1.
Adsorbent sampling with analysis by thermal desorption, gas chromatography and mass spectrometry (TD/GC/MS) offers many advantages for volatile organic compounds (VOCs) and thus is increasingly used in many applications. For environmental samples and other complex mixtures, the MS detector typically is operated in the scan mode to aid identification of co-eluting compounds. However, scan mode does not achieve the optimal sensitivity, thus compounds occurring at low concentrations may not be detected. This paper develops and evaluates the application of a more sensitive TD/GC/MS method using selective ion monitoring (SIM) that is applicable to VOC mixtures found in ambient and indoor air. Based on toxicity and prevalence, 94 VOCs (including terpenes, aromatic, halogenated and aliphatic compounds) were selected as target compounds. Two analytical methods were developed: a conventional full scan method for ions from 29 to 270 m/z; and a SIM method using 16 time windows and different ions selected for the compounds in each window. Both methods used the same Tenax GR adsorbent sampling tubes, TD and GC parameters, and target and qualifier ions. Laboratory tests determined calibrations, method detection limits (MDLs), precisions, recoveries and storage stability. Field tests compared scan and SIM mode analyses for duplicate samples of indoor air in 51 houses and outdoor air at 41 sites. Statistical analyses included the development of error/precision models. The laboratory tests showed that most compounds demonstrated excellent precision (<10% for concentrations exceeding approximately 0.5 microg m(-3)), good linearity, near identical calibrations for scan and SIM modes, a wide dynamic range (up to 1500 microg m(-3)), and negligible storage losses after 1 month (7 compounds showed moderate losses). SIM mode MDLs ranged from 0.004 to 0.27 microg m(-3), representing a modest (1.1 to 22-fold) improvement compared to scan mode. However, in field tests the SIM method detected significantly more compounds (e.g., styrene and chloroform). Error models fit most compounds and allow quantification of errors at selected percentiles. Overall, while the new SIM method is somewhat time-consuming to develop, it offers greater sensitivity and maintains the high selectivity of traditional scan methods.  相似文献   

2.
以1个典型食品生产企业(酱菜厂)周边的异味挥发性有机物监测为例,介绍了罐采样-GC/MS、便携式GC/MS、SPME-GC/MS以及SPME-异味分析系统等4种监测方法的实际应用,从定性、定量监测结果等方面,比较了4种监测方法的特点。罐采样-GC/MS、便携式GC-MS 2种方法适用于定性、定量检测,在有标准样品的前提下,定量结果总体可比;SPME-GC/MS以及SPME-异味分析系统2种方法更适用于定性检测。  相似文献   

3.
Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity and ozone concentration. Linearity of samples with loading was examined both for a constant concentration with time varied up to 24 h and for different concentrations over 24 h. Reverse diffusion and its increase with accumulation of sample were determined for all compounds. Tubes were examined for blank levels, change of blanks with storage time, and variability of blanks. Method detection limits were determined based on seven replicate samples. Based on this evaluation, 27 VOCs were selected for quantitative monitoring in the concentration range from approximately 0.1 to 4 ppbv. Comparison results of active and diffusive samples taken over 24 h and under the same simulated ambient conditions at a constant 2 ppbv were interpreted to estimate the effective diffusive sampling rates (ml min(-1)) and their uncertainties and to calculate the corresponding diffusive uptake rates (ng ppmv(-1) min(-1)).  相似文献   

4.
Indoor and ambient concentrations of 21 volatile organic compounds (including 14 hazardous air pollutants) were measured in the homes of nearly 80 western Montana (Missoula) high school students as part of the 'Air Toxics Under the Big Sky' program during the 2004/2005 and 2005/2006 school years. Target analytes were measured using low flow air sampling pumps and sorbent tubes, with analysis of the exposed samples by thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS). The results reported here present the findings of the first indoor/ambient air toxics monitoring program conducted in a semi-rural valley location located in the Northern Rocky Mountain/Western Montana region. Of all of the air toxics quantified in this study, toluene was found to be the most abundant compound in both the indoor and ambient environments during each of the two school years. Indoor log-transformed mean concentrations were found to be higher when compared with ambient log-transformed mean concentrations at P < 0.001 for the majority of the compounds, supporting the results of previous studies conducted in urban areas. For the air toxics consistently measured throughout this program, concentrations were approximately six times higher inside the student's homes compared to those simultaneously measured directly outside their homes. For the majority of the compounds, there were no significant correlations between indoor and ambient concentrations.  相似文献   

5.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   

6.
The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello? samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello? passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello? passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed.  相似文献   

7.
运用热脱附/GC/MS分析研究室内空气中TVOC浓度及种类分布   总被引:4,自引:0,他引:4  
利用热脱附/GC/MS联用技术定性、定量(半定量)分析了多组有代表性的室内空气样品。结果表明,室内空气挥发性有机气体的主要成分是苯系物、烃类、醛酮类、酯类等;装修后3个月内的家居室内空气中的苯25%超标,甲苯58%超标,二甲苯79%超标,TVOC 100%超标;一年后,仅TVOC还有11%的超标。办公室情况类似。  相似文献   

8.
电线电缆行业漆包线生产工艺废气中有机物的GC/MS测定   总被引:1,自引:0,他引:1  
本文以活性炭、TenaxGC、聚氨酯泡沫为吸附材料,用二硫化碳洗脱、二氯甲烷提取、加热解吸三种脱附方式,并以色谱/质谱(GC/MS)联用仪为测试手段,对漆包线生产工艺废气中的有机物进行了测定,共检出72种有机化合物。本文进行了不同采集方式间的比较,提出了电线电缆行业工艺废气中有机化合物的系统分析方法。  相似文献   

9.
针对TH_PKU-300B挥发性有机物快速在线监测系统运行中常见的FID谱图基线不稳定、丙烷峰展宽拖尾、高沸点组分响应下降、GC/MS一直停留在预运行状态、热解析过程中GC进样口压力报警、控制软件温度显示故障、采样体积达不到设定值等故障,分析其产生原因,并提出相应的解决办法和预防措施,同时对TH_PKU-300B系统运维工作提出相关建议。  相似文献   

10.
Studies have shown that biogenic compounds, long chain secondary compounds and long lifetime anthropogenic compounds are involved in the formation of organic aerosols in both polluted areas and remote places. This work aims at developing an active sampling method to monitor these compounds (i.e. 6 straight-chain saturated aldehydes from C6 to C11; 8 straight-chain alkanes from C9 to C16; 6 monoterpenes: α-pinene, β-pinene, camphene, limonene, α-terpinene, & γ-terpinene; and 5 aromatic compounds: toluene, ethylbenzene, meta-, para- and ortho-xylenes) in remote areas. Samples are collected onto multi-bed sorbent cartridges at 200 mL min(-1) flow rate, using the automatic sampler SyPAC (TERA-Environnement, Crolles, France). No breakthrough was observed for sampling volumes up to 120 L (standard mixture at ambient temperature, with a relative humidity of 75%). As ozone has been shown to alter the samples (losses of 90% of aldehydes and up to 95% of terpenes were observed), the addition of a conditioned manganese dioxide (MnO(2)) scrubber to the system has been validated (full recovery of the affected compounds for a standard mixture at 50% relative humidity--RH). Samples are first thermodesorbed and then analysed by GC/FID/MS. This method allows suitable detection limits (from 2 ppt for camphene to 13 ppt for octanal--36 L sampled), and reproducibility (from 1% for toluene to 22% for heptanal). It has been successfully used to determine the diurnal variation of the target compounds (six 3 h samples a day) during winter and summer measurement campaigns at a remote site in the south of France.  相似文献   

11.
By using a dynamic dilution system, the atmospheric measurement of 11 selected toxics VOCs (ethylene, acetylene, propene, 1-butene, 1,3-butadiene, 1-pentene, 1-hexene, benzene, toluene, ethylbenzene, m+p-xylene) from the list WHO of 1996 and TO-14 method of US EPA by preconcentration by thermal desorption (TD), analysis by gas chromatography (GC), identification and quantification with a flame ionisation detector (FID) was developed and validated in term of metrology, especially the techniques of sampling of these VOCs with adsorbents cartridges "Air Toxics" when used with an "UMEG sampler" equipped in the inlet with a nafion membrane. In particular the influence of climatic conditions (temperature and relative humidity) and the influence of chemical factors like ozone, on the representativity of sampling were studied. Experiments made with various humidities showed that the addition of a nafion membrane in the inlet of the sampling system was required. Without this membrane, losses of compounds were observed for RH >50%. With this membrane, storage for 2 weeks in a refrigerator, as for canisters, did not induce a loss of compounds. No significative decrease of concentrations of the studied VOCs after 14 days storage, which are known to react with ozone, were observed with an ozone concentrations of 55 ppb. One explanation is that nafion membrane, placed in the inlet of the sampler, will neutralize ozone before entering the sampling tubes. This observation is in accordance with literature which states that the sampling of VOCs on Carbotrap cartridges without ozone scrubber induce a loss of compounds.  相似文献   

12.
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications.  相似文献   

13.
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.  相似文献   

14.
通过色谱-质谱联用法(简称GC-MS),利用低温冷阱技术对大气中的VOCs进行浓缩富集,然后经过加热解吸分别至毛细管色谱柱和FID检测器及MS检测器,对大气中98种挥发性有机化合物(VOCs)进行分离、定性、定量测定。方法检出限为0.008×10-9~0.100×10-9(V/V);线性相关系数的平方值为0.992 7~1,相对标准偏差为4.0%~20.2%,总体标准偏差为0.154 2~0.952 1。  相似文献   

15.
Monitoring of the workplace concentration of 3-methoxybutyl acetate (MBA), which is used in printer's ink and thinner for screen-printing and as an organic solvent to dissolve various resins, is important for health reasons. An active and a diffusive sampling method, using a gas chromatograph equipped with a flame ionization detector, were developed for the determination of MBA in workplace air. For the active sampling method using an activated charcoal tube, the overall desorption efficiency was 101%, the overall recovery was 104%, and the recovery after 8 days of storage in a refrigerator was more than 90%. For the diffusive sampling method using the 3M 3500 organic vapor monitor, the MBA sampling rate was 19.89 cm(3) min(-1). The linear range was from 0.01 to 96.00 microg ml(-1), with a correlation coefficient of 0.999, and the detection limits of the active and diffusive samplers were 0.04 and 0.07 microg sample(-1), respectively. The geometric mean of stationary sampling and personal sampling in a screen-printing factory were 12.61 and 16.52 ppm, respectively, indicating that both methods can be used to measure MBA in workplace air.  相似文献   

16.
The occurrence of pharmaceutically active chemicals (PACs) in the natural aquatic environment is recognized as an emerging issue due to the potential adverse effects these compounds pose to aquatic life and humans. This study presents the monitoring of two major categories of PACs in surface water: steroid hormones and antibiotics. Surface water samples were collected in the fall season from 21 locations in suburban (4), agricultural (5) and mixed (12) use suburban and agricultural areas. The water samples collected were analyzed using GC/MS for aqueous concentration of eleven steroid hormones: six natural (17alpha-estradiol, 17beta-estradiol, estrone, estriol, 17alpha-dihydroequilin, progesterone) and five synthetic (gestodene, norgestrel, levonorgestrel, medrogestone, trimegestone). In addition, 12 antibiotics (oxytetracycline, chlorotetracycline, tetracycline, sulfamethoxazole, sulfamethazine, trimethoprim, lincomycin, norfloxacin, ofloxacin, roxithromycin, erythromycin, tylosin tartrate) were analyzed using LC/MS. Steroid hormones detected in surface water were: 17alpha-estradiol, 17beta-estradiol, 17alpha-dihydroequilin, estriol, estrone, progesterone and trimegestone. Estrone had the highest detection frequency of >90% with concentrations ranging from 0.6 to 2.6 ng/l. The second most frequently detected estrogen was estriol (>80%) with concentrations ranging from 0.8 to 19 ng/l. The detection frequency varied at different sampling locations. No antibiotics were detected in the 21 streams sampled. This study aims to give a better understanding on the presence, fate and transport of PACs derived from humans and animals.  相似文献   

17.
杭州市居室空气中芳香族化合物污染现状及其来源解析   总被引:3,自引:0,他引:3  
用热解吸/气质联用技术研究了杭州市居室空气中芳香族化合物的组成。结果表明,杭州市居室空气中共存在60种芳香族化合物,其中苯系化合物48种,非苯芳香族化合物12种,检出率大于50%的23种;苯、甲苯、乙苯、苯乙烯、邻二甲苯、间(对)-二甲苯等10种化合物的总含量之和大于85.39%,是室内空气中主要的芳香族污染物,除萘外,其他22种污染物的平均浓度值均随装修时间间隔延长而降低;污染物主要来源是室内装修过程中使用的或装修材料中残留的有机溶剂、机动车辆排放的尾气、居民家庭中常用的清洁用品及含萘等成分的防蛀剂。  相似文献   

18.
Annual trends of a group of 66 volatile organic compounds (VOCs), containing 20 ozone precursors, were the aim of a sampling campaign carried out for a year in air at urban and industrial areas from Tarragona region. VOCs were determined by active collection on multisorbent tubes, followed by thermal desorption and gas chromatography–mass spectrometry. The analytical method was developed and validated, showing good levels of detection and quantification, recoveries, precision, and linearity for all the compounds in the range being studied. All the industrial and urban samples taken during the sampling campaign were similar in their qualitative composition. The most abundant compound in all urban and industrial sites was i-pentane, with concentrations between 15.2 and 202.1 μg m???3 in urban sites and between 1.3 and 98.6 μg m???3 in industrial sites. In urban sites, the following compounds in order of abundance were toluene, n-pentane, m,p-xylene, and o-xylene, with maximum levels of 150.6, 45.8, 42.3, and 31.7 μg m???3, respectively. In industrial sites, the most abundant compounds depended on the sampled site.  相似文献   

19.
The interest in the identification of volatile organic compounds in the workplace has been a major focus of many National Institute for Occupational Safety and Health (NIOSH) field studies. A primary technique for sampling and analysis of these compounds is summarized by NIOSH Manual of Analytical Methods (NMAM) 2549. This is a screening method that uses a multi-bed sorbent to trap a wide variety of compounds and compound classes. Thermal desorption techniques are used as a first attempt to characterize potential contaminants in a workplace and to determine what future sampling and analyses must be performed. Field examples are provided to show the versatility of thermal desorption methods and techniques. Due to their sensitivity, thermal desorption tube methods are sometimes required in order to measure the workplace concentrations of unusual compounds. In other situations, the exposures are too high or varied to make thermal desorption tubes practical. In these cases, the identification of contaminants with thermal desorption tubes leads to new method developments for the quantification of specific compounds using more conventional solid sorbent-solvent desorption based methods.  相似文献   

20.
Fluxes of some Volatile Organic Compounds (VOC) from grass were measured at a golf course in western Sweden, using the Relaxed Eddy Accumulation (REA) technique. The sampling was done by collecting VOC onto adsorbent tubes and the analysis was performed by thermal desorption followed by GC/MS. High emissions were observed after cutting. Transient fluxes of (Z)-3-hexenyl acetate (0.51 microg m(-2) s(-1)), (Z)-3-hexen-1-ol (0.14 microg m(-2) s(-1)) and (Z)-3-hexenal (0.40 microg m(-2) s(-1)) were measured, even at low temperatures. The REA technique requires a relatively large fetch area that is sometimes not available. Therefore, a procedure for correcting measured fluxes from a limited fetch is suggested.  相似文献   