'dioxin-like' PCBs (DL-PCBs). To this end, emission measurements were performed during one year over the three operating combustion lines in a selected waste management plant. In general, accurate methodology allowed characterizing all target compounds in almost all the samples analyzed. In addition, a typical pattern for DL-PCBs is reported. The pattern presented PCB #118 to be the highest, nevertheless the figures demonstrated DL-PCBs contribution to the total TEQ around 3% being PCB #126 the most important congener due to its TEF of 0.1. Finally, remarkable differences were achieved in comparison with both environmental and biological samples such as soils, sediments, human milk or fish since these matrices may present DL-PCB contribution to the total TEQ up to 77%.  相似文献   

7.
Blood serum specimens from 81 non-occupationally exposed adults residing in four areas close to municipal and waste incinerators as well as metallurgical industry plant and 44 adult subjects coming from control area of Slovakia were analysed for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and polybrominated diphenylethers (PBDEs). The concentration of total WHO(98)TEQ PCDD/F/dl-PCBs in whole group of donors from areas where known sources causing dioxin contamination are present was significantly higher than in control group of donors (p<0.001). Correlation between the age of donors and PCDD/F and dl-PCB levels was confirmed (Spearman's r(PCDD/Fs)=0.543, r(dl-PCBs)=0.521, p<0.001). Furthermore, this study presents first results concerning the PBDE congeners in human serum of Slovak general population. The total concentration (congeners 28, 47, 99, 100, 153, 154, 183) in control group was approximately 1.5-times higher in comparison to that of residents coming from areas with supposed environmental pollution. The most abundant congeners in all samples were BDE-47 and BDE-153 with median values of 0.24 ng g(-1) lipid and 0.23ngg(-1) lipid, respectively. The positive association between PBDE values and age of donors was not found.  相似文献   

8.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

9.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

10.
Abstract

This study investigates the characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the ambient air of two municipal solid waste incinerators (MSWIs: GS and RW) and a coal-fired power plant (PW) in the Kaohsiung County (KC) area in Taiwan. The results show that the toxic equivalency (TEQ) concentration in the flue gas of GS and RW averaged 0.090 and 0.044 ng international toxic equivalents (I-TEQ)/N·m3, respectively. The TEQ concentration in the flue gas of PW averaged 0.050 ng I-TEQ/N·m3. All PCDD/Fs concentrations from the stack flue gas are lower than the Taiwan Environmental Protection Administration emission standard. Furthermore, the mean I-TEQ concentration in the ambient atmosphere ranged from approximately 0.019 to 0.165 pg I-TEQ/N·m3, much lower than the environmental quality standards for dioxins in Japan (0.6 pg TEQ/N·m3). This work classified all sampling sites into three clusters according to k-means cluster analysis. The result shows a probable direct correlation between the GS incinerator and site C. Although the concentration from the PW plant did not exceed the emission standard, it was much higher than that in Fernández-Martínez’s study. For proper environmental management of dioxins, establishing a complete emission inventory of PCDD/Fs is necessary. The government of Taiwan should particularly pay more attention to power plants to address the information shortage.  相似文献   

11.
Abad E  Caixach J  Rivera J 《Chemosphere》2003,50(9):1175-1182
This study presents the results of a dioxin abatement programme undertaken in the municipal waste incineration plant of Montcada i Reixac (Barcelona, Spain) after the replacement of an obsolete air cleaning device by a new flue gas treatment system. A number of sampling campaigns were conducted with the aim of characterising stack gas emission levels of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and to evaluate initial specifications of dioxin stack gas emission values below 0.1 ng I-TEQ/Nm(3). Preliminary results revealed levels between 44 and 111 ng I-TEQ/Nm(3) when the gas-cleaning system consisted only of an old electrostatic precipitator (ESP). Decreased levels around 15 ng I-TEQ/Nm(3) were observed when the semi-dry scrubber began to operate and the ESP was switched off. Again, remarkable dioxin removal was observed after the installation of the fabric filter and levels around 0.3-0.4 ng I-TEQ/Nm(3) were soon achieved. Nevertheless, the limit of 0.1 ng I-TEQ/Nm(3) was reached by additional injection of activated carbon which helped to lower PCDD/PCDF levels to around 0.036 ng I-TEQ/Nm(3). The results also demonstrated a significant change in the dioxin distribution present in combustion-derived materials (stack gas emission, bottom ash and solid waste from gas treatment). The major dioxin fraction was found in gaseous matrices before the flue gas control system was upgraded. After this step, the major dioxin fraction content was observed in solid waste from gas treatment.  相似文献   

12.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):701-707
This study was carried out to examine the formation and the emission status of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in the flue gases of commercial-scale municipal solid waste (MSW) incinerators, and thus to provide the engineering data for the reduction of PCDDs/PCDFs emitted from MSW incinerators. The formation concentrations of the PCDDs/PCDFs generated at the outlet of waste heat boilers (WHB) were in the range of 1.18-29.61 ng-TEQ/N m3 (average 5.75 ng-TEQ/N m3), while the emission concentrations at the stacks were in the range of 0.026-4.548 ng-TEQ/N m3 (average 0.924 ng-TEQ/N m3). Two major 2,3,7,8-substituted congeners were 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF, and their concentrations were up to 50% and 64% of total TEQ values at the outlet of WHB and the stack, respectively. From the results of multi-regression analysis, the formation concentration of PCDDs/PCDFs could be predicted as follows with the correlation factor of r2 = 0.962: PCDDs/PCDFs (ng-TEQ/N m3) = 3.036 (Cl) + 0.094 (T1) - 0.472 (Combustibles) + 0.059 (CO) - 0.039 (THC) - 3.366 (H) + 22.157, where T1 (degrees C) is the temperature at the outlet of the WHB. Cl, Combustibles and H are given as percentages and the others are in parts per million.  相似文献   

13.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

14.
The stack flue gases and the ashes in different units of two municipal solid waste incinerators (MSWIs) are sampled to investigate the characteristics of polybrominated diphenyl ethers (PBDEs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs), and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Bottom ashes (BA) exhibited much higher PBDD/F (8.11-52.2 pg TEQ/g) and PBDE contents (20.4-186 ng/g) than those of fly ashes (0.0932-2.02 pg TEQ/g and 0.332-25.5 ng/g), revealing that the PBDD/Fs and PBDEs in the feeding waste may not be completely destroyed. The PBDE concentrations/contents in the stack flue gases (26.1-109 ng/Nm3) and in the BA (20.4-186 ng/g) of the MSWIs could reach three orders higher than those in the atmosphere and reference soils. PBDE contributions to the environment from the stack flue gases or the reutilization of BA of MSWIs should not be ignored from the developing PBDE inventory.  相似文献   

15.
Ni Y  Zhang Z  Zhang Q  Chen J  Wu Y  Liang X 《Chemosphere》2005,60(6):779-784
The purpose of this research was to determine polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) in five chlorinated chemicals (phthalocyanine copper, phthalocyanine green, chloranil-1 and 2, and triclosan), and to compare their 2,3,7,8-tetrachlordibenzo-IpI-dioxin equivalents (TEQ). The distribution patterns of total PCDD/Fs and 2,3,7,8-substituted PCDD/Fs were elucidated in detail. The TEQ values of toxic PCDD/Fs in all chemicals were in the range of 5.03-1379.55 ng I-TEQ/kg. The contribution of OCDD and OCDF in phthalocyanine green was 75% of the total TEQ. For chloranils, the maximum contribution of toxic PCDD/Fs was from 2,3,7,8-substituted HxCDF and 2,3,7,8-substituted HpCDF. The TEQ of HxCDF and HpCDF in chloranil-1 was 90% and in chloranil-2 was 71%. And the toxic contribution increased with the degree of chlorination for PCDFs.  相似文献   

16.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

17.
Tian B  Huang J  Wang B  Deng S  Yu G 《Chemosphere》2012,89(4):409-415
Emission of unintentionally produced persistent organic pollutants (Unintentional POPs), including polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychorinated biphenyls (PCBs), hexachlorobenzene (HxCBz) and pentachlorobenzene (PeCBz), were investigated in four typical iron ore sintering plants in China. The emission factors and annual mass releases of the Unintentional POPs were calculated. The results indicated that PCDFs contributed more than 60% to the overall toxic equivalent quantity (TEQ) values, while the contribution of the dl-PCBs is relatively low, and only in the range of 8-9%. The dominant congeners of PCDD/Fs and dl-PCBs contributing most to the total TEQ were 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF and PCB-126. With regard to the TEQ contributions, the most abundant homologues were PeCDFs and HxCDD/Fs, followed by PeCDDs and non-ortho dl-PCB, whereas HpCDD/Fs, OCDD/Fs and mono-ortho dl-PCBs almost made no contributions. Due to the massive use of recycled waste in the feeding materials, the average emission factor of PCDD/Fs and dl-PCBs of the four plants was 3.95 μg WHO-TEQ ton−1. Based on the results, the annual release of PCDD/Fs and dl-PCBs in 2007-2009 were estimated to be 2070 g, 2212 g, and 2307 g WHO-TEQ, respectively.  相似文献   

18.
BACKGROUND: To observe the relationship between the PCDD/F and Co-PCB levels in samples of human breast milk and nearby waste incinerators in Tokyo, Japan. METHODS: Breast milk was taken from 240 mothers residing in Tokyo, Japan to measure and analyze the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs; 14 congeners), polychlorinated dibenzofurans (PCDFs; 15 congeners), and coplanar polychlorinated biphenyls (Co-PCBs; 12 congeners) contained in the fat. Individual milk samples (about 50 ml) were obtained from the mothers 30 days after delivery, between the months of June and September in 1999 and 2000. A map of Tokyo was used to measure the distances between each mother's place of residence and the closest public and industrial waste incinerators. RESULTS: The distances to the nearest waste incinerators bore no apparent correlations with the congeners of PCDD/Fs and Co-PCBs. The distances were also uncorrelated with the mean toxic equivalent quantities (TEQs) of PCDD/Fs (the sum of PCDDs and PCDFs), Co-PCBs, and the total PCDD/Fs and Co-PCBs. CONCLUSIONS: Although waste incinerators were the largest source of dioxins in Japan at the time of the study, the dioxins levels of mother's milk bore no apparent relationships with the distances between the mothers' domiciles and the nearest waste incinerators. In this study, several meaningful factors were not taken into account, namely, the wind direction, the level of dioxin emitted from each incinerator, the level of environmental pollution of dioxins, and the average time the mothers stayed at home each day. A full understanding of these points awaits future studies.  相似文献   

19.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

20.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号