首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effects of carbonate on uranium (VI) solubility under aerobic and cementitious conditions have been investigated. The information is of relevance to low level nuclear waste disposal. Aqueous NaOH, KOH, Ca(OH)2 and a cement leachate solution were added to uranyl nitrate solution. Afterwards, increasing amounts of ammonium carbonate were added to re-dissolve the precipitates. The precipitates were characterised by means of X-ray powder diffraction (XRPD) measurements and modelling studies. The model calculations were performed using the MINTEQA2 speciation code, with an expanded database incorporating uranium stability constants taken from the HATCHES database. The measured and predicted amounts of CO3(2-) needed to dissolve the precipitates were compared. The knowledge gained from the 'pure' systems was used to rationalise the precipitation and re-dissolution behaviour observed in the leachate system. The lack of uranium solubility at low carbonate levels brought into question literature formation constants for UO2(OH)3- and UO2(OH)4(2-). An approximate log K value of 26.8 for K2U2O7 formation was estimated from the KOH results at pH 12. Generally, uranium solubilities are expected to be insignificant at low level nuclear waste sites because anaerobic conditions should persist. However, this study has demonstrated that solubility in leachate could rise at high pH and high carbonate levels, if aerobic conditions were to develop. Soluble U(VI) species would be formed. The novel part of the study has been to reproduce the effects and to correlate enhanced solubilities with model predictions. Consequently, the study has re-emphasised the need for appropriate environmental monitoring of such sites.  相似文献   

2.
To investigate the environmental safety of waste disposal landfill sites and of land reclaimed from such sites, we evaluated the toxicity of leachate from these sites by a combination of bioassays in the Japanese killifish medaka Oryzias latipes. We tested for lethal toxicity in adult and larval medaka and for hatching inhibition of embryos from eggs. As biochemical evidence of the effects of leachate exposure, CYP1A (EROD activity) and vitellogenin (Vtg) were induced. We also bioassayed water-treated leachate and downstream river water. Leachate solution was lethal to larval and adult medaka. Embryo hatchability was inhibited, and abnormal hatching, spinal deformity and anisophthalmia occurred in embryos exposed to leachate solution. CYP1A was induced by exposure to leachate solution diluted to 1.0%, and EROD activity was significantly higher than in control. Vtg and unknown proteins were induced in the sera of male medaka exposed to the diluted leachate solution. Conventional water treatments worked effectively to remove toxic compounds but did not work well to remove element ions, including heavy metals. Treated leachate produced neither lethal toxicity nor hatching abnormalities during the exposure period. Fish toxicity tests for leachate would be useful for monitoring the environmental safety of landfill sites.  相似文献   

3.
The impact of Attenda abattoir, Ogbomoso southwestern Nigeria on four water sources was investigated using geoelectrical imaging and microbiological analysis. 2D electrical resistivity imaging indicated groundwater contamination by leachate from the abattoir. Electrical resistivity values measured by the traverse run directly on the waste dump and other areas impacted by the waste from the abattoir are generally very low (6.68-16.7 ?m) in comparison to other positions (135-288 ?m). The total viable bacteria count of the water samples ranged from 0.49 × 10(6) to 2.85 × 10(8) cfu/ml and all samples are contaminated with coliforms with the most probable number (MPN)/100 ml ranging from 110 to ≥ 1,600 MPN/100 ml. Among bacteria isolated from the study site (n = 95), resistance to eight antibiotics ranged from 35.8% to 94%. In addition, 85% of Streptococcus agalactiae (n = 31) and Staphylococci (n = 9) showed haemolytic activity while 92% of all isolates showed β-lactamase activity. These results suggest that operations of the abattoir may impact negatively on surrounding aquatic ecosystem and endanger the health of surrounding residents who use water from the wells for domestic purposes. Furthermore, such aquatic ecosystems may serve as reservoir of antibiotic resistant bacteria.  相似文献   

4.
Industrial waste is one of the main causes of environmental pollution. Laser-induced breakdown spectroscopy (LIBS) was applied to detect the toxic metals in the sludge of industrial waste water. Sludge on filter paper was obtained after filtering the collected waste water samples from different sections of a water treatment plant situated in an industrial area of Kanpur City. The LIBS spectra of the sludge samples were recorded in the spectral range of 200 to 500 nm by focusing the laser light on sludge. Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) technique was used for the quantitative measurement of toxic elements such as Cr and Pb present in the sample. We also used the traditional calibration curve approach to quantify these elements. The results obtained from CF-LIBS are in good agreement with the results from the calibration curve approach. Thus, our results demonstrate that CF-LIBS is an appropriate technique for quantitative analysis where reference/standard samples are not available to make the calibration curve. The results of the present experiment are alarming to the people living nearby areas of industrial activities, as the concentrations of toxic elements are quite high compared to the admissible limits of these substances.  相似文献   

5.
The market place is considered to be an important centre of daily life of campus community. In India, as in Europe and the USA, other forms of shopping have emerged significantly and now predominate, for instance department stores and supermarkets. Though, it is suffered from poor waste management, but the place could be a potential source for obtaining non-conventional energy. The present study examined the quality of market waste management of the Indian Institute of Technology Campus along with the feasibility of biogas production from leachate generated in the waste. Solid wastes from different storage locations of the market place were collected and analyzed. The characteristics of solid wastes were found to be degradable in nature. The wastes, composed of 85% of vegetable origin, were placed in a container and water was added to to generate leachate. The self-purification efficiency of leachate was also studied in the Indian environment and compared with research findings in the USA under an identical moisture application rate. Leachate characterization was investigated both under saturated and submerged conditions. The treatability of leachate was studied in a laboratory-scale up-flow anaerobic filter with hollow burnt clay rings as packing media. It was observed that 4,000–6,000 mg/l would be the optimum range of inlet chemical oxygen demand (COD) concentration for leachate treatment because of the inhibitory effect of ammonia, sulphide, volatile fatty acids and toxic metals in high concentrations at higher strengths of leachate. The gas production rate was found to be at a maximum at 38°C and containing 70–75% methane. From experimental data, it was revealed that 83% COD was removed with input COD concentration of 5,475 mg/l at 2 days hydraulic retention time with biogas yield coefficients of 0.61. The present study also investigated the removal efficiency of chloride, ammonia, sulphide and nitrate.  相似文献   

6.
Christi Bay is a relatively flat, shallow, wind-driven system with an average depth of 3–4 m and a mean tidal range of 0.3 m. It is completely mixed most of the time, and as a result, depth-averaged models have, historically, been applied for hydrodynamic characterization supporting regulatory decisions on Texas coastal management. The bay is highly stratified during transitory periods of the summer with low wind conditions. This has important implications on sediment transport, nutrient cycling, and water quality-related issues, including hypoxia which is a key water quality concern for the bay. Detailed hydrodynamic characterization of the bay during the summer months included analysis of simulation results of 2-D hydrodynamic model and high-frequency (HF) in situ observations. The HF radar system resolved surface currents, whereas an acoustic Doppler current profiler (ADCP) measured current at different depths of the water column. The developed model successfully captured water surface elevation variation at the mouth of the bay (i.e., onshore boundary of the Gulf of Mexico) and at times within the bay. However, large discrepancies exist between model-computed depth-averaged water currents and observed surface currents. These discrepancies suggested the presence of a vertical gradient in the current structure which was further substantiated by the observed bi-directional current movement within the water column. In addition, observed vertical density gradients proved that the water column was stratified. Under this condition, the bottom layer became hypoxic due to inadequate mixing with the aerated surface water. Understanding the disparities between observations and model predictions provides critical insights about hydrodynamics and physical processes controlling water quality.  相似文献   

7.
Direct current (DC) resistivity, self potential (SP) and very low frequency electromagnetic (VLF-EM) measurements are carried out to detect the spread of groundwater contamination and to locate possible pathways of leachate plumes, that resulted from an open waste disposal site of Canakkale municipality. There is no proper management of the waste disposal site in which industrial and domestic wastes were improperly dumped. Furthermore, because of the dumpsite is being located at the catchment area borders of a small creek and is being topographically at a high elevation relative to the urban area, the groundwater is expected to be hazardously contaminated. Interpretations of DC resistivity geoelectrical data showed a low resistivity zone (<5 ohm-m), which appears to be a zone, that is fully saturated with leachate from an open dumpsite. The VLF-EM and SP method, support the results of geoelectrical method relating a contaminated zone in the survey area. There is a good correlation between the geophysical investigations and the results of previously collected geochemical and hydrochemical measurements.  相似文献   

8.
This paper investigates the organic pollution status of shallow aquifer sediments and groundwater around Zhoukou landfill. Chlorinated aliphatic hydrocarbons, monocylic aromatic hydrocarbons, halogenated aromatic hydrocarbons, organochlorine pesticides and other pesticides, and polycyclic aromatic hydrocarbons (PAHs) have been detected in some water samples. Among the detected eleven PAHs, phenanthrene, fluorine, and fluoranthene are the three dominant in most of the groundwater samples. Analysis of groundwater samples around the landfill revealed concentrations of PAHs ranging from not detected to 2.19 μg/L. The results show that sediments below the waste dump were low in pollution, and the shallow aquifer, at a depth of 18–30 m, was heavily contaminated, particularly during the wet season. An oval-shaped pollution halo has formed, spanning 3 km from west to east and 2 km from south to north, and mainly occurs in groundwater depths of 2–4 m. For PAH source identification, both diagnostic ratios of selected PAHs and principal component analysis were studied, suggesting mixed sources of pyro- and petrogenic derived PAHs in the Zhoukou landfill. Groundwater table fluctuations play an important role in the distribution of organic pollutants within the shallow aquifer. A conceptual model of leachate migration in the Quaternary aquifers surrounding the Zhoukou landfill has been developed to describe the contamination processes based on the major contaminant (PAHs). The groundwater zone contaminated by leachate has been identified surrounding the landfill.  相似文献   

9.
In semi-arid areas like the Kairouan region, salinization has become an increasing concern because of the constant irrigation with saline water and over use of groundwater resources, soils, and aquifers. In this study, a methodology has been developed to evaluate groundwater contamination risk based on the unsaturated zone hydraulic properties. Two soil profiles with different ranges of salinity, one located in the north of the plain and another one in the south of plain (each 30 m deep) and both characterized by direct recharge of the aquifer, were chosen. Simulations were conducted with Hydrus-1D code using measured precipitation data for the period 1998–2003 and calculated evapotranspiration for both chosen profiles. Four combinations of initial conditions of water content and salt concentration were used for the simulation process in order to find the best match between simulated and measured values. The success of the calibration of Hydrus-1D allowed the investigation of some scenarios in order to assess the contamination risk under different natural conditions. The aquifer risk contamination is related to the natural conditions where it increased while facing climate change and temperature increase and decreased in the presence of a clay layer. Hydrus-1D was a useful tool to predict the groundwater level and quality in the case of a direct recharge and in the absence of any information related to the soil layers except for the texture.  相似文献   

10.
Medina playa lake, a Ramsar site in western Andalusia, is a brackish lowland lake of 120 ha with an average depth of 1 m. Water flows into Medina from its 1,748-ha watershed, but the hydrology of the lake has not previously been studied. This paper describes the application of a water budget model on a monthly scale over a 6-year period, based on a conceptual hydrological model, and considers different future scenarios after calibration to improve the understanding of the lake’s hydrological functioning. Climatic variables from a nearby weather station and observational data (water-level evolution) were used to develop the model. Comparison of measured and predicted values demonstrated that each model component provided a reasonable output with a realistic interaction among the components. The model was then used to explore the potential consequences of land-use changes. Irrigation of olive groves would significantly reduce both the hydroperiod (becoming dry 15% of the time) and the average depth of the lake (water level <0.5 m 40% of the time). On the other hand, removal of an artificial overflow would double the average flooded surface area during high-water periods. The simulated water balance demonstrates that the catchment outputs are dominated by lake evaporation and surface outflow from the lake system to a creek. Discrepancies between predicted and observed water levels identify key areas of uncertainty for future empirical research. The study provides an improved basis for future hydrological management of the catchment and demonstrates the wider utility of this methodology in simulating this kind of system. This methodology provides a realistic appraisal of potential land-use management practices on a catchment-wide scale and allows predictions of the consequences of climate change.  相似文献   

11.
There is an increasing need to monitor concentrations of polar organic contaminants in the aquatic environment. Integrative passive samplers can be used to assess time weighted average aqueous concentrations, provided calibration data are available and sampling rates are known. The sampling rate depends on environmental factors, such as temperature and water flow rate. Here we introduce an apparatus to investigate the sampling properties of passive samplers using river-like flow conditions and ambient environmental matrices: river water and treated sewage effluent. As a model sampler we selected Empore SDB-RPS disks in a Chemcatcher housing. The disks were exposed for 1 to 8 days at flow rates between 0.03 and 0.4 m s(-1). Samples were analysed using a bioassay for estrogenic activity and by LC-MS-MS target analysis of the pharmaceuticals sulfamethoxazole, carbamazepine and clarithromycin. In order to assess sampling rates of SDB disks, we also measured aqueous concentrations of the pharmaceuticals. Sampling rates increased with increasing flow rate and this relationship was not affected by the environmental matrix. However, SDB disks were only sampling in the integrative mode at low flow rates <0.1 m s(-1) and/or for short sampling times. The duration of linear uptake was particularly short for sulfamethoxazole (1 day) and longer for clarithromycin (5 days). At 0.03 m s(-1) and 12-14 degrees C, the sampling rate of SDB disks was 0.09 L day(-1) for clarithromycin, 0.14 L day(-1) for sulfamethoxazole and 0.25 L day(-1) for carbamazepine. The results show that under controlled conditions, SDB disks can be effectively used as passive sampling devices.  相似文献   

12.
Performance of bioreactor landfill with waste mined from a dumpsite   总被引:1,自引:0,他引:1  
Emissions from landfills via leachate and gas are influenced by state and stability of the organic matter in the solid waste and the environmental conditions within the landfill. This paper describes a modified, ecologically sound waste treatment technique, where municipal solid waste is anaerobically treated in a lysimeter-scale landfill bioreactor with leachate recirculation to enhance organic degradation. The results demonstrate a substantial decrease in organic matter (BOD 99%, COD 88% and TOC 81%) and a clear decrease in nutrient concentrations especially ammonia (85%) over a period of 1 year with leachate recirculation.  相似文献   

13.
The present study deals with the ground water quality assessment in Kahuta Industrial Triangle Islamabad, Pakistan. The objective of the study was to assess ground water quality against the drinking water standards for various toxic inorganic elements. Representative groundwater samples were collected and analyzed in the Water Quality Laboratory of Pakistan Council of Research in Water Resources (PCRWR) at Islamabad, Pakistan. The samples were run on ICP-MS (Inductively coupled plasma mass spectrometry), which has the capability to separate and quantify 70 elements at a time. One of the finding of study is that ICP-MS is a very good tool to analyze broad range of toxic inorganic elements to the level of parts per billion (ppb). World Health Organization drinking water standards shows that these toxic inorganic elements such as heavy metals even at this concentration level (ppb) are injurious to human health. This analysis indicated pollution of various toxic elements including Selenium. Vertical leachate through industrial waste septic tanks is identified as major cause of groundwater pollution in the Industrial Triangle. Monitoring of the septic tanks and groundwater quality in study area is suggested along with remedial measures.  相似文献   

14.
尾矿库渗滤液中污染物会对区域地下水产生不利影响。根据拟建工程场地水文地质条件和气象资料,建立三维数值预测模型并分析非正常工况下两种典型污染情景对地下水环境的影响,预测结果显示:特征污染物As的质量浓度随时间推移逐渐变大;防渗层破损和无防渗情况下污染晕沿地下水流方向最远运移距离在第100 d、1 000 d、7 884 d时分别为72 m、225 m、262 m和78 m、335 m、391 m。由于下游河流及周边泉点为区内地下水排泄主要途径,污染物经排泄进入下游河流将对环境造成较大影响,故提出相应防范措施。  相似文献   

15.
多源环境监测信息交换模型的设计与实现   总被引:1,自引:0,他引:1  
针对环境监测系统现有的污染源管理、饮用水管理、噪声管理、自动监测管理等信息系统存在异构化、多源化等现象,造成数据重复录入、数据不一致、资源浪费等问题,展示了一种数据交换模型的设计思路和实现方法,介绍模型的数据抽取、数据封装、数据传递、数据解析、数据映射、校验和转换、数据接收等多个环节。该数据交换模型已成功实现与多个外部业务系统数据对接,现每天采集的数据超过5 000条,系统运行稳定、性能良好。  相似文献   

16.
Comparative leaching experiments were carried out using leaching medium with different pH to municipal solid waste in the landfill columns in order to investigate the mobility of heavy metals. The leachate pH and oxidation–reduction potential were measured by oxidation–reduction potential analyzer; the contents of heavy metals were measured by inductively coupled plasma mass spectrometry. It is very different in leaching concentrations of heavy metals; the dynamic leaching of heavy metals decreased with the rise of the leaching amount on the whole. Acid leaching medium had definite influence on the leaching of heavy metals in the early landfill, but it had the obvious inhibition effect on the leaching in the middle and late period of landfill; the neutral and alkaline leaching medium are more beneficial to the leaching of heavy metals. Due to the influence of the environment of landfill, the differences of the results in cumulative leaching amount, leaching rate, and leaching intensity of heavy metals are very big. The calculation results of the release rates of heavy metals prove that the orders of the release rates are not identical under different leaching conditions. Acid rain made heavy metals migrate from municipal solid waste to soil and detain in soil more easily; approached neutral and alkaline leaching mediums are more beneficial to leaching of heavy metals in the municipal solid waste and soil with leachate. The field verification of experimental data showed that the law of heavy metal leaching in municipal solid waste revealed by the experiment has a good consistency with the data obtained by municipal solid waste landfill.  相似文献   

17.
Dumping of solid waste in a non-engineered landfill site often leads to contamination of ground water due to leachate percolation into ground water. The present paper assesses the pollution potential of leachate generated from three non-engineered landfill sites located in the Tricity region (one each in cities of Chandigarh, Mohali and Panchkula) of Northern India and its possible effects of contamination of groundwater. Analysis of physico-chemical properties of leachate from all the three landfill sites and the surrounding groundwater samples from five different downwind distances from each of the landfill sites were collected and tested to determine the leachate pollution index (LPI) and the water quality index (WQI). The Leachate Pollution Index values of 26.1, 27 and 27.8 respectively for landfill sites of Chandigarh (CHD), Mohali (MOH) and Panchkula (PKL) cities showed that the leachate generated are contaminated. The average pH values of the leachate samples over the sampling period (9.2 for CHD, 8.97 for MOH and 8.9 for PKL) show an alkaline nature indicating that all the three landfill sites could be classified as mature to old stage. The WQI calculated over the different downwind distances from the contamination sites showed that the quality of the groundwater improved with an increase in the downwind distance. Principal component analysis (PCA) carried out established major components mainly from natural and anthropogenic sources with cumulative variance of 88% for Chandigarh, 87.1% for Mohali and 87.8% for Panchkula. Hierarchical cluster analysis (HCA) identifies three distinct cluster types for the groundwater samples. These clusters corresponds to a relatively low pollution, moderate pollution and high pollution regions. It is suggested that all the three non-engineered landfill sites be converted to engineered landfill sites to prevent groundwater contamination and also new sites be considered for construction of these engineered landfill sites as the present dumpsites are nearing the end of their lifespan capacity.  相似文献   

18.
In present study focus has been given on estimating quality and toxicity of waste with respect to heavy metals and its impact on groundwater quality, using statistical and empirical relationships between different hydrochemical data, so that easy monitoring may be possible which in turn help the sustainable management of landfill site and municipal solid waste. Samples of solid waste, leachate and groundwater were analyzed to evaluate the impact of leachates on groundwater through the comparison of their hydrochemical nature. Results suggest the existence of an empirical relationship between some specific indicator parameters like heavy metals of all three above mentioned sample type. Further, K/Mg ratio also indicates three groundwater samples heavily impacted from leachate contamination. A good number of samples are also showing higher values for and Pb than that of World Health Organization (WHO) drinking water regulation. Predominance of Fe and Zn in both groundwater and solid waste samples may be due to metal plating industries in the area. Factor analysis is used as a tool to explain observed relation between numerous variables in term of simpler relation, which may help to deduce the strength of relation. Positive loading of most of the factors for heavy metal clearly shows landfill impact on ground water quality especially along the hydraulic gradient. Cluster analysis, further substantiates the impact of landfill. Two major groups of samples obtained from cluster analysis suggest that one group comprises samples that are severely under the influence of landfill and contaminated leachates along the groundwater flow direction while other assorted with samples without having such influence.  相似文献   

19.
Artemia salina has, for the first time, been used as test organism for acute toxicity of leachate water from three landfills (the municipal landfills at Kristianstad, Sweden and Siauliai, Lithuania, and an industrial landfill at Stena fragmenting AB, Halmstad, as well as for leachate from Kristianstad treated in different ways in a pilot plan). Artemia can tolerate the high concentrations of chloride ions found in such waters. Large differences in toxicities were found, the leachate from Siauliai being the most toxic one. To increase the selectivity in the measurements, a fractionation was done by using ion exchange to separate ammonium/ammonia and metal ions from the leachate, and activated carbon adsorbents for organic pollutants. The influence of some metals and phenol compounds on the toxicity was investigated separately. It was found that most of the toxicity emanated from the ammonium/ammonia components in the leachate. However, there was also a significant contribution from organic pollutants, other than phenol compounds, since separate experiments had in this latter case indicated negligible impact. The concentrations of metals were at a level, shown by separate experiments, where only small contribution to the toxicity could be expected.  相似文献   

20.
Monitoring data collected from the Mingder Reservoir in Taiwan indicate that the water quality is between mesotrophic and eutrophic. Chlorophyll a concentration is higher in the summer and anoxic conditions occur in the bottom. The data also reveal that a pronounced vertical thermal gradient in summer and vertical mixing the end of fall. A vertical two-dimensional, laterally averaged hydrodynamic and water quality model (CE-QUAL-W2) was adopted to simulate the water surface elevation, water temperature, and water quality conditions in the water column. The modeling effort was supported with monitoring data collected in the field for a 2-year period in the reservoir. The hydrodynamic model reproduced the time series water surface elevation. Spatial and temporal distributions of temperature in the water column of the reservoir were also well reproduced by the hydrodynamic model. Model-calculated concentrations of key water quality constituents such as nutrients, dissolved oxygen, and algal biomass matched the measured values closely in the reservoir. The calibrated model was then applied to simulate water quality response to various nutrient reduction scenarios. Results of the model scenario runs reveal that a 20% and 80% reduction of the phosphorus loads will improve the water quality from eutrophic to mesotrophic and oligotrophic conditions, respectively. The modeling effort has yielded valuable information that can be used by decision makers for the evaluation of different management strategies of reducing watershed nutrient loads.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号