首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this article, the comparison of the energetic performance of a binary cycle and a modified binary cycle with flash evaporation is presented, both using a low-enthalpy geothermal resource. The comparative analysis is based on two main discourses: the first one evaluates a conventional binary cycle (CBC) with isopentane as working fluid in order to validate and compare the generated data with those reported in similar studies; the second one uses the same input parameters for both cycles, obtaining the cases in which the modified binary cycle is the most viable choice to use. In addition to the above, several aspects are considered when selecting the most suitable working fluid, and the use of water as working fluid is introduced. When the temperature of the geothermal resource is below 140 °C, and the ambient temperature is 25 °C, the flash evaporation binary cycle, using water as working fluid, shows an improved performance compared to a CBC, with a theoretical output over 1000 kWe. This may encourage new areas of opportunity for power generation, not only with low- and medium-enthalpy geothermal energy, but also with other renewable energy sources such as solar.  相似文献   

2.
This paper compares an existing unreliable grid supply with a proposed PV–biodiesel hybrid energy system in order to find the feasibility of the latter for improvement in reliability of power supply, lower pollutant emissions and saving of coal reserves. In the present study, the electrical load of a cement technology institute located in Bhilai, India, has been selected for the purpose of analysis. The results show that hybrid PV–biodiesel system comprising 25 kW PV array, 8 kW biodiesel generator-1, 20 kW biodiesel generator-2, 10 kW inverter and 10 kW rectifier will supply power to the institute avoiding addition of 27.744 tons of CO2 in atmosphere and save 55,080 kg of coal per year with improvement in reliability from 93.15 to 100%.  相似文献   

3.
The behaviour of a decentralized polygeneration plant providing synthetic natural gas (SNG), steam and electrical power is simulated in three scenarios in this study. The plant size is based on an assumed capacity of decentralized polygeneration plants processing 1070 m3 h?1 (STP) of syngas. 396 m3 h?1 (STP) of raw SNG, 0.4 t h?1 of steam at 5 bar and 670 kW of electrical power can be generated by the plant at the reference scenario. Methanation reactor and steam generator are modelled in detail. Further results indicate that such a polygeneration plant can provide positive and negative operation reserves for the electricity network to the extent of 100% of the reference power output, while the amount of generated steam varies by less than 40%. At the same time, the generated SNG quality keeps constant. Lower variations in the amount of generated steam are applicable when reducing the operation reserve capacity.  相似文献   

4.
Hybrid energy systems are renewable energy system combined in a complementary fashion to ensure dependable power supply at competitive cost. Diesel generators (DGs) are also added here as a back-up source of supply. For remote areas far from a transmission grid, these systems can provide a reliable and cost-effective supply. Addition of DG could instigate environmental pollution in such remote unpolluted areas. In the present work, optimal sizing of hybrid energy system has been attempted for a remote village cluster of Uttarakhand (India) to make available desired power supply at minimum environmental effluence. Hybrid Optimization Model for Electrical Renewable (HOMER) software from National Renewable Energy Laboratory, USA has been employed to attain the objective. The software offered several feasible systems, ranked on the basis of net present cost (NPC). All such systems are further analysed for emissions they have made in the environment. Hence, the optimal system fulfilling the criteria of minimal environmental degradation with sufficiently minimum NPC has been searched for. In the present work, the most appropriate system offered on the basis of NPC is the one which has five wind turbines (10 kW each), one DG (65 kW) and 25 batteries (6 V, 6.94 kW h each). The NPC of the system is $1,252,018, whereas its initial capital cost and levelised cost of energy (COE) are $94,233 and $0.292/kW h, respectively. After further analysis of all the feasible systems on the basis of environmental effluence, the most feasible system explored is the one which has minimal emissions of various pollutants such as carbon dioxide, carbon monoxide, hydrocarbon, particulate matter, sulphur dioxide and nitrous oxide. The system has been obtained on a compromised NPC of $1,270,921 with a capital cost of $148,133 and COE of $0.296/kW h. Components of the system include five wind turbines (10 kW), a 9 kW PV panel and a 65 kW DG along with 30 batteries (6 V, 6.94 kW h each). The system so obtained would prove to be a feasible, optimally sized and sustainable power supply alternative for remote unelectrified hilly rural area.  相似文献   

5.
In light of rising cost of fossil fuels and fears of its depletion, coupled with the increase in energy demand and the rise in pollution levels, governments worldwide have had to look at alternative energy resources. Combining renewable energy generation like solar power with superior storage and conversion technology such as hydrogen storage, fuel cells and batteries offers a potential solution for a stand-alone power system. The aim of this paper was to assess the techno-economic feasibility of using a hybrid energy system with hydrogen fuel cell for application in an eco-house that will be built in Sultan Qaboos University, Muscat, Oman. Actual load data for a typical Omani house of a similar size as the eco-house was considered as the stand-alone load with an average energy consumption of 40 kW/day and 5 kW peak power demand. The National Renewable Energy Laboratory's Hybrid Optimisation Model for Electric Renewable software was used as a sizing and optimisation tool for the system. It was found that the total annual electrical energy production is 42,255 kW and the cost of energy for this hybrid system is 0.582 $/kW. During daylight time, when the solar radiation is high, the photovoltaics (PV) panels supplied most of the load requirements. Moreover, during the evening time the fuel cell mainly serves the house with the help of the batteries. The proposed system is capable of providing the required energy to the eco-house during the whole year using only the solar irradiance as the primary source.  相似文献   

6.
The regulations of process efficiency and stricter environmental policies require analysis of large-scale thermal energy systems to produce highly efficient, cost effective and low environmental impact energy. For analysis, it is beneficial to simulate an energy system. In this paper, simulation models are developed for the analysis of a combined cycle heat and power plant located in Göteborg, Sweden. With the help of simulation models, characteristics between district heating (DH) water temperature and key parameters such as overall district heat duty, electrical power and electrical efficiency has been developed. The characteristics are useful to estimate and maximize the key parameters during varying DH water temperature. According to a comparison between the full-load simulation models of 2006 and 2013 for the selected power plant, a loss of 2 MW is noticed for gas turbine and a loss of 2.18 MW of heat flow occurs for heat recovery steam generator in the year 2013. The feasibility analysis of modifying the connection between DH economizer and main DH line provides good performance indicators in a winter scenario. The conclusions in this paper are good references to plan and improve the performance of existing large-scale thermal power plants.  相似文献   

7.
ABSTRACT

Renewable and sustainable fuels for diesel engine applications provide energy protection, overseas exchange saving and address atmospheric and socio-economic concerns. This study presents the investigational work carried out on a single cylinder, four-stroke, direct injection diesel engine operated in dual fuel (DF) mode using renewable and sustainable fuels. In the first phase, a Y-shaped mixing chamber or venture was developed with varied angle facility for gas entry at 30°, 45° and 60°, respectively, to enable homogeneous air and gas mixing. Further effect of different gas and air mixture entry on the DF engine performance was studied. In the next phase of the work, hydrogen flow rate influence on the combustion and emission characteristics of a compression ignition (CI) engine operated in DF mode using diesel, neem oil methyl ester (NeOME) and producer gas has been investigated. During experimentation, hydrogen was mixed in different proportions varied from 3 to 12 l/min (lpm) in step of 3 lpm along with air-producer gas and the mixtures were directly inducted into engine cylinder during suction stroke. Experimental investigation showed that 45° Y-shaped mixing chamber resulted in improved performance with acceptable emission levels. Further, it is observed that investigation showed that at maximum operating conditions and hydrogen flow rate of 9 lpm, Diesel–producer gas and NeOME–producer gas combination showed increased thermal efficiency by 13.2% and 3.8%, respectively, compared to the DF operation without hydrogen addition. Further, it is noticed that hydrogen-enriched producer gas lowers the power derating by 5–10% and increases nitric oxide (NOx) emissions. However, increased hydrogen addition beyond the 12 lpm leads to sever knocking.

Abbreviations: NeOME: Neem oil methyl ester; BTE: brake thermal efficiency; CI: compression ignition; ITE: indicated thermal efficiency; PG: producer gas; CA: crank angle; K: Kelvin; BP: brake power; IP: indicated power; H2: hydrogen; HC: unburnt hydrocarbon; CO: carbon dioxide; CO2: carbon dioxide; NOx: nitric oxide; HRR: heat release rate; %: percentage; PPM: parts per million; CMFIS: conventional mechanical fuel injection system.  相似文献   

8.
The recent increase in energy costs, driven by a surge in oil prices, has increased world‐wide efforts on the exploitation of renewable/wind energy resources for environment‐friendly sustainable development and to mitigate future energy challenges. Moreover, experience in the wind energy industry has reached high levels in the field of manufacturing and application. This inevitably increases the merits of wind energy exploitation. In order to exploit wind resources, through the establishment of wind power plants, specific attention must be focused on the characteristics of wind and wind machines. The literature indicates that wind‐energy resources are relatively better along coastlines. In the present study, long‐term hourly mean wind speed data for the period 1986–2003, recorded at Dhahran (Eastern Coastal region, Saudi Arabia), has been analysed to examine the wind characteristics including (but not limited to): yearly/monthly/diurnal variations of wind speed, frequency distribution of wind speed, impact of hub‐height/machine‐size on energy production, etc. Data have been checked/validated for completeness. Data analysis indicated that long‐term monthly average wind speeds ranged from 3.8 to 5.8 m/s.

Concurrently, the study determined monthly average daily energy generation from different sizes of commercial wind machines (150, 250, 600 kW, etc.) to assess the impact of wind machine size on energy yield. The study also estimated annual energy production (MWh/year) from wind farms of different capacities (3, 6, 12, 24 MW, etc.) by utilising different commercial wind energy conversion systems (WECS). It was observed that, for a given 6 MW wind farm size, a cluster of 150 kW wind machines (at 50 m hub‐height) yielded about 32% more energy when compared to a cluster of 600 kW wind machines. The study also estimated the cost of wind‐based electricity (COE, US$/kWh) by using different capacities of commercial WECS. It was found that the COE per kWh is 0.045 US$/kWh for 150 kW wind machine (at 50 m hub‐height) whereas COE was 0.039 US$/kWh for 600 kW wind machine (at 50 m hub‐height). The study also dealt with wind turbine characteristics (such as capacity factor and availability factor). These characteristics are important indicators of wind turbine performance evaluation.  相似文献   

9.
The accumulation of dust pollution on the photovoltaic (PV) module can have a significant effect on the productivity and efficiency of PV systems in different locations in the world. Dust which accumulated over time on the PV module and is based on weather conditions led to the reduction in the effectiveness of solar cells. The aim of this research was to experimentally investigate the effect of the natural dust and the effects of environmental parameters on PV performance. The experiments were conducted to propose a model for the current, voltage, power and efficiency and to simulate the effect of environmental parameters on PV performance. The natural dust investigated consisted of different compounds: SiO2 (45.53 %), CaO (24.62 %), Al2O3 (10.83 %), Fe2O3 (10.46 %), MgO (6.33 %), K2O (0.87 %), TiO2 (0.45 %), SO3 (0.24 %), MnO2 (0.21), Cr2O3 (0.23 %), SrO (0.13 %) and NiO (0.09 %). It was found that the most accurate correlation is a polynomial from seventh degree for current, voltage, power and efficiency, fourth degree for solar radiation and temperature, cubic degree for humidity and wind velocity. The coefficients of general model are 0.6343, 0.0110, 0.0 and 0.0001 for PV module, respectively, with 0.0011 fitting factor. The proposed model has been validated using models in the literature.  相似文献   

10.
Performance analysis of a gas turbine with two configurations (a parallel and series free turbine) is presented and analysed. A simple configuration is analysed here for comparison. The performance parameters are work output, specific fuel consumption (SFC) and efficiency. Off-design characteristics are based on two methods of control, the first (A) is fixing the compressor–turbine inlet temperature (TIT) and varying the power TIT, whereas the second (B) method is by varying the two turbine-inlet temperatures while keeping them equal. Conclusively the series configuration has higher work output (11%), whereas the parallel arrangement has higher efficiency and lower SFC (9%). Hence, as a compromise, it is more efficient and work-productive to use method A (TIT = const.) to control both series and parallel arrangements than using method B (TIT = T5).  相似文献   

11.
Today, energy occupies a pivotal position around which all socio-economic activities revolve. No energy means no life, and supply of energy in a cheap, plentiful, long-sustainable and environmentally safe form is a boon for everyone. In the light of rising cost of oil and fears of its exhaustion coupled with increased pollution, the governments worldwide are deliberating and making huge strides to promote renewable energy sources such as wind. Integration of wind machines with the diesel plants is pursued widely to reduce dependence on fossil-fuel-produced energy and to reduce the release of carbon gases that cause global climate change. The literature indicates that commercial/residential buildings in the Kingdom of Saudi Arabia (KSA) consume an estimated 10–40% of the total electric energy generated. The aim of this study is to analyse wind-speed data of Dhahran (East-Coast, KSA) to assess the economic feasibility of utilising autonomous hybrid wind–diesel power systems to meet the electrical load of 100 typical residential buildings (with annual electrical energy demand of 3512 MWh). The monthly average wind speeds range from 3.3 to 5.6 m/s. The hybrid systems simulated consist of different combinations of 600 kW commercial wind machines supplemented with diesel generators. The National Renewable Energy Laboratory's hybrid optimisation model for electric renewables software was employed to perform the techno-economic analysis.

The simulation results indicate that for a hybrid system comprising 600 kW wind capacity together with a 1.0 MW diesel system (two 500 kW units), the wind penetration (at 50 m hub-height, with 0% annual capacity shortage) is 26%. The cost of generating energy (COE, $/kWh) from this hybrid wind–diesel system was found to be 0.070 $/kWh (assuming diesel fuel price of 0.1 $/l). The study exhibits that for a given hybrid configuration, the number of operational hours of diesel generator sets (gensets) decreases with an increase in the wind-farm capacity. Concurrently, emphasis has also been placed on wind penetration, un-met load, effect of hub-height on energy production and COE, excess electricity generation, percentage fuel savings and reduction in carbon emissions (relative to diesel-only situation) of different hybrid systems, cost breakdown of wind–diesel systems, COE of different hybrid systems, etc.  相似文献   

12.
In this paper, performance of a solar hybrid adsorption refrigeration (AR) system is investigated experimentally. Such a system was built and tested under the conditions at National Institute of Technology Calicut, Kerala, India. The hybrid system has been designed for heating 50 l of water from 25 to 90°C as well as cooling 10 l of water from 25 to 10°C. The experimental results demonstrate that the refrigerator has a cooling capacity of 47–78 W with a cycle coefficient of performance (COP) of 0.19 and maximum possible COP of 0.45. In exergy analysis of the system, the irreversibility and exergetic efficiency of each component of the system have been calculated. The exergy analysis reveals that the main source of irreversibility is the adsorbent bed of the AR system, emphasising that the input heat energy is not utilised efficiently due to material constraints. The exergetic efficiencies of condenser, expansion device, evaporator and adsorbent bed are found as 42.3%, 79.8%, 54.7% and 11%, respectively.  相似文献   

13.
This paper addresses the requirements of electrical energy for an isolated island of Masirah in Oman. The paper studied the possibility of using sources of renewable energy in combination with current diesel power plant on the island to meet the electrical load demand. There are two renewable energy sources used in this study, solar and wind energy. This study aimed to design and evaluate hybrid solar/wind/diesel/battery system in terms of cost and pollution. By using HOMER software, many simulation analyses have been proposed to find and optimize different technologies that contain wind turbine, solar photovoltaic, and diesel in combination with storage batteries for electrical generation. Four different hybrid power systems were proposed, diesel generators only, wind/diesel/battery, PV/diesel/battery, and PV/wind/diesel/battery. The analysis of the results shows that around 75 % could reduce the cost of energy by using PV/wind/diesel hybrid power system. Also, the greenhouse emission could be reduced by around 25 % compared with these by using diesel generators system that currently utilize in the Masirah Island. The solar/wind/diesel hybrid system is techno-economically viable for Masirah Island.  相似文献   

14.
In the present paper, the optimum design of a PV system used to operate a water pumping system was determined for Oman. The system design focused on the environmental conditions of Sohar city. The implementation and measurement of the designed system are presented to prove the effectiveness of the proposed system. The results show that the system can provide the required power at peak hours, leading to a substantial reduction in the sizing of the PV system. Consequently, the investment capital costs 2400 USD, and the cost of energy is equal to 0.309 USD/kWh. Furthermore, the results indicate that the system annual yield factor is 2024.66 kWh/kWp and that the capacity factor is 23.05 %, which is encouraging since the latter is typically 21 %. The system capital cost and the cost of energy are worth comparing to a diesel generator. A comparison is made between the proposed system and several others in the literature. The comparison indicated that the system cost of energy is promising.  相似文献   

15.
The study aimed to estimate resource use efficiency and economic losses by using stochastic frontier analysis. The data set were collected in An Giang Province of Vietnam through personal interviews with 199 rice farmers. The results revealed that returns to scale are decreasing. Rice farmers had high levels of output-oriented and input-oriented technical efficiency with the means of 91.92 and 85.39 %, respectively. The mean environmental efficiency was 82.03 %. The mean efficiency of normal inputs was 61.20 %. Among the bad inputs, pesticide and energy were the least efficient ones with the mean values of 51.39 and 45.53 %, respectively, indicating serious overuses of these inputs. As regards normal inputs, capital had the lowest efficiency score at 21.08 %, followed by seed quantity at 26.4 %. Further, the total economic losses were estimated at 8261 thousand VND (380 USD) per hectare, which is equal to the sales of about 1600 kg of rice per hectare or the efforts to increase by 20 % of output level. This study suggests that rice farmers need to contract inputs, particularly environmentally detrimental inputs to improve profits. To improve the productive efficiency, the use of ecological engineering, collective pump and cultivation of three rice crops per year are possible options.  相似文献   

16.
In this communication, experiments have been performed to check the capability of the newly formed composite desiccant material (CaCl2/floral) for the extraction of freshwater from atmospheric air. Three numbers of solar glass desiccant box type system (SGDBS) with a captured area of 0.36 m2 each, have been used. The design parameters for the water production are height of glass from desiccant bed at 0.22 m, inclination in angle as 30°, the effective thickness of glass as 3 mm and number of glazing as single. The maximum yield by the new composite desiccant material is 0.35 ml/cm3/day. The efficiency of the system SGDBS with 37 % concentration of CaCl2 is 76.44 %.  相似文献   

17.
In the present study, a natural circulation thermosyphon flat plate solar water heater has been tested at the CDFD, Hyderabad (17.37°N, 78.43°E) Andhra Pradesh, India. Experimental data were noted on a sunny day. Dynamic response of the system to variations in solar insulation was studied and analyzed. T inlet °C and T outlet °C temperatures were recorded. The performance of the system can be improved by using aluminum tape inserts into the collector fins. The objective of the present study is to evaluate the performance of flat plate collector with and without inserts (aluminum strip of 1 mm thick, 3 mm width and 203 mm length). It is expected that with the same collector with the same flow rate, higher efficiency can be obtained by inserting the tapes inside the collector copper fins (9 mm). Thus, the cost of the system can be further bringing down by enhancing the collector efficiency.  相似文献   

18.
The objective of this paper is to analyse the impacts of climate change on a pine forest stand in Central Siberia (Zotino) to assess benefits and risks for such forests in the future. We use the regional statistical climate model STARS to develop a set of climate change scenarios assuming a temperature increase by mid-century of 1, 2, 3 and 4 K. The process-based forest growth model 4C is applied to a 200-year-old pine forest to analyse impacts on carbon and water balance as well as the risk of fire under these climate change scenarios. The climate scenarios indicate precipitation increases mainly during winter and decreases during summer with increasing temperature trend. They cause rising forest productivity up to about 20 % in spite of increasing respiration losses. At the same time, the water-use efficiency increases slightly from 2.0 g C l?1 H2O under current climate to 2.1 g C l?1 H2O under 4 K scenario indicating that higher water losses from increasing evapotranspiration do not appear to lead to water limitations for the productivity at this site. The simulated actual evaporation increases by up to 32 %, but the climatic water balance decreases by up to 20 % with increasing temperature trend. In contrast, the risk of fire indicated by the Nesterov index clearly increases. Our analysis confirms increasing productivity of the boreal pine stand but also highlights increasing drought stress and risks from abiotic disturbances which could cancel out productivity gains.  相似文献   

19.
The present study investigates the energy, environment and growth nexus for a panel of South Asian countries including Bangladesh, India, Pakistan, Sri Lanka and Nepal. The simultaneous analysis of real GDP, energy consumption and CO2 emissions is conducted for the period 1980–2010. Levin panel unit root test and Im test panel unit root both indicate that all the variables are I (1). In addition, Kao’s panel Cointegration test specifies a stable long-term relationship between all these variables. Empirical findings show that a 1 % increase in energy consumption increases output by 0.81 % in long run whereas for the same increase in CO2 emission output falls by 0.17 % in long run. Panel Granger causality tests report short-run causality running from energy consumption to CO2 emissions and from CO2 emissions to GDP.  相似文献   

20.
This paper investigated the source of priority pollutants, assessment of the wastewater treatment plant, and priority pollutant removal efficiency for a single Soderberg-type primary aluminum plant.Forty-eight hour composite samples were collected from the following streams: (1) plant intake water; (2) wastewater from the primary air pollution control system (gas stream cooling water and wet ESPs); (3) secondary air pollution control system (room ventilation wet scrubber liquor); (4) paste plant briquette cooling water; and (5) final effluent after the wastewater treatment plant.Wastewater from the primary air pollution control system entered a conventional chemical coagulation (using slacked lime) — clarification plant. Clarified water from the clarifier was combined with the other three wastewater streams and flowed into a settling lagoon with a 20-h hydraulic retention time. Clarified lagoon water was finally discharged to the river.The principal source of organic compounds in the wastewater was from the primary and secondary air pollution control systems and results from the volatilization of petroleum coke and pitch in the Soderberg anode. Wastewater treatment plant removal efficiencies of greater than 85% were achieved for the majority of the organic priority pollutant species detected.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号