1.
Street intersections play an important role in determining pollutant concentrations in the urban canopy – vehicle emissions often increase in the vicinity of road intersections, and the complex flow patterns that occur within the intersection determine the pollutant fluxes into adjoining streets and into the atmosphere. Operational models for urban air quality therefore need to take account of the particular characteristics of street intersections. We have performed an experimental and numerical investigation of flow and dispersion mechanisms within an urban intersection, and on the basis of our observations and results, we have developed a new operational model for pollutant exchanges in the intersection, which takes account of the non-uniformity of the pollutant fluxes entering and leaving the intersection. The intersection is created by two streets of square cross-section, crossing orthogonally; concentrations were measured by releasing a neutrally buoyant tracer gas from a line source located in one of the streets. As a general result, the numerical simulations agree well with the measurements made in the wind tunnel experiments, except for the case of ground-level concentrations, where the computed concentrations far from the axis of the line source are significantly lower than the measured values. In the first part of the study we investigate the influence of an intersection on the velocity and concentration fields in the adjoining streets; we show that the immediate influence of the intersection extends within the adjoining streets, to a distance of the order of the characteristic size of the streets. A large recirculating vortex is formed at the entrance to the cross-wind streets, and this determines the exchange of pollutants between the streets and the intersection. For some wind directions the average velocity in the street segment between intersections is the same as that which occurs in an infinitely long street with the same wind, but for other angles the average velocity in the finite-length street is significantly lower. The average concentration along a finite-length street is significantly different from that observed in an infinitely long street. In the second part of the study we investigate how the pollutant fluxes in the incoming streets are redistributed amongst the outgoing streets. An analysis of the mean streamlines shows that the flows remain relatively planar, with little variation over the vertical, and we have exploited this result to develop a simple operational model for the redistribution of pollutant fluxes within the intersection. This model has been further adapted to take account of the influence of fluctuations in wind direction over typical averaging periods. The resulting model is used in the street network model SIRANE.  相似文献   

2.
孤立与非孤立城市街道峡谷内污染物扩散   总被引:2,自引:0,他引:2  
通过求解二维不可压N-S方程、k-ε方程及污染物对流扩散方程,模拟了孤立街道峡谷与非孤立街道峡谷内的流场及交通污染物浓度场.计算结果与风洞试验结果总体趋势一致.非孤立街道峡谷内污染物壁面浓度要大于孤立街道峡谷内的壁面浓度.通过计算街道峡谷建筑屋顶高度处的垂直方向污染物通量,说明了湍流扩散是污染物扩散出街道峡谷的主要原因,其污染物通量总为正,而平均流通量可以为负.非孤立街道峡谷由于平均流流动和湍流流动的总扩散通量减少,造成污染物在街道峡谷内集聚,从而理论上解释了非孤立街道峡谷与孤立街道峡谷污染扩散的差别.  相似文献   

3.
The pollutant dispersion in a street canyon has been described in this work by using an isothermal two-dimensional lattice model coupled to the Smagorinsky sub-grid scale model. The influence of the ratio between the height of the upstream and downstream canyon walls, as well as the gap distance between them on the flow pattern, was analyzed considering the situations of ‘open country’ or isolated street canyon and ‘urban roughness’ in which the influence of an urban fabric was considered. The model determined the trajectories of a large number of passive tracer particles released in the computational domain, making it easy to visualize the flow regimes established in each case. The results agreed with the observations reported from the experiments showing a strong influence on the flow inside the canyon exerted by the upstream landscape configuration.  相似文献   

4.
A two-dimensional numerical model for simulating airflow and pollutant dispersion inside an urban street canyon was first developed using the FLUENT code, and then it was validated against a wind tunnel experiment. Then the effects of strength and position of pollutant sources on pollutant dispersion within an urban street canyon were investigated numerically. The numerical results showed that the dimensionless pollutant concentrations within the urban street canyon were independent from the source strength. The results also revealed that the pollutant distributions inside the urban street canyon with a two-lane road were influenced significantly by the positions of the two sources: 1) the closer the two sources were to the street center of the canyon, the lower the pollutant concentrations on the leeward wall and at the human respiration level in the leeward footpath became; 2) the pollutant concentrations on the windward wall and at the human respiration level in the windward footpath were not sensitive to the locations of the two sources as long as the source on the windward lane was situated outside the small recirculation zone at the bottom corner of the canyon windward wall; 3) the pollutant concentrations on the lower parts of the windward and leeward walls as well as in the two footpaths increased greatly when the two sources were moved from outside into the small recirculation zones.  相似文献   

5.
Street canyon ventilation and atmospheric turbulence   总被引:4,自引:0,他引:4  
Operational models for pollutant dispersion in urban areas require an estimate of the turbulent transfer between the street canyons and the overlying atmospheric flow. To date, the mechanisms that govern this process remain poorly understood. We have studied the mass exchange between a street canyon and the atmospheric flow above it by means of wind tunnel experiments. Fluid velocities were measured with a Particle Image Velocimetry system and passive scalar concentrations were measured using a Flame Ionisation Detector. The mass-transfer velocity between the canyon and the external flow has been estimated by measuring the cavity wash-out time. A two-box model, used to estimate the transfer velocity for varying dynamical conditions of the external flow, has been used to interpret the experimental data. This study sheds new light on the mechanisms which drive the ventilation of a street canyon and illustrates the influence of the external turbulence on the transfer process.  相似文献   

6.
This paper is concerned with the motion of air within the urban street canyon and is directed towards a deeper understanding of pollutant dispersion with respect to various simple canyon geometries and source positions. Taking into account the present days typical urban configurations, three principal flow regimes “isolated roughness flow”, “skimming flow” and “wake interference flow” (Boundary Layer Climates, 2nd edition, Methuen, London) and their corresponding pollutant dispersion characteristics are studied for various canopies aspect ratios, namely relative height (h2/h1), canyon height to width ratio (h/w) and canyon length to height ratio (l/h). A field-size canyon has been analyzed through numerical simulations using the standard k-ε turbulence closure model. It is found that the pollutant transport and diffusion is strongly dependent upon the type of flow regime inside the canyon and exchange between canyon and the above roof air. Some rules of thumbs have been established to get urban canyon geometries for efficient dispersion of pollutants.  相似文献   

7.
This paper is concerned with the motion of air within the urban street canyon and is directed towards a deeper understanding of pollutant dispersion with respect to various simple canyon geometries and source positions. Taking into account the present days typical urban configurations, three principal flow regimes “isolated roughness flow”, “skimming flow” and “wake interference flow” (Boundary Layer Climates, 2nd edition, Methuen, London) and their corresponding pollutant dispersion characteristics are studied for various canopies aspect ratios, namely relative height (h2/h1), canyon height to width ratio (h/w) and canyon length to height ratio (l/h). A field-size canyon has been analyzed through numerical simulations using the standard k-ε turbulence closure model. It is found that the pollutant transport and diffusion is strongly dependent upon the type of flow regime inside the canyon and exchange between canyon and the above roof air. Some rules of thumbs have been established to get urban canyon geometries for efficient dispersion of pollutants.  相似文献   

8.
Road traffic emissions, one of the largest source categories in megacity inventories, are highly uncertain. It is essential to develop methodologies to reduce these uncertainties to manage air quality more effectively. In this paper, we propose a methodology to estimate road traffic emission factors (EFs) from a tracer experiment and from roadside pollutants measurements. We emitted continuously during about 300 non-consecutive hours a passive tracer from a finite line source placed on one site of an urban street. At the same time, we measured continuously the resulting tracer concentrations at the other side of the street with a portable on-line gas chromatograph. We used n-propane contained in commercial liquid petroleum gas (LPG) as a passive tracer. Propane offers several advantages to traditional tracers (SF6, N2O, CFCs): low price, easily available, non-reactive, negligible global warming potential, and easy to detect with commercial on-line gas chromatographs.The tracer experiment was carried out from January to March 2007 in a busy street of Ho Chi Minh City (Vietnam). Traffic volume, weather information and pollutant concentrations were also measured at the measurement site. We used the results of the tracer experiment to calculate the dilution factors and afterwards we used these dilution factors, the traffic counts and the pollutant concentrations to estimate the EFs. The proposed method assumes that the finite emission line represents the emission produced by traffic in the full area of the street and therefore there is an error associated to this assumption. We use the Computational Fluids Dynamics (CFD) model MISKAM to calculate this error and to correct the HCMC EFs. EFs for 15 volatile organic compounds (VOCs) and NO are reported here. A comparison with available studies reveals that most of the EFs estimated here are within the range of EFs reported in other studies.  相似文献   

9.
A series of laboratory tracer migration experiments in a single rock fracture have been performed, and the breakthrough curves have been interpreted using mathematical modelling. Discrepancies were observed between the experimental data and the predictions made using a simple advection-dispersion model. The potential reasons for these discrepancies have been investigated by applying more complex models: one model incorporates channelling of flow within the fracture, the other couples dispersion and advection in the fracture with rock-matrix diffusion. It is concluded that chanelling of flow can adequately explain the observed spreading behaviour; rock-matrix diffusion is not a significant mechanism influencing transport in these experiments.  相似文献   

10.
This paper is devoted to the study of pollutant concentration distribution within urban-like geometries. By applying efficiency concepts originally developed for indoor environments, the term ventilation is used as a measure of city “breathability”. It can be applied to analyse pollutant removal within a city in operational contexts. This implies the evaluation of the bulk flow balance over the city and of the mean age of air. The influence of building packing density on flow and pollutant removal is, therefore, evaluated using those quantities. Idealized cities of regular cubical buildings were created with packing density ranging from 6.25% to 69% to represent configurations from urban sprawl to compact cities. The relative simplicity of these arrangements allowed us to apply the Computational Fluid Dynamics (CFD) flow and dispersion simulations using the standard k? turbulence model. Results show that city breathability within the urban canopy layer is strongly dependent from the building packing density. At the lower packing densities, the city responds to the wind as an agglomeration of obstacles, at larger densities (from about 44%) the city itself responds as a single obstacle. With the exception of the lowest packing density, airflow enters the array through lateral sides and leaves throughout the street top and flow out downstream. The air entering through lateral sides increases with increasing packing density.At the street top of the windward side of compact building configurations, a large upward flow is observed. This vertical transport reduces over short distance to turn into a downward flow further downstream of the building array. These findings suggest a practical way of identifying city breathability. Even though the application of these results to real scenarios require further analyses the paper illustrates a practical framework to be adopted in the assessment of the optimum neighbourhood building layout to minimize pollution levels.  相似文献   

11.
A new vegetation modeling concept for Building and Environmental Aerodynamics wind tunnel investigations was developed. The modeling concept is based on fluid dynamical similarity aspects and allows the small-scale modeling of various kinds of vegetation, e.g. field crops, shrubs, hedges, single trees and forest stands. The applicability of the modeling concept was validated in wind tunnel pollutant dispersion studies. Avenue trees in urban street canyons were modeled and their implications on traffic pollutant dispersion were investigated. The dispersion experiments proved the modeling concept to be practicable for wind tunnel studies and suggested to provide reliable concentration results. Unfavorable effects of trees on pollutant dispersion and natural ventilation in street canyons were revealed. Increased traffic pollutant concentrations were found in comparison to the tree-free reference case.  相似文献   

12.
Road traffic emission factors (EFs) are one of the main sources of uncertainties in emission inventories; it is necessary to develop methods to reduce these uncertainties to manage air quality more efficiently. Recently an alternative method has been proposed to estimate the EFs. In that work the emission factors were estimated from a long term tracer study developed in Ho Chi Minh City (HCMC) Vietnam. A passive tracer was continuously emitted from a finite line source placed in one side of an urban street canyon. Simultaneously, the resulting tracer concentrations were monitored at the other side of the street. The results of this experiment were used to calculate the dispersion factors and afterwards, these dispersion factors were used to estimate the EFs. In this paper we use the Computational Fluids Dynamics (CFD) model WinMISKAM to critically evaluate the proposed methodology.In a first step, we use the results of the tracer study to validate the CFD model. Results show that the model is able to simulate quite well the tracer dispersion in most of the cases. The model is then used to evaluate the effect of varying the source configuration and to correct the EFs. A comparison with available studies shows that the corrected EFs are within the range of the EFs reported in other studies. Finally, the CFD model is used to find a source configuration that better represents the vehicle emissions and that may be used in future studies to estimate the EFs more accurately. Results show that a 200 m line placed in the center of the street would represent very well the vehicle emissions. This work shows that it is possible to accurately estimate the EFs from tracer studies.  相似文献   

13.
Pollutant dispersion in street canyons with various configurations was simulated by discharging a large number of particles into the computation domain after developing a time-dependent wind field. Trajectory of the released particles was predicted using a Lagrangian particle model developed in an earlier study. A concentration correction scheme, based on the concept of “visibility”, was adopted for the Lagrangian particle model to correct the calculated pollutant concentration field in street canyons. The corrected concentrations compared favourably with those from wind tunnel experiments and a linear relationship between the computed concentrations and wind tunnel data were found. The developed model was then applied to four simulations to test for the suitability of the correction scheme and to study pollutant distribution in street canyons with different configurations. For those cases with obstacles presence in the computation domain, the correction scheme gives more reasonable results compared with the one without using it. Different flow regimes are observed in the street canyons, which depend on building configurations. A counter-clockwise rotating vortex may appear in a two-building case with wind flow from left to right, causing lower pollutant concentration at the leeward side of upstream building and higher concentration at the windward side of downstream building. On the other hand, a stable clockwise rotating vortex is formed in the street canyon with multiple identical buildings, resulting in poor natural ventilation in the street canyon. Moreover, particles emitted in the downstream canyon formed by buildings with large height-to-width ratios will be transported to upstream canyons.  相似文献   

14.
The results of 35 Individual SF6 tracer tests conducted in Norway during 1978 demonstrate the applicability of tracer techniques to the study of a wide variety of pollutant transport problems found in the primary aluminum industry. Tracer methods were employed to determine the efficiency of the pollutant control system over a single reduction cell under a variety of operating conditions. Two tests conducted during normal operation gave efficiencies equal to 100 ±19% and 79 ± 12%, while a test performed during the occurrence of an anode effect yielded an efficiency equal to 66 ± 22%.

Tracer investigations of flow in the wake of a smelter hall indicated that between 1 % and 11 % of secondary, roof-top emissions can become entrained in the recirculation cavity and reenter the hall through the ventilation fresh air supply. These reentry rates were observed for release heights as high as 8 m above the existing roof exhaust duct. Tracer dispersion data collected within 20 building heights of the smelter agreed very well with extrapolations of McEIroy- Pooler dispersion curves for an urban area. Dispersion curves determined from a previous wind tunnel study of flow downwind of an isolated building underestimated dispersion downwind of the vs.melter complex.

The total fluoride mass flow rate measured downwind of a smelter during wet, foggy conditions indicated that wet removal rates of fluorides are in the range 3.2 × 10?4/s to 6.4 × 10?4/s. Simulation of the source with several tracer point releases and simultaneous measurement of fluoride and tracer ground-level concentrations downwind of the smelter eliminated the need for measurements of vertical profiles of wind speed and fluoride concentration during the experiment.  相似文献   

15.
Previous studies have indicated that the EPA-HIWAY model significantly overestimates the pollutant concentrations for stable atmospheric conditions, especially under parallel wind-road orientation angles with low wind speed. This overestimation is due to the fact that the model's dispersion parameters do not properly account for the traffic-induced turbulence near roadways. In this paper, the Pasquill- Gifford dispersion curves used by the model are modified based on the recent studies that have quantified the nature of the trafficinduced turbulence and its influence on the pollutant dispersion in the near-field. The results show that the model performance is significantly improved when these new dispersion curves in conjunction with an aerodynamic drag factor, which in a rough way accounts for the change in the mean wind field due to the moving vehicles, are used in the HIWAY model.  相似文献   

16.
The mechanism of pollutant dispersion in idealized city models is investigated numerically by the introduction of a uniformly distributed pollutant source at street pedestrian level. We first study three short city forms with a single main street or two crossing streets, characterized by street length/street height ratios of L/H = 6 or 7 and a street height/street width ratio of H/W = 1, including a sharp-edged round city model, a smooth-edged round city model, and a sharp-edged square city model. For short city models with a single street and a parallel approaching wind, pollutant dilution mainly depends on the horizontal flow rate which decreases along the street. This decreasing rate is smallest for the smooth-edged round city model, which results in the lowest street concentrations. For city models with two crossing streets and the approaching wind parallel to the main street, the differences in overall city form result in different dispersion processes. For a sharp-edged round city model with two crossing streets, an approaching wind slightly non-parallel to the main street generates a lower pollutant concentration in the entire street volume. We also studied a sharp-edged round city model with one narrow street (L/H = 6; H/W = 6.7), finding that the uniformly distributed pollutants are transported from two street entries to the city centre, and are then removed out across the street roof. In contrast to the short city models we studied a single-street sharp-edged long rectangular city model (L/H = 21.7; H/W = 1) in which the horizontal flow rate remained nearly constant in a region far from the two entries. Within this region the turbulence across the street roof contributed more to the pollutant removal than vertical mean flows.  相似文献   

17.
A 3-D Eulerian-Lagrangian approach to moving vehicles is presented that takes into account the traffic-induced flow rate and turbulence. The method is applied to pollutant dispersion in an individual street canyon and a system of two street canyons forming a perpendicular intersection. The approach is based on computational fluid dynamics (CFD) calculations using a Eulerian approach for continuous phase and a Lagrangian approach for moving vehicles. The wind speed was assigned values of 4, 7 and 12 m/s. One-way and two-way traffic with different traffic rates per lane is considered. In the case of the intersection, a longitudinal wind direction was assumed. Predictions show differences in the pollutant dispersion in the case of one-way and two-way traffic.  相似文献   

18.
A Wind Tunnel Study of Gaseous Pollutants in City Street Canyons   总被引:1,自引:0,他引:1  
Steady state mean concentrations of tracer gas were measured in a 400:1 scale model of an idealized city with variable geometry placed within a wind tunnel at various orientations to the mean flow for a free stream velocity of 6.8 ft/sec. The tracer gas was released from two parallel line sources to simulate lanes of traffic in an effort to quantify the persistence of pollution as well as the mean values realized at street levels. An aerodynamically rough turbulent boundary layer of neutral thermal stratification was employed to simulate the atmosphere. Values of concentration measured in the model city were converted to prototype concentrations in ppm and compared to National Ambient Air Quality Standards. It was shown that single isolated structures may cause favorable mixing of pollution downwind but very high concentrations exist in the immediate leeward vicinity of the building. Two favorable geometries for city blocks tested were found to reduce pedestrian exposure to pollution both near heavy traffic congestion and downwind. It was concluded that the pollutant dilution was controlled by the mean flow rather than by turbulent diffusion and that the lateral spread of the plume was slight as one proceeded downwind of the line source. The combination of favorable geometry and higher dilution velocities may bring pollution levels down to existing Air Quality Standards. The body of information presented in this paper should interest city planners and air quality monitoring personnel, as well as those researchers attempting to study and model flow in city street canyons. It provides order of magnitude estimates on pedestrian and office worker exposure to pollutants under a wide range of conditions.  相似文献   

19.
A summary presentation is made of representative samples from a comprehensive experimental databank on car exhaust dispersion in urban street canyons. Physical modelling, under neutral stratification conditions, was used to provide visualisation, pollutant concentration and velocity measurements above and inside test canyons amidst surrounding urban roughness. The study extended to two different canyon aspects ratios, in combination with different roof configurations on the surrounding buildings. To serve as a reliable basis for validation and testing of urban pollution dispersion codes, special emphasis was placed in this work on data quality assurance.  相似文献   

20.
The small-scale spatial variability of air pollution observed in urban areas has created concern about the representativeness of measurements used in exposure studies. It is suspected that limit values for traffic-related pollutants may be exceeded near busy streets, although respected at urban background sites. In order to assess spatial concentration gradients and identify weather conditions that might induce air pollution episodes in urban areas, different sampling and modelling techniques were studied.Two intensive monitoring campaigns were carried out in typical street canyons in Paris during winter and summer. Steep cross-road and vertical concentration gradients were observed within the canyons, in addition to large differences between roadside and background levels. Low winds and winds parallel to the street axis were identified as the worst dispersion conditions. The correlation between the measured compounds gave an insight into their sources and fate. An empirical relationship between CO and benzene was established. Two relatively simple mathematical models and an algorithm describing vertical pollutant dispersion were used. The combination of monitoring and modelling techniques proposed in this study can be seen as a reliable and cost-effective method for assessing air quality in urban micro-environments. These findings may have important implications in designing monitoring studies to support investigation on the health effects of traffic-related air pollution.  相似文献   