首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Li Z 《Chemosphere》2004,54(3):419-423
Oxidative dechlorination of chlorinated solvents by permanganate is an emerging technology for remediation of groundwater contaminated with dissolved chlorinated contaminants. In this study, the enhancement of trichloroethylene (TCE) degradation by permanganate in aqueous solution in the presence of surfactant was evaluated through a continuous stir batch reactor system with the presence of permanganate as the limiting reagent and free phase TCE. The TCE degradation was determined by continuous monitoring the amount of chloride produced, which was then reverted to the rate of permanganate consumption. It was found that the chloride production, an indication of TCE degradation, followed a pseudo-first-order reaction kinetics with respect to KMnO(4) in the presence of free phase TCE. When no surfactants were present, the observed pseudo-first-order rate constant (k(obs)) was 0.08-0.19 min(-1) and the half-life (t(1/2)) was 4-9 min for MnO(4)(-). When the surfactant concentration was less than its critical micelle concentration (CMC), the k(obs) values increased to 0.42-0.46 min(-1) and the t(1/2) reduced to 1.5-1.7 min for MnO(4)(-). As the surfactant concentration was greater than the CMC, the k(obs) values increased to 0.56-0.58 min(-1) and the t(1/2) reduced to 1.2-1.3 min. The preliminary results showed that combination of permanganate with a proper type of surfactant can speed up contaminant removal.  相似文献   

2.
Tetrakis-(4-sulfonatophenyl)porphyrin cobalt was identified as a highly-active reductive dechlorination catalyst for chlorinated ethylenes. Through batch reactor kinetic studies, degradation of chlorinated ethylenes proceeded in a step-wise fashion with the sequential replacement of Cl by H. For perchloroethylene (PCE) and trichloroethylene (TCE), the dechlorination products were quantified and the C2 mass was accounted for. Degradation of the chlorinated ethylenes was found to be first-order in substrate. Dechlorination trials with increasing catalyst concentration showed a linearly increasing pseudo first-order rate constant which yielded rate laws for PCE and TCE degradation that are first-order in catalyst. The dechlorination activity of this catalyst was compared to that of another water-soluble cobalt porphyrin under the same reaction conditions and found to be comparable for PCE and TCE.  相似文献   

3.
Al-Abed SR  Fang Y 《Chemosphere》2006,64(3):462-469
Electrolytic dechlorination using a granular-graphite packed cathode is an alternative method for the remediation of chlorinated organic compounds. Its effectiveness under various conditions needs experimental investigation. Dechlorination of trichloroethylene (TCE) was conducted under various conditions in an electrolytic reactor with a platinum-gauze anode and a granular-graphite packed cathode. The higher the applied current, the more TCE was eliminated and more hydrogen and oxygen gasses were generated. Current efficiency decreased with a decrease in TCE concentration during each dechlorination experiment. But, the current efficiency concentration coefficient (CECC), which was defined as current efficiency divided by concentration, was a better indicator of current efficiency. The CECC was not significantly affected by current, but it varied with pH value. The pH effects were results of the involvement of electrolytes in the proton reduction and the electron transfer at the cathode. A lower pH value favored TCE dechlorination in potassium chloride, which is an electrolyte that was not involved in cathode reactions with protons and electrons. In ammonium acetate and potassium nitrate, which involve proton reduction and/or electron transfer, the pH value affected TCE dechlorination through proton limitation and electron competition.  相似文献   

4.
Che H  Lee W 《Chemosphere》2011,82(8):1103-1108
Selective redox degradation of chlorinated aliphatics by Fenton reaction in pyrite suspension was investigated in a closed system. Carbon tetrachloride (CT) was used as a representative target of perchlorinated alkanes and trichloroethylene (TCE) was used as one of highly chlorinated alkenes. Degradation of CT in Fenton reaction was significantly enhanced by pyrite used as an iron source instead of soluble Fe. Pyrite Fenton showed 93% of CT removal in 140 min, while Fenton reaction with soluble Fe(II) showed 52% and that with Fe(III) 15%. Addition of 2-propanol to the pyrite Fenton system significantly inhibited degradation of TCE (99% to 44% of TCE removal), while degradation of CT was slightly improved by the 2-propanol addition (80-91% of CT removal). The result suggests that, unlike oxidative degradation of TCE by hydroxyl radical in pyrite Fenton system, an oxidation by the hydroxyl radical is not a main degradation mechanism for the degradation of CT in pyrite Fenton system but a reductive dechlorination by superoxide can rather be the one for the CT degradation. The degradation kinetics of CT in the pyrite Fenton system was decelerated (0.13-0.03 min−1), as initial suspension pH decreased from 3 to 2. The formation of superoxide during the CT degradation in the pyrite Fenton system was observed by electron spin resonance spectroscopy. The formation at initial pH 3 was greater than that at initial pH 2, which supported that superoxide was a main reductant for degradation of CT in the pyrite Fenton system.  相似文献   

5.
A two-stage methanotrophic bioreactor system was developed for remediation of water contaminated with TCE and other chlorinated, volatile, aliphatic hydrocarbons. The first stage of the reactor was a suspended-growth culture vessel using a bubbleless methane-transfer device. The second stage was a plug-flow bioreactor supplied with contaminated groundwater and cell suspension from the culture vessel. The test objectives were to determine the applicability of microbial culture conditions reported in the literature for continuous, pilot-scale TCE treatment; the technical feasibility of plug-flow bioreactor design for treatment of TCE; and the projected economic competitiveness of the technology considering the cost of methane for growth of methanotrophs. The methanotrophic organism used in the study was Methylosinus trichosporium OB3b. Information on system operation was obtained in bench tests prior to conducting the pilot tests. In bench- and pilot-scale tests, variability in the degree of TCE degradation and difficulty in maintaining the microbial culture activity led to short periods of satisfactory biotreatment. Further development of the microbial culture system will be required for long-term operation. During transient periods of high TCE degradation activity, the bioreactor concept proved feasible by exhibiting both a high degree of TCE biodegradation (typically about 90% at influent TCE concentrations of 0.5-4 ppm) and a close approximation to first-order reactor kinetics throughout the length of the reactor. Actual methane usage in the pilot-scale reactor resulted in projected methane costs of $0.33 per 1000 gallons of water treated. This cost theoretically would be reduced by system modifications. The theoretical minimum methane cost was approximately $0.05 per 1000 gallons.  相似文献   

6.
将零价铁(Fe0)、沸石等活性材料附着在电极上形成可渗透反应层并构成可渗透反应复合电极,采用不同的复合电极对Cd2+、Ni 2+、Pb2+和Cu2+等4种阳离子型重金属污染土壤进行了电动力学修复。研究了不同可渗透反应复合电极对土壤pH的控制效果以及对重金属的去除作用,分析了迁移到复合电极中的重金属形态变化。结果表明,复合电极中添加酸、碱性沸石并适时更换,可有效中和、截留阴阳极电解产生的OH-和H+,避免或减缓土壤酸碱迁移带的形成,防止重金属离子的过早沉淀及土壤过度酸化,极大提高了重金属的去除率。复合电极中Fe0可将迁移进来的重金属离子进行还原稳定,实现重金属污染物的捕获与固定,与迁移到沸石复合电极中的4种重金属不稳定态相比,"Fe0+沸石"复合电极中重金属不稳定态分别下降了61.4、60.5、61.4、57.1百分点。结果还显示,阴极采用"Fe0+沸石"复合电极并适时进行更换,施加1.5V/cm的直流电压修复10d后,土壤中Cd、Ni、Pb、Cu的总去除率分别为44.5%、41.5%、33.5%和36.7%,且进一步延长修复时间和持续更换电极可获得更为理想的修复效果。  相似文献   

7.
分别用3种不同材料电极(不锈钢、Ti/Pt和Ti/RuO2-IrO2)作阳极、石墨电极作阴极在同一条件下分别对循环式准好氧填埋垃圾场渗滤液进行电解处理对比研究.研究结果表明,随着电解时间的变化,渗滤液中的COD、BOD5、BOD5/COD、重金属离子浓度、色度和pH值均会发生改变.当电解时间为10~20 min时,用上述3种电极作阳极电解均会出现渗滤液COD、BOD5、BOD5/COD增大的现象;当电解时间为30~40 min时,用Ti/RuO2-IrO2或Ti/Pt电极作阳极电解均可使渗滤液的色度降为0;当电解时间为120 min时,分别用3种电极作阳极电解都可使渗滤液中的COD、BOD5和重金属得到有效的去除,其中用Ti/RuO2-IrO2电极作阳极电解对COD、BOD5的去除效果最好:用Ti/Pt电极作阳极电解对Pb2 的去除效果最好.  相似文献   

8.
The electrolysis of some chlorinated organic compounds such as chloroacetic acids, chloromethanes and chloroethenes were carried out on a photo-irradiated n-TiO(2) electrode applied a constant potential, 1.0 V vs. Ag/AgCl, and the alternated pulse potentials of +1.0 V and various negative potentials, -1.0, -1.2 and -1.4V vs. Ag/AgCl in 0.1 mol dm(-3) Na(2)SO(4) solutions saturated with oxygen or with nitrogen. These compounds were degraded on the n-TiO(2) electrode by the photo-electrolysis and mineralized to carbon dioxide, carbon monoxide and chloride ion. When the alternated pulse potentials were applied, the mineralization yields were increased for these compounds, especially for trichloroacetic acid and carbon tetrachloride, both of which were comparatively stable to the degradation in the constant potential electrolysis. The presence of oxygen in the solution was effective for the mineralization of these compounds, while little effective for that of trichloroacetic acid and of carbon tetrachloride.  相似文献   

9.
Reductive dechlorination of trichloroethene (TCE) by zero-valent iron produces a systematic enrichment of 13C in the remaining substrate that can be described using a Rayleigh model. In this study, fractionation factors for TCE dechlorination with iron samples from two permeable reactive barriers (PRBs) were established in batch experiments. Samples included original unused iron as well as material from a barrier in Belfast after almost 4 years of operation. Despite the variety of samples, carbon isotope fractionations of TCE were remarkably similar and seemed to be independent of iron origin, reaction rate, and formation of precipitates on the iron surfaces. The average enrichment factor for all experiments was -10.1 per thousand (+/- 0.4 per thousand). These results indicate that the enrichment factor provides a powerful tool to monitor the reaction progress, and thus the performance, of an iron-reactive barrier over time. The strong fractionation observed may also serve as a tool to distinguish between insufficient residence time in the wall and a possible bypassing of the wall by the plume, which should result in an unchanged isotopic signature of the TCE. Although further work is necessary to apply this stable isotope method in the field, it has potential to serve as a unique monitoring tool for PRBs based on zero-valent iron.  相似文献   

10.
不同电极降解2-氯苯酚   总被引:1,自引:0,他引:1  
采用电沉积法制备了4种钛基二氧化铅电极,并与商业化的钛基RuO2电极进行了对比。分别用XRD和阳极极化曲线对电极性能进行了表征,并以2-氯苯酚为目标污染物,考察了6种电极的电催化氧化性能。研究结果表明,以钛板为基体的系列电极的综合性能优于以钛网为基体的相应电极。以β-PbO2为活性外层的二氧化铅电极的综合性能优于以RuO2为活性外层的电极。6种电极对2-氯苯酚降解反应均遵循一级反应动力学规律。其中Ti/α-PbO2/β-PbO2电极析氧电位最高,电催化性能最好,对2-氯苯酚的去除率可达99.3%。  相似文献   

11.
以钛基氧化物涂层材料(Ti/SnO2-Sb2O5-IrO2)为阳极,碳纳米管修饰的石墨(GE—CNT)为阴极构建电化学系统进行硝酸根(NO3-)去除研究,考察了阴极材料、阴极电位和pH值对电化学法去除水中NO[的影响,同时检测了铵离子(NH4+)和亚硝酸根(NO2-)的生成量。结果表明,利用碳纳米管修饰的石墨阴极可获得较好的硝态氮去除效果;随着阴极电位负移,NO3-去除率随之升高;酸性条件下NO3-去除率最高,NH;生成量也更多。对于由NO3-转化产生的NH4+,在氯离子存在条件下再次进行电化学处理120min,其去除率可达97.1%。  相似文献   

12.
Stable carbon isotopic analysis, in combination with compositional analysis, was used to evaluate the performance of an iron permeable reactive barrier (PRB) for the remediation of ground water contaminated with trichloroethene (TCE) at Spill Site 7 (SS7), F.E. Warren Air Force Base, Wyoming. Compositional data indicated that although the PRB appeared to be reducing TCE to concentrations below treatment goals within and immediately downgradient of the PRB, concentrations remained higher than expected at wells further downgradient (i.e. >9 m) of the PRB. At two wells downgradient of the PRB, TCE concentrations were comparable to upgradient values, and delta13C values of TCE at these wells were not significantly different than upgradient values. Since the process of sorption/desorption does not significantly fractionate carbon isotope values, this suggests that the TCE observed at these wells is desorbing from local aquifer materials and was present before the PRB was installed. In contrast, three other downgradient wells show significantly more enriched delta13C values compared to the upgradient mean. In addition, delta13C values for the degradation products of TCE, cis-dichloroethene and vinyl chloride, show fractionation patterns expected for the products of the reductive dechlorination of TCE. Since concentrations of both TCE and degradation products drop to below detection limit in wells within the PRB and directly below it, these downgradient chlorinated hydrocarbon concentrations are attributed to desorption from local aquifer material. The carbon isotope values indicate that this dissolved contaminant is subject to local degradation, likely due to in situ microbial activity.  相似文献   

13.
Feng Y  Cui Y  Logan B  Liu Z 《Chemosphere》2008,70(9):1629-1636
The performance of electrodes for the electro-catalytic decomposition of a model pollutant (phenol) was enhanced using Gd-doped Ti/SnO(2)-Sb electrodes prepared by a thermal deposition method. Phenol degradation followed first-order rate kinetics, with the maximum rate achieved using a 2% Gd doping level (molar ratio based on Gd:Sn) for tests conducted over a doping range of 1-10%. The first-order rate constant with 2% Gd was 0.044 min(-1), versus 0.026 min(-1) obtained with the control (plain Ti/SnO(2)-Sb). TOC removal and UV scans revealed that different intermediates were produced for different Gd contents, and that destruction efficiencies of these intermediates also varied with Gd doping levels of 1-5%. Electrodes were characterized by scanning electron microscopy, X-ray diffraction, electron dispersive spectrometry, and X-ray photon-electron spectroscopy. It is suggested that the state of specific active sites on the electrode surface and the oxygen transfer activity at the electrode/electrolyte interface affect the performance of anodes with different compositions.  相似文献   

14.
Lee W  Batchelor B 《Chemosphere》2004,56(10):999-1009
Abiotic reductive dechlorination of chlorinated ethylenes (tetrachloroethylene (PCE), trichloroethylene (TCE), cis-dichloroethylene (c-DCE), and vinylchloride (VC)) by iron-bearing phyllosilicates (biotite, vermiculite, and montmorillonite) was characterized to obtain better understanding of the behavior of these contaminants in systems undergoing remediation by natural attenuation and redox manipulation. Batch experiments were conducted to evaluate dechlorination kinetics and some experiments were conducted with addition of Fe(II) to simulate impact of microbial iron reduction. A modified Langmuir-Hinshelwood kinetic model adequately described reductive dechlorination kinetics of target organics by the iron-bearing phyllosilicates. The rate constants stayed between 0.08 (+/-10.4%) and 0.401 (+/-8.1%) day(-1) and the specific initial reductive capacity of iron-bearing phyllosilicates for chlorinated ethylenes stayed between 0.177 (+/-6.1%) and 1.06 (+/-7.1%) microM g(-1). The rate constants for the reductive dechlorination of TCE at reactive biotite surface increased as pH (5.5-8.5) and concentration of sorbed Fe(II) (0-0.15 mM g(-1)) increased. The appropriateness of the model is supported by the fact that the rate constants were independent of solid concentration (0.0085-0.17 g g(-1)) and initial TCE concentration (0.15-0.60 mM). Biotite had the greatest rate constant among the phyllosilicates both with and without Fe(II) addition. The rate constants were increased by a factor of 1.4-2.5 by Fe(II) addition. Between 1.8% and 36% of chlorinated ethylenes removed were partitioned to the phyllosilicates. Chloride was produced as a product of degradation and no chlorinated intermediates were observed throughout the experiment.  相似文献   

15.
Biodegradation of trichloroethene (TCE) near a Dense Non Aqueous Phase Liquid (DNAPL) can enhance the dissolution rate of the DNAPL by increasing the concentration gradient at the DNAPL-water interface. Two-dimensional flow-through sand boxes containing a TCE DNAPL and inoculated with a TCE dechlorinating consortium were set up to measure this bio-enhanced dissolution under anaerobic conditions. The total mass of TCE and daughter products in the effluent of the biotic boxes was 3-6 fold larger than in the effluent of the abiotic box. However, the mass of daughter products only accounted for 19-55% of the total mass of chlorinated compounds in the effluent, suggesting that bio-enhanced dissolution factors were maximally 1.3-2.2. The enhanced dissolution most likely primarily resulted from variable DNAPL distribution rather than biodegradation. Specific dechlorination rates previously determined in a stirred liquid medium were used in a reactive transport model to identify the rate limiting factors. The model adequately simulated the overall TCE degradation when predicted resident microbial numbers approached observed values and indicated an enhancement factor for TCE dissolution of 1.01. The model shows that dechlorination of TCE in the 2D box was limited due to the short residence time and the self-inhibition of the TCE degradation. A parameter sensitivity analysis predicts that the bio-enhanced dissolution factor for this TCE source zone can only exceed a value of 2 if the TCE self-inhibition is drastically reduced (when a TCE tolerant dehalogenating community is present) or if the DNAPL is located in a low-permeable layer with a small Darcy velocity.  相似文献   

16.
Lin CJ  Liou YH  Lo SL 《Chemosphere》2009,74(2):314-319
A Pd/Sn bimetallic nanoparticles resin (nano-Pd/Sn/resin) was successfully synthesized for reductive transformation of aqueous trichloroethylene (TCE). The physicochemical properties of the prepared resin were characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, N(2) isothermal sorption at and X-ray photospectroscopy. The surface-area-normalized rate constants (k(SA)) of Sn particles in the nanoscale range (50-100 nm) were 4.5 times larger than the k(SA) for powdered Sn (0.04 mm). After depositing 1 wt% Pd onto nano-Sn surface, k(SA) was further enhanced by about a factor of 2. Groundwater constituents such as sulfide nitrate and dissolved oxygen had significant negative effects on the rate of TCE degradation by the nano-Pd/Sn/resin. A wet-chemical method regeneration method was observed to effectively restore the reactivity of the poisoned nano-Pd/Sn/resin after dipping in sulfide solution for 2d. In all cases, less than 0.5% of the degraded TCE appeared as chlorinated byproducts including the three dichloroethene isomers. The nano-Pd/Sn/resin technique performs well in transforming TCE into nontoxic hydrocarbons, as compared with other published methods.  相似文献   

17.
为有效处理含异噁草酮除草剂废水,以Sb掺杂Ti/SnO2电极为阳极,不锈钢板为阴极,采用电催化氧化技术对异噁草酮废水进行降解,研究了不同影响因素对异噁草酮去除率的影响,并分析了异噁草酮的降解效果。结果表明,当异噁草酮初始浓度为100mg/L、电流密度为20mA/cm2、电解质投加量为0.10mol/L,反应120min后,异噁草酮去除率达到94%,此时TOC去除率为57.9%,能耗为25kWh/m2,且废水的可生化性能显著提高。  相似文献   

18.
Parshetti GK  Doong RA 《Chemosphere》2012,86(4):392-399
In this study, the dechlorination of chlorinated hydrocarbons including trichloroethylene (TCE), tetrachloroethylene (PCE) and carbon tetrachloride (CT) by bimetallic Ni/Fe nanoparticles immobilized on four different membranes was investigated under anoxic conditions. Effects of several parameters including the nature of membrane, initial concentration, pH value, and reaction temperature on the dechlorination efficiency were examined. The scanning electron microscopic images showed that the Ni/Fe nanoparticles were successfully immobilized inside the four membranes using polyethylene glycol as the cross-linker. The agglomeration of Ni/Fe were observed in poly(vinylidene fluoride), Millex GS and mixed cellulose ester membranes, while a relatively uniform distribution of Ni/Fe was found in nylon-66 membrane because of its hydrophilic nature. The immobilized Ni/Fe nanoparticles exhibited good reactivity towards the dechlorination of chlorinated hydrocarbons, and the pseudo-first-order rate constant for TCE dechlorination by Ni/Fe in nylon-66 were 3.7-11.7 times higher than those in other membranes. In addition, the dechlorination efficiency of chlorinated hydrocarbons followed the order TCE > PCE > CT. Ethane was the only end product for TCE and PCE dechlorination, while dichloromethane and methane were found to be the major products for CT dechlorination, clearly indicating the involvement of reactive hydrogen species in dechlorination. In addition, the initial rate constant for TCE dechlorination increased upon increasing initial TCE concentrations and the activation energy for TCE dechlorination by immobilized Ni/Fe was 34.9 kJ mol−1, showing that the dechlorination of TCE by membrane-supported Ni/Fe nanoparticles is a surface-mediated reaction.  相似文献   

19.
掺硼金刚石薄膜电极在水处理中应用的研究进展   总被引:3,自引:0,他引:3  
掺硼金刚石(BDD)薄膜电极作为一种新型的电极材料,在水溶液中电解时具有较宽的电位窗口,在浓酸浓碱中具有很好的耐腐蚀性,其表面不易吸附污染物,与它的同素异构体电极及其他普通电极相比,具有更好的化学、物理性能,从而表现出潜在的功能,近年来被科研人员用于废水处理,并取得了很好的处理效果,对近期BDD薄膜电极的制备、在污水处理中的应用及其进展进行了总结与讨论.  相似文献   

20.
Over the last few decades, electrostatic precipitators (ESPs) have emerged as effective air pollution control devices for treating coal-fired power plant exhausts. Among the components of the ESP, the discharge electrodes are extremely important in determining the collection efficiency of the ESP. Typically, in wet ESPs, the discharge electrodes used must be made of corrosion-resistant alloys, which makes them extremely expensive and heavy. Hybrid composite discharge electrodes have the potential to be lightweight and corrosion-resistant substitute for traditional metal alloy electrodes used in wet ESPs. In this experimental study, a novel hybrid composite electrode (recently patented at Ohio University) is presented as a substitute for traditional metal electrodes in wet ESPs. The samples of hybrid electrodes were fabricated by using carbon fiber composites, combined with metal mesh, in the shape of a long and thin tape. The electrode’s electrical response was evaluated in open atmospheric conditions, while connected to a transformer-rectifier unit to generate a corona current at voltages exceeding 50 kV. Results of these hybrid electrodes were compared with traditional metal electrodes. The hybrid composite discharge electrode produced a uniform corona at comparable power levels to that of metal electrodes, with additional advantages of being compact, lightweight, and highly corrosion resistant. In addition, hybrid composite electrodes exhibited lower corona onset voltage as compared with metal electrodes. The preliminary experimental data are encouraging and show significant potential for this new inexpensive hybrid electrode to replace metal electrodes in wet ESPs, providing comparable (and in some cases exceeding) collection efficiencies with lower ozone generation.

Implications: The newly invented hybrid composite electrode (HCE) performance was evaluated through experimentation with conventional metal electrodes. The HCE performance was comparable to the metal electrodes. The HCE also exhibited uniform corona fields and steady power while maintaining similar and in some cases superior electrical performance as compared with metal electrodes and thus shows a significant potential to substitute metal electrodes in wet ESP systems.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏