首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Radon control systems were installed and evaluated in fourteen homes in the Spokane River Valley/Rathdrum Prairie and in one home in Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurization was always more effective in these houses than SSV by depressurization in reducing indoor radon levels to below guidelines. Basement overpressurization was successfully applied in five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace isolation in reducing radon entry from the crawlspace, but had to be used in conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations in two houses with air-to-air heat exchangers (AAHX) were reduced to levels inversely dependent on the new total ventilation rates and were lowered even further in one house where the air distribution system was modified. Sealing penetrations in the below-grade surfaces of substructures was relatively ineffective in controlling radon. Operation of the radon control systems (except for the AAHX's) made no measureable change in ventilation rates or indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX's. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.  相似文献   

2.
Radon control systems were Installed and evaluated In fourteen homes In the Spokane River Valley/Rathdrum Prairie and In one home In Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurlzatlon was always more effective In these houses than SSV by depressurlzatlon In reducing Indoor radon levels to below guidelines. Basement overpressurlzatlon was successfully applied In five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace Isolation in reducing radon entry from the crawlspace, but had to be used In conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations In two houses with alr-toalr heat exchangers (AAHX) were reduced to levels Inversely dependent on the new total ventilation rates and were lowered even further In one house where the air distribution system was modified. Sealing penetrations In the below-grade surfaces of substructures was relatively Ineffective In controlling radon. Operation of the radon control systems (except for the AAHX’s) made no measureable change in ventilation rates or Indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX’s. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.  相似文献   

3.
A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m-3 (4 pCi L-1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m-3) from the highly permeable soils (geometric mean permeability of 5 x 10(-11) m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h-1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.  相似文献   

4.
A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m?3 (4 pCi L?1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m?3) from the highly permeable soils (geometric mean permeability of 5 × 10?11 m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h?1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.  相似文献   

5.
Radon gas concentrations have been monitored as part of the operation of a tunnel (the Exploratory Studies Facility-ESF) at Yucca Mountain to ensure worker safety. The objective of this study was to examine the potential use of the radon data to estimate large-scale formation properties of fractured tuffs. This objective was examined by developing a numerical model, based upon the characteristics of the ESF and the Topopah Spring welded (TSw) tuff unit, capable of predicting radon concentrations for prescribed ventilation conditions. The model was used to address two specific issues. First, it was used to estimate the permeability and porosity of the fractures in the TSw at the length scale of the ESF and extending tens of meters into the TSw, which surrounds the ESF. Second, the model was used to understand the mechanism leading to radon concentrations exceeding a specified level within the ESF. The mechanism controlling radon concentrations in the ESF is a function of atmospheric barometric fluctuations being propagated down the ESF along with ventilated air flow and the slight suction induced by the ventilation exhaust fans at the South Portal of the ESF. These pressure fluctuations are dampened in the TSw fracture continuum according to its permeability and porosity. Consequently, as the barometric pressure in the ESF drops rapidly, formation gases from the TSw are pulled into the ESF, resulting in an increase in radon concentrations. Model calibration to both radon concentrations measured in the ESF and gas-phase pressure fluctuations in the TSw yielded concurrent estimates of TSw fracture permeability and porosity of 1 x 10(-11) m2 and 0.00034, respectively. The calibrated model was then used as a design tool to predict the effect of adjusting the current ventilation-system operation strategy for reducing the probability of radon gas concentrations exceeding a specified level.  相似文献   

6.
Though several different models have been developed for sub-surface migration, little attention has been given to the effect of subsurface transport on the indoor environment. Existing methods generally assume that a house is one well-mixed compartment. A two-compartment model was developed to better characterize this exposure pathway; the model treats the house as two well-mixed compartments, one for the basement and one for the remainder of the house. A field study was completed to quantify parameters associated with the two-compartment model, such as soil gas intrusion rates and basement to ground floor air exchange rates. Two residential test houses in Paulsboro, New Jersey were selected for this study. All experiments were completed using sulfur hexafluoride (SF6) as a tracer gas. Soil gas intrusion rates were found to be highly dependent on the soil gas to basement pressure difference, varying from 0.001 m3 m−2 h−1 for a pressure drop of –0.2 Pa to 0.011 m3 m−2 h−1 for a pressure drop of –6.0 Pa. Basement ventilation rates ranged from 0.17 to 0.75 air changes per hour (ACH) for basement to ambient pressure differences ranging from –1.1 to –7.6 Pa (relative to ambient). Application of experimental results in conjunction with the two-compartment model indicate that exposures are highly dependent on gas intrusion rates, basement ventilation rate, and fraction of time spent in the basement. These results can also be significantly different when compared with the simple well-mixed house assumption.  相似文献   

7.
We analyzed more than 70,000 air leakage measurements in houses across the United States to relate leakage area—the effective size of all penetrations of the building shell—to readily available building characteristics such as building size, year built, geographic region, and various construction characteristics. After adjusting for the lack of statistical representativeness of the data, we found that the distribution of leakage area normalized by floor area is approximately lognormal. Based on a classification tree analysis, year built and floor area are the two most significant predictors of leakage area: older and smaller houses tend to have higher normalized leakage areas than newer and larger ones. Multivariate regressions of normalized leakage are presented with respect to these two factors for three house classifications: low-income households, energy program houses, and conventional houses. We demonstrate a method of applying the regression model to housing characteristics from the American Housing Survey to derive a leakage-area distribution for all single-family houses in the US. The air exchange rates implied by these estimates agree reasonably well with published measurements.  相似文献   

8.
Fourteen single-family detached houses in Spokane, Washington, and Coeur D'Alene, Idaho, were monitored for two years after high concentrations of indoor radon had been mitigated. Each house was monitored quarterly using mailed alpha-track radon detectors deployed in each zone of the structure. To assess performance of mitigation systems during the second heating season after mitigation, radon concentrations in seven houses were monitored continuously for several weeks, mitigation systems in all houses were inspected, and selected other measurements were taken. In addition, occupants were also interviewed regarding their maintenance, operation, and subjective evaluation of the radon mitigation systems. Quarterly alpha-track measurements showed that radon levels had increased in most of the homes during many follow-up measurement periods when compared with concentrations measured immediately after mitigation. Mitigation-system performance was adversely affected by (1) accumulated outdoor debris blocking the outlets of subsurface pressurization pipes; (2) fans being turned off (e.g., because of excessive noise or vibration); (3) air-to-air heat exchanger, basement pressurization, and subsurface ventilation fans being turned off and fan speeds reduced; and (4) crawl-space vents being closed or sealed.  相似文献   

9.
Fourteen single-family detached houses In Spokane, Washington, and Coeur D’Alene, Idaho, were monitored for two years after high concentrations of indoor radon had been mitigated. Each house was monitored quarterly using mailed alpha-track radon detectors deployed in each zone of the structure. To assess performance of mitigation systems during the second heating season after mitigation, radon concentrations in seven houses were monitored continuously for several weeks, mitigation systems In all houses were inspected, and selected other measurements were taken. In addition, occupants were also interviewed regarding their maintenance, operation, and subjective evaluation of the radon mitigation systems. Quarterly alpha-track measurements showed that radon levels had increased In most of the homes during many follow-up measurement periods when compared with concentrations measured immediately after mitigation. Mitigation-system performance was adversely affected by (1) accumulated outdoor debris blocking the outlets of subsurface pressurization pipes; (2) fans being turned off (e.g., because of excessive noise or vibration); (3) air-to-air heat exchanger, basement pressurization, and subsurface ventilation fans being turned off and fan speeds reduced; and (4) crawlspace vents being closed or sealed.  相似文献   

10.
Movement of radon progeny inside houses is a complex process that depends both on atmospheric conditions and on building structure. The indoor working level (WL) monitored in four houses of differing structures shows regular diurnal fluctuations related to solar warming of the atmosphere. In the two houses with full basements, radon is removed by indoor/outdoor pressure-driven airflow, and basement WL varies inversely with outdoor temperature. In the two houses with half basements open to crawl spaces, radon is drawn into the basement faster than it is removed, so that basement WL varies directly with outside temperature. Average WL's in basements are about twice as high as first floor WL's and as much as 18 times as high as outdoor WL's. Each house shows an individual pattern of radon progeny movement throughout the building.  相似文献   

11.
Soil radon was measured from late October 2000 to January 2001 at three test sites on the campus of Hokkaido University in Sapporo, Japan. Factors affecting radon concentrations were investigated with relation to meteorological data, as well as soil 226Ra content, mineral composition, water content, and pH, Eh and conductivity. Soil radon varied with time and with sampling site appreciably, in a manner unaltered by the surface geology. However, the ratio of radon isotopes (220Rn/222Rn) in the soil was constant within each sampling site, regardless of varying concentration of these nuclides during the monitoring period. Snow covering on the soil surfaces may affect the 222Rn concentration.  相似文献   

12.
高原地区铬渣污染场地污染特性研究   总被引:12,自引:1,他引:11  
在我国高原地区某铬渣污染场地进行钻孔取样,分析场地工程地质特性,对场地铬的污染状况及空间分布特征进行研究。结果表明:场地地质结构较单一,地下水丰富,土质的渗透性强,渗透系数在1.78×10-3~0.243 cm/s之间;场地铬污染严重,总铬与六价铬的浓度最大值分别为22 485.6 mg/kg和7 495.2 mg/kg,地下水中六价铬的浓度最大值为107.2 mg/L;通过剖面铬浓度分析:铬在纵向上浓度分布受土壤质地的影响,均呈现表层4 m浓度较高,4 m以下浓度较低且变化较小的规律。由Kriging插值法绘的铬浓度分布等值线图可清晰看出场地表层土表现出向沟谷位置迁移趋势,地下水中残留的铬向地下水流场方向迁移。  相似文献   

13.
Yu D  Kim JK 《Chemosphere》2004,54(5):639-645
Most of the indoor radon comes directly from the soil beneath the foundation of a basement. Recently, radon from groundwater was found to make some contribution to the total inhalation risk associated with radon in indoor air. This study presents a realistic exposure assessment of a human to indoor radon released from groundwater. First, the prediction of indoor radon concentration released from groundwater was based on a three-compartment model that was developed to describe the transfer and distribution of the radon released from groundwater in a house through showers, washing clothes, and flushing toilets. Second, a physiologically based pharmacokinetic (PBPK) model for inhaled radon was developed and used to estimate tissue group concentrations in a human body. The PBPK model provides reasonable predictions of uptake, excretion, and distribution of retained radon among tissue groups in the body. Hence, the approach using the PBPK model combined with realistic indoor exposure scenarios predicts the radon concentrations in tissue groups in the body associated with the indoor radon pollution. The results obtained from the study will help increase the quantitative understanding of the risk assessment issues associated with the indoor radon released from the groundwater.  相似文献   

14.
The concentrations of indoor radon in the basements of homes located in southern Maryland average about 1.3 times the first floor radon concentrations. Particular geological units tend to be associated with higher indoor radon. In the study area, homes underlain by phyllite were mostly above 4 pCi/liter (the US Environmental Protection Agency 'action level'). Comparative studies between indoor radon and total-gamma aeroradioactivity show that aeroradioactivity can be accurately used to estimate community radon hazards. When combined, geology and aero radioactivity can be used to identify problem homes.  相似文献   

15.
Analysis of time-series data sets, collected in vernacular buildings and workplaces linked with radium source bedrock has identified a number of internal and external pressure characteristics linking meteorological parameters with the variability of radon gas and its progeny. The cellars in these buildings are excavated from the bedrock associated with the radium source and have relatively high levels of radon concentration along with largely stable microclimatic conditions, which differ from those of the buildings’ ground and upper levels. In workplace environments cyclical characteristics are apparent, associated with heating and ventilation related to working hours. Comparative radon concentration data, collected within buildings and similarities identified between buildings, suggest the need to distinguish between short and longer-term influences. From a range of comparative data studied, water vapour pressure, a partial pressure of barometric pressure, is indicated as a principal determinant of the short-term variability of radon gas concentrations, with barometric pressure determining the trend or general longer term level, both linked to temperature. Wind speed appears to have the potential for a dual influence on radon variability: directly, through wind pressure differences and indirectly, through changes to the water vapour component.  相似文献   

16.
Although many remedial measures have been proposed for excessive Indoor 222Rn concentrations, their general effectiveness in given situations is not well established, In part because of the number and complexity of the factors that influence Indoor 222Rn. The strategy considered here is the use of basement ventilation to control upstairs Indoor radioactivity. A simple two-compartment model is described and used to derive ventilation rates that are needed to lower radon concentrations to specified levels. Previously published indoor radon measurements are used to derive the parameters needed for the calculations. The results of the two compartment model differ typically by a factor of two from the simpler, more often used one-compartment approximation.  相似文献   

17.
In order to predict indoor radiation levels due to radon daughters at low building ventilation and air leakage rates, differential equations governing the decay and venting of radon (Rn-222) and its daughters were used. A computer program based on the equations was written to predict radon and daughter concentrations, total potential alpha energy concentration and equilibrium factor. The program can account for time dependence of ventilation and emanation rates and is readily used by building designers.

Sample calculations using the program showed that potential alpha energy levels in tightened buildings can commonly reach about 0.01 working level (WL), a level more than twice as high as concentrations currently found in most houses.  相似文献   

18.
Pitch canker disease (Fusarium circinatum Nirenberg & O'Donnell) causes serious shoot dieback, reduced growth and mortality in pines found in the southern and western USA, and has been linked to nutrient imbalances. Poultry houses with forced-air ventilation systems produce nitrogen (N) emissions. This study analyzed spatial correlations between pitch canker disease and foliar, forest floor, soil, and throughfall N in a slash pine (Pinus elliottii var. elliottii Engelm.) plantation adjacent to a poultry operation in north Florida, USA. Tissue and throughfall N concentrations were highest near the poultry houses and remained elevated for 400 m. Disease incidence ranged from 57-71% near the poultry houses and was spatially correlated with N levels. Similarly, stem mortality ranged from 41-53% in the most heavily impacted area, and declined to 0-9% at distances greater than 400 m. These results suggest that nutritional processes exacerbate changes in disease susceptibility and expression in slash pine.  相似文献   

19.
Approximately 80,000 kg polysulfide sealant containing 10,000-18,000 kg polychlorinated biphenyls (PCB) was deposited at a Swedish municipal landfill station during 1965-1973. Investigations during 1994 showed that soil layers underneath the landfill had concentration of PCB not alarmingly high. The concentration of PCB congeners in ground water samples was elevated 4-750 times compared to a reference sample. Based on samples of ground water, leachate water, and flux chambers measuring evaporation of PCB from the landfill surface, the emission of PCB was estimated to be 1 g sigmaPCB/yr. This very low rate was attributed to the high sorptive capacity of the sealant. Compared to a reference site, the evaporation flux was elevated for the most volatile congeners, but factors 20-1400 lower than from another landfill which was contaminated with PCB in paper-pulp fibres.  相似文献   

20.
Throughout several coastal regions in the Mediterranean where rainfalls rarely exceed 650 mm per year municipal treated wastewater can be conveniently reused for soil irrigation. Where the coastal aquifer supplies large populations with freshwater in such area, an assessment of ground water quality around spreading sites is needed. In this study, the efficacy of natural filtration on nitrogen degradation in wastewater spreads on the soil covering the Salento (Southern Italy) fractured limestone was quantified by using laboratory tests and field measurements. In the laboratory, effluent from municipal wastewater treatment plants was filtered through a package of fractures made by several slabs of limestone. An analysis of wastewater constituent concentrations over time allowed the decay rates and constants for nitrogen transformation during natural filtration to be estimated in both aerated and non-aerated (i.e., saturated) soil fractures. A simulation code, based on biodegradation decay constants defined in the laboratory experiments, was then used to quantify the total inorganic nitrogen removal from wastewater injected in an aquifer in the Salento region (Nardò). Here the water sampled in two monitoring wells at 320 m and 500 m from the wastewater injection site and downgradient with respect to groundwater flow was used to verify the laboratory nitrification and denitrification rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号