首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gohlke O  Busch M 《Chemosphere》2001,42(5-7):545-550
The SYNCOM process involves oxygen enrichment of underfire air, recirculation of flue gas and a combustion control system using infrared thermography of the waste layer on the grate. At the demonstration plant in Coburg, operational reliability and plant availability using SYNCOM could be proven under real disposal conditions with a waste throughput of 7 t/h. Oxygen enrichment of the underfire air promotes the destruction of pollutants due to the high oxygen partial pressures and temperatures. This is then reflected in very low residual amounts of organic combustion by-products in the bottom ash and flue gas from the SYNCOM unit. The flue gas concentrations of organic pollutants are reduced, as compared with conventional operation, by over 35% (for CO, total hydrocarbons and PCDD/F) at the boiler outlet. As the flue gas flow is reduced by oxygen enrichment and flue gas recirculation, the resulting reduction in terms of kg of pollutant per Mg of waste is even higher. In the bottom ash, the level of organic residues is reduced, by 45% in the case of loss on ignition and by 55% in the case of TOC and dioxins (I-TE of PCDD/F). This is due to the higher oxygen partial pressures and the fuel bed temperature which is increased by 135 to 1200 degrees C. Other important features of the process include more intense sintering and thus improved immobilization of the bottom ash, as well as reduced flue gas and fly ash flows.  相似文献   

2.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

3.
Polychlorinated dibenzodioxins/furans (PCDD/F) were formed in substantial quantities in a pilot-scale fluidized bed combustor burning salt-laden waste wood, a common fuel for Canadian coastal pulp and paper mills. Formation of PCDD/F increased with increasing chloride content in the feed, and appeared to correlate with the chlorine content in the fly ash. It took a very long time for the ash chlorine content to stabilize, suggesting that chlorine transferred slowly from the flue gas to the ash. The baghouse may contribute largely to formation of the PCDD/F, owing to its temperature range and the potentially long residence time for ash particles. Controlling the baghouse temperature to reduce the PCDD/F formation in the baghouse should be effective in reducing the total emission level. While sulphur addition was found to reduce the emission level by as much as 90%, the emission level was still above the regulated level for the mills burning salt-laden wood under the conditions of the present study. No relation between the emission level and CO concentration in the flue gas was observed.  相似文献   

4.
Using 19 samples of fly ash collected from various MSW incineration facilities, residual carbon was characterized by gasifiable fraction at 450 degrees C (C450), and the correlations with de novo synthesis of PCDD/Fs were experimentally examined. Fly ashes were classified into three groups by the ratio of C450 to total residual carbon. By comparison of CO and CO2 generation patterns with those of reference materials, unburnt carbon of solid waste and activated carbon powder injected into flue gas were identified as a carbon source in fly ash. In the experiment of de novo synthesis of PCDD/Fs, the content of PCDD/F synthesis depended on C450 regardless of the origin of carbon. In addition, the model to predict the content of PCDD/F synthesis, DeltaPCDD/F=0.989.Cu.C450, fitted well with experimental values.  相似文献   

5.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

6.
Catalytic oxidation of gaseous PCDD/Fs with ozone over iron oxide catalysts   总被引:2,自引:0,他引:2  
Wang HC  Chang SH  Hung PC  Hwang JF  Chang MB 《Chemosphere》2008,71(2):388-397
Catalytic oxidation of PCDD/Fs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans) with ozone (catalytic ozonation) over nano-sized iron oxides (denoted as FexOy) was carried out at temperature of 120-180 degrees C. The effects of operating temperature, ozone concentration, space velocity (SV) and water vapor contents on PCDD/F removal and destruction efficiencies via catalytic ozonation were investigated. High activity of the iron oxide catalyst towards PCDD/F decomposition was observed even at low temperatures with the aid of ozone. The PCDD/F removal and destruction efficiencies achieved with FexOy/O3 at 180 degrees C reach 94% and 91%, respectively. In the absence of ozone, the destruction efficiencies of all PCDD/F congeners are below 20% and decrease with increasing chlorination level of PCDD/F congener at lower temperature (120 degrees C). However, in the presence of ozone, the destruction efficiencies of all PCDD/F congeners are over 80% on FexOy/O3 at 180 degrees C. Higher temperature and ozone addition increase the activity of iron oxide for the decomposition of PCDD/Fs. Additionally, in the presence of 5% water vapor, the destruction efficiency of the PCDD/Fs is above 90% even at lower operating temperature (150 degrees C). It indicates that the presence of appropriate amount of water vapor enhances the catalytic activity for the decomposition of gas-phase PCDD/Fs.  相似文献   

7.
Formation and destruction of PCDD/F inside a grate furnace   总被引:1,自引:0,他引:1  
Hunsinger H  Jay K  Vehlow J 《Chemosphere》2002,46(9-10):1263-1272
Formation and destruction of polychlorinated dibenzo-p-dioxins and dibenzofurans PCDD/F during the combustion process was investigated experimentally in a pilot plant. All important process steps like the burnout of the fuel bed on the grate, the burnout of the flue gas inside the combustion chamber, the heat recovery in a boiler as well as influences of the fuel composition are described in detail.

High concentrations especially of PCDF are formed during the burnout of the fuel bed. The formation reaction is mainly influenced by the fuel composition and the burnout characteristic of the fuel bed. Fuels with low chlorine and low metal content (Cu) result only in negligible concentrations of PCDD/F.

Under stable combustion conditions characterized by an excellent flue gas burnout PCDD/F will almost be completely destroyed already inside the combustion chamber. “Cold strands” of unburned flue gas (high CO concentrations) caused by disturbed combustion conditions will result in high concentrations of PCDD and especially of PCDF in the raw gas.

A second place of PCDD/F formation is the well-known boiler section. Here fly ash deposits containing residual carbon (mainly soot particles) are the source for the formation reaction. Under stationary effective combustion conditions, they are dominant for PCDD/F concentrations in the raw gas over a very long period of time.

Stationary efficient flue gas burnout (especially soot) together with effective boiler cleaning will guaranty low concentrations of PCDD/F in the flue gas in front of the flue gas cleaning system.  相似文献   


8.
Modeling the formation of PCDD/F in solid waste incinerators   总被引:1,自引:0,他引:1  
Stanmore BR 《Chemosphere》2002,47(6):565-573
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) appear in unacceptable amounts in the gaseous emissions during the incineration of wastes containing significant quantities of chlorine and metals, such as MSW and medical waste. They are formed both in the gas phase at temperatures above 600 degrees C and on the surface of the solid phase (flyash) in the temperature range 400-225 degrees C. Both the precursor (from existing smaller chlorinated molecules) and de novo (from elemental carbon) routes are involved. An empirically derived global model for their de novo formation on flyash in MSW and medical waste incinerators has now been extended to include the precursor mechanism, and a gas phase formation component, with separate rate expressions for PCDD and PCDF. Homogeneous PCDD formation is governed by the concentration of chlorophenols and PCDF by that of chlorophenols and chlorobenzenes. The result is more complete system which distinguishes between the gas and solid phase contributions to the I-TEQ. An additional step for the adsorption of gaseous PCDD/F back onto the solid phase during cooling suggests this should be minimal in the gas ducts of an incinerator. The extended model has been tested against experimental data collected from a well-controlled pilot incinerator and commercial incinerators, and found to adequately describe the measured outputs. With the model it should be possible to predict the PCDD/F emissions from commercial incinerators, provided that the ash properties and the overall temperature-time profiles are known.  相似文献   

9.
The formation and emission of dioxins in large scale thermal processes   总被引:15,自引:0,他引:15  
Everaert K  Baeyens J 《Chemosphere》2002,46(3):439-448
The paper assesses extensive data of PCDD/F measurements on flue gas emissions from thermal processes, including, e.g. municipal solid waste incinerators (MSWIs), combustors of wood and industrial waste, coal fired powerplants and boilers, ferro and non-ferro processes. Numerous investigators have conducted laboratory experiments to assess the formation mechanisms of PCDD/F. The results, obtained from fixed-bed experiments, have been critically evaluated and indicate that de novo synthesis is the dominant mechanism in actual thermal processes where conditions that favour the precursor formation are not experienced. The analysis of PCDD/F profiles from the large scale thermal processes in general, and MSWIs in particular, supports the dominant role of the de novo synthesis, irrespective of the type of thermal process considered. The PCDF/PCDD ratio exceeds 1 and the degree of chlorination points towards the dominant presence of HpCDD and OCDD within the dioxin group, and of PeCDF, HxCDF and HpCDF within the furan group. Since real-time measurement of PCDD/F is impossible, the correlation of PCDD/F emissions with operating parameters and/or emission levels of other more easily measured pollutants could be a tool in predicting the PCDD/F formation levels. Data of Flemish MSWIs were used to statistically assess such correlations. From an evaluation of the data at a given operating temperature, misleading conclusions can be drawn. Only the effect of temperature is evident. After converting all data at a reference temperature of, e.g. 230 degrees C, PCDD/F concentrations achieve nearly constant values, irrespective of the values of other parameters, thus stressing that the major controlling parameter for the PCDD/F emission is the temperature of the ESP. The PCDD/F concentrations increase with temperature in the range up to 280 degrees C. The ESP temperature should be kept preferably between 180 degrees C and 200 degrees C, where de novo synthesis is reduced and where PCDD/Fs are increasingly adsorbed on the fly ash, in line with the standard temperature dependence of adsorption isotherms.  相似文献   

10.
Jin GZ  Lee SJ  Kang JH  Chang YS  Chang YY 《Chemosphere》2008,70(9):1568-1576
Polyethylene (PE) and polyvinyl chloride (PVC) are the leading plastics in total production in the world. The incineration of plastic-based materials forms many chlorinated compounds, such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). In this study the addition of goethite (alpha-FeOOH) was investigated to determine its suppressing effect on the emission of PCDD/Fs and hexachlorobenzene (HCB) during the combustion of wastes containing PE and PVC. Goethite was being considered since it acts as a dioxin-suppressing catalyst during incineration. Results showed that incorporation of goethite greatly reduced the generation of PCDD/Fs and HCB in the exhaust gas and fly ash. The concentration of PCDD/Fs in flue gas decreased by 45% for lab-scale and 52% for small incinerator combustion experiments, where the goethite ratios in feed samples were 0.54% and 0.34%, respectively. Under the same conditions, the concentration of HCB in flue gas decreased by 88% and 62%, respectively. The present study showed a possible mechanism of the suppressing effect of the goethite for PCDD/F formation. It is likely that iron chlorides react with particulate carbon to form organo-chlorine compounds and promote PCDD/F formation in the gas phase. XRD analysis of combustion ash revealed that the goethite was partially dehydrated and converted to alpha-Fe(2)O(3) and Fe(3)O(4) but no iron chlorides formation. Therefore the goethite impregnated plastics can contribute the reduction of PCDD/Fs and HCB in the exhaust gas during incineration of MSW.  相似文献   

11.
Hung PC  Lo WC  Chi KH  Chang SH  Chang MB 《Chemosphere》2011,82(1):72-77
A laboratory-scale multi-layer system was developed for the adsorption of PCDD/Fs from gas streams at various operating conditions, including gas flow rate, operating temperature and water vapor content. Excellent PCDD/F removal efficiency (>99.99%) was achieved with the multi-layer design with bead-shaped activated carbons (BACs). The PCDD/F removal efficiency achieved with the first layer adsorption bed decreased as the gas flow rate was increased due to the decrease of the gas retention time. The PCDD/F concentrations measured at the outlet of the third layer adsorption bed were all lower than 0.1 ng I-TEQ Nm−3. The PCDD/Fs desorbed from BAC were mainly lowly chlorinated congeners and the PCDD/F outlet concentrations increased as the operating temperature was increased. In addition, the results of pilot-scale experiment (real flue gases of an iron ore sintering plant) indicated that as the gas flow rate was controlled at 15 slpm, the removal efficiencies of PCDD/F congeners achieved with the multi-layer reactor with BAC were better than that in higher gas flow rate condition (20 slpm). Overall, the lab-scale and pilot-scale experiments indicated that PCDD/F removal achieved by multi-layer reactor with BAC strongly depended on the flow rate of the gas stream to be treated.  相似文献   

12.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

13.
Pandelova M  Lenoir D  Schramm KW 《Chemosphere》2006,62(7):1196-1205
In the flue gas of co-combustion of solid waste and coal in a laboratory scale furnace high concentrations of polychlorinated dibenzo-p-dioxin and furans (PCDD/F), polychlorinated biphenyls (PCB) and polychlorinated benzenes (PCBz) have been detected. These toxic emissions have been reduced by the help of various inhibitors added to fuel before incineration. Knowledge of the congener pattern and homologue profiles of PCDD/F, PCB and PCBz is important to elaborate the mechanism of formation and inhibition of the toxic compounds formed during co-combustion of solid waste and coal. Principle component analysis (PCA) is used in order to find the similarity between the samples and separate them according their toxicity. By the help of the component analysis (CA) the best correlated congeners are effectively detected. Using linear regression between the independent variables and the indicator parameters various good correlated pairs between PCDD/F, PCB and PCBz have been elaborated. Generally it was found that the samples with higher toxicity show a good correlation between tetra- and pentachlorinated benzenes and tetra- and pentachlorinated dibenzo-p-furans. The best indicator parameter for PCDD/F World Health Organization toxic equivalent (WHO-TEQ) among the PCBz congeners investigated is 1,2,4,5-TCBz. This isomer is also significantly correlated with PCDD/F WHO-TEQ and with the sum of PCDD/F WHO-TEQ and PCB WHO-TEQ. However for samples with higher percentage of inhibitors the above mentioned relationship between the surrogate and WHO-TEQ disappeared. The PCB homologues and congeners show no correlation with PCBz and PCDD/F homologues and congeners.  相似文献   

14.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

15.
PCDD/Fs are one of the most studied molecules in the world because of their toxicity. In the last years the toxicity of these compounds has been analyzed in details. For years PCDD/F inventories have pointed out the significant role of municipal solid waste (MSW) incinerators in the overall balance. Recently, thanks to new regulations on PCDD/F emissions, in a few countries this scenario is changing: it can be demonstrated that modern MSW incinerators can play a secondary role even if the percentage of MSW sent to combustion has increased. In the latest inventories an unconventional source of PCDD/F has appeared: in nineties some biogas characterizations have demonstrated that there is a release of PCDD/F from MSW sanitary landfills. In addition, the combustion of collected biogas can generate not negligible amounts of PCDD/F. A new question can be put: does the MSW contribute with other management options to the overall balance of PCDD/F? The present work points out that a detailed inventory should take into account also the PCDD/F release from bio-mechanical treatment plants (both composting and bio-drying/bio-stabilization plants). However the contribution from this option is secondary when it is compared with the one from old MSW incinerators.  相似文献   

16.
Urea as a PCDD/F inhibitor in municipal waste incineration   总被引:2,自引:0,他引:2  
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at approximately 730 degrees C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

17.
One option of recycling used contaminated packaging is to recover its high energy content. This can be performed in a normal multi-fuel power plant by co-combustion of packaging-derived fuel (PDF) or refuse-derived fuel (RDF) with fossil fuels, such as coal or peat. This work includes the results of 17 co-combustion tests and an evaluation of the results by the Principal Component Analysis (PCA) and the Partial Least Squares Projections to Latent Structures (PLS). PCA and PLS calculations showed that especially Pb, but also Cr, and Cu correlated with lower chlorinated furans (PCDFs) in the fly ash. Correlation between Sn and lower chlorinated dioxins (PCDDs) in the fly ash was also noticed. CO and PAH emission in the flue gas correlated with total PCDD/Fs in the flue gas. In a real full-scale combustion process, a single parameter in fuel, flue gas or a combustion parameter did not provide a guide to PCDD/F formation or to a level of the total PCDD/F emission, but correlations between different parameters and PCDD/Fs could be found. Although PDFs and RDF had catalytic heavy metals and chlorine, the co-combustion results showed that they can be co-combusted with peat and coal in a fluidized-bed boiler at least up to 26 % with very low total PCDD and PCDF emissions.  相似文献   

18.
The data on dioxin and furan emissions revealed, based on individual analysis for 2,3,7,8-TCDD, TCDD, 2,3,7,8-TCDF and TCDF for the six test periods and the operation of the two RDF-fired boilers, that there is no apparent consistent relationship between the dioxin and furan emissions and the individual or combined (averaged) boiler steam flow, total flue gas flow, sidewall furnace temperature, furnace temperature at 2-second residence time, or total furnace residence time at this plant. Only RDF feeder balance begins to show a correlation. However, there was a difference between RDF-natural gas firing and RDF-only firing; the RDF-only firing had lower PCDD and PCDF emissions while consistently operating at lower excess air.

The dioxin and furan emissions from this testing are comparable to the low end of the range of these emissions measured by the U.S. EPA at resource recovery plants in the past 4 years. This may be due in part to the calculated average furnace retention of 4 to 5 seconds during Tests #4–6, with average furnace temperatures at 2-second residence time from 1650°F to 1750°F. However, there was no correlation between dioxin and furan emissions in the stack and individual boiler operation, as judged by the average concentrations of O2, CO, CO2, 1-CO/CO2), NOx, HCl, SO2, or TSP, and furnace upset conditions versus normal operation as judged by instantaneous steam flow, sidewall furnace temperature, O2, CO, NOx, or SO2.  相似文献   


19.
Thirteen samples of human adipose tissue from cancer patients in Japan were analyzed for tetra- to octa- chlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). These compounds were identified in all the samples analyzed. All isomers identified have a pattern of chlorine substitution in 2, 3, 7 and 8 positions with the only exception of 1,2,3,4,6,7,9-hepta-CDD. In the case of PCDFs, the relatively higher persistency was found in the isomers with chlorine atoms at 4- (or 6-) position as compared with 1- (or 9-) position. Total PCDD concentrations were in the range of 160 to 1400 pg/g on wet weight basis, in which increasing levels were found from tetra- to octa-CDD. Total PCDF concentrations were in the range of 7 to 120 pg/g and the levels of individual congeners are rather uniform.  相似文献   

20.
The effect of reaction time on formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) was studied under laboratory conditions in the system containing municipal waste incineration fly ash, activated carbon and copper chloride dihydrate at 300 degrees C in 99.999% N2 and N2 + 10% O2 atmosphere. The concentrations of tetra- to octa-chlorinated isomers as well as I-TEQ concentrations of toxic congeners are reported. The mechanism of PCDD and PCDF formation from chlorophenols and chlorinated biphenyls is discussed in the light of the time changes of PCDD/PCDF ratios.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号