首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A prospective study of maternal serum human chorionic gonadotrophin (hCG) measurement for the selection of pregnancies with an increased risk of fetal trisomy 21 was undertaken in 24 000 pregnancies from 1 January 1989 to 31 December 1990. Maternal serum was sampled at 15-18 weeks of gestation. hCG was measured in one laboratory, with one technique. This ‘hCG high level’ technique was developed for this screening. Amniocentesis was offered to each woman with a maternal serum hCG level above the cut-off. The follow-up of the pregnancies is known in 92 per cent of cases. The combination of hCG values and maternal age gave a detection efficiency of 63 per cent for trisomy 21 with rates of amniocentesis of 30 per cent for patients aged 37 years, 20 per cent for patients aged 35 or 36 years, and 5 per cent for patients under 35 years of age. Based on this prospective study, an individual risk was calculated combining the serum hCG value and maternal age. Seventy-four per cent of trisomy 13, trisomy 18, triploidy, and 5p- deletion were detected either in the same selected group of women or in combination with ultrasonography performed when hCG values were very low. The follow-up study showed that women who had high or low hCG values represented a group at high risk for fetal or perinatal death.  相似文献   

2.
We analysed maternal serum human chorionic gonadotropin (hCG) in 16 pregnancies with fetal abdominal wall defects previously identified prenatally by elevated maternal serum alpha-fetoprotein (AFP) or at birth. The AFP levels had a mean of 6·38 MOM (range 0·34–15·65), as expected with these defects. The hCG levels had a mean of 1·82 MOM (range 0·23–4·11). The hCG levels in five pregnancies (31·25 per cent) were above 2·30 MOM. Elevated levels of hCG may be associated with fetal abdominal wall defects.  相似文献   

3.
The effectiveness and costs of prenatal screening programmes for Down's syndrome using maternal serum markers will vary significantly depending on the biological cut-off values chosen in order to select women, at each maternal age, who will be sent for amniocentesis. On the basis of the first French prospective study of human chorionic gonadotropin (hCG) measurement in maternal serum, this paper shows that the screening protocol currently used in France, where hCG cut-off values are defined in order to offer amniocentesis to women of all ages with a 1 percent fetal risk of Down's syndrome, would detect 64·06 per cent of all cases of trisomy 21 at birth and would be highly profitable for the French social security system. On the basis of a representative sample of 100 000 pregnant women, the total costs of screening would reach $8 302 000 but would generate net potential savings of $32 186 000 in terms of life-long costs of care for trisomic 21 children which would be ‘avoided’ by termination of pregnancy following a positive diagnosis of Down's syndrome. Economic assessment shows that cost-benefit analysis would justify lower hCG cut-off values and a higher detection rate of fetal Down's syndrome (74·45 per cent) than the current French protocol. This paper concludes that it is ethical and value-laden issues, such as the consequences for women and couples of false positives and false negatives of screening, rather than economic and financial arguments that may set limits to the utilization of screening for Down's syndrome using maternal serum markers like hCG.  相似文献   

4.
Urinary gonadotropin peptide (UGP; β-core fragment), a major metabolite of human chorionic gonadotropin (hCG), was shown recently to be markedly elevated in Down syndrome pregnancy between 19 and 22 weeks of gestation. To confirm and extend this finding, we obtained maternal urine and matching maternal serum samples from 14 cases of Down syndrome and six other aneuploidies between 17 and 21 weeks of gestation. UGP was measured in all these samples and in 91 singleton control urines. Results were corrected for urinary creatinine level and expressed as multiples of the control median (MOM). hCG levels were assayed in all serum samples from the cases and compared with previously established reference values. The median UGP level in Down syndrome cases was 5.34 MOM (range 2.71–12.57); 88 per cent of the values were above the 95th centile of control levels after modelling. The median maternal serum hCG level for the same cases was 2.20 MOM (range 0.84–3.40); 36 per cent of the values were above the 95th centile. The level of UGP in every case including all other aneuploidies was higher than the comparable maternal serum hCG level. Elevated UGP measurements are strongly associated with fetal Down syndrome during the second trimester and could contribute to improved Down syndrome screening protocols that are more accessible and less expensive than are currently available.  相似文献   

5.
Maternal serum human chorionic gonadotropin (hCG) and the free alpha-hCG subunit were evaluated in 249 women from 9 to 11 weeks gestation who subsequently underwent chorionic villus sampling for determination of fetal karyotype and in 20 women of 18 or more weeks gestation who were ascertained to have an aneuploid fetus by genetic amniocentesis. Seven of the first-trimester pregnancies were determined to be aneuploid and six had hCG levels in the normal range (one triploid pregnancy had elevated hCG levels) whereas 12 of the 20 secondtrimester cases had abnormal hCG levels and an additional three had elevated levels of alpha-hCG. This study confirms the previous report of abnormal maternal serum hCG levels in women with an aneuploid fetus at ≥ 18 weeks gestation and demonstrates that hCG evaluation is not useful at 9–11 weeks gestation for selecting pregnancies at risk for fetal aneuploidy.  相似文献   

6.
An association is described between women with lupus anticoagulant and abnormal prenatal serum screening results. Three cases of positive second-trimester serum screening for Down syndrome, with karyotypically normal fetuses, in women demonstrated to have lupus anticoagulant are presented. Serum screening positivity was principally due to a disproportionately elevated maternal serum human chorionic gonadotrophin (hCG) level. In each case, early, severe intrauterine growth restriction was documented, with only one fetus surviving the neonatal period. As maternal lupus anticoagulant may have a profoundly adverse effect on the course of pregnancy, we suggest that an elevated hCG level on prenatal screening prompt consideration of maternal lupus anticoagulant testing if ultrasonography demonstrates an otherwise normal singleton gestation and the fetal karyotype is normal.  相似文献   

7.
An alternative method to the culture of amniotic fluid cells for prenatal diagnosis of chromosome disorders is proposed. Microculture of fetal blood can be used when fetal blood is drawn at amniocentesis through accidental puncture of the placenta. An easy discrimination of fetal red cells, a good response of fetal lymphocytes to PHA and the possibility of identification of the fetal karyotype from the maternal one are the technical bases of this method. This technique offers some undoubted advantages: a reduced need for repeating amniocentesis because of a lack of growth of AF cells due to massive contamination with red cells; a result may be obtained sooner. Thirty-seven cases out of 1092 amniocenteses were processed in this way (3·4 per cent). In two cases no mitoses were obtained but in the others the diagnosis was confirmed by the results of AF cell culture and/or by the outcome of pregnancy.  相似文献   

8.
Human chorionic gonadotrophin (hCG) levels were assayed retrospectively in stored maternal serum samples from 78 chromosomally abnormal pregnancies and 410 controls matched for gestation and maternal age. The median serum hCG concentration in 49 pregnancies with Down's syndrome was significantly elevated, at 2.18 multiples of the normal median. Significantly reduced hCG concentrations were found in a group of four trisomy 18 pregnancies (all less than 0.4 multiples of the median). Eight cases of unbalanced chromosome rearrangements appeared to show some lowering of hCG levels, while there was no significant difference in the levels in the cases of trisomy 13, balanced translocations, and sex chromosome abnormalities. Maternal serum hCG alone is a better indicator of Down's syndrome pregnancies than maternal age or maternal serum alpha-fetoprotein (AFP), either individually or in combination, and provides a further virtually independent measure of risk. On the basis of our findings, screening for Down's syndrome using hCG and AFP results combined with maternal age risks is predicted to result in a higher detection rate (57 per cent) for a lower false-positive rate (5.0 per cent) than would be attainable by combined AFP and age screening (37 per cent detection at a 6.6 per cent false-positive rate).  相似文献   

9.
Maternal cell contamination of chorionic villi (CV) samples used for first trimester prenatal diagnosis can cause obvious and/or unrecognized diagnostic dilemmas. The purpose of this investigation is to assess the frequency of maternal cell contamination (MCC) in chorionic villus samples and to evaluate selected parameters which might predict where contamination is more likely to have occurred. Maternal lymphocytes, chorionic villi from ultrasonically directed transcervical catheter aspiration, and fetal tissue were obtained at 8–11 weeks gestation from 45 patients undergoing elective termination. Quinacrine (Q) banded metaphases were compared from duplicate direct preparations of chorionic villi; cultured chorionic villi, fetal fibroblast tissue cultures, and maternal lymphocyte cultures. Q-polymorphisms in metaphase chromosomes were 100 per cent concordant between fetal tissue and direct CV preparation. However, evidence for maternal cell contamination occurred in 13.1 per cent of cultured chorionic villi preparations where polymorphisms were found to be identical between maternal and cultured CV and both distinct from fetal tissue preparations. Where MCC was identified, it was noted that CV cell cultivation interval was prolonged (24.2±6.8 days) compared with non-contaminated cultures (14.1±4.4 days) (p <0.05). We conclude that maternal cell contamination is a significant problem with chorionic villus sampling. Where direct preparations are not employed or when cultures are ‘slow growing’, MCC may be a significant and unrecognized complication re: fetal diagnosis. Direct preparations, multiple cultures, quinacrine banding, and maternal Q-polymorphism comparisons can minimize diagnostic dilemmas secondary to maternal cell contamination. Q-polymorphism comparisons between maternal and fetal chromosomes should be included in all instances where cultured chorionic villi are utilized for fetal diagnosis and where direct preparations are not available.  相似文献   

10.
We report the preliminary results of a prospective study aimed at evaluating the effectiveness of Down syndrome (DS) screening using second-trimester measurement of maternal serum human chorionic gonadotrophin (hCG) and unconjugated oestriol (uE3) together with maternal age. Reference values for hCG, uE3, and the hCG/uE3 ratio in normal pregnancies were established from more than 3000 normal gestations and found to follow a log-normal statistical distribution. Risk evaluation was made using reference values for affected pregnancies from retrospective studies. Screening of 10 000 women under 38 years resulted in 412 amniocenteses and the prenatal diagosis of six cases of DS, whereas four cases remained undetected until term. In a parallel study, diagnostic amniocentesis was performed in women over 38 years and in women with a previous affected child, and an evaluation of the risk of fetal DS based on serum hCG and uE3 levels was made in all cases. Fourteen cases of DS were detected. Median values for hCG and uE3 in the 24 affected pregnancies were close to the 90th and tenth centiles of the normal reference values, respectively, and thus are in good agreement with the values reported by others in retrospective studies.  相似文献   

11.
We assayed maternal serum samples from 134 black and 268 white women from 16 to 18 weeks of gestation for intact human chorionic gonadotropin (hCG), and unconjugated oestriol (uE3). Serum from women with high ( ⩾ 2·5 MOMs) or low (risk for Down syndrome ⩾ 1/365) maternal serum alpha-fetoprotein (MSAFP) levels were excluded. After correcting for maternal weight, we found that median hCG levels were 16 per cent higher in black women but uE3 levels were not significantly different. These results confirm three other studies for hCG and one study for uE3. Corrections are recommended for both maternal serum hCG and AFP before calculating the risk for Down syndrome in black women.  相似文献   

12.
The alpha subunit of human chorionic gonadotropin (alpha-hCG), human chorionic gonadotropin (hCG) and alpha fetoprotein (AFP) were measured in the serum of 25 women with chromosomally abnormal fetuses between 18 and 25 weeks of gestation and in 74 normal pregnancies. AFP levels less than 0.5 multiples of the median (MoM) or greater than 2.5 MoM were observed in 24 per cent of the abnormal pregnancies and in 6.76 per cent of the normal pregnancies. A low concentration of hCG (< 0.25 MoM) was observed in 8 per cent of abnormals and in 2.7 per cent of normals while an elevated concentration of hCG (>2.5 MoM) was observed in 56 per cent of abnormals and in 1.35 per cent of normals. Elevated hCG-alpha (>2.5 MoM) was observed in 28 per cent of abnormals and in none of the normals. Determination of elevated levels of hCG-alpha or hCG resulted in detection of 68 per cent of pregnancies with chromosomally abnormal fetuses with a false positive rate of 1.35 per cent. Determination of both elevated and depressed gonadotropin levels resulted in detection of 76 per cent of abnormal pregnancies with a false positive rate of 4.05 per cent. Measurement of hCG and hCG-alpha in maternal serum samples can be used as a screening procedure for detecting pregnancies at risk for fetal chromosome abnormalities.  相似文献   

13.
Unconjugated oestriol (uE3) and human chorionic gonadotropin (hCG) levels were determined in second-trimester maternal serum (MS) samples from 21 pregnancies associated with fetal anencephaly and 15 pregnancies associated with fetal open spina bifida. Each measurement was expressed as a multiple of the median (MoM) for unaffected pregnancies for each completed week of gestation. In pregnancies associated with anencephaly, the median value for MSuE3 was very low (0–17 MoM, range <0·12–0·33 MoM), suggesting a functional defect in the fetal adrenal prior to 20 weeks' gestation; the median value for MShCG was also low (0–73 MoM), although not to the same extent as for MSuE3. A biological explanation for the hCG result is not apparent. In pregnancies associated with open spina bifida, the MSuE3 and MShCG values were unremarkable, consistent with a lack of involvement of these open fetal defects in the synthesis and secretion of uE3 and hCG.  相似文献   

14.
The amount of fetal—maternal transfusion during invasive intrauterine diagnostic instrumentation was determined by measuring the increase in maternal serum alpha-fetoprotein (Δ AFP) caused by the procedure. Fetal liver biopsy or fetoscopy for purposes other than blood sampling caused a mean Δ AFP of 11.4 ng/ml and 34.2 ng/ml, respectively. Fetoscopy with fetal blood sampling produced a mean Δ AFP of 211.8 ng/ml, while fetoscopy followed by placentesis caused a mean Δ AFP of 462.8 ng/ml (representing a 1.07 ml fetal—maternal transfusion). Although this magnitude of fetal—maternal transfusion is an acceptable risk for the fetus, it is a sufficient transfusion to cause blood cell antigen sensitization.  相似文献   

15.
In order to gain more insight into the association between alpha-fetoprotein (AFP) and fetal chromosomal disorders, especially Down's syndrome, we measured AFP in fetal serum, amniotic fluid, and maternal serum at cordocentesis. We compared the concentration and gradient of AFP in these three compartments. Our data confirm earlier findings on second-trimester fetal serum AFP concentration. The results indicate that low maternal serum AFP in pregnancies with fetal chromosomal disorders could result from an impaired fetal kidney function as well as from impaired membrane or placental passage of AFP, rather than from reduced fetal AFP production.  相似文献   

16.
First trimester sonographic markers are the only markers achieving detection rates above 50% in the prenatal detection of fetal aneuploidy. Although potentially they are the best markers, some concerns have arisen about its clinical application. Pitfalls may be due to inability to examine the markers, incorrect assessment, or incorrect interpretation of the findings. Markers may be unable to be examined due to maternal (maternal body habitus, previous surgery) or fetal reasons (incompatible fetal position or fetal movements). Causes of incorrect interpretation may be insufficient image magnification, incorrect caliper placement (nuchal translucency), incorrect insonation angle (nasal bone), venous contamination (ductus venosus), or arterial contamination (tricuspid regurgitation), among others. Venous contamination in ductus venosus waveforms may mimic an abnormal blood flow when it is normal, and the opposite can also occur. Finally, incorrect interpretation of a substantially increased nuchal translucency may lead to a false impression of an ominous fetal prognosis or may be confounded with a cystic hygroma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
Maternal serum human thyroid-stimulating hormone (TSH) levels were investigated in chromosomally normal and Down syndrome pregnancies to determine whether TSH can be used as a marker for Down syndrome in the first trimester. Measurements were conducted on stored serum samples collected from 23 Down syndrome pregnancies and 115 unaffected pregnancies before chorionic villus sampling (CVS), between 9 and 11 completed weeks of pregnancy. The samples were matched for gestational age, maternal age, maternal weight and duration of storage of the serum sample. Maternal TSH concentration was slightly decreased in Down syndrome pregnancies, with a median of 0.84 multiples of the median (MoM). Maternal serum human chorionic gonadotropin (hCG) concentration was slightly elevated in Down syndrome pregnancies, with a median of 1.03 MoM. Both differences were not significant applying matched rank analysis (p=0.50 for TSH and p=0.43 for hCG). The association between TSH and hCG in unaffected pregnancies was also measured. The Spearman correlation coefficient between TSH and hCG was −0.21 which was statistically significant (p=0.02, 95% confidence interval −0.38 to −0.03). However, it was concluded that TSH is not a useful marker for distinguishing Down syndrome-affected pregnancies from normal pregnancies in the first trimester. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

18.
Shortened fetal long bones (SFLB) are usually indicative of a skeletal dysplasia. Our aim in this observational retrospective study was to describe a new association between SFLB, small for gestational age (SGA) fetuses and placental abnormalities, and to suggest an aetiologic explanation. During the last decade we have evaluated nine cases in which SFLB (more than 2SD below the mean) was associated with SGA, abnormal maternal serum placental hormones and abnormal placental sonography. Six cases had significantly increased second trimester maternal serum βhCG and four developed toxaemia of pregnancy or had chronic hypertension. On histology, mature placentas with vascular abnormalities, including chorangiosis, large infarcts and slightly increased syncytial knots were noted. The combination of SFLB, SGA fetuses and placental abnormalities (sonographic, as well as histological) suggested a possible common pathway in the aetiology of this association. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

19.
Pure fetal blood, (uncontaminated with maternal blood), was obtained from two male fetuses at risk for X-linked mental retardation with fragile(X) at Xq27–28 by direct vision fetoscopy and fetal blood sampling. Both were shown to have this fragile site on the X chromosome while nine other fetal blood samples from pregnancies at risk for other X-linked diseases, or haemoglobinopathies did not show fragile sites at Xq27–28, and a blood sample from an abortus showed only 1 fragile site in 95 mitoses. Both pregnancies were terminated, cultures established from fetal tissues, and the diagnosis confirmed in each case. The problems of demonstrating the fragile site in tissues other than fetal blood in these pregnancies (such as amniotic fluid cells or fibroblasts from fetal tissues) are discussed.  相似文献   

20.
The value of measuring the separate sub-units of human chorionic gonadotrophin (free α-hCG and free β-hCG) instead of total hCG together with alpha-fetoprotein (AFP) and unconjugated oestriol (uE3) was examined to determine the effect on the performance of serum screening for Down's syndrome between 15 and 22 weeks of pregnancy. The study was based on stored serum samples relating to 75 singleton pregnancies with fetal Down's syndrome and 367 unaffected singleton pregnancies, matched for maternal age, gestational age, and duration of storage of the serum sample, supplemented by data from 970 white women with unaffected pregnancies. Using the four serum markers AFP, uE3, free β-hCG, and free α-hCG, in addition to maternal age, 65 per cent of Down's syndrome pregnancies were detected for a 5 per cent false-positive rate compared with 59 per cent with the conventional triple test (AFP, uE3, total hCG with maternal age). If gestation was based on an ultrasound scan examination, the detection rate was 72 per cent using the four serum markers compared with 67 per cent with the triple test. As an alternative illustration, if the detection rate was kept at 60 per cent and gestation was estimated by an ultrasound scan examination the four-marker test reduced the false-positive rate by one-third from 3 per cent using the triple test to 2 per cent with the four-marker test. Screening performance was hardly affected by adjusting marker levels for maternal weight. The four-marker test is, both from a medical and from a financial perspective, the most effective method of prenatal screening for Down's syndrome suitable for routine use.  相似文献   