首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A study of the equivalence to the reference methods of the Radiello samplers for ozone (O(3)) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO(2)) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O(3), the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 microg m(-3), the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 microg m(-3) of the 2nd European Daughter Directive was examined. In the case of NO(2), the equivalence to the annual limit value of the 1st European Daughter Directive (40 microg m(-3)) was considered. Results show that the radial sampler for O(3) fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O(3) diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO(2), all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO(2), respectively.  相似文献   

2.
A combined NO2-SO2 Radiello radial-type diffusive sampler was validated under controlled laboratory conditions and compared with NO2-SO2 results of 3 other type of samplers in a field comparison at two locations Ghent-Mariakerke and Borgerhout in Flanders. Laboratory exposures at different temperatures (-5, 10 and 30 degrees C) and relative humidities (0, 50 and 80% RH) in combination with varying concentration levels and exposure times were carried out, with a focus on extreme conditions. Concentration level and exposure time were changed together following suppliers linear working range of samplers and assuring absolute amounts of compounds on the sampler corresponding to those of environmental levels. The average uptake rate for NO2 for 24 hour exposures at 10 degrees C and 50% RH and tested concentration levels (+/-73, 146 and 293 ppb NO2) was 0.076 +/- 0.011 ng ppb(-1) min(-1). Uptake rates during all experiments were lower than the uptake rate given in the instruction manual of the sampler. A significant effect of temperature and relative humidity on NO2 uptake rate was observed. The temperature effect from 10 to 30 degrees C corresponds to the temperature effect given by the supplier of the samplers. High relative humidity (70 to 80%) caused a strong non-reproducible decrease of uptake rate for NO2 at 24 hour experiments but this effect was not observed at longer exposures except for the tests at -5 degrees C. At the tested temperature below zero in combination with high relative humidity the sampler showed anomalous behaviour for NO2. The possible effect of concentration level and exposure time for NO2 needs further research. The average uptake rate for SO2 calculated from all exposures is 0.478 +/- 0.075 ng of sulfate ion each ppb min of SO2 and accords to suppliers uptake rate. No clear effects of temperature, relative humidity or concentration level/exposure time on the uptake rate for SO2 were found, partly due to the large scatter of results. Although NO2 accuracy of Radiello samplers was better during field campaigns than during laboratory validation, IVL and OGAWA samplers gave better results for NO2. In the field, IVL samplers showed best agreement with the continuous analyzers for both NO2 and SO2.  相似文献   

3.
This paper presents the results of a feasability study for the preparation and certification of reference materials (RMs) for nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)) in diffusive samplers. RMs for NO(2) were prepared by exposure to gas mixtures in a chamber while the RMs for SO(2) were prepared by liquid spiking. Certification of RMs for NO(2) was found feasible with a certified uncertainty of 5.8% and a proposed shelf life of 5 years. The uncertainty was calculated with contribution from the homogeneity of preparation, stability and transport of the CRMs and from an external verification of the certified value. To reach 5.8% of uncertainty, the contribution of the differences between the results of analysis by ion chromatography and colorimetry must be eliminated. It is proposed to solve this by pre-extracting the samplers with water before analysis. The results of this study indicate that the samplers are stable for at least two years before and after exposure when stored in a refrigerator. By contrast, the certification of RMs for SO(2) was found to not be feasible due to instability problems. This instability was attributed to reaction of sulfate on the walls of the samplers. Alternatively, the preparation of RMs by simultaneous exposure to SO(2) and NO(2) has been tested. Satisfying homogeneities has been reached both for NO(2) and SO(2).  相似文献   

4.
The influence of environmental parameters on the uptake rate of the nitrogen dioxide (NO(2)) Palmes diffusive sampler was investigated. The main factors affecting the uptake rate were found to be wind speed, the preponderant factor, followed by relative humidity and temperature. The NO(2) concentration and exposure time, as well as the interactions among the factors were not found to have a significant influence on the uptake rate of the Palmes sampler. As a result, a model able to predict the uptake rate of the Palmes sampler was established. In addition, by using the model-predicted uptake rate, the agreement between chemiluminescence and the Palmes sampler during the field tests was improved. The NO(2) Palmes diffusive sampler was shown to comply with the requirement on accuracy defined by the European Directive for the indicative methods of measurements.  相似文献   

5.
This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 microg/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R (2) > 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (approximately 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.  相似文献   

6.
In the framework of new European directives in the field of ambient air quality assessment specific requirements for measurement methods for benzene will be defined and have to be met in the future. In a residential area in the vicinity of a cokery a comprehensive monitoring programme for BTX compounds (benzene, toluene, xylenes) was carried out with diffusive samplers. Measurement results from 20 sites show a distinct spatial distribution of benzene concentrations which is caused by the emissions of the plant. Comparisons with two pumped measurement methods reveal excellent agreement in the case of benzene. An assessment of measurement uncertainty for the diffusive method is presented in terms of standard deviations from parallel measurements (precision) and by comparison with a reference method according to national and international standards. Data quality objectives required by an upcoming European directive for benzene can be met by diffusive sampling.  相似文献   

7.
Tube type samplers with two different adsorbents, Chromosorb 106 and Tenax TA, were evaluated by laboratory experiments and field tests for simultaneous diffusive sampling of alpha-pinene, beta-pinene and delta 3-carene and subsequent thermal desorption-gas chromatographic analysis. No statistically significant effects of exposure time, concentrations of monoterpenes or relative humidity were found for samplers with Chromosorb 106 when running a factorial design, with the exception of the adsorption of delta 3-carene, for which some weak effects were noted. Samplers with Tenax TA were affected by the sampling time as well as the concentration for all terpenes, with a strong interaction effect between these two factors. The terpenes showed good storage stability on both adsorbents. No effect of back-diffusion was noted when using Chromosorb 106, while Tenax TA showed some back-diffusion effects. The uptake rates, in ml min-1, for the terpenes on Chromosorb 106 were 0.36 for alpha-pinene, 0.36 for beta-pinene and 0.40 for delta 3-carene. The corresponding average values on Tenax TA were 0.30 for alpha-pinene, 0.32 for beta-pinene and 0.38 for delta 3-carene. The field validation proved that diffusive sampling on Chromosorb 106 agreed well with pumped sampling on charcoal for stationary samples, while the personal samples indicated a discrepancy of 25% between Chromosorb 106 and charcoal samples. Tenax TA generally gave lower results than Chromosorb 106 in all field samples. Samplers packed with Chromosorb 106 could be used to monitor terpene levels in workplaces such as sawmills. The major advantages with this method are the sampling procedure, which is simple to perform compared to other techniques, the easily automated analysis procedure and the possibility to reuse the samplers.  相似文献   

8.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

9.
A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.  相似文献   

10.
Passive sampling devices accumulate chemicals continuously from water and can provide time weighted average (TWA) concentrations of pollutants over the exposure period. Hence, they offer a number of advantages over other conventional monitoring techniques such as spot or grab sampling. The diffusive gradient in thin film (DGT) and the Chemcatcher passive samplers can be used to provide TWA concentrations of labile metals, but the approaches to their calibration differ. DGT uses diffusion coefficients of metals in the hydrogel layer, whereas Chemcatcher uses metal specific uptake rates, with both sets of values obtained under controlled laboratory conditions with constant aqueous metal concentrations. However, little is known of how such samplers respond to fluctuating concentrations. We evaluated the responsiveness of these two passive sampling devices to rapidly changing concentrations of Cd, Cu, Ni, Pb and Zn in natural freshwater, over a relatively short deployment time. Maximum metal concentrations in water were varied between 70 and 140 microg L(-1). Experiments were carried out in a tank with a rotating carousel system and filled with Meuse river water, allowing a degree of control over experimental conditions while using natural river water. Fluctuating concentrations were obtained by stepwise addition of standard solutions of the metals. The reliability and accuracy of the TWA concentrations measured by the samplers were assessed by comparison with concentrations of the metals in spot samples of water taken regularly over the deployment period. The spot samples of water were either unfiltered (total), filtered (0.45 microm) or ultrafiltered (5 kDa). Predictive speciation modelling using the visual MINTEQ programme was also undertaken. There was reasonable agreement between the TWA concentrations of Cd and Ni obtained with Chemcatcher and DGT and the total Cd and Ni concentrations measured in repeated unfiltered spot samples. For elements (i.e. Cu, Pb, Zn) that associate to a significant degree with suspended solids, colloids or dissolved organic carbon, or form complexes with large organic ligands, optimum agreement was with the filtered or ultrafiltered fractions and with the predicted inorganic and inorganic-fulvic acid associated fractions. While Chemcatcher-based TWA concentration ranges for Cu and Zn were in best agreement with the total filtered fraction, there was lack of agreement for Pb. The combined use of DGT devices with open pore (OP) and restricted pore (RP) gels allowed the labile fraction of metal associated with large organic ligands or DOC to be differentiated and quantified, since this is available to DGT OP but unable to diffuse into the DGT RP. This evaluation of the two sampling devices clearly demonstrated their ability to react reliably to transient peaks in concentration of metal pollutants in water and indicated where future efforts are needed to improve calibration data. Such samplers may prove valuable in responding to the monitoring requirements of the European Union's Water Framework Directive.  相似文献   

11.
Two studies at three sites in the UK provided confirmation that systematic positive bias in NO2 diffusion tube measurement occurred because of changes to "within-tube" chemistry, rather than eddy diffusion at the mouth of the tube. In the first study in Cambridge, UK, sampler overestimation for 1 and 2 week exposures was compared to corresponding time-averaged monitor measurements (NO-NO2-NOx, O3) and weather variables. Noninearity between sampler and monitor NO2 measurements was interpreted in terms of spatial and temporal variations in relative and absolute availability of NO, NO2 and O3 at the site. A maximum overestimation occurred for an exposure mean NO2/NOx approximately 0.5. The separate contributions of reduced NO2 photolysis and eddy diffusion were compared in Study II using samplers of two materials, acrylic and quartz, and of different lengths (40, 55, 71 and 120 mm) at three sites: Norwich background, Cambridge intermediate, London kerbside. For compared sites, NO2 measured by acrylic samplers was significantly higher than for equivalent quartz samplers. For quartz samplers [NO2]mean was only just above the monitor at Norwich and London; sampler/monitor NO2 = 1.04 (P = 0.59) and 1.01(P = 0.76), respectively. For acrylic samplers the order of [NO2]mean was 40 mm > 120 mm > 71 mm > or = 55 mm. Excepting 40 mm samplers, this accords with a chemical bias where co-diffusing NO and 03 molecules in longer tubes have more time to react to form excess NO2. Bias in 40 mm samplers is discussed. Eddy diffusion is negligible for standard samplers because [NO2]mean was equivalent for 55 mm and 71 mm acrylic samplers and close to monitor NO2 for 71 mm quartz tubes. Both studies showed that sampler accuracy was dependent on location. Significantly, overestimation was greatest (approximately 3-4 ppb) where the NO2 annual mean was approximately 20 ppb, close to the UK and EU air quality standard of 21 ppb.  相似文献   

12.
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20%, H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as approximately 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P < or = 0.001). Reasons for the difference are discussed.  相似文献   

13.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   

14.
Assessment of trace element contents in soils is required in Germany (and other countries) before sewage sludge application on arable soils. The reliability of measured element contents is affected by measurement uncertainty, which consists of components due to (1) sampling, (2) laboratory repeatability (intra-lab) and (3) reproducibility (between-lab). A complete characterization of average trace element contents in field soils should encompass the uncertainty of all these components. The objectives of this study were to elucidate the magnitude and relative proportions of uncertainty components for the metals As, B, Cd, Co, Cr, Mo, Ni, Pb, Tl and Zn in three arable fields of different field-scale heterogeneity, based on a collaborative trial (CT) (standardized procedure) and two sampling proficiency tests (PT) (individual sampling procedure). To obtain reference values and estimates of field-scale heterogeneity, a detailed reference sampling was conducted. Components of uncertainty (sampling person, sampling repetition, laboratory) were estimated by variance component analysis, whereas reproducibility uncertainty was estimated using results from numerous laboratory proficiency tests. Sampling uncertainty in general increased with field-scale heterogeneity; however, total uncertainty was mostly dominated by (total) laboratory uncertainty. Reproducibility analytical uncertainty was on average by a factor of about 3 higher than repeatability uncertainty. Therefore, analysis within one single laboratory and, for heterogeneous fields, a reduction of sampling uncertainty (for instance by larger numbers of sample increments and/or a denser coverage of the field area) would be most effective to reduce total uncertainty. On the other hand, when only intra-laboratory analytical uncertainty was considered, total sampling uncertainty on average prevailed over analytical uncertainty by a factor of 2. Both sampling and laboratory repeatability uncertainty were highly variable depending not only on the analyte but also on the field and the sampling trial. Comparison of PT with CT sampling suggests that standardization of sampling protocols reduces sampling uncertainty, especially for fields of low heterogeneity.  相似文献   

15.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

16.
Hereafter, an assessment of the ability of the chemiluminescence method to measure ambient NO2 with an accuracy within 15%, as requested by the data quality objective of European directive 1999/30/CE, is presented. In general, uncertainty is evaluated using the response to reference materials or by means of inter-comparisons used to determine some statistics like repeatability, reproducibility and calibration bias. These are incomplete approaches and the method of the Guide to the Expression of Uncertainty in Measurement, advised by the Directive, should be preferred. In fact, even if it requires a large data set, it allows the relative influence of all possible sources of uncertainty to be studied. The extent of NO2 uncertainty is mainly dependent on the level of NO. It is decreased by NOx and the correlation between NOx and NO. Furthermore, the uncertainty budget reveals that the contribution of accuracy of calibration standard, linearity, converter efficiency and drift of the analyser between calibration checks to the overall uncertainty is less important than the contribution of interference, mainly humidity and PAN in rural areas. The relative expanded uncertainty of the NO2 hourly average exceeds 30% for NO2 concentrations lower than 40 microg m(-3). Nevertheless, the data quality objective of 15% is reached for 200 microg m(-3), the hourly limit value of the European directive. On the contrary, at the limit value on the annual average, 40 microg m(-3), the data quality objective is not met if NO is higher than 100 microg m(-3). However, the data quality objective could be reached by correcting the measurements with the bias due to interference.  相似文献   

17.
The aim of this study was to quantify personal exposure and indoor levels of the suspected or known carcinogenic compounds 1,3-butadiene, benzene, formaldehyde and acetaldehyde in a small Swedish town where wood burning for space heating is common. Subjects (wood burners, n = 14), living in homes with daily use of wood-burning appliances were compared with referents (n = 10) living in the same residential area. Personal exposure and stationary measurements indoors and at an ambient site were performed with diffusive samplers for 24 h. In addition, 7 day measurements of 1,3-butadiene and benzene were performed inside and outside the homes. Wood burners had significantly higher median personal exposure to 1,3-butadiene (0.18 microg m(-3)) compared with referents (0.12 microg m(-3)), which was also reflected in the indoor levels. Significantly higher indoor levels of benzene were found in the wood-burning homes (3.0 microg m(-3)) compared with the reference homes (1.5 microg m(-3)). With regard to aldehydes, median levels obtained from personal and indoor measurements were similar although the four most extreme acetaldehyde levels were all found in wood burners. High correlations were found between personal and indoor levels for all substances (r(s) > 0.8). In a linear regression model, type of wood-burning appliance, burning time and number of wood replenishments were significant factors for indoor levels of 1,3-butadiene. Domestic wood burning seems to increase personal exposure to 1,3-butadiene as well as indoor levels of 1,3-butadiene and benzene and possibly also acetaldehyde. The cancer risk from these compounds at exposure to wood smoke is, however, estimated to be low in developed countries.  相似文献   

18.
On February 26, 1988, the U.S. Environmental Protection Agency promulgated Standards of Performance for residential wood heaters, or woodstoves. Over the past several years, a number of field studies have been undertaken to determine the actual level of emission reduction achieved by new technology woodstoves in everyday use. These studies have required the development and use of particulate and gaseous emission sampling equipment compatible with operation in private houses. Since woodstoves are tested for certification in the laboratory using EPA Methods 5G and 5H, it is of substantial interest to determine the correlation between these regulatory methods and the in-house equipment. Two in-house sampling systems have been used most widely. One is an intermittent, pump-driven particulate sampler which collects particulate and condensable organics on a filter and organic adsorbent resin. Oxygen concentration is measured by a sensor in the sample line. The sampler is controlled by a data logger which also records other parameters of interest. The second system uses an evacuated cylinder as the motive force. Particulate and condensable organics are collected in a condenser and dual filter. The sampler operates continuously whenever the stack temperature is above the set point. Average stack gas concentrations are measured from the evacuated cylinder at the conclusion of the sampling period. Both samplers were designed to operate unattended for 1-week periods. A large number of tests have been run comparing Methods 5G and 5H to both of the field samplers. This paper presents these comparison data and determines the relationships between laboratory certification sampling methods and field samplers.  相似文献   

19.
Real-time particle sizers provide rapid information about atmospheric particles, particularly peak exposures, which may be important in the development of adverse health outcomes. However, these instruments are subject to erroneous readings in high-humidity environments when compared with measurements from filter-based, federal reference method (FRM) samplers. Laboratory tests were conducted to evaluate the ability of three inlet conditioners to dry aerosol prior to entering a real-time particle sizer for measuring coarse aerosols (Model 3321 Aerodynamic Particle Sizer, APS) under simulated highly humid conditions. Two 30 day field studies in Birmingham, AL, USA were conducted to compare the response of two APSs operated with and without an inlet conditioner to that measured with FRM samplers. In field studies, the correlation of PM(10-2.5) derived from the APS and that measured with the FRM was substantially stronger with an inlet conditioner applied (r2 ranged from 0.91 to 0.99) than with no conditioner (r2 = 0.61). Laboratory experiments confirmed the ability of the heater and desiccant conditioner to remove particle-borne moisture. In field tests, water was found associated with particles across the sizing range of the APS (0.5 microm to 20 microm) when relative humidity was high in Birmingham. Certain types of inlet conditioners may substantially improve the correlation between particulate mass concentration derived from real-time particle sizers and filter-based samplers in humid conditions.  相似文献   

20.
Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号