1.
Chi KH  Chang SH  Huang CH  Huang HC  Chang MB 《Chemosphere》2006,64(9):1489-1498
Activated carbon adsorption is commonly used to control dioxin-like congener (PCDD/Fs and PCBs) emissions. Partitioning of PCDD/Fs and PCBs between vapor and solid phases and their removal efficiencies achieved with existing air pollution control devices (APCDs) at a large-scale municipal waste incinerator (MWI) and an industrial waste incinerator (IWI) are evaluated via intensive stack sampling and analysis. Those two facilities investigated are equipped with activated carbon injection (ACI) with bag filter (BF) and fixed activated carbon bed (FACB) as major PCDD/F control devices, respectively. Average PCDD/F and PCB concentrations of stack gas with ACI+BF as APCDs are 0.031 and 0.006ng-TEQ/Nm(3), and that achieved with FACB are 1.74 and 0.19ng-TEQ/Nm(3) in MWI and IWI, respectively. The results show that FACB could reduce vapor-phase PCDD/Fs and PCBs concentrations in flue gas, while the ACI+BF can effectively adsorb the vapor-phase dioxin-like congener and collect the solid-phase PCDD/Fs and PCBs in the meantime. Additionally, the results of the pilot-scale adsorption system (PAS) experimentation indicate that each gram activated carbon adsorbs 105-115ng-PCDD/Fs and each surface area (m(2)) of activated carbon adsorbs 10-25ng-PCDD/Fs. Based on the results of PAS experimentation, this study confirms that the surface area of mesopore+macropore (20-200A) of the activated carbon is a critical factor affecting PCDD/F adsorption capacity.  相似文献   

2.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

3.
Wang HC  Hwang JF  Chi KH  Chang MB 《Chemosphere》2007,67(9):S177-S184
The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).  相似文献   

4.
Wang LC  Lee WJ  Tsai PJ  Lee WS  Chang-Chien GP 《Chemosphere》2003,50(9):1123-1129
This study investigated four sinter plants, classified into two categories--with selective catalytic reduction (SCR) (S1, S2 and S3) and without SCR (S4) as its air pollution control device. Polychlorinated dibenzofurans (PCDFs) are dominant in the stack flue gases of sinter plants with and without SCR. The polychlorinated dibenzofurans/polychlorinated dibenzo-p-dioxins (PCDFs/PCDDs) ratio exceeds 1 extremely. The degree of chlorination of the sinter plant without SCR is towards hepta and hexa congeners while that of the sinter plant with SCR is towards penta and hexa congeners. PCDD/Fs are indeed decomposed (75.5% and 69% on ng and ng TEQ bases, respectively) and not only reduced in degree of chlorination. The overall concentration in the stack flue gas of sinter plants with SCR (7.97-14.1 ng/Nm(3); 0.995-2.06 ng TEQ/Nm(3)) is lower than that of the sinter plant without SCR (28.9 ng/Nm(3); 3.10 ng TEQ/Nm(3)). In Taiwan, based on the emission factors of 0.970 microg TEQ/ton-feedstock (sinter plants with SCR) and 3.13 microg TEQ/ton-feedstock (sinter plant without SCR), the annual PCDD/F emission of 44.7 g TEQ/year from sinter plants is 60 and 121 times higher than those from municipal solid waste incinerators (0.750 g TEQ/year) and MWIs (0.369 g TEQ/year). These results show that sinter plants have become the dominating PCDD/F emission source since tighter emission limits have been applied to incinerators.  相似文献   

5.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

6.
Catalytic oxidation of gaseous PCDD/Fs with ozone over iron oxide catalysts   总被引:2,自引:0,他引:2  
Wang HC  Chang SH  Hung PC  Hwang JF  Chang MB 《Chemosphere》2008,71(2):388-397
Catalytic oxidation of PCDD/Fs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans) with ozone (catalytic ozonation) over nano-sized iron oxides (denoted as FexOy) was carried out at temperature of 120-180 degrees C. The effects of operating temperature, ozone concentration, space velocity (SV) and water vapor contents on PCDD/F removal and destruction efficiencies via catalytic ozonation were investigated. High activity of the iron oxide catalyst towards PCDD/F decomposition was observed even at low temperatures with the aid of ozone. The PCDD/F removal and destruction efficiencies achieved with FexOy/O3 at 180 degrees C reach 94% and 91%, respectively. In the absence of ozone, the destruction efficiencies of all PCDD/F congeners are below 20% and decrease with increasing chlorination level of PCDD/F congener at lower temperature (120 degrees C). However, in the presence of ozone, the destruction efficiencies of all PCDD/F congeners are over 80% on FexOy/O3 at 180 degrees C. Higher temperature and ozone addition increase the activity of iron oxide for the decomposition of PCDD/Fs. Additionally, in the presence of 5% water vapor, the destruction efficiency of the PCDD/Fs is above 90% even at lower operating temperature (150 degrees C). It indicates that the presence of appropriate amount of water vapor enhances the catalytic activity for the decomposition of gas-phase PCDD/Fs.  相似文献   

7.
Hung PC  Lo WC  Chi KH  Chang SH  Chang MB 《Chemosphere》2011,82(1):72-77
A laboratory-scale multi-layer system was developed for the adsorption of PCDD/Fs from gas streams at various operating conditions, including gas flow rate, operating temperature and water vapor content. Excellent PCDD/F removal efficiency (>99.99%) was achieved with the multi-layer design with bead-shaped activated carbons (BACs). The PCDD/F removal efficiency achieved with the first layer adsorption bed decreased as the gas flow rate was increased due to the decrease of the gas retention time. The PCDD/F concentrations measured at the outlet of the third layer adsorption bed were all lower than 0.1 ng I-TEQ Nm−3. The PCDD/Fs desorbed from BAC were mainly lowly chlorinated congeners and the PCDD/F outlet concentrations increased as the operating temperature was increased. In addition, the results of pilot-scale experiment (real flue gases of an iron ore sintering plant) indicated that as the gas flow rate was controlled at 15 slpm, the removal efficiencies of PCDD/F congeners achieved with the multi-layer reactor with BAC were better than that in higher gas flow rate condition (20 slpm). Overall, the lab-scale and pilot-scale experiments indicated that PCDD/F removal achieved by multi-layer reactor with BAC strongly depended on the flow rate of the gas stream to be treated.  相似文献   

8.
Sampling and analysis of ambient dioxins in northern Taiwan   总被引:2,自引:0,他引:2  
Chang MB  Weng YM  Lee TY  Chen YW  Chang SH  Chi KH 《Chemosphere》2003,51(10):1103-1110
In this study, ambient air samples were taken concurrently in the vicinity area of a large-scale municipal waste incinerator (MWI) and the background area for measuring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) concentrations from November 1999 through July 2000 in northern Taiwan. The results obtained from eighteen ambient air samples indicate that the mean PCDD/F concentration of seventeen 2,3,7,8-substituted congeners in wintertime (188–348 fg-I-TEQ/m3) is significantly higher than that measured in summertime (56–166 fg-I-TEQ/m3). In addition, the seasonal PCDD/F concentrations are compared with the ambient air quality data including CO, NO2, PM10 and TSP sampled from Taipei area to gain better insights. It indicates that the variation of ambient air PCDD/F concentrations is closely correlated with that of PM10 concentrations. Besides, the results indicate that the I-TEQ concentration of ambient air in sampling site B (directly downwind of the MWI) is of the highest while the sampling site A (upwind of MWI) is of the lowest among all sampling sites. This implies that existing MWI can be a significant emitter of PCDD/Fs in this area. Furthermore, the patterns of the PCDD/F congener distribution at all sampling sites (including the background site in Taoyuan) are quite similar. OCDD concentration is of the highest among seventeen PCDD/F congeners investigated and accounts for about 35% of the total concentration. As for the I-TEQ concentrations, 2,3,4,7,8-PeCDF is the most significant contributor, generally being responsible for 30–45% of the total I-TEQ values depending on the sampling sites and seasons.  相似文献   

9.
Air pollution control devices (APCDs) are not compulsory for medical waste incinerators (MWIs) in developing countries. In South Africa, combustion gases are usually vented directly to the atmosphere at temperatures greater than the formation temperature of dioxin. The possibility of dioxin formation outside the incinerator stack has been hypothesized. A plume model has been developed and tested in the wind tunnel with a scale model of an incinerator stack. The plume temperature and trajectory predictions of the plume model were verified within a +/- 3% experimental accuracy. Using South African data, the plume model predicts that the residence time of gases in the temperature range of 150-450 degrees C in a plume is 1.3 sec on average for 5% of a year (18 days) at meteorological conditions resulting in wind speeds of less than 1 m/sec. Two published dioxin formation models were used to assess the probability of dioxin formation in the plume. The formation models predict that the average polychlorinated dibenzodioxins/furans (PCDD/Fs) formed in the plume will exceed the stack emission regulations in South Africa of 0.2 ng/Nm3 toxic equivalent quotient (TEQ) by between 2 and 40 times. The calculated concentrations do not include additional gaseous PCDD/F compounds that may be formed at high-temperature post-combustion zones through pyrosynthesis mechanisms.  相似文献   

10.
Unintentionally produced persistent organic pollutants (UPOPs) include polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenyls (dl-PCBs), pentachlorobenzene (PeCBz), and hexachlorobenzene (HxCBz). With the booming of municipal waste incinerators (MWIs) in China, the emission of UPOPs has generated great concern. As an alternative technology of dioxin control, catalytic decomposition has not been used in China, mainly due to the absence of national demonstration projects. Also, the simultaneous removal of various UPOPs has not been well investigated.In this study, a pilot-scale selective catalytic oxidative (SCO) system using a self-developed honeycomb catalyst was built and tested in a typical municipal waste incinerator (MWI) of China. The original concentration of PCDD/Fs in flue gas after the treatment of activated carbon injection (ACI) still exceeded the national emission standard (0.1 ng I-TEQ/Nm3), while the concentrations of PeCBz and HxCBz were one order of magnitude higher than that of PCDD/Fs. For the testing temperature varying from 300 to 200 °C, the removal efficiency of PCDD/Fs range from 39 to 95 %, followed by dl-PCBs with the range of 56–89 %. PeCBz and HxCBz were also removed, though their removal efficiencies were lower than those of PCDD/Fs and dl-PCBs. Both temperature and degree of chlorination influence the removal efficiencies.  相似文献   

11.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

12.
Medium- and low-volatile organic chlorine (M/LVOCl) and PCDD/Fs in flue gas from various municipal waste incinerators (MWIs) were monitored. The sample for M/LVOCl was collected in an adsorption tube which was thermally desorbed and the amount of chlorine was measured by atomic emission spectrometry (AES) detection using radiofrequency helium plasma. The helium plasma excited chlorine having an optical emission line of 837.6 nm was monitored. The MVOCl and LVOCl were organic chlorine groups whose boiling points (bp) ranged from 70-120 degrees C and 170-270 degrees C, respectively. The compounds having bp 120-170 degrees C were distributed in two tubes. LVOCl correlated well with PCDD/Fs (ng/Nm3, r=0.81) in a wide range of 0.01-100 ng/Nm3 of PCDD/Fs, while the correlation of LVOCl vs. TEQ was less related (r=0.69). These results agreed with the fact that LVOCl monitored the amount of organic chlorine without molecular structure information, which is critical to toxicity. Since the bp of LVOCl was not identical with that of PCDD/Fs, the regression was effected by the conditions of the gas treatment devices. Because most data of 2001 were collected just after the installation of PCDD/Fs in MWIs, the regression of 2001 was slightly different from that of 2002-2003. Eliminating these initial unsteady data, the regression of LVOCl vs. PCDD/Fs became better, giving r= 0.86. Besides having PCDD/Fs as surrogates, M/LVOCl is valuable as a versatile element-selective organic chlorine monitor to improve thermal process control.  相似文献   

13.
Dioxin contents in fly ash from large-scale MSW incinerators in Taiwan   总被引:6,自引:0,他引:6  
In this study, fly ash samples were collected from three municipal waste incinerators (MWI) in Taiwan. These MWIs investigated are equipped with different air pollution control devices (APCDs). Preliminary results indicated that 2,3,7,8-PCDD/Fs homologue patterns of various types of fly ash were quite similar for all three MWIs. Concentrations of higher-chlorinated congeners of PCDDs and PCDFs were remarkably higher than those of lower-chlorinated congeners. In the case of MSW-A, the PCDD/PCDF ratios of ashes were found in the decreasing order for cyclone, boiler and baghouse. The PCDD/PCDF ratios in various types of fly ash of MWI-B was boiler-A < boiler-B < ESP < boiler-C. As for MSW-C, no obvious trend has been observed for PCDD/PCDF ratio. However, the ratio in boiler ash was higher than that in baghouse ash of MWI-A. The dioxin contents in fly ash would increase as the fly ash passed through APCD zones. In other words, the environmental conditions of APCD may actually cause the increase of the dioxin contents in fly ash. The trend for dioxin contents in fly ash collected from three MSW incinerators investigated was MSW-C < MSW-A < MSW-B.  相似文献   

14.
Chang MB  Huang HC  Tsai SS  Chi KH  Chang-Chien GP 《Chemosphere》2006,62(11):1761-1773
Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/N m3 while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/N m3. The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/N m3 and the TEQ concentration was 0.14 ng I-TEQ/N m3. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60–70%) at both EAFs investigated.  相似文献   

15.
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

16.
Choi KI  Lee DH  Osako M  Kim SC 《Chemosphere》2007,66(6):1131-1137
Wet scrubber is one of the most conventional types of air pollutant control devices (APCDs), which is specially designed to treat dust and acidic gases in the flue gas simultaneously. In spite of its outstanding ability to control them, however, wet scrubbers have been considered as potential contaminant sources that may increase PCDD/DF concentrations in the flue gas. In this study, we investigated the change of PCDD/DF concentrations at the inlets and outlets of seven wet scrubbers, and compared them with other published data. With a multi-regression analysis of dust concentrations and temperature at the inlets and outlets of given wet scrubbers, we developed an empirical model to understand factors dominating the change of PCDD/DF concentrations. As a result, we confirmed that the changes of PCDD/DF concentrations in wet scrubbers are closely related to their concentrations at the inlets, which would usually be determined by the type of APCDs installed upstream of the wet scrubber.  相似文献   

17.
Aliphatic liquid as a basic fuel was incinerated in a laboratory scale pilot plant. Inorganic chlorine and organic chlorine mixed with basic fuel were used as additive chemicals. Sodium chloride (NaCl) and tetrachloroethylene (C2Cl4) were used as the sources of inorganic and organic chlorine. Combustion parameters were adjusted for optimum combustion and, consequently, the amount of particles in flue gases was low. The concentrations of chlorine in flue gases were high enough for possible formation reactions of organic chlorinated compounds in all of the chlorine input tests. An increase in chlorine input did not significantly increase the amounts of highly chlorinated organic compounds, like PCDD/Fs. The main result was that chlorophenol concentrations increased in parallel with organic chlorine input. Comparing organic chlorine to inorganic chlorine tests showed that more highly substituted PCDD/F congeners were formed when organic chlorine was the additive chlorine source. The formation of highly chlorinated organic compounds such as PCDD/Fs requires not only chlorine and aliphatic fuel to be formed, but some catalysts are also needed.  相似文献   

18.
Zhang HJ  Ni YW  Chen JP  Zhang Q 《Chemosphere》2008,70(4):721-730
Optimizing the operating parameters to minimize polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDD/F) emission is the common interest of the municipal solid waste (MSW) incineration industry. In this study, we investigated the distribution of tetra- to octa-CDD/F along the flue gas line in a full-scale reciprocating grate incinerator and evaluated the effects of temperature control and O(2) level on PCDD/F formation. Six runs were laid out and all performed under sufficient burning conditions, in which the combustion efficiency of MSW was more than 99.9%. The total concentration of tetra- to octa-CDD/F measured at the boiler outlet showed an increasing tendency with the increase of boiler outlet temperature (T(B)) from 214 degrees C to 264 degrees C. When flue gas ran across the semi-dry scrubber and cyclone precipitator, in which the temperature varied from 264 degrees C to 162 degrees C, the concentrations of the lower chlorinated dioxins and furans were significantly raised, especially for the TCDF. Increasing O(2) supply from 6.0% to 10.5% essentially led to a higher yield of tetra- to octa-PCDD/F, suggested that under sufficient burning conditions the lower O(2) level was favorable for reducing PCDD/F formation and emission. The variation of O(2) level did not give rise to a systematical change of PCDD/F homologue pattern. For all measurements, the isomer distributions of tetra- to hepta-PCDD/F were more or less the same, nearly independent of variations in the operating conditions and sampling positions. Only the significant increase of the sum of 1,3,7,8-TCDF and 1,3,7,9-TCDF was found in the zone after the boiler section.  相似文献   

19.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

20.
The formation and emission of dioxins in large scale thermal processes   总被引:15,自引:0,他引:15  
Everaert K  Baeyens J 《Chemosphere》2002,46(3):439-448
The paper assesses extensive data of PCDD/F measurements on flue gas emissions from thermal processes, including, e.g. municipal solid waste incinerators (MSWIs), combustors of wood and industrial waste, coal fired powerplants and boilers, ferro and non-ferro processes. Numerous investigators have conducted laboratory experiments to assess the formation mechanisms of PCDD/F. The results, obtained from fixed-bed experiments, have been critically evaluated and indicate that de novo synthesis is the dominant mechanism in actual thermal processes where conditions that favour the precursor formation are not experienced. The analysis of PCDD/F profiles from the large scale thermal processes in general, and MSWIs in particular, supports the dominant role of the de novo synthesis, irrespective of the type of thermal process considered. The PCDF/PCDD ratio exceeds 1 and the degree of chlorination points towards the dominant presence of HpCDD and OCDD within the dioxin group, and of PeCDF, HxCDF and HpCDF within the furan group. Since real-time measurement of PCDD/F is impossible, the correlation of PCDD/F emissions with operating parameters and/or emission levels of other more easily measured pollutants could be a tool in predicting the PCDD/F formation levels. Data of Flemish MSWIs were used to statistically assess such correlations. From an evaluation of the data at a given operating temperature, misleading conclusions can be drawn. Only the effect of temperature is evident. After converting all data at a reference temperature of, e.g. 230 degrees C, PCDD/F concentrations achieve nearly constant values, irrespective of the values of other parameters, thus stressing that the major controlling parameter for the PCDD/F emission is the temperature of the ESP. The PCDD/F concentrations increase with temperature in the range up to 280 degrees C. The ESP temperature should be kept preferably between 180 degrees C and 200 degrees C, where de novo synthesis is reduced and where PCDD/Fs are increasingly adsorbed on the fly ash, in line with the standard temperature dependence of adsorption isotherms.  相似文献   