首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

2.
Passive sampling devices accumulate chemicals continuously from water and can provide time weighted average (TWA) concentrations of pollutants over the exposure period. Hence, they offer a number of advantages over other conventional monitoring techniques such as spot or grab sampling. The diffusive gradient in thin film (DGT) and the Chemcatcher passive samplers can be used to provide TWA concentrations of labile metals, but the approaches to their calibration differ. DGT uses diffusion coefficients of metals in the hydrogel layer, whereas Chemcatcher uses metal specific uptake rates, with both sets of values obtained under controlled laboratory conditions with constant aqueous metal concentrations. However, little is known of how such samplers respond to fluctuating concentrations. We evaluated the responsiveness of these two passive sampling devices to rapidly changing concentrations of Cd, Cu, Ni, Pb and Zn in natural freshwater, over a relatively short deployment time. Maximum metal concentrations in water were varied between 70 and 140 microg L(-1). Experiments were carried out in a tank with a rotating carousel system and filled with Meuse river water, allowing a degree of control over experimental conditions while using natural river water. Fluctuating concentrations were obtained by stepwise addition of standard solutions of the metals. The reliability and accuracy of the TWA concentrations measured by the samplers were assessed by comparison with concentrations of the metals in spot samples of water taken regularly over the deployment period. The spot samples of water were either unfiltered (total), filtered (0.45 microm) or ultrafiltered (5 kDa). Predictive speciation modelling using the visual MINTEQ programme was also undertaken. There was reasonable agreement between the TWA concentrations of Cd and Ni obtained with Chemcatcher and DGT and the total Cd and Ni concentrations measured in repeated unfiltered spot samples. For elements (i.e. Cu, Pb, Zn) that associate to a significant degree with suspended solids, colloids or dissolved organic carbon, or form complexes with large organic ligands, optimum agreement was with the filtered or ultrafiltered fractions and with the predicted inorganic and inorganic-fulvic acid associated fractions. While Chemcatcher-based TWA concentration ranges for Cu and Zn were in best agreement with the total filtered fraction, there was lack of agreement for Pb. The combined use of DGT devices with open pore (OP) and restricted pore (RP) gels allowed the labile fraction of metal associated with large organic ligands or DOC to be differentiated and quantified, since this is available to DGT OP but unable to diffuse into the DGT RP. This evaluation of the two sampling devices clearly demonstrated their ability to react reliably to transient peaks in concentration of metal pollutants in water and indicated where future efforts are needed to improve calibration data. Such samplers may prove valuable in responding to the monitoring requirements of the European Union's Water Framework Directive.  相似文献   

3.
Because of the widespread use of silver nanoparticles in commercial products, discharges of municipal wastewater may be a point source of silver in the aquatic environment. We monitored two sites in western Lake Ontario impacted by discharges from wastewater treatment plants serving the City of Toronto. Concentrations of silver were elevated in bottom sediments and suspended sediments collected at the two sites. We also deployed two types of passive samplers in the water column at the two sites, the newly developed Carbon Nanotube Integrative Samplers for monitoring “CNIS-labile” silver and Diffusive Gradient in Thin Film samplers for monitoring “DGT-labile” silver. Results from these passive samplers indicated that the concentrations of silver at the two sites were either below detection limits or were in the ng/L range. In laboratory experiments where the sediments were re-suspended in Milli-Q water, a small proportion of the silver (i.e., <?25%) was labile and partitioned as colloidal or dissolved silver into the liquid phase after agitation. Nanoparticles tentatively identified as silver nanoparticles were detected by single-particle ICP-MS in suspension after agitation of both suspended and bottom sediments. Therefore, there is a need to assess whether silver species, including silver nanoparticles are transported from wastewater treatment plants into sediments in the aquatic environment. This study is unique in focusing on the in situ distribution of silver in natural waters and in sediments that are potentially impacted by urban sources of nanoparticles.  相似文献   

4.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

5.
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7-28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.  相似文献   

6.
The ability to sample in situ natural environmental processes has proven to be challenging when working with redox-sensitive contaminates in saturated sediments in wetland systems, especially within the rhizosphere, where sharp redox gradients are common. Many traditional approaches are invasive and disturb natural sediment chemistry. Through laboratory and field studies, the work presented in this study demonstrates a novel semipermanent dialysis sampler that allows for long-term, anaerobic monitoring of shallow sediments. Dialysis samplers were deployed and tested for over 1 year while being exposed to extremes in climate. These newly designed devices produce statistically reproducible data and capture sensitive redox trends. Results from the newly designed samplers were compared to conventional samplers. Initially, both the new and old designs yielded statistically similar data, but these data diverged over a period of months. The new devices are less invasive, so data gathered from these devices are more likely to be a closer representation of true conditions in the subsurface. By giving reliable data from a consistent location in space, these new samplers represent a significant step forward in capturing spatial and temporal variability in wetland redox chemistry during long-term monitoring.  相似文献   

7.
While polyurethane foam (PUF) disk passive air samplers are employed increasingly to monitor persistent organic pollutants in indoor air, they essentially sample only the vapour phase. As a previous investigation of the vapour : particle phase partitioning of hexabromocyclododecanes HBCDs in (outdoor) air reported them to be present largely in the particulate phase, we monitored three offices using active air samplers. In each, approximately 65% of HBCDs were present in the vapour phase, suggesting PUF disk passive samplers are suitable for monitoring HBCDs in indoor air. Concentrations in the three offices (239-359 pg Sigma HBCD m(-3)) exceed substantially those reported in outdoor air from the United States (2.1-11 pg Sigma HBCD m(-3)), but are in line with outdoor air from Stockholm. The relative abundance of the three principal diastereomers in office air was closer to that found in technical HBCD formulations (i.e. predominantly gamma-HBCD) than in most US outdoor air samples. Time integrated air concentrations of alpha-, beta-, and gamma-HBCD were obtained for an office using a low volume sampler operated over a 50 d period alongside PUF disk samplers. This calibration exercise yielded the following passive air sampling rates for both a fully- and part-sheltered PUF disk sampler design: for alpha-, beta-, and gamma-HBCD, 0.87, 0.89, and 0.91 m3 d(-1) respectively (fully-sheltered) and 1.38, 1.54, and 1.55 m3 d(-1) respectively (part-sheltered). Deployment of the part-sheltered configuration yielded concentrations approximately 35% lower than those obtained using a high volume sampler, consistent with PUF disk samplers measuring primarily the vapour phase.  相似文献   

8.
江苏省流域水环境综合管理监控预警体系构建   总被引:1,自引:0,他引:1       下载免费PDF全文
以水生态功能分区为基础,构建江苏省流域水环境综合管理监控预警体系,包括基于水环境容量的污染物总量控制体系、基于主要水污染物的总量减排监控体系、基于水生态系统安全的监测与评估体系和基于水环境风险的监控预警体系,使江苏省水环境管理从单一的水质管理向流域综合管理转变,从单纯的化学污染控制向水生态系统保护转变,从目标总量管理向...  相似文献   

9.
Agricultural production systems are recognised as a major source of atmospheric ammonia. Deposition of ammonia and ammonium may contribute to undesired changes in oligotrophic ecosystems. The continuous measurement of atmospheric ammonia requires expensive and sophisticated techniques and is performed only in a very restrict number of ambient air stations in Europe. Therefore, the application of passive samplers, which have the advantage of being easy to handle and cost-efficient, is useful. In the past the comparability of different passive samplers must be considered as rather scarce. In a joint European project under the leadership of the GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg, in 1997 a comparison of different passive ammonia monitoring methods was carried out in a prealpine rural site near Garmisch-Partenkirchen. It was considered valuable to include not only well established systems but also methods still being developed. For the comparative test ten working groups with different methods took part. A wet annular denuder system, which has been developed by the Netherlands Energy Research Foundation for on-line measurement of atmospheric ammonia, served as reference of passive methods. The experiment, which started in June and finished in December, showed that most of the passive samplers fulfil the requirements and can be recommended for further measurements. Additional measurements of meteorological parameters were performed to check the influences of different weather conditions on passive sampling.  相似文献   

10.
Assessment of population exposure to VOC in ambient atmospheres is receiving heightened interest as the adverse health effects of chronic exposure to certain of these compounds are identified. Active (pumped) and passive samplers are the most commonly used devices for this type of monitoring. It has been shown, however, that these devices, along with all other preconcentration techniques, are susceptible to ozone interference. It is demonstrated that this interference occurs even at low ozone concentrations and that it may result in the under-estimation of population exposure. A convenient and effective ozone scrubbing method is identified and successfully applied and validated for both active and passive samplers for a range of VOC.  相似文献   

11.
Atmospheric BTEX [benzene, toluene, ethylbenzene, o-xylene and (m + p)-xylene] concentrations have been determined in the Naples metropolitan area (NMA) and in two suburban areas located on the north within about 25 km, during 2006. The pollutants were collected by passive samplers (24-h samplings), and analysed by GC-MS. In all the areas analysed the average atmospheric benzene concentrations were higher than the limit value fixed by the European Union for 2010 and in NMA the average concentration (9.8 microg m(-3)) also exceeded the limit fixed for 2006. High linear correlation coefficients between the average daily concentrations of the different BTEX are indicative of a single major source, most likely the vehicular traffic. The temporal and spatial distribution of BTEX relative concentrations suggest that massive emissions in NMA negatively affect the quality of the air in northern suburban areas, prevalently during the hottest months of the year, probably due to transport by local seasonal winds. The ratios between BTEX daily concentrations showed a clear dependence on the intensity of solar actinic flow, indicating a major role of photochemical processes in the air cleaning from these volatile organic pollutants.  相似文献   

12.
被动采样监测环境空气中SO 2和NO 2   总被引:1,自引:0,他引:1  
用自主研制的采样管开展环境空气中SO2和NO2的被动采样监测.结果表明,被动采样监测结果与自动监测结果高度相关,经回归方程修正后,两者的结果没有显著性差异,被动采样的采样和分析产生的误差得以消除.  相似文献   

13.
Analysis of short-chain chlorinated paraffins: a discussion paper   总被引:1,自引:0,他引:1  
Short-chain chlorinated paraffins are a class of organic compounds widely used in many industrial applications, extensively diffused into the environment, persistent, bioaccumulative, and toxic towards aquatic organisms. However, their study and monitoring in the environment are still limited. Because of the enormous number of positional isomers that characterise their mixtures, the analysis of this class of pollutants is very difficult to perform. Beside this, the lack of certified reference materials poses a problem for the assessment of the quality assurance/quality control of any analytical procedure. At present, the scientific community does not agree on any analytical reference method, although the monitoring of short-chain chlorinated paraffins has already started in order to comply with the Water Framework Directive of the European Union on water quality. In this paper the regulatory framework, in which chlorinated paraffins are included, and the status concerning their determination are summarized. The main analytical difficulties still existing are discussed, and the definition of a method-defined parameter as well as the development of a standardised method are suggested as a way to obtain comparable monitoring data.  相似文献   

14.
Denmark has a long tradition of monitoring the aquatic environment. Previous monitoring has mainly focused on loss of nutrients and subsequent impacts on the biological structure in lakes and coastal areas. However, as part of the third Action Plan for the Aquatic Environment more emphasis has been put on stream ecology. The present paper describes background, strategy and content of the new NOVANA stream programme, which will run for the period 2004–2009. The new programme will encompass more than 800 stations covering all stream types in Denmark and monitoring will include three biological quality elements (macrophytes, macroinvertebrates and fish) as well as physico-chemical features and hydromorphological elements. In addition, the new programme integrates monitoring of elements both in the stream itself and in the riparian zone. Compliance with important European Commission Directives such as the Water Framework Directive and the Habitat Directive is discussed.  相似文献   

15.
Long-term phenol, cresols and BTEX monitoring in urban air   总被引:1,自引:0,他引:1  
This paper reports the results of a long-term monitoring of benzene, toluene, ethylbenzene, xylenes (BTEX), phenol and cresols in the air of Padua during a wide period of the year 2007 using two radial passive samplers (Radiello system) equipped with BTEX- and phenol-specific cartridges. Two sites were monitored, one in the industrial area and one close to the town centre. Relevant pollution episodes have been observed during both the winter and summer periods. Benzene, together with toluene, ethylbenzene and xylenes showed their maximum concentrations during the winter season, but the secondary pollutant phenol was higher than benzene for a large period of the year when the meteorological conditions blocked the pollutants in the lower layers of the atmosphere and solar radiation increased the benzene photo-oxidation process.  相似文献   

16.
大气中痕量持久性有机污染物年均值的测定   总被引:4,自引:1,他引:3       下载免费PDF全文
采用以XAD-2树脂为吸附介质的大气被动采样器,在四川卧龙自然保护区设置6个采样点,进行了为期2年(2005年-2007年)的环境大气样品采集。用气相色谱-高分辨质谱方法对HCB,HCHs,DDTs和PCBs测定。结果表明,平行样品的重现性良好,平均相对偏差为9%。POPs检测下限的范围为1.0pg/m^3-5.9pg/m^3。2年的年均值数据表现出较好的一致性和规律性。以XAD-2树脂为吸附介质的大气被动采样器能够便利地采集进而测定半年或一年污染物的平均浓度,可以经济、有效地获得大气中痕量POPs的年均值。ρ(α—HCH)/ρ(γ-HCH)从成都到卧龙的上升的趋势反映的是传输过程中HCH的降解;而卧龙地区跨年度数据所反映出的ρ(α—HCH)/ρ(γ-HCH)下降趋势,可以归因于林丹的使用。  相似文献   

17.
This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.  相似文献   

18.
Anticipating the European Water Framework Directive (2000/60/EC), the Italian Government issued Legislative Decree n.152/99 which sets out rules for classifying the environmental status of national water bodies in order to achieve specific qualitative objectives by 2016. The most recent European Groundwater Directive (2006/118/EC), which was only recognized by Italy in early 2009 (Legislative Decree 30/09), requires such resources to be characterized from a qualitative standpoint and the risk of their being polluted by individual pollutants or groups of pollutants to be evaluated. This paper reports a simple methodology, based on easy-to-apply rules, for the rapid classification of groundwater, and the results of its application to the shallow aquifer of the plain of Tavoliere delle Puglie located in south Italy. Data collected during well-water monitoring campaigns carried out from 2002 to 2003 made it possible to assess the environmental status of the Tavoliere which, unfortunately, was found to be characterized by ??significant anthropic pressures on quality and/or quantity of groundwater and necessitating specific improvement actions??.  相似文献   

19.
A new sampling system has been developed for the measurement of time-averaged concentrations of organic micropollutants in aquatic environments. The system is based on the diffusion of targeted organic compounds through a rate-limiting membrane and the subsequent accumulation of these species in a bound, hydrophobic, solid-phase material. It provides a novel and robust solution to the problem of monitoring in situations where large temporal fluctuations in pollutant levels may occur. Accumulation rates are regulated by choice of diffusion-limiting membrane and bound solid-phase material and have been found to be dependent on the physico-chemical properties of individual target analytes. Two separate prototype systems are described: one suitable for the sampling of non-polar organic species with log octanol/water partition coefficient (log P) values greater than 4, the other for more polar species with log P values between 2 and 4. Both systems use the same solid-phase material (47 mm C18 Empore disk) as a receiving phase but are fitted with different rate-limiting membrane materials (polysulfone for the polar and polyethylene for the non-polar analytes). The two systems complement each other and together can be used for sampling a wider range of organic analytes than generally possible using current passive sampling techniques. Calibration data are presented for both devices. In each case, linear uptake kinetics were sustained, under constant conditions, for deployment periods of between 1 and 9 days. The effects of water temperature and turbulence on sampling rates have been quantitatively assessed. The performance of the system was further investigated by means of field exposures for one and two weeks in marine environments where calibrated samplers were used to determine the time-averaged concentrations of the polar biocides diuron and irgarol 1051. The quantitative results obtained using the passive sampler were compared with those obtained using spot sampling.  相似文献   

20.
Thirty two polychlorinated biphenyl congeners (PCBs), hexachlorobenzene (HCB) and pentachlorobenzene (PeCB) were analysed in passive sampler extracts from surface water-exposed semipermeable membrane devices (SPMDs) and in bed sediment samples from a small urban watercourse, the River Alna (Oslo, Norway). Performance reference compound-corrected data from the passive samplers deployed at three sites along the river were used to track PCB contamination in the overlying water. SPMDs were able to detect an increase in dissolved PCB concentrations at the site furthest downstream that was corroborated by bed sediment concentrations. In comparison, no major increase in concentration of HCB, PeCB or PAHs could be observed. Comparison of passive sampling-based overlying water concentrations with total concentrations measured in bed sediments supports the possibility of further PCB sources upstream of the study area. Diagnostic PAH ratios (from SPMDs) and PCB congener pattern (from sediments) were used in an attempt to identify possible contaminant sources to the Alna River. Selected PAH diagnostic ratios support a multiple emission source scenario and demonstrate the complexity of identifying specific sources of these compounds to surface waters. PCB congener patterns in sediments from all three sites tend to indicate a source of highly chlorinated PCBs (of the Archlor 1260 type) and either a source of lower chlorinated PCBs or the less-likely occurrence of dechlorination in sediment. Information collected during the present screening study also confirms the Alna River as a continuous source of PCBs to the Oslofjord.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号