首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
A sampling and analysis method for PAH from two-stroke engines is described. The method, which uses a standard glass fiber filter with a back-up section of Amberlite XAD-2 for sampling and GC or GC-MS for analysis, is suitable for both emission studies and occupational studies during logging. Filters and XAD-2 are desorbed with cyclohexane in an ultrasonic bath. After separation on a silica-gel micro column, the samples are submitted to analyses by capillary GC. The method is simple and covers both gaseous and particulate PAH. Naphthalene and alkyl substituted naphthalenes are also quantified.  相似文献   

2.
Simpson SL  Burston VL  Jolley DF  Chau K 《Chemosphere》2006,65(11):2401-2410
The usefulness of two surrogate methods for rapidly determining the bioavailability of PAHs in hydrocarbon-contaminated marine sediments was assessed. Comparisons are made between the PAHs accumulated by the benthic bivalve, Tellina deltoidalis, and the extractable-PAHs determined using a 6-h XAD-2 resin desorption method and a 4-h gut fluid mimic (GFM) extraction method. There were significant positive relationships between PAH bioaccumulation by the bivalves and sediment PAH concentrations. These relationships were not improved by normalising the sediment PAH concentrations to the organic carbon concentration. The average percentage lipid content of the bivalves was 1.47 ± 0.22% and BSAFs for total-PAHs ranged from 0.06 to 0.80 (kg OC/kg lipid). The XAD-2 and GFM methods both extracted varying amounts of PAHs from the sediments. Low concentrations of PAHs were extracted by the GFM method (0.2–3.6% of total-PAHs in sediments) and the GFM results were inadequate for generalising about the bioavailability of the PAHs in the sediments. The XAD-2 method extracted greater amounts of PAHs (3–34% of total-PAHs in sediments), however, the total-PAH concentrations in the sediments provided a better, or equally good, prediction of PAH bioaccumulation by T. deltoidalis. The results indicated that these methods required further development before they can be applied routinely as surrogate methods for assessing the bioavailability of PAHs in sediments. Future research should be directed towards lowering detection limits and obtaining comparative data for a greater range of sediment types, contaminant classes and concentrations, and organisms of different feeding guilds and with different gut chemistry.  相似文献   

3.
Fixed beds of sorbent media are used for the evaluation of poiynuclear aromatic hydrocarbons (PAH) present in air. Twostage sampling and separate extraction and analyses of PAH associated with aerosol particles and those present in the vapor state are usually performed. The ability of commonly used sorbents to retain particulate matter introduces a potential for reducing the time and cost of PAH evaluation procedures.

The filtration efficiency of three sorbent media, Florisil, XAD-2, and polyurethanefoam (PUF), for particles in 0.1 to 1 µm size range was studied using airflow rates from 4 to 2501 /mm through a PS 1 sorbent cartridge. Theoretical considerations were used to identify the principal filtration mechanisms and to assess the predictability of the aerosol filtration performance of sorbent filters. The results of this study indicate XAD-2 to be an efficient filtration medium owing to the electrostatic enhancement of capturing and retaining aerosol particles.

As a result of theoretical considerations, Brownian diffusion and inertial deposition were found to be major filtration mechanisms accompanied by electrostatic effects. While the efficiency of the diffusional deposition mechanism was reasonably well predicted with available theories, modeling of submicron particle impaction at higher fluid velocities appeared to be inadequate. Further developments are suggested to improve our understanding of filtration phenomena in sorbent beds under high flow rate conditions.  相似文献   

4.
Abstract

This paper summarizes the sampling and analytical methods developed to identify and measure polycyclic aromatic hydrocarbons (PAH) and related aromatic compounds near a Horizontal Stud Soderberg plant at Jonquiere, Quebec, Canada. The primary source of PAH is the coal tar pitch used as a binder in Soderberg anodes. Twice a week at a number of sampling sites, airborne particulate matter was collected on glass-fiber filters using a Hi-Vol sampler for a twenty-four hour period. Organics on the filter were Soxhlet extracted with benzene.

Identification was done by gas chromatography-mass spectrometry (GC-MS). The vast majority of compounds present were PAH, but small amounts of alkyl PAH and polycyclic aromatic compounds with heteroatoms such as nitrogen, oxygen and sulfur were also identified. Based on the GC-MS identification, a group of 14 PAH was selected for monitoring. Frequent PAH determinations revealed that the ratio of Benzo(a- )Pyrene to total PAH on the Hi-Vol filters is relatively constant in ambient air from one sampling station to another.  相似文献   

5.
Activated charcoal, Amberlite XAD-2, and Amberlite XAD-7 have been evaluated for the solid sampling of airborne nitroglycerin, ethylene glycol dinitrate and isopropyl nitrate. With the use of diethyl ether for solvent desorption, XAD-2 was found superior for sampling nitroglycerin and ethylene glycol dinitrate. Both XAD-7 and activated charcoal gave high recoveries for isopropyl nitrate; charcoal had a greater capacity than XAD-7 for this compound, however.  相似文献   

6.
An Automated Preconcentration Sampler (APS) was developed by the Ontario Ministry of the Environment (MOE) and Carleton University for the determination of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in drinking water. The APS employs a two-stage particulate filtration system followed by an XAD-2 resin column. Field and laboratory testing of the APS is required to validate the device before it is put into regular service.The capacity of the APS filtration system is 30 L for a 4 Formazin Turbidity Unit (FTU) input water turbidity and greater than 50 L for a typical treated water. Flushing of a clean XAD-2 resin column with 200 L of spiked water showed that the optimum flowrate in terms of spike breakthrough is equal to three times the resin bed volume per minute. This flowrate is used for APS operation. Testing also showed that no spike breakthrough occurred after 200 L of clean water was flushed through a spiked XAD-2 resin column at flowrates in excess of the APS operating flowrate. Spike testing was also carried out on the filters and results are pending. An analytical comparison between the present MOE sampling and analytical procedure and the proposed APS sampling and analytical procedure using a PCDD/PCDF source water is planned.  相似文献   

7.
Activated charcoal, Amberlite XAD-2 and Amberlite XAD-7 were evaluated for the adsorption of epichlorohydrin and ethylene chlorohydrin from air followed by desorption with solvent. Ethylene chlorohydrin was found to be unstable on activated charcoal in the presence of carbon disulfide. Recoveries from XAD-2 were low, and XAD-7 was found to be the best adsorbent for the sampling of these compounds from air.  相似文献   

8.
A personal air sampling method using Amberlite XAD-2 coated with 2,4-dinitrophenylhydrazine has been developed for acrolein and glutaral dehyde. Acrolein in the 0.01 to 1.2 mg/m3 range or glutaraldehyde in the 0.03 to 3.5 mg/m3 range is easily analysed in a 5 1 air sample. Recoveries are high (80–100%), and samples stable at least for two weeks if stored in the dark until analysed.  相似文献   

9.
Amberlite XAD-2 porous polymer was evaluated for the solid sampling of PCBs, PCNs, tri-, tetra-and pentachlorophenol in workroom air. Using solvent desorption, the recoveries of these compounds from XAD-2 was mostly about 80%, showing this adsorbent to be an excellent medium for the sampling of polychlorinated aromatics in air.  相似文献   

10.
The influence of air humidity on the sampling efficiency of Amberlite XAD porous polymers and activated charcoal was studied by determining the recovery of various organics at 20% and 85% relative humidity. The sampling efficiency of XAD-7 was found to decrease with increasing relative humidity, while the sampling efficiency of XAD-2 and activated charcoal was relatively unaffected for the compounds studied. Activated charcoal had a greater capacity than Amberlite XAD for several types of compounds, however.  相似文献   

11.
The concentrations of some polycyclic aromatic hydrocarbons (PAH) and oxygenated PAH (O-PAH) can be changed by oxidation reactions during sampling. This can lead to an over- or underestimation of the corresponding adverse health effects. The aim of this study was the evaluation of these sampling artefacts. The potential of using an oxidant denuder was shown by parallel low-volume sampling with and without MnO2 ozone denuder. Twenty-three PAH and 11 O-PAH in ambient air were analysed, both in the vapour and particulate phase. The denuder was proven to be highly efficient for stripping ozone from air while causing no significant particle losses. In general, the concentrations of 5- to 7-ring PAH, which are predominantly associated with particles, were underestimated in non-denuded samples. The highest losses due to reaction with ozone and other atmospheric oxidants were observed for benzo[a]pyrene and perylene. Concurrently, the concentrations of most of the mainly particle-associated 4- to 5-ring O-PAH were higher in the non-denuded samples. The denuder did not only remove ozone, moreover other gaseous species such as more volatile PAH and O-PAH were partially oxidized on the catalytic surface, too. Degradation of PAH and concurrent degradation/formation reactions of O-PAH occurred. The corresponding reactivities of selected PAH and O-PAH are discussed.  相似文献   

12.
PAH deposition to snow surface   总被引:2,自引:0,他引:2  
The urban snowpack effectively acts as a collection device for atmospheric-deposited PAHs. When these PAHs are flushed out in a short time interval along with springtime snowmelt, these cause shockloading to receiving waters. In order to assess the PAH deposition and accumulation in urban snowpacks, a deposition survey of PAH for the winter months of 1991-92 from the city of Sault Ste. Marie, Ontario, Canada was undertaken. The results of the survey are interpreted in view of prevailing meteorology and various emission sources in the study area. The relative PAH deposition levels (to BaP) are compared with relative source emission fingerprints to examine consistency in sampling and analysis. While analyzing the PAH samples using the ASTM (1987) method, the problem of concentration levels being below the detection level was encountered. The ASTM method for PAH analysis was modified to enhance the detection limit of the PAHs by concentrating the PAH extract to very low volumes, on the order of 200-300 microL.  相似文献   

13.
In this paper a new electronically controlled year-round wet-only sampler for wet deposition of trace organic compounds (e.g. airborne PAHs) is described. The sampler provides in situ filtration of the precipitation as well as preconcentration of nonpolar organic compounds by means of a C18-PAH modified silica gel cartridge. The whole assembly is insulated and equipped with heating elements which permit collection of wet deposition as ice or snow and insure correct function of the sampling system even during cold weather. Concurrent chemical analysis of both the particulate and the dissolved phases is performed by high resolution gas chromatography with flame ionization detection or HPLC with fluorescence detection. The reliability of the method was proved by analyzing PAH spiked water (simulated rain) and using NIST SRM 1649 ('urban dust') as certified material for particle-bound PAHs in precipitation. This study proved satisfactorily recoveries of as both particle-bound and unbound aqueous PAH, with only small losses to collector surfaces. It was proved that this new wet-only precipitation sampler can successfully be used for long-time monitoring of PAH in wet depositions in urban areas.  相似文献   

14.
The porous polymers Amberlite XAD-2 and XAD-7 were evaluated for the sampling of ethylene glycol, 2-methoxyethanol, 2-ethoxyethanol, 2-butoxyethanol and 2-ethoxyethyl acetate in work-room air. Using diethyl ether desorption, these adsorbents were found excellent for the compounds studied.  相似文献   

15.
Amberlite XAD-2 and XAD-7 porous polymers were evaluated for the solid sampling of aliphatic and aromatic nitro compounds in work-room air. With the use of solvent desorption, XAD-2 gave 80–100% recovery of nitroaromatics, and XAD-7 85–100% recovery of nitroaliphatics. The compounds studied were nitromethane, nitroethane, 2-nitropropane, nitrobenzene, m-dinitrobenzene and 2,4,6-trinitrotoluene. All six compounds gave very poor recoveries from activated charcoal.  相似文献   

16.
A sampling procedure for 2,4- and 2,6-toluenediisocyanate (TDI) and 4,4′-diphenylmethane diisocyanate (MDI) in the range 0.007-0.7 mg/m3 in a 15 L air sample is described. The sampling is performed with 9-(N-methylaminomethyl)-anthracene (MAMA) adsorbed on a solid sorbent, Amberlite XAD-2. The recoveries are 80–100% in this chemosorption reaction. The urea derivatives are desorbed with N,N-dimethylformamide and analysed by high performance liquid chromatography (HPLC). Samples and prepared chemosorption tubes are stable for at least two weeks if stored in the dark. To complete the investigation, field measurements of TDI were performed in an industrial atmosphere.  相似文献   

17.
There have been discussions about how complete PCDDs and PCDFs are sampled from stack gas of waste combustion plants by various sampling methods. In Germany, at present, a sampling method is used, which was first proposed by Nottrodt et al.1, consisting of a filter device, condenser, and an absorption train. Since this sampling procedure complicates sampling and analysis, we compared this “standard procedure” with a “dilution method”, where only a filter, impregnated with paraffin, is used as trapping device, and also tested the effectiveness of XAD-2 as an adsorption trap.

As standard procedure the standard train was always used in parallel to other sampling methods. The results of four parallel sampling periods confirmed, that comparable results are obtained, when parallel sampling is carried out with the standard train.

The result of our investigation can be summarized as follows: The total emission of PCDDs and PCDFs determined by different sampling procedures varies only insignificantly. This means that sampling and analysis for PCDDs and PCDFs in stack gas could be simplified considerably.  相似文献   


18.
A method for determining atmospheric concentrations of eight pesticides applied to corn and soybean crops in Mato Grosso state, Brazil is presented. The method involved a XAD-2 resin cartridge coupled to a low volume air pump at 2 L min?1 over 8 hours. Pesticides were recovered from the resin using sonication with n-hexane:ethyl acetate and determined by GC-MS. Good accuracy (76-128%) and precision (CV < 20%) were obtained for atrazine, chlorpyrifos, alpha- and beta-endosulfan, endosulfan sulfate, flutriafol, malathion, metolachlor and permethrin. Method detection ranged from 9.0 to 17.9 ng m?3. This method was applied to 61 gas phase samples collected between December 2008 and June 2009. Atrazine and endosulfan were detected both in urban and rural areas indicating the importance of atmospheric dispersion of pesticides in tropical areas. The simple and efficient extraction method and sampling system employed was considered suitable for identifying pesticides in areas of intense agricultural production.  相似文献   

19.
XAD-2 resin-based passive samplers (PAS) with dimensions adapted to 100 mL accelerated solvent extraction cells were used to study the temporal and spatial variations of 17 PAHs on five sites in the atmosphere of southern Luxembourg. This new design allowed extracting the PAS without emptying the resin from the shelter. PAH analyses were done with gas chromatography–tandem mass spectrometry. PAS were deployed for 1 year with varying sampling periodicities, and 16 PAHs were detected with concentrations ranging from 1 ng/PAS for chrysene to 9,727 ng/PAS for naphthalene. The PAS were found adapted to the monitoring of temporal and spatial variations for lightweight PAHs (up to four aromatic rings) though not for heavy PAHs with five aromatic rings or more, as these compounds are preferably in the particle phase of the atmosphere and the amount of these PAHs trapped on the PAS will be too low.  相似文献   

20.
Emissions from a cereal straw through-burning furnace have been characterized by chemical analysis and the Ames Salmonella/microsome assay. The emissions of polycyclic aromatic hydrocarbons (PAH) were considerable, from 24 to 64 mg per kilo dry fuel. Most of the mutagenic activity was found in the extracts of the particles, while the condensate fractions and the XAD-2 extracts showed much lower mutagenic responses.  相似文献   