首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 827 毫秒
1.
Gallard H  De Laat J 《Chemosphere》2001,42(4):405-413
The rates of degradation of 1,2,4-trichlorobenzene (TCB), 2,5-dichloronitrobenzene (DCNB), diuron and isoproturon by Fe(II)/H2O2 and Fe(III)/H2O2 have been investigated in dilute aqueous solution ([Organic compound]0 approximately 1 microM, at 25.0 +/- 0.2 degrees C and pH < or = 3). Using the relative rate method with atrazine as the reference compound, and the Fe(II)/H2O2 (with an excess of Fe(II)) and Fe(III)/H2O2 systems as sources of OH radicals, the rate constants for the reaction of OH* with TCB and DCNB were determined as (6.0 +/- 0.3)10(9) and (1.1 +/- 0.2)10(9) M(-1) s(-1). Relative rates of degradation of diuron and isoproturon by Fe(II)/H2O2 were about two times smaller in the absence of dissolved oxygen than in the presence of oxygen. These data indicate that radical intermediates are reduced back to the parent compound by Fe(II) in the absence of oxygen. Oxidation experiments with Fe(III)/H2O2 showed that the rate of decomposition of atrazine markedly increased in the presence of TCB and this increase has been attributed to a regeneration of Fe(II) by oxidation reactions of intermediates (radical species and dihydroxybenzenes) by Fe(III).  相似文献   

2.
Chen WS  Juan CN  Wei KM 《Chemosphere》2005,60(8):1072-1079
Fenton's reagent, UV/H2O2 and UV/Fenton's reagent were employed to mineralize dinitrotoluene (DNT) isomers and 2,4,6-trinitrotoluene (TNT) of spent acid in toluene nitration process. The bench-scale experiments were conducted to elucidate the influence of various operating variables on the performance of removal of total organic compounds (TOC) from spent acid, including reaction temperature, concentration of ferrous ion and H2O2 dosage. It is remarkable that organic compounds were completely mineralized by Fenton oxidation, of which removal efficiency is superior to that of UV/H2O2. Nevertheless, it makes slight difference between Fenton oxidation and UV/Fenton oxidation. According to the spectra identified by gas chromatograph/mass spectrometer (GC/MS), it is proposed that oxidative degradation of DNT isomers leads to o-, m-, p-mononitrotoluene (MNT) and 1,3-dinitrobenzene respectively. Besides, the oxidation of 2,4,6-TNT gives the 1,3,5-trinitrobenzene intermediate. Apparently, Fenton oxidation is promising for purification of spent acid industrially.  相似文献   

3.
Photo-oxidation of cork manufacturing wastewater   总被引:7,自引:0,他引:7  
Several photo-activated processes have been investigated for oxidation of a cork manufacturing wastewater. A comparative activity study is made between different homogeneous (H2O2/UV-Vis and H2O2/Fe2+/UV-Vis) and heterogeneous (TiO2/UV-Vis and TiO2/H2O2/UV-Vis) systems, with degradation performances being evaluated in terms of total organic carbon (TOC) removal. Results obtained in a batch photo-reactor show that photo-catalysis with TiO2 is not suitable for this kind of wastewater while the H2O2/UV-Vis oxidation process, for which the effect of some operating conditions was investigated, allows to remove 39% of TOC after 4 h of operation (for C(H2O2)=0.59 M, pH=10 and T=35 degrees C). The combined photo-activated process, i.e., using both TiO2 and H2O2, yields an overall TOC decrease of 46% (for C(TiO2)=1.0 gl(-1)). The photo-Fenton process proved to be the most efficient, proceeds at a much higher oxidation rate and allows to achieve 66% mineralization in just 10 min of reaction time (for C(H2O2)=0.31 M, T=30 degrees C, Fe2+:H2O2=0.12 (mol) and pH=3.2).  相似文献   

4.
In this study, advanced oxidation technologies, namely Fenton Process (FP), Fenton-Like Process (FLP), ozonation (O3) and O3/H2O2 processes, were applied to synthetic wastewater containing 3-indolebutyric acid (IBA). The effectiveness of each process was investigated at different pH values, Fe(+2), Fe(+3), O3 and H2O2 concentrations with respect to the removal efficiencies for chemical oxygen demand (COD) and total organic carbon (TOC). The best removal efficiencies were seen at pH 3 and 2 mM Fe concentration in both FP and FLP, in which the optimum H2O2 concentrations were 6 mM for FP and 10 mM for FLP. Optimum process conditions were pH 12 for the O3 process, pH 9 for the O3/H2O2 process and 1:1 O3/H2O2 molar ratio. The highest COD removal efficiency was 86 percent, obtained in the O3/H2O2 process and the highest TOC removal efficiency was obtained at 77 percent in the FP.  相似文献   

5.
The photocatalytic removal kinetics of fenitrothion at a concentration of 0.5mgl(-1) in pure and natural waters were investigated in Fe(III)/H2O2/UV-Vis, Fe(III)/UV-Vis and H2O2/UV-Vis oxidation systems, with respect to decreases in fenitrothion concentrations with irradiation time using a solar simulator. Fenitrothion concentrations were determined by HPLC analysis. Furthermore, total mineralization of fenitrothion in these systems was evaluated by monitoring the decreases in DOC concentrations with solar simulator irradiation time by TOC analysis. It was shown that the degradation rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than the Fe(III)/UV-Vis and H2O2/UV-Vis systems in both pure and river waters. Consequently, the mineralization rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than in the other two systems. The high *OH generation rate measured in the Fe(III)/H2O2/UV-Vis system was the key to faster degradation of fenitrothion. Increases in the concentrations of H2O2 and Fe led to better final degradation of fenitrothion. These results suggest that the photo-Fenton reaction (Fe(III)/H2O2/UV-Vis) system is likely to be an effective method for removing fenitrothion from contaminated natural waters.  相似文献   

6.
The effects of chloride, nitrate, perchlorate and sulfate ions on the rates of the decomposition of hydrogen peroxide and the oxidation of organic compounds by the Fenton's process have been investigated. Experiments were conducted in a batch reactor, in the dark at pH < or = 3.0 and at 25 degrees C. Data obtained from Fe(II)/H2O2 experiments with [Fe(II)]0/[H2O2]0 > or = 2 mol mol(-1), showed that the rates of reaction between Fe(II) and H2O2 followed the order SO4(2-) > ClO4(-) = NO3- = Cl-. For the Fe(III)/H2O2 process, identical rates were obtained in the presence of nitrate and perchlorate, whereas the presence of sulfate or chloride markedly decreased the rates of decomposition of H2O2 by Fe(III) and the rates of oxidation of atrazine ([atrazine]0 = 0.83 microM), 4-nitrophenol ([4-NP]0 = 1 mM) and acetic acid ([acetic acid]0 = 2 mM). These inhibitory effects have been attributed to a decrease of the rate of generation of hydroxyl radicals resulting from the formation of Fe(III) complexes and the formation of less reactive (SO4(*-)) or much less reactive (Cl2(*-)) inorganic radicals.  相似文献   

7.
Paterlini WC  Nogueira RF 《Chemosphere》2005,58(8):1107-1116
The degradation of herbicides in aqueous solution by photo-Fenton process using ferrioxalate complex (FeOx) as source of Fe2+ was evaluated under blacklight irradiation. The commercial products of the herbicides tebuthiuron, diuron and 2,4-D were used. The multivariate analysis, more precisely, the response surface methodology was applied to evaluate the role of FeOx and hydrogen peroxide concentrations as variables in the degradation process, and in particular, to define the concentration ranges that result in the most efficient degradation of the herbicides. The degradation process was evaluated by the determination of the remaining total organic carbon content (TOC), by monitoring the decrease of the concentrations of the original compounds using HPLC and by the chloride ion release in the case of diuron and 2,4-D. Under optimized conditions, 20 min were sufficient to mineralize 93% of TOC from 2,4-D and 90% of diuron, including oxalate. Complete dechlorination of these compounds was achieved after 10 min reaction. It was found that the most recalcitrant herbicide is tebuthiuron, while diuron shows the highest degradability. However, under optimized conditions the initial concentration of tebuthiuron was reduced to less than 15%, while diuron and 2,4-D were reduced to around 2% after only 1 min reaction. Furthermore, it was observed that the ferrioxalate complex plays a more important role than H2O2 in the photodegradation of these herbicides in the ranges of concentrations investigated.  相似文献   

8.
Chen J  Zhu L 《Chemosphere》2006,65(7):1249-1255
Although homogeneous photo-Fenton system is a very efficient method for organic wastewater treatment, it suffers from costly pH adjustment as well as difficult separation of catalysts from aqueous in practical application. Through cation exchange reaction, hydroxyl-Fe-pillared bentonite (H-Fe-P-B) was successfully prepared as a solid catalyst for UV-Fenton to degrade non-biodegradable azo-dye Orange II. Compared with raw bentonite, the content of iron, interlamellar distance and external surface area of H-Fe-P-B increased remarkably. H-Fe-P-B had good photosensitivity and catalyst reactivity. And the catalytic activity of H-Fe-P-B for H(2)O(2) came from hydroxyl-Fe between sheets rather than Fe(3+) or Fe(2+) in tetrahedral or octahedral sheets of bentonite. In UVA-H(2)O(2) system, H(2)O(2) could destroy the azo bond of excited Orange II molecules but could not effectively mineralize it. After 120 min treatment, 83% discoloration was obtained while only 2% of TOC was removed. When H-Fe-P-B was used as catalyst, a significant degradation of Orange II was observed at the same condition as UVA-H(2)O(2) system. Almost 100% discoloration and more than 60% TOC removal of Orange II could be achieved after 120 min treatment. Because of the strong surface acidity and the electronegativity of H-Fe-P-B, the pH range of this catalyst in the Orange II discoloration could be extended up to 9.5. And this catalyst showed good stability during Orange II degradation in water in wide range of pH (3.0-9.5). These results indicated that the H-Fe-P-B was a promising catalyst for UV-Fenton system.  相似文献   

9.
The photodegradation of monuron (3-(4-chlorophenyl)-1,1-dimethylurea) in aqueous solutions under simulated solar irradiation has been conducted by different advanced oxidation processes (UV/H(2)O(2), UV/H(2)O(2)/Fe(2+), UV/H(2)O(2)/TiO(2), UV/TiO(2), dark H(2)O(2)/Fe(3+)). The degradation rates were always higher for the homogeneous catalysis in photo-Fenton reactions (UV/H(2)O(2)/Fe(2+)) compared to the heterogeneous photocatalytic systems (TiO(2)/UV and UV/H(2)O(2)/TiO(2)). Optimal concentrations of Fe(2+) and H(2)O(2) for the abatement of the herbicide in the photo-Fenton system were found to be 1 mM Fe(II) and 10 mM H(2)O(2). Several intermediary products were identified using large volume injection micro-liquid chromatography with UV detection (mu-LC-UV), mu-LC-MS and GC-MS techniques and a degradation mechanism has been proposed.  相似文献   

10.
Intention, Goal, Scope, Background The effect of chloride concentration and pH on the UV oxidation systems was examined. Phenol and methanol were used as organic substances. The treatment of these chemicals by UV oxidation using a newly developed lab scale pretest UV-Free Surface Reactor (UV-FSR) with and without Cl– addition at different pH values, is evaluated. Results of this study indicated that the Cl– concentration of the water and the chemical structure of the substances is more important than the pH of the water. There was no AOX at the beginning of the experiments, but a de-novo synthesis of AOX was observed during the batch experiments. This is caused by the high chloride content of the wastewaters. It can be supposed that OHradicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds. During the treatment, these AOX compounds which are produced from the beginning of the reaction are destroyed again. Evaluations of these experiments were done according to TOC and AOX results. Approximately 80% and 99% TOC removal efficiencies were obtained for the treatment of Phenol and Methanol-containing wastewaters, respectively. Objective In the literature, there are no relevant publications concerning the AOX formation of wastewater by wet oxidation- iron catalysed or by application of UV. For that reason, the main objectives of this study were: 1. to see the influence of chloride concentration and pH on the AOXde-novo formation with newly developed UV-Free Surface Reactor (UV-FSR), 2. to make a comparison of different AOPs, 3. to observe the effect of the chloride concentration on the TOC degradation efficiency, 4. to optimise reaction conditions. Methods In synthetic wastewaters, Methanol (CH3OH) and Phenol (C6H5 OH) are used as pollutants. The concentration of each substance was 1000 mg/l and COD values were calculated theoretically. The H2O2 addition was calculated according to the COD with a convenient stoichiometric factor (e.g. 1). During experiments, the pH was always kept constant with the addition of either 25% H2SO4 or 33% NaOH depending on the experimental conditions. Each substance was treated with the addition of 1000 mg/l Cl–, 10000 mg/l Cl– and without Cl– addition at pH 3, pH 7 and pH 10, respectively. NaCl was used as a Cl– source. Adsorbable Organic Halogenides (AOX) were determined using a TOX analyser (European Standard EN 1485 H 14, 1996). TOC measurements were carried out using an Elementar High TOC Analyzer equipped with an auto sampler. The H2O2 concentration was measured according to German Standard Methods (DIN 38409, Part 15, 1987). Results and Discussion The first step was to determine the effect of pH on the AOX formation in the process. Therefore, experiments were carried out at three different pHs: acidic (pH 3), neutral (pH 7) and basic (pH 10) conditions at a constant initial Methanol concentration of 1000 mg/l and a hydrogen peroxide concentration of 3185 mg/l (1 x stoichiometric). All results were evaluated according to applied pH. At these conditions, the amount of H2O2 (53 ml / 10 l) concentration was nearly zero after 1 hour batch treatment of Methanol. There was no AOX at the beginning of the experiments, but the AOX value increased after 6–18 min. At the end of 1 hour batch treatment this produced AOX was treated again. The maximum AOX production was obtained with the addition of 10000 mg/l Cl–, whereas there is no AOX production during the experiment when Cl– was not used. In all studies, however, TOC values decreased to almost zero after 1 hour batch treatment. After the experiments with Methanol, Phenol treatment was carried out at different pHs as a second experiment. pH was kept constant with the addition of either H2SO4 or NaOH depending on the experimental conditions. During experiments with Phenol, the colour of the water changed from colourless to a yellowish- red. After 1 hour treatment, the colour of the water was red. Therefore, these experiments were continued until the water became colourless again, and this took about 5 hours. Although there was no AOX at the beginning of the experiments, it increased after 30 min to 1 hour oxidation with the addition of 1000 mg/l Cl– and 10000 mg/l Cl–. There was no AOX production during the experiments when Cl– was not added. At the end of 5 hours of treatment, formed AOX was degraded and the TOC concentration decreased from 766 mg/l to approximately 200 mg/l. Conclusion. These experiments of this study showed that the effects of Cl– concentration of the water and the chemical structure of the substances is more than that of the pH on the AOX formation. During the batch experiments, a de-novo synthesis of AOX was observed very impressively due to the high chloride content of the wastewaters. It can be implied that OH-radicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds so that AOXde-novo is formed. At the end of the reaction times these AOX compounds are also destroyed. Recommendation and Outlook It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolourisation and removal of micropollutants. However, the most important point is the optimization of the reaction conditions for the process of concern. The AOP applied can be used, for instance, for AOX reduction and TOC removal of industrial wastewaters.  相似文献   

11.
Photodegradation of an azo dye of the textile industry   总被引:2,自引:0,他引:2  
An advanced oxidation treatment, UV/H2O2, was applied to an azo dye, Hispamin Black CA, widely used in the Peruvian textile industry. Rates of color removal and degradation of the dye have been evaluated. A strongly absorbing solution was completely decolorized after 35 min of treatment, and after 60 min an 82% reduction of the total organic carbon (TOC) was obtained. It has been found that the degradation rate increased until an optimum value, beyond which the reagent exerted an inhibitory effect. The degradation rate was also function of pH.  相似文献   

12.
Xu XR  Zhao ZY  Li XY  Gu JD 《Chemosphere》2004,55(1):73-79
Degradation of methyl tert-butyl ether (MTBE) in aqueous solution by Fenton's reagent (Fe2+ and H2O2) was investigated. Effects of reaction conditions on the oxidation efficiency of MTBE by Fenton's reagent were examined in batch experiments. Under optimum conditions, 15 mM H2O2, 2 mM Fe2+, pH 2.8 and room temperature, the initial 1 mM MTBE solution was reduced by 99% within 120 min. Results showed that MTBE was decomposed in a two-stage reaction. MTBE was first decomposed swiftly based on a Fe2+/H2O2 reaction and then decomposed somewhat less rapidly based on a Fe3+/H2O2 reaction. The detection of Fe2+ also supported the theory of the two-stage reaction for the oxidation of MTBE by Fenton's reagent. The dissolved oxygen in the solution decreased rapidly in the first stage reaction, but it showed a slow increase in the second stage with a zero-order kinetics. A reaction mechanism involving two different pathways for the decomposition of MTBE by Fenton's reagent was also proposed. Chemicals including tert-butyl formate, tert-butyl alcohol, methyl acetate and acetone were identified to be the primary intermediates and by-products of the degradation processes.  相似文献   

13.
Experimental in situ chemical peroxidation of atrazine in contaminated soil   总被引:4,自引:0,他引:4  
Mecozzi R  Di Palma L  Merli C 《Chemosphere》2006,62(9):1481-1489
Lab-scale experiments of in situ chemical oxidation (ISCO), were performed on soil contaminated with 100 mg kg(-1) of atrazine (CIET). The oxidant used was hydrogen peroxide catalysed by naturally occurring minerals or by soluble Fe(II) sulphate, added in aqueous solution. The oxidation conditions were: CIET:H2O2=1:1100, 2 PV or 3 PV reaction volume, Fe(II):H2O2=0, 1:22, 1:11. Stabilized (with KH2PO4 at a concentration of 16 g l(-1)) or non-stabilized hydrogen peroxide was used. The pH of the reagents was adjusted to pH=1 with sulphuric acid, or was not altered. Results showed that the addition of soluble Fe(II) increased the temperature of the soil slurry and the use of stabilized hydrogen peroxide resulted in a lower heat generation. The treatment reduced the COD of the soil of about 40%, pH was lowered and natural organic matter became less hydrophobic. The highest atrazine conversion (89%) was obtained in the conditions: 3 PV, Fe(II):H2O2=1:11 with stabilized hydrogen peroxide added in two steps. The stabilizer only increased H2O2 life-time significantly when soluble Fe(II) was added. Results indicate as preferential degradation pathway of atrazine in soil dechlorination instead of dealkylation.  相似文献   

14.
Chan KH  Chu W 《Chemosphere》2003,51(4):305-311
The degradation of pesticide, atrazine (ATZ), 2-chloro-4-(ethylamino)-6-(isopropylamino)-s-triazine, by Fenton's reagent (FR) was investigated as a function of reagents' concentrations and ratios in a batch reactor. The degradation of ATZ was effectively achieved by hydroxyl radicals, which were generated in the FR process. The decay rates of ATZ and the oxidation capacities of FR were found to depend on the concentrations of hydrogen peroxide and ferrous ion. The removal kinetics of ATZ are initiated by a rapid decay and then followed by a much slower one. After an extended reaction time (5-10 min), the reactions ceased because the Fe(II) and H(2)O(2) were consumed and would be deactivated in the process. A mathematical model was successfully developed to describe the two-stage reaction kinetics by using two simple but critical parameters: the initial ATZ decay rate and the final oxidation capacity of Fenton's process. In general, higher [Fe(II)] or H(2)O(2) concentrations result in faster initial decay rate and higher oxidation capacity. However, the oxidation capacity is more sensitive to the initial [Fe(II)] due to the presence of side reactions as discussed in the paper.  相似文献   

15.
Salem IA 《Chemosphere》2001,44(5):1109-1119
Copper(II) amine complexes supported on Amberlyst-15 cation resin were prepared and characterized by SEM, EDX and FTIR measurements. The kinetics of the heterogeneous oxidation of an organic dye, crystal violet, with H2O2 catalyzed by the supported catalysts was investigated in aqueous solution. The rate of reaction increases with increasing stability of the copper(II) amine complexes. The oxidation rate attained a first-order in the catalyst and the dye only at lower concentrations and second order in H2O2. A very fast formation of a peroxo-dye intermediate resulting from the interaction of H2O2 with the dye even in the presence of the catalyst was observed.  相似文献   

16.
The photo-Fenton reaction of an organophosphorus insecticide, dimethoate (O,O-dimethyl methylcarbamoylmethyl phosphorodithioate), was studied by following the identification and determination of the decomposition products and the total carbon removal rate. The reactions were performed in a batch recycle reactor, at room temperature, using UV radiation, H2O2 as oxidant, and FeCl3 x 6H2O as catalyst. The oxidation results were determined with a total organic carbon (TOC) analyzer and ion chromatography. The presence of reaction products was identified by gas chromatography-mass spectrometry (GC-MS). Apart from the sulfate, phosphate, and ammonium ions, the presence of dimethyl phosphite, N-methyl-acetamide, and formic acid was also detected. Excess of H2O2 concentration did not influence the reaction rate. The expression for the total carbon removal was assessed and the TOC removal rate constants were calculated.  相似文献   

17.
Degradation of dyes in aqueous solutions by the Fenton process   总被引:3,自引:0,他引:3  
Xu XR  Li HB  Wang WH  Gu JD 《Chemosphere》2004,57(7):595-600
Degradation of 20 different dyes in aqueous solutions by the Fenton process was performed. These dyes include 6 types: acidic, reactive, direct, cationic, disperse and vat dyes. The former four types of dyes were decolorized and their TOC values were decreased greatly, while the color and TOC removals of the latter two types were lower. The catalytic activities of four metal ions on the degradation efficiencies of Vat Blue BO, which was chosen as a model dye because of its lowest color and TOC removals, were compared in the dark and under the ultraviolet light irradiation. The catalytic ability of different metals was Fe2+>Cu2+>Mn2+>Ag+ in the dark, and the same sequence was obtained under irradiation condition with greater degradation efficiency. Furthermore, the efficiencies of three oxidation processes, including H2O2/UV, Fe2+/H2O2 and Fe2+/H2O2/UV were compared. The results showed that the oxidation by Fe2+/H2O2/UV was the strongest, and even greater than the arithmetic sum of the other two processes, which suggests the synergistic effect of ultraviolet and ferrous ions on the degradation reaction.  相似文献   

18.
Diuron (N'-[3,4-dichlorophenyl]-N,N-dimethylurea) is a herbicide belonging to the phenylurea family, widely used to destroy weeds on uncultivated surfaces. Because of its toxicity for aquatic organisms and suspicion of being carcinogenic for humans, diuron is the object of growing environmental concern. Therefore, we have developed the electro-Fenton method, an electrochemical advanced oxidation process (EAOP), to degrade diuron in aqueous medium, and we have studied the evolution of the toxicity of treated solution during the process. Indeed, the EAOPs catalytically generate hydroxyl radicals that oxidize the persistent organic pollutants, and can ultimately destroy and mineralize them. But, sometimes, relatively toxic organic metabolites are formed during the oxidation reaction. In this work, the evolution of toxicity of diuron aqueous solutions was studied at different initial concentrations, during treatment by the electro-Fenton method. Samples were collected at various electrolysis times and mineralization degrees during the treatment. The toxicity of the samples was measured using the bacteria Vibrio fischeri (Microtox) and the green alga Scenedesmus obliquus. Our results demonstrated that the toxicity of diuron aqueous solutions (concentrations=3.0-27.6 mg L(-1)) varied considerably with time. The formation and disappearance of several metabolites, having toxicity often stronger than that of the initial herbicide, were observed. To improve the efficiency of water decontamination, the electro-Fenton method should be applied during a time long enough (several hours) and at relatively high electrolysis current (I=250 mA) to reach a nearly complete mineralization of the herbicide in the aqueous medium.  相似文献   

19.
A coupled solar photo-Fenton (chemical) and biological treatment has been used to remove biorecalcitrant diuron (42 mg l(-1)) and linuron (75 mg l(-1)) herbicides from water at pilot plant scale. The chemical process has been carried out in a 82 l solar pilot plant made up by four compound parabolic collector units, and it was followed by a biological treatment performed in a 40 l sequencing batch reactor. Two Fe(II) doses (2 and 5 mg l(-1)) and sequential additions of H2O2 (20 mg l(-1)) have been used to chemically degrade the initially polluted effluent. Next, biodegradability at different oxidation states has been assessed by means of BOD/COD ratio. A reagent dose of Fe=5 mg l(-1) and H2O2=100 mg l(-1) has been required to obtain a biodegradable effluent after 100 min of irradiation time. Finally, the organic content of the photo-treated solution has been completely assimilated by a biomass consortium in the sequencing batch reactor using a total suspended solids concentration of 0.2 g l(-1) and a hydraulic retention time of 24h. Comparison between the data obtained at pilot plant scale (specially the one corresponding to the chemical step) and previously published data from a similar system performing at laboratory scale, has been carried out.  相似文献   

20.
Torrades F  Pérez M  Mansilla HD  Peral J 《Chemosphere》2003,53(10):1211-1220
Multivariate experimental design was applied to the treatment of a cellulose conventional bleaching effluent in order to evaluate the use of the Fenton reagent under solar light irradiation. The effluent was characterised by the general parameters total organic carbon (TOC), chemical oxygen demand and color, and it was analysed for chlorinated low molecular weight compounds using GC–MS. The main parameters that govern the complex reactive system: Fe(II) and H2O2 initial concentration, and temperature were simultaneously studied. Factorial experimental design allowed to assign the weight of each variable in the TOC removal after 15 min of reaction. Temperature had an important effect in the organic matter degradation, especially when the ratio of Fenton reagents was not properly chosen. Fenton reagent under solar irradiation proved to be highly effective for these types of wastewaters. A 90% TOC reduction was achieved in only 15 min of treatment. In addition, the GC–MS analysis showed the elimination of the chlorinated organic compounds initially detected in the studied bleaching effluents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号