首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A grading system was developed to rate the moisture damage profile of dwellings and to study the relationship between moisture-induced indoor air problems and occupant health. A total of 630 randomly selected houses and apartments, built between 1950 and 1989, were visually inspected. Moisture observations were standardized into three damage levels. Thus, a system to classify the homes into three grades was devised. The two grades of homes associated with the highest levels of damage were graded as index homes. Overall, 51% of the sample had some kind of moisture fault in them and one in every three homes (33%) was classified as an index home. The mean number of damage incidents in the index dwellings varied from 1.4 to 2.6. The mean number of damage incidents in the reference homes was 0.28. Prevalence of index dwellings was significantly higher (p < 0.01) in houses (38%) than in apartments (26%). There was no major difference in the prevalence of index buildings in houses built in any particular decade (30-35%). Moisture was observed in 28% of bathrooms, in 10% of kitchens, and in 17% of other spaces. Indoor relative humidity (RH) levels were low in most homes.  相似文献   

2.
Abstract

Methods have been developed to monitor the translocation of microencapsulated cyfluthrin following perimeter applications to residential dwellings. A pilot study was implemented to determine both the potential for application spray to drift away from dwellings and the intrusion of residues into homes following perimeter treatments. Residential monitoring included measuring spray drift using cellulose filter paper and the collection of soil samples from within the spray zone. In addition, interior air was monitored using fiberglass filter paper as a sorbent medium and cotton ball swabs were used to collect surface wipes.

Fortification of matrixes resulted in recoveries of >90%. Spray drift was highest at the point of application and declined to low but measurable levels 9.1m from the foundations of dwellings. Soil residues declined to low, but measurable levels by 45 days post‐application. No cyfluthrin was measured from indoor air; however, some interior surfaces had detectable levels of cyfluthrin until three days post‐application.

Findings indicate that spray drift resulting from perimeter applications might contaminate non‐target surfaces outside the spray zone. Soil borne residues may serve as persistent sources for human exposure and potentially intrude into dwellings through the activities of occupants and pets. Residues do not appreciably translocate through air and consequently inhalation is not a likely route for human exposure. Surface residues detected indoors suggest that the physical movement of residues from the exterior to the interior might be a viable route of movement of residues following this type of application.  相似文献   

3.
Abstract

Wildfires and prescribed burns are receiving increasing attention as sources of fine particulate matter (PM2.5). The goal of this research project was to understand the impact of mitigation strategies for residences impacted by scheduled prescribed burns and wildfires. Pairs of residences were solicited to have PM2.5 concentrations monitored inside and outside of their houses during four fires. The effect of using air cleaners on indoor PM2.5 was investigated, as well as the effect of keeping windows closed. Appropriately sized air cleaners were provided to one of each pair of residences; occupants of all of the residences were asked to keep windows shut and minimize opening of exterior doors. Additionally, residents were asked to record all of the activities that may be a source of particulate matter, such as cooking and cleaning. Measurements were made during one prescribed burn and three wildfires during the 2002 fire season. Outdoor 24‐hr average PM2.5 concentrations ranging from 6 to 38 µg/m3 were measured during the fires, compared with levels of 2–5 µg/m3 during background measurements when no fires were burning. During the fires, PM2.5 was <3 µg/m3 inside all of the houses with air cleaners installed. This corresponds with a decrease of 63–88% in homes with the air cleaners operating when compared with homes without air cleaners. In the homes without the air cleaners, measured indoor concentrations were 58–100% of the concentrations measured outdoors.  相似文献   

4.
Any risk assessment of moisture-damaged buildings requires an accurate characterization of the factors contributing to the human exposure. In this study, the size distributions of indoor air viable fungi and bacteria and average mean diameters of the most common fungi in school buildings were determined. One special focus was to analyze how the microbial size distributions are affected by the building frame (either wooden or concrete) and moisture damage in the building. The study was performed in 32 school buildings classified as moisture-damaged (index) and non-damaged (reference) schools according to technical building investigations. Sampling for indoor air microbes was carried out using a cascade impactor that collects particles on six stages (range from 0.65 to >7 μm) according to their aerodynamic diameters. Both wooden and concrete schools had their highest fungal levels in the size range of 1.1–4.7 μm. However, the concentrations of fungi in all size classes were higher in wooden schools than in concrete schools. Moisture damage-associated differences in size distribution, in the particle size range of 1.1–2.1 μm, were seen in concrete schools but not in wooden schools. In general, the average geometric mean diameter (dg,ave) of total viable fungi was smaller in wooden schools than in concrete schools, and smaller in index schools of both construction types than in their reference schools. Variation in particle size, however, by genus was observed. No differences in particle size distributions of viable airborne bacteria were found. Our results on the dependency of the particle size on the building type and presence of moisture damage provide an interesting point to be considered in assessing the complex issue of indoor-related bioaerosol exposures.  相似文献   

5.
Residences located within 20 km of the damaged Fukushima Daiichi Nuclear Power Plant were evacuated shortly after the Great East Japan Earthquake. The levels of airborne and surface fungi were measured in six houses in the evacuation zone in August 2012 and February 2013. Airborne fungal levels in all of the houses in the summer were higher than the environmental standard levels for residential houses published in Architectural Institute of Japan (>1000 colony-forming units [CFU]/m3). In two houses whose residents rarely returned to visit, fungal levels were extremely high (>52,000 CFU/m3). Although fungal levels in the winter were much lower than those in the summer, they were still higher than environmental standard levels in several houses. Indoor fungal levels were significantly inversely related to the frequency with which residents returned, but they were not correlated with the air exchange rates, temperature, humidity, or radiation levels. Cladosporium spp. and Penicillium spp. were detected in every house. Aspergillus section Circumdati (Aspergillus ochraceus group) was also detected in several houses. These fungi produced ochratoxin A and ochratoxin B, which have nephrotoxic and carcinogenic potential. The present study suggests that further monitoring of fungal levels is necessary in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone, and that some houses may require fungal disinfection.

Implications: The results suggest that residents’ health could be at risk owing to the high levels of airborne fungi and toxic fungi Aspergillus section Circumdati. Therefore, monitoring and decontamination/disinfection of fungi are strongly recommended before residents are allowed to return permanently to their homes. In addition, returning to home with a certain frequency and adequate ventilation are necessary during similar situations, e.g., when residents cannot stay in their homes for a long period, because fungal levels in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone were inversely correlated with the frequency with which residents returned to visit their houses.  相似文献   


6.
As part of a larger program to investigate indoor sources of air pollution, an indoor/outdoor sampling program was carried out for NO, NO2, and CO In four private houses which had gas stoves. The four houses chosen for study represented different surrounding land use, life styles, and house age and layout. The pollutant gases were measured essentially simultaneously at three indoor locations and one outdoor location. The results of the program showed that indoor levels of NO and NO2 are directly related to stove use in the homes tested. Furthermore, these stoves often produced more NO2 than NO. In some instances, the levels of NO2 and CO in the kitchen exceeded the air quality standards for these pollutants if such outdoor standards were to be applied to indoors and the data for the sampling periods were typical of an entire year. A diffusion experiment conducted in one of the houses showed that the half-life for NO2 was less than one-third that for either NO or CO. Oxidation of NO to NO2 (based upon comparing the half-life of NO to CO) does not appear to occur to a significant degree indoors.  相似文献   

7.
Methods have been developed to monitor the translocation of microencapsulated cyfluthrin following perimeter applications to residential dwellings. A pilot study was implemented to determine both the potential for application spray to drift away from dwellings and the intrusion of residues into homes following perimeter treatments. Residential monitoring included measuring spray drift using cellulose filter paper and the collection of soil samples from within the spray zone. In addition, interior air was monitored using fiberglass filter paper as a sorbent medium and cotton ball swabs were used to collect surface wipes. Fortification of matrixes resulted in recoveries of > 90%. Spray drift was highest at the point of application and declined to low but measurable levels 9.1 m from the foundations of dwellings. Soil residues declined to low, but measurable levels by 45 days post-application. No cyfluthrin was measured from indoor air; however, some interior surfaces had detectable levels of cyfluthrin until three days post-application. Findings indicate that spray drift resulting from perimeter applications might contaminate non-target surfaces outside the spray zone. Soil borne residues may serve as persistent sources for human exposure and potentially intrude into dwellings through the activities of occupants and pets. Residues do not appreciably translocate through air and consequently inhalation is not a likely route for human exposure. Surface residues detected indoors suggest that the physical movement of residues from the exterior to the interior might be a viable route of movement of residues following this type of application.  相似文献   

8.
Wildfires and prescribed burns are receiving increasing attention as sources of fine particulate matter (PM2.5). The goal of this research project was to understand the impact of mitigation strategies for residences impacted by scheduled prescribed burns and wildfires. Pairs of residences were solicited to have PM2.5 concentrations monitored inside and outside of their houses during four fires. The effect of using air cleaners on indoor PM2.5 was investigated, as well as the effect of keeping windows closed. Appropriately sized air cleaners were provided to one of each pair of residences; occupants of all of the residences were asked to keep windows shut and minimize opening of exterior doors. Additionally, residents were asked to record all of the activities that may be a source of particulate matter, such as cooking and cleaning. Measurements were made during one prescribed burn and three wildfires during the 2002 fire season. Outdoor 24-hr average PM2.5 concentrations ranging from 6 to 38 microg/m3 were measured during the fires, compared with levels of 2-5 microg/m3 during background measurements when no fires were burning. During the fires, PM2.5 was < 3 microg/m3 inside all of the houses with air cleaners installed. This corresponds with a decrease of 63-88% in homes with the air cleaners operating when compared with homes without air cleaners. In the homes without the air cleaners, measured indoor concentrations were 58-100% of the concentrations measured outdoors.  相似文献   

9.
ABSTRACT

Fifty percent of homes tested for radon in Rock Island County, IL, have radon levels above the U.S. Environmental Protection Agency (EPA) action guideline of 4 picoCuries per liter (pCi/L) of air. Therefore, the county is classified by the EPA as Zone 1 on the EPA's Map of Radon Potential. Radon-resistant new construction (RRNC) strategies for new homes are recommended by the EPA in Zone 1 areas. One city in the county, East Moline, reduced the cost of building permits for contractors volunteering to build new homes incorporating modified passive RRNC. Forty-six of 124 new homes built with passive RRNC in the city were tested during this study. Only 27 of the homes tested were below 4-pCi/L, justifying the importance of testing the system to ensure levels are below the action guideline. To provide additional support to an argument in favor of changing city building codes to the required RRNC, 23 of the homes were also tested with the systems deactivated. After systems were deactivated, 73% of the homes had radon levels above the action guideline. Four homes were sampled for bioaerosols to evaluate if passive RRNC might impact other indicators of poor indoor air quality (IAQ). The results of the research will be discussed here.  相似文献   

10.
Radon control systems were Installed and evaluated In fourteen homes In the Spokane River Valley/Rathdrum Prairie and In one home In Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurlzatlon was always more effective In these houses than SSV by depressurlzatlon In reducing Indoor radon levels to below guidelines. Basement overpressurlzatlon was successfully applied In five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace Isolation in reducing radon entry from the crawlspace, but had to be used In conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations In two houses with alr-toalr heat exchangers (AAHX) were reduced to levels Inversely dependent on the new total ventilation rates and were lowered even further In one house where the air distribution system was modified. Sealing penetrations In the below-grade surfaces of substructures was relatively Ineffective In controlling radon. Operation of the radon control systems (except for the AAHX’s) made no measureable change in ventilation rates or Indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX’s. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.  相似文献   

11.
Abstract

A pilot-scale plug-flow reactor was built to investigate its performance in treating airborne 1,3-butadiene (BD) via ozonation (O3) and ultraviolet (UV)/O3 technologies. Governing factors, such as the initial molar ratio of ozone to BD, UV volumetric electric input power, and moisture content in the influent airstream, were investigated. Experiments were conducted at an influent BD concentration of ~50 ppm, an ambient temperature of 26 °C, and a gas retention time of 85 sec. Results show that an initial molar ratio of ozone to BD of 3.5 and 2 sufficed to obtain BD decompositions of >90% for ozonation and UV/O3, respectively. The UV irradiance did not directly promote the decomposition of BD, rather, it played a role in promoting the production of secondary oxidants, such as hydroxyl radicals. Kinetic analyses indicate that both types of BD decomposition are peudo–first-order with respect to BD concentrations. Moisture content (relative humidity = 40–99%) and UV volumetric electric input power (0.147 and 0.294 W/L) are both factors that weakly affect the rate of BD decomposition. Economic evaluation factors, including both energy of ozone production and UV electric input power, were also estimated.  相似文献   

12.
Many units in public housing or other low-income urban dwellings may have elevated pesticide residues, given recurring infestation, but it would be logistically and economically infeasible to sample a large number of units to identify highly exposed households to design interventions. Within this study, our aim was to devise a low-cost approach to identify homes in public housing with high levels of pesticide residues, using information that would allow the housing authority and residents to determine optimal strategies to reduce household exposures. As part of the Healthy Public Housing Initiative, we collected environmental samples from 42 public housing apartments in Boston, MA, in 2002 and 2003 and gathered housing characteristics; for example, household demographics and self-reported pesticide use information, considering information available with and without a home visit. Focusing on five organophosphate and pyrethroid pesticides, we used classification and regression tree analysis (CART) to disaggregate the pesticide concentration data into homogenous subsamples according to housing characteristics, which allowed us to identify households and associated networks impacted by the mismanagement of pesticides. The CART analysis demonstrated reasonable sensitivity and specificity given more extensive household information but generally poor performance using only information available without a home visit. Apartments with high concentrations of cyfluthrin, a pyrethroid of interest given that it is a restricted use pesticide, were more likely to be associated with Hispanic residents who resided in their current apartment for more than 5 yr, consistent with documented pesticide usage patterns. We conclude that using CART as an exploratory technique to better understand the home characteristics associated with elevated pesticide levels may be a viable approach for risk management in large multiunit housing developments.  相似文献   

13.
Indoor and outdoor carbonyl concentrations were measured simultaneously in 12 urban dwellings in Beijing, Shanghai, Guangzhou, and Xi’an, China in summer (from July to September in 2004) and winter (from December 2004 to February 2005). Formaldehyde was the most abundant indoor carbonyls species, while formaldehyde, acetaldehyde and acetone were found to be the most abundant outdoor carbonyls species. The average formaldehyde concentrations in summer indoor air varied widely between cities, ranging from a low of 19.3 μg m−3 in Xi’an to a high of 92.8 μg m−3 in Beijing. The results showed that the dwellings with tobacco smoke, incense burning or poor ventilation had significantly higher indoor concentrations of certain carbonyls. It was noticed that although one half of the dwellings in this study installed with low emission building materials or furniture, the carbonyls levels were still significantly high. It was also noted that in winter both the indoor and outdoor acetone concentrations in two dwellings in Guangzhou were significantly high, which were mainly caused by the usage of acetone as industrial solvent in many paint manufacturing and other industries located around Guangzhou and relatively longer lifetime of acetone for removal by photolysis and OH reaction than other carbonyls species. The indoor carbonyls levels in Chinese dwellings were higher than that in dwellings in the other countries. The levels of indoor and ambient carbonyls showed great seasonal differences. Six carbonyls species were carried out the estimation of indoor source strengths. Formaldehyde had the largest indoor source strength, with an average of 5.25 mg h−1 in summer and 1.98 mg h−1 in winter, respectively. However, propionaldehyde, crotonaldehyde and benzaldehyde had the weakest indoor sources.  相似文献   

14.
Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m?3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m?3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.  相似文献   

15.
This study used several real-time and filter-based aerosol instruments to measure PM2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM2.5 mass concentration compared to the PMI2.5 filter. The pDR-1500 direct reading and PMI2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R2 = 0.936 for OPC versus pDR-1500 reading and R2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties.

Implications: This study used several real-time and filter-based aerosol instruments to measure PM2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.  相似文献   


16.
Formaldehyde (HCHO) is still a major indoor air pollutant in Japanese air-tight houses and is the subject of numerous complaints regarding health disorders. Authors have developed a passive-type air-cleaning material and an air cleaner using manganese oxide (77% MnO2) as an active component and successfully reduced indoor HCHO concentrations in newly built multi-family houses. In this study, the reactivity between manganese oxide and HCHO was discussed. We tested the removal efficiencies of several metal oxides for HCHO in a static reaction vessel and found manganese oxide could react with HCHO and release carbon dioxide even at room temperature. The reactivity and mechanisms were discussed for the proposed chemical reactions. A mass balance study proved that a major product through the heterogeneous reaction between manganese oxide and HCHO was carbon dioxide. Harmful by-products (HCOOH and CO) were not found.  相似文献   

17.
Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate. The PCBtot levels in the air of the contaminated section were 168-3843 ng m−3 (mean: 1030 ng m−3), while the mean levels in the reference apartments were 6.03 ng m−3. The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221 680 mg kg−1. Principal component analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e.g. for PCB 28air and 28seal (p = 0.04) and for PCB 28air and 52air, 52seal. However, no correlation was observed between the lower chlorinated congeners and the sums of PCB (∑PCB6 or ∑PCB24) or the higher chlorinated congeners. Analysis of air concentrations in relation to questionnaire data indicated that the indoor air levels could be reduced by increased cleaning and airing frequencies.  相似文献   

18.
An indoor air quality assessment was conducted on 100 homes of recent Mexican immigrants in Commerce City, Colorado, an urban industrial community north of Denver. Head of households were administered a family health survey, filled out an activity diary, and participated in a home inspection. Carbon monoxide (CO) and carbon dioxide (CO2) were measured for 24 h inside the main living area and outside of the homes. Harvard Impactors were used to collect 24-h samples of PM2.5 at the same locations for gravimetric analysis. Dust samples were collected by vacuuming carpeting and flooring at four locations within the home and analyzed by ELISA for seven allergens. Mean indoor and outdoor PM2.5 levels were 27.2 and 8.5 μg m−3, respectively. Indoor PM2.5 and CO2 were elevated in homes for which the number of hours with door/window open was zero compared to homes in which the number of hours was high (>15 h). Indoor PM2.5 levels did not correlate with outdoor levels and tended to increase with number of inhabitants, and results indicate that the source of indoor particles were occupants and their activities, excluding smoking and cooking. Mean indoor CO2 and CO levels were 1170 and 2.4 ppm, respectively. Carbon monoxide was higher than the 24-h National Ambient Air Quality Standard in 3 of the homes. The predominant allergens were cat (Fel d 1) and mouse (Mus m 1) allergens, found in 20 and 34 homes, respectively.  相似文献   

19.
We have developed a board-like air-cleaning material consisting of activated carbon particles and manganese oxides, by which HCHO gas is decomposed into carbon dioxide even at room temperature. In this study, we investigated removal efficiencies of the air-cleaning board in a passive mode using a kinetic approach. First-order removal rate constant, k, corresponding to air change rate was characterized for the board as a function of the ratio of applied board area to space volume, S/V, and was found directly proportional to S/V with a slope of 25 at 25°C. The performance of the board was evaluated in a full-size laboratory with a constant gas generation. The board suppressed the increase of indoor HCHO concentration and the time course fitted to a theoretical curve. Then, field tests of the air-cleaning board were conducted in newly constructed multi-family houses in Japan from May 1998 to January 1999. The board not only reduced indoor HCHO concentration from 0.21 to 0.04 ppm for more than 7 months, but also enhanced the loss of HCHO gas from building materials in apartments.  相似文献   

20.
Indoor dust samples were collected from 40 homes in Kocaeli, Turkey and were analyzed simultaneously for 14 polybrominated diphenyl ethers (PBDEs) and 16 poly aromatic hydrocarbons (PAHs) isomers. The total concentrations of PBDEs (Σ14PBDEs) ranged from 29.32 to 4790 ng g?1, with a median of 316.1 ng g?1, while the total indoor dust concentrations of 16 PAHs (Σ16PAHs) extending over three to four orders of magnitude ranged from 85.91 to 40,359 ng g?1 with a median value of 2489 ng g?1. Although deca-PBDE products (BDE-209) were the principal source of PBDEs contamination in the homes (median, 138.3 ng g?1), the correlation in the homes was indicative of similar sources for both the commercial penta and deca-PBDE formulas. The PAHs diagnostic ratios indicated that the main sources of PAHs measured in the indoor samples could be coal/biomass combustion, smoking, and cooking emissions. For children and adults, the contributions to ∑14PBDEs exposure were approximately 93 and 25 % for the ingestion of indoor dust, and 7 and 75 % for dermal contact. Exposure to ∑16PAHs through dermal contact was the dominant route for both children (90.6 %) and adults (99.7 %). For both groups, exposure by way of inhalation of indoor dust contaminated with PBDEs and PAHs was negligible. The hazard index (HI) values for BDE-47, BDE-99, BDE-153, and BDE-209 were lower than the safe limit of 1, and this result suggested that none of the population groups would be likely to experience potential health risk due to exposure to PBDEs from indoor dust in the study area. Considering only ingestion + dermal contact, the carcinogenic risk levels of both B2 PAHs and BDE-209 for adults were 6.2 × 10?5 in the US EPA safe limit range while those for children were 5.6 × 10?4 and slightly higher than the US EPA safe limit range (1 × 10?6 and 1 × 10?4). Certain precautions should be considered for children.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号