首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 772 毫秒
1.
The development of a monitoring network for chemical speciation of elements of aerosol and sediment samples collected at Lake Balaton has been carried out. Sequential leaching procedures for the determination of the distribution of elements in aerosols (3 steps) and sediments (4 steps) were used. These methods were recently successfully applied to describe environmentally mobile and stable fractions of toxic metals. In aerosol matrices the partition of elements was accomplished by particle size and chemical bonding. In sediments the distribution was performed by chemical bonding. The processes are called fractionation of elements. Particular attention was paid to distinguishing between environmentally mobile and environmentally immobile fractions because these represent the two extreme modes by which the metals are bound to solid matrices. The monitoring objectives were to assess pollution effects on man and his environment and to identify any possible cause and effect relationship between pollutant concentrations and health effects. The results of dry and wet deposition rates showed that most of the toxic metals were dissolved in an aqueous phase and the wet deposition played an important role. It has been found that, while the concentration of Cd and Pb in aerosols is low (0.7 and 29 ng m(-3), respectively), environmentally mobile fractions are considerable. Based upon the data it can be concluded that the effect of the anthropogenic sources on the quality of the lake is minor. This has been the first attempt to correlate speciation results between aerosols and sediments.  相似文献   

2.
Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.  相似文献   

3.
An understanding of the scaling laws governing aerosol sampler performance leads to new options for testing aerosol samplers at small scale in a small laboratory wind tunnel. Two methods are described in this paper. The first involves an extension of what is referred to as the "conventional" approach, in which scaled aerosol sampler systems are tested in a small wind tunnel while exposed to relatively monodisperse aerosols. Such aerosols are collected by test and reference samplers respectively and assessed gravimetrically. The new studies were carried out for a modified, low flowrate version of the IOM personal inhalable aerosol sampler. It was shown that such experiments can be carried out with a very high level of repeatability, and this supported the general validity of the aerosol sampler scaling laws. The second method involves a novel testing system and protocol for evaluating the performances of aerosol samplers. Here, scaled aerosol samplers of interest are exposed to polydisperse aerosols, again in a small wind tunnel. In this instance, the sampled particles are counted and sized using a direct-reading aerodynamic particle sizer (the APS). A prototype automated aerosol sampler testing system based on this approach was built and evaluated in preliminary experiments to determine the performance of another modified version of the IOM personal inhalable aerosol sampler. The design of the new test system accounts for the complex fluid mechanical coupling that occurs near the sampler inlet involving the transition between the external flow outside the sampler and the internal airflow inside the sampler, leading in turn to uncontrolled particle losses. The problem was overcome by the insertion of porous plastic foam plugs. where the penetration characteristics are well understood, into the entries of both the test and the reference samplers. Preliminary experiments with this new system also supported the general validity of the aerosol sampler scaling laws. In addition, they demonstrated high potential that this approach may be applied in a standardised aerosol testing method and protocol.  相似文献   

4.
In the frame of assessing exposure to nanostructured particles, the aim of this work is to study the performance of a new device devoted to the real-time measurement of nanostructured aerosol: the meDiSC (Diffusion Size Classifier, Matter Engineering, Switzerland). This instrument is based on unipolar diffusion charging of particles which are then collected successively in diffusion and filtration stages. From currents measured in these stages, the instrument is capable of determining aerosol mean size and number concentration. These data were compared to reference measurements regarding monodisperse aerosols in a range from 20 to 700 nm; the relative biases were found unsatisfying. This led us to investigate the principle of the instrument. Consequently, the charging law of the diffusion charger was experimentally established, as well as the calibration curve allowing the determination of the mean size of the particles. The latter analysis was completed by a model based on diffusion theory. Our results indicate the possibility to improve the range of size measurement up to 350 nm. Measured particle size and number concentration were also used to calculate geometric surface-area concentration; the experimental data were compared to a reference calculated surface-area concentration. The results demonstrate the possibility to evaluate this parameter within acceptable uncertainty. In a second step, the meDiSC was challenged with polydisperse aerosols. It was observed that meDiSC overestimates particle size by a factor 1.7, while particle number concentrations are found within ±40% of the reference. The model applied to polydisperse aerosols indicates that polydispersity little influences particle size up to 300 nm while geometric standard deviation remains below 1.7.  相似文献   

5.
综述大气中有机胺可能的来源、健康危害及其在大气中的均相和非均相化学转化机制,阐述有机胺的反应产物对二次有机气溶胶及其对大气气溶胶的物理和化学性质的改变,此类改变增强大气气溶胶间接气候效应(如成云结核能力等)。大气中的有机胺主要通过与大气氧化剂的反应和非均相反应过程的溶解或置换进入颗粒相,而后随着湿沉降(如云滴、雾滴、雨滴等)到达地面或海面。  相似文献   

6.
Lidar measurements of temperature for the upper troposphere and lower stratosphere are commonly derived by the Raman technique. Lidar signals derived from vibrational Raman processes have been subjected to numerous simulation tests to examine their sensitivity to the presence of aerosols and ozone in the atmosphere. The influence of aerosols characteristics (wavelength dependence of aerosol extinction and particle phase function) and of ozone concentration on Raman temperature profiles is estimated. Simulations indicate large temperature deviations for post-volcanic conditions. For a Raman backscatter at 607 nm, bias is below 1 K for a total optical depth less than 9 x 10(-3) in the case of a stratospheric contamination and less than 6 x 10(-3) for a tropospheric contamination. The effect of aerosols depends on phase function and a few parameters such as altitude, optical depth and the shape of the high-altitude cloud. The wavelength dependence of aerosol extinction has some influence only for severe post-volcanic conditions (Scattering Ratio, SR >2). For a Raman backscatter at 387 nm, bias is larger and can be significant even in background aerosol conditions. Changes in the ozone density profile lead to significant Raman temperature deviations only for some specific conditions. Results suggest that both aerosol and ozone corrections are necessary to obtain an accuracy better than the 1 K requested for most atmospheric applications.  相似文献   

7.
Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM? 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO?) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions calculated from the OPC data are closely correlated with the results of the particle size-selective sampling using the CIP 10. Furthermore, the OPC data allow calculation of the thoracic fraction of workplace aerosol (not measured by sampling), which is interesting in the presence of allergenic particles like fungi spores. The results also show that the modified COP inlet adequately samples inhalable aerosol in the range of workplace particle-size distribution.  相似文献   

8.
An aerosol time-of-flight mass spectrometer (ATOFMS) was used to determine, in real time, the size and chemical composition of individual particles in the atmosphere at the remote inland site of Eskdalemuir, Scotland. A total of 51,980 particles, in the size range 0.3-7.4 microm, were detected between the 25th and 30th June 2001. Rapid changes in the number density, size and chemical composition of the atmospheric aerosol were observed. These changes are attributed to two distinct types of air mass; a polluted air mass that had passed over the British mainland before reaching Eskdalemuir, interposed between two cleaner air masses that had arrived directly from the sea. Such changes in the background aerosol could clearly be very important to studies of urban aerosols and attempts at source apportionment. The results of an objective method of data analysis are presented. Correlations were sought between the occurrence of: lithium, potassium, rubidium, caesium, beryllium, strontium, barium, ammonium, amines, nitrate, nitrite, boron, mercury, sulfate, phosphate, fluorine, chlorine, bromine, iodine and carbon (both elemental and organic hydrocarbon) in both fine (d < 2.5 microm) and coarse (d > 2.5 microm) particle fractions. Several previously unreported correlations were observed, for instance between the elements lithium, beryllium and boron. The results suggest that about 2 in 3 of all fine particles (by number rather than by mass), and 1 in 2 of all coarse particles containing carbon, consisted of elemental carbon rather than organic hydrocarbon (although a bias in the sensitivity of the ATOFMS could have affected these numbers). The ratio of the number of coarse particles containing nitrate anions to the number of particles containing chloride anions exceeded unity when the air mass had travelled over the British mainland. The analysis also illustrates that an air mass of marine origin that had travelled slowly over agricultural land can accumulate amines and ammonium.  相似文献   

9.
Interest in particle size-selective sampling for aerosols in working and ambient living environments began in the early 1900s when it became apparent that the penetration into-and deposition in-the respiratory tract of aerosol-exposed humans of inhaled particles was dependent on particle size. Coarse particles tended to be filtered out during inhalation and in the upper parts of the respiratory tract, so only progressively smaller particles penetrated down to the deep regions of the lung. Over time, following experimental studies with 'breathing' mannequins in wind tunnels and with human volunteer subjects in the laboratory, a clear picture has emerged of the physical, physiological and anatomical factors that control the extent to which particles may or may not reach certain parts of the respiratory tract. Such understanding has increasingly been the subject of discussions about aerosol standards, in particular the criteria by which exposure might be defined in relation to given classes of aerosol-related health effect-and in to turn aerosol monitoring. The ultimate goal has been to develop a set of criteria by which exposure standards are scientifically relevant to the health effects in question. This paper reviews the scientific basis for such criteria. It discusses the criteria that have already been widely discussed and so are either being applied or are on the threshold of practical application in standards. It also discusses how new advanced knowledge may allow us to extend the list of particle size-selective criteria to fractions that have not yet been widely discussed but which may be of importance in the future.  相似文献   

10.
Atmospheric aerosols were collected during the scientific expedition to Mt. Qomolangma (Everest) in May–June, 2005. The elemental concentrations of the aerosols were determined by inductively coupled plasma mass spectrometry. This yielded data for the concentration of 14 elements: Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, and Pb. The mean elemental concentrations were generally comparable with those from central Asia and the Arctic, while much higher than those from Antarctic. Size, morphology, and chemical composition of 900 individual aerosol particles were determined by scanning electron microscopy and energy-dispersive X-ray microanalysis. Based on morphology and elemental composition, the particles were clustered into eight groups: soot (8%), tar ball (3%), alumosilicates/silica (55%), calcium sulfate (16%), Ca/Mg carbonate (2%), Fe/Ti-rich particles (3%), Pb-rich particles (1%), and biological particles (12%). The sampling site, located at 6,520 m in the Himalayas, is particularly remote and located at high altitude. Nonetheless, high aerosol enrichment factors for copper, chromium, lead, nickel, vanadium, and zinc all suggest the influence of long-range transported pollution, while enrichment in calcium and the presence of alumino-silicates in individual particle analyses indicates a distinct mineral dust influence. The backward air mass trajectories showed that the northwestern part of India may contribute to the atmospheric aerosol in the central high Himalayas.  相似文献   

11.
Airborne lubricant emissions are a serious health hazard for employees in the metal working industry. The basic components of lubricants are oils and additives for adapting the properties to achieve the process demands. The oils used in lubricants are either mineral, synthetic or of biological origin. The lubricants are used as water-emulsions and also as straight oils. Extreme process conditions cause considerable amounts of aerosol and vapour emissions of lubricants into the working environment. Fibre filters are used in industrial demisters for pollution control and also for sampling purposes. Re-evaporation of separated lubricants from loaded fibre filters causes increased vapour emissions. Quantification of lubricant vapour emission was the subject of this research. An apparatus and an appropriate procedure for measuring the dynamic behaviour of evaporative losses from fibre filters were developed. The test piece of a loaded fibre filter was fixed in a sampling probe according to VDI 2066. The vapour concentration of organic compounds in downstream air was measured in real-time by using a photo-ionisation detector (PID). The PID was checked by sampling the vapour on an oleophilic adsorbent resin, solvent extraction and quantitative IR analysis and also gravimetrically. The two basic processes of filtering volatile aerosols are, on the one hand, collecting droplets on the fibres and, on the other hand, the evaporation of collected liquid. These two processes had to be separated in order to measure the increase of the vapour concentration caused by the tested fibre filter. The experiments were carried out using pure dodecane and hexadecane in order to avoid difficulties due to the unknown chemical composition of lubricant vapour. The variation of the air flow and the initial liquid mass on the filter covered the relevant range for industrial fibre demisters and for sampling methods based on collecting aerosols on fibre filters. It was found that the downstream air was saturated with lubricant vapour for a wide range of filter loads and filtration velocities. From the results obtained it can be concluded that loaded industrial filter systems emit air with saturation vapour concentration throughout their operation. Hence, vapour emissions can be estimated easily if the saturation vapour pressure and the mean relative molecular mass are known. Moreover, results obtained from measurements of filters with low loads confirm that the phase transition from liquid to vapour is influenced by the identified process parameters. This is relevant for measurement methods using fibre filters for sampling volatile aerosols. A semi-empirical model to estimate the evaporative losses for low loadings is proposed. However, further research is necessary to determine the full range of parameters that are relevant for evaporative losses from filters loaded with low masses of aerosols.  相似文献   

12.
Little is known about the physicochemical properties of beryllium aerosols associated with increased risk of beryllium sensitization and chronic beryllium disease (CBD). Such information is needed to evaluate whether airborne mass of beryllium is the appropriate metric of exposure or alternatively to provide a scientific basis for using information on particle size, surface area, and chemistry to support an improved exposure limit based on bioavailability through the inhalation and dermal routes of exposure. Thus, we used a suite of analytical techniques to characterize aerodynamically size-fractionated beryllium particles and powders that have been associated in epidemiological studies with higher prevalence of CBD. Aerosol particles were sampled from the ventilation systems of production lines for powders of beryllium metal and beryllium oxide and for ingots of copper-beryllium alloy. End product powders from the metal and oxide production lines were also collected.Particles released during production of beryllium metal were found to be complex, having heterogeneous composition, including reactive species such as fluorine. Powders from beryllium metal production were of high purity with only a minor component of beryllium oxide. Both particles and powders from oxide production were high-purity oxide. Particles released during production of copper-beryllium alloy were heterogeneous, being predominantly copper oxides. Thus, all particles and powders contain at least some beryllium in the form of beryllium oxide.These data justify efforts to thoroughly characterize beryllium aerosol properties when performing exposure assessments. The data also suggest that differences in particle chemical composition, size, number, and surface area may influence bioavailability of beryllium and contribute to risk of CBD. However, a scientific basis does not yet exist to replace mass as the current metric of exposure.  相似文献   

13.
Isocyanates constitute a group of highly reactive chemicals used on a large scale for the production of flexible polyurethane (PUR) foam. Exposure to isocyanates is known to produce irritation of the mucous membranes and the eyes. Isocyanates also have strong sensitizing properties and may cause occupational asthma. It is therefore important to monitor isocyanate emissions at workplaces. To obtain information for the improvement of isocyanate samplers and for health risk assessments of exposure, the emitted aerosol from two types of flexible PUR foam subjected to thermal degradation was characterized. Particle size distribution and toluene diisocyanate (TDI) concentration in the emitted aerosols were measured. Thermal degradation of flexible PUR foam at temperatures from 250 to 300 degrees C produced an aerosol with a geometric mean particle diameter of 30-50 nm. Between 5% and 9% of the PUR foam was emitted as TDI, and 2% to 6% of TDI monomers were found in the particle phase under the experimental conditions used. The 2,6-TDI isomer was more abundant in the gas phase than in the particle phase.  相似文献   

14.
The elemental composition and morphology of aerosols, collected from March 95 to February 96 and March 96 to August 96 respectively in the city of Chandigarh, India is determined using Energy Dispersive X-ray fluorescence and scanning electron microscopic techniques. The elemental concentration levels are found to be higher by a factor of 2-7 in the spring season as compared to the rainy season. The concentration of spherical and non-spherical (i.e. elongated) aerosols is more in the spring season and is reduced drastically in the rainy season due to the prominent wash out effect of rains. More accurate particle classification and source identification is obtained when based on combination of chemical composition and particle morphology. Possible sources identified from this analysis are soil dust, Industrial activity, Agricultural and Garbage burning, Maritime aerosols and Automobile exhaust.  相似文献   

15.
综述了近年来国内外学者对大气气溶胶中痕量金属元素的研究进展,介绍了痕量金属元素的地球化学行为,以及大气气溶胶中痕量金属的源解析方法、在环境中的循环与污染、生物有效性及对人体的健康效应。建议研发更可靠的分析方法或在线检测仪器,避免采样和样品前处理过程中痕量金属的污染和损失;建立监测网络,形成区域性的大气监测模式,更全面地分析污染来源;与监测超级站建设、空气污染流行病学设计和毒性机制研究相结合,建立更加完善的研究体系。  相似文献   

16.
Recent laboratory research indicates physiologic sampling of gas and vapor may provide more representative estimates of personal exposures than traditional methods. Modifications to the physiologic sampling pump (PSP) used in that research are described which extend its usefulness to size-selective sampling of particulates. PSPs used in previous research varied motor speed to keep sampling proportional to the subject's inhalation. This caused airflow and particle velocities through the collection device to continually change making those pumps unsuitable for sampling particulates. The modified implementation of the PSP pulls a constant airflow into and through a cyclone, then uses valves to either direct the airflow through, or divert the airflow around, the sampling filter. By using physiologic inputs to regulate the fraction of each second that air flows through the sampling filter, samples may be collected in proportion to inhalation rate. To evaluate the performance of a functional prototype 5 different sizes of monodisperse aerosols of ammonium fluorescein were generated by a vibrating orifice aerosol generator and introduced into a calm air chamber. To simulate different inhalation rates the valves of the PSP were energized using 9 different duty cycles. Efficiency curves are presented and compared to a standard respirable convention by bias mapping. The performance of the modified cyclone used in the PSP sampling head compared favorably with a commercially available cyclone of the same model, operating at a constant airflow (± 10% over almost all the size distributions of concern). The new method makes physiologic sampling of the respirable fraction of particulates feasible.  相似文献   

17.
The contributions of long range transported aerosol in East Asia to carbonaceous aerosol and particulate matter (PM) concentrations in Seoul, Korea were estimated with potential source contribution function (PSCF) calculations. Carbonaceous aerosol (organic carbon (OC) and elemental carbon (EC)), PM(2.5), and PM(10) concentrations were measured from April 2007 to March 2008 in Seoul, Korea. The PSCF and concentration weighted trajectory (CWT) receptor models were used to identify the spatial source distributions of OC, EC, PM(2.5), and coarse particles. Heavily industrialized areas in Northeast China such as Harbin and Changchun and East China including the Pearl River Delta region, the Yangtze River Delta region, and the Beijing-Tianjin region were identified as high OC, EC and PM(2.5) source areas. The conditional PSCF analysis was introduced so as to distinguish the influence of aerosol transported from heavily polluted source areas on a receptor site from that transported from relatively clean areas. The source contributions estimated using the conditional PSCF analysis account for not only the aerosol concentrations of long range transported aerosols but also the number of transport days effective on the measurement site. Based on the proposed algorithm, the condition of airmass pathways was classified into two types: one condition where airmass passed over the source region (PS) and another condition where airmass did not pass over the source region (NPS). For most of the seasons during the measurement period, 249.5-366.2% higher OC, EC, PM(2.5), and coarse particle concentrations were observed at the measurement site under PS conditions than under NPS conditions. Seasonal variations in the concentrations of OC, EC, PM(2.5), and coarse particles under PS, NPS, and background aerosol conditions were quantified. The contributions of long range transported aerosols on the OC, EC, PM(2.5), and coarse particle concentrations during several Asian dust events were also estimated. We also investigated the performance of the PSCF results obtained from combining highly time resolved measurement data and backward trajectory calculations via comparison with those from data in low resolutions. Reduced tailing effects and the larger coverage over the area of interest were observed in the PSCF results obtained from using the highly time resolved data and trajectories.  相似文献   

18.
The radiative properties of atmospheric aerosols are determined by their masses, chemical characteristics, and optical properties, such as aerosol optical depth (AOD), Åstrom;ngström parameter (α) and single scattering albedo (SSA). In particular, the aerosol optical properties determine the surface temperature perturbation that may give some information in understanding regional atmospheric radiative forcing. To understand the radiative forcing and regional source of an aerosol, the present study focused on the analysis of the aerosol optical properties based on two different observations in the spring season, during the special Asian dust storm period. The Korean Global Atmosphere Watch Observatory (KGAWO), at Anmyeon Island, and the ACE-Asia super-site, at Gosan, Jeju Island, have measured radiations and aerosols since 2000. The sites are located in the mid-west and south of the Korean peninsula, which are strongly affected by the Asian dust coming from China every spring. The aerosol optical properties, measured by ground-based sun and sky radiometers, over both sites were analyzed to gain an understanding of the radiation and climate properties.The probability distributions of the aerosol optical depths were rather narrow, with a modal value of approximately 0.38 at both sites during 2001 and 2002. The Ångström parameter frequency distributions showed two peaks at Anmyeon GAW, but only one peak at the Jeju ACE-Asia super site. One peak, around 0.63, characterizes the situation of a day having Asian dust, the second peak, around 1.13, corresponded to the relatively dust-free cases. The correlation between the aerosol optical depth and the Ångström exponents resulted in a wide range of the Ångström parameter, α, over a wide range of optical depths at Anmyeon, whereas a narrow range of α, with moderate to low values for the AOD at Jeju. Under dust free conditions the single scattering albedo (SSA) decreased with wavelength, while in the presence of Asian dust,the SSA either stayed neutral, or increased slightly with wavelength at Anmyeon, and showed higher value than Jeju. The change in the surface temperature was highly correlated with increases in the aerosol optical depth at Anmyeon to a greater extent than at Jeju.  相似文献   

19.
The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.  相似文献   

20.
In 2002 the Comité Européen Normalisation (CEN) published its document Workplace atmospheres-assessment of performance of instruments for measurement of airborne particle concentrations (EN 13205) that describes a standard protocol by which to carry out the testing and validation of personal aerosol samplers of the type widely used for occupational aerosol exposure assessment. It emerged from more than a decade of discussion and a large body of research experience involving several laboratories. The protocol that is described, however, still poses significant technical and economic challenges, not least because it involves laborious-and hence costly-procedures in large, specialized wind tunnel facilities. More recent research has identified a number of areas by which the protocol may be improved and made more accessible to testing laboratories, including a set of validated aerosol sampler scaling laws, a better understanding of the reduced role of the bluff body of the wearer on sampler performance, and the availability of new options for rapid sampler testing methods. Taking these into account, a dummy new protocol is offered for discussion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号