首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

2.
The system performance of a trickle bed biofilter for treating single and mixed benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors from waste gases was investigated under different gas flow rates and influent BTEX concentrations. When a single substrate was fed, removal efficiencies of greater than 90% could be achieved for the loads below 64 g benzene/m3/hr, 110 g toluene/m3/hr, 53 g ethylbenzene/m3/hr, and 55 g o-xylene/m3/hr. When a mixed substrate was fed, removal efficiencies of each compound could be above 90% at BTEX loads below 96 g/m3/hr. The trickle bed biofilter appears to be an effective treatment process for removing both single and mixed BTEX vapors with low to high loads. Under similar substrate loads, BTEX vapors were preferentially biodegraded in the order of toluene, benzene, o-xylene, and ethylbenzene. The volumetric removal rates (elimination capacities) of BTEX vapors for a single-substrate feed were higher than those for a mixed-substrate feed under similar substrate loads; these differences were enhanced at higher substrate loads and less significant for a preferred substrate.  相似文献   

3.
The objective of this research was to investigate a sequentially loaded and regenerated granular activated carbon (GAC) biofilter system and to determine whether regenerative ozonation/advanced oxidation could improve the removal and biodegradation of a volatile organic compound from a contaminated airstream. Bench-scale reactors were constructed to operate in a manner analogous to a commercially available system manufactured by Terr-Aqua Environmental Systems (only with longer contact time). The GAC system consisted of two GAC biofilter beds that operated in a cyclical manner. On a given day, the first GAC bed adsorbed methyl isobutyl ketone from a simulated waste airstream, while the second bed underwent regeneration; then on the next day, the second bed was in the adsorption mode while the first was regenerated. Three bench-scale systems were used to compare the performance under three operating conditions: (1) ozone/ associated oxidant regeneration of a GAC biofilter system that was seeded with microorganisms from a field site, (2) a humid air regeneration of a seeded GAC biofilter, and (3) a humid air regeneration of an unseeded GAC biofilter. For the advanced oxidant regenerated GAC biofilter, a maximum removal efficiency of >95% was achieved with an empty bed contact time of 148 sec and an influent concentration of 125 ppm methyl isobutyl ketone, and 90-95% was achieved at 148-sec empty bed contact time and a 1150-ppm influent.  相似文献   

4.
Abstract

The objective of this research was to investigate a sequentially loaded and regenerated granular activated carbon (GAC) biofilter system and to determine whether regenerative ozonation/advanced oxidation could improve the removal and biodegradation of a volatile organic compound from a contaminated airstream. Bench-scale reactors were constructed to operate in a manner analogous to a commercially available system manufactured by Terr-Aqua Environmental Systems (only with longer contact time). The GAC system consisted of two GAC biofilter beds that operated in a cyclical manner. On a given day, the first GAC bed adsorbed methyl isobutyl ketone from a simulated waste airstream, while the second bed underwent regeneration; then on the next day, the second bed was in the adsorption mode while the first was regenerated.

Three bench-scale systems were used to compare the performance under three operating conditions: (1) ozone/ associated oxidant regeneration of a GAC biofilter system that was seeded with microorganisms from a field site, (2) a humid air regeneration of a seeded GAC biofilter, and (3) a humid air regeneration of an unseeded GAC biofilter. For the advanced oxidant regenerated GAC biofilter, a maximum removal efficiency of >95% was achieved with an empty bed contact time of 148 sec and an influent concentration of 125 ppm methyl isobutyl ketone, and 90–95% was achieved at 148-sec empty bed contact time and a 1150-ppm influent.  相似文献   

5.
ABSTRACT

Trickle-bed air biofilters (TBABs) are suitable for treatment of hydrophilic volatile organic compounds, but they pose a challenge for hydrophobic compounds. Three laboratory-scale TBABs were used for the treatment of an airstream contaminated with different ratios of n-hexane and benzene mixtures. The ratios studied were 1:1, 2:1, and 1:3 n-hexane:benzene by volume. Each TBAB was operated at a pH of 4 and a temperature of 20 °C. The use of acidic-buffered nutrient solution was targeted for changing the microorganism consortium to fungi as the main biodegradation element. The experimental plan was designed to investigate the long-term performance of the TBABs with an emphasis on different mixture loading rates, removal efficiency with TBAB depth, volatile suspended solids, and carbon mass balance closure. n-Hexane loading rate was kept constant in the TBABs for comparison reasons and ranged from 4 to 22 g/(m3.hr). Corresponding benzene loadings ranged from 4 to 43 g/(m3.hr). Generally, benzene behavior in the TBAB was superior to that of n-hexane because of its higher solubility. n-Hexane showed improved performance in the 2:1 mixing ratio as compared with the other two ratios.

IMPLICATIONS The use of biofilters is a cheap and attractive option; however, their application is limited because of several challenges. One of them is the reluctance of hydrophobic compounds for biodegradation and the coexistence of other compounds in air emissions. This paper evaluated the impact of different mixing ratios of two hydrophobic compounds and the effect of increasing influent concentration. Finally, a comparison is provided on the best performance attained for these hydrophobic compounds as single solutes. The results of this study will aid in the design and operation of full-scale biofilters.  相似文献   

6.
Wang J  Chen S  Nie X  Tian M  Luo X  An T  Mai B 《Chemosphere》2012,89(7):844-849
The photolytic degradation of decabromodiphenyl ethane (DBDPE), an alternative flame retardant to decabromodiphenyl ether, was investigated in a variety of matrixes (n-hexane, tetrahydrofuran, methanol/water, humic acid/water, and silica gel) by irradiation under ultraviolet light and in n-hexane under natural light. Photolytic degradation of DBDPE occurs in all the matrixes investigated within the irradiation period (<320 min). The degradation experiments showed varied reaction rates, dependent on the matrixes, with increasing half-lives (t1/2) in the order of tetrahydrofuran (t1/2 = 6.0 min) > n-hexane (t1/2 = 16.6 min) > humic acid/water (30 < t1/2 < 60) > silica gel (t1/2 = 75.9 min) > methanol/water (t1/2 > 240 min). The reaction in tetrahydrofuran, n-hexane, and silica gel matrixes can be described by the pseudo first order kinetics. Nevertheless, the matrixes have little effect on the degradation product distributions of DBDPE. A numbers of debrominated intermediates were identified. The degradation involves the initial formation of nona-BDPEs and the subsequent decomposition of these congeners to lower brominated congeners (octa- and hepta-BDPEs) within the irradiation time. To our knowledge, the present work is the first attempt to investigate the photolytic degradation kinetics and the identification of intermediates, as well as the degradation mechanism, during the degradation of DBDPE. Further research is needed to understand the photolytic degradation pattern of DBDPE in the natural environment.  相似文献   

7.
ABSTRACT

With the advances made in the past decade, catalytic incineration of volatile organic compounds (VOCs) has become the technology of choice in a wide range of pollution abatement strategies. In this study, a test was undertaken for the catalytic incineration, over a chromium oxide (Cr2O3) catalyst, of n-hexane, benzene, and an emission air/vapor mixture collected from an oil/water separator of a refinery. Reactions were carried out by controlling the feed stream to constant VOC concentrations and temperatures, in the ranges of 1300–14,700 mg/m3 and 240–400 ° C, respectively. The destruction efficiency for each of the three VOCs as a function of influent gas temperature and empty bed gas residence time was obtained.

Results indicate that n-hexane and the oil vapor with a composition of straight- and branch-chain aliphatic hydrocarbons exhibited similar catalytic incineration effects, while benzene required a higher incineration temperature or longer gas retention time to achieve comparable results.

In the range of the VOC concentrations studied, at a given gas residence time, increasing the operating temperature of the catalyst bed increased the destruction efficiency. However, the much higher temperatures required for a destruction efficiency of over 99% may be not cost-effective and are not suggested. A first-order kinetics with respect to VOC concentration and an Arrhenius temperature dependence of the kinetic constant appeared to be an adequate representation for the catalytic oxidation of these volatile organics. Activation energy and kinetic constants were estimated for each of the VOCs. Low-temperature destruction of the target volatile organics could be achieved by using the Cr2O3 catalyst.  相似文献   

8.
The microalgae could be multiplied by supplying only sewage influent or effluent without any additional microalgal stock or nutrient salt. In a semicontinuous culture, the N:P weight ratios consumed were 14:1 and 18:1 for the sewage influent and effluent, respectively. The total cell number and green algae ratio of microalgae cultivated by semicontinuous culture exceeded those of batch culture. No cyanobacterial cells were observed in the semicontinuous culture using the sewage effluent. The organic components in the cultured microalgae using sewage effluent, eluted by n-hexane, were determined. The ratio of unsaturated fatty acid exceeded that of saturated fatty acid, which was possibly attributable to the fluidity of the cell membrane. The squalene was also obtained by the culture using sewage alone, free of any external stock or nutrient salt. The higher heating value of the microalgae of semicontinuous culture using the sewage influent was 25 MJ kg−1, corresponding to the heating value of lignite and showing the potential of the sewage culture microalgae as a means of power generation and combustion aid.  相似文献   

9.
Abstract

Although aldehydes contribute to ozone and particulate matter formation, there has been little research on the biofiltration of these volatile organic compounds (VOCs), especially as mixtures. Biofiltration degradation kinetics of an aldehyde mixture containing hexanal, 2-methylbutanal (2-MB), and 3-methylbutanal (3-MB) was investigated using a bench-scale, synthetic, media-based biofilter. The adsorption capacity of the synthetic media for a model VOC, 3-methylbutanal, was 10 times that of compost. Periodic residence time distribution analysis (over the course of 1 yr) via a tracer study (84–99% recovery), indicated plug flow without channeling in the synthetic media and lack of compaction in the reactor. Simple first-order and zero-order kinetic models both equally fit the experimental data, yet analysis of the measured rate constants versus fractional conversion suggested an overall first-order model was more appropriate. Kinetic analysis indicated that hexanal had a significantly higher reaction rate (k = 0.09 ± 0.005 1/sec; 23 ± 1.3 ppmv) compared with the branched aldehydes (k = 0.04 ± 0.0036 1/sec; 31 ± 1.6 ppmv for 2-MB and 0.03 ± 0.0051 1/sec; 22 ± 1.3 ppmv for 3-MB). After 3 months of operation, all three compounds reached 100% removal (50 sec residence time, 18–46 ppmv inlet). Media samples withdrawn from the biofilter and observed under scanning electron microscopy analysis indicated microbial growth, suggesting removal of the aldehydes could be attributed to biodegradation.  相似文献   

10.
Abstract

Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

11.
Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

12.
Although aldehydes contribute to ozone and particulate matter formation, there has been little research on the biofiltration of these volatile organic compounds (VOCs), especially as mixtures. Biofiltration degradation kinetics of an aldehyde mixture containing hexanal, 2-methylbutanal (2-MB), and 3-methylbutanal (3-MB) was investigated using a bench-scale, synthetic, media-based biofilter. The adsorption capacity of the synthetic media for a model VOC, 3-methylbutanal, was 10 times that of compost. Periodic residence time distribution analysis (over the course of 1 yr) via a tracer study (84-99% recovery), indicated plug flow without channeling in the synthetic media and lack of compaction in the reactor. Simple first-order and zero-order kinetic models both equally fit the experimental data, yet analysis of the measured rate constants versus fractional conversion suggested an overall first-order model was more appropriate. Kinetic analysis indicated that hexanal had a significantly higher reaction rate (k = 0.09 +/- 0.005 1/sec; 23 +/- 1.3 ppmv) compared with the branched aldehydes (k = 0.04 +/- 0.0036 1/sec; 31 +/- 1.6 ppmv for 2-MB and 0.03 +/- 0.0051 1/sec; 22 +/- 1.3 ppmv for 3-MB). After 3 months of operation, all three compounds reached 100% removal (50 sec residence time, 18-46 ppmv inlet). Media samples withdrawn from the biofilter and observed under scanning electron microscopy analysis indicated microbial growth, suggesting removal of the aldehydes could be attributed to biodegradation.  相似文献   

13.
The goal of this study was to compare removal efficiencies of tetrabromobisphenol A (TBBPA) using typical wastewater treatment technologies, and to identify the most significant mechanisms of removal. Two types of municipal wastewater reactors were studied: a full-scale conventional activated sludge (CAS) reactor with tertiary treatment; and three pilot-scale membrane bioreactors (MBRs) having different sludge retention times (SRTs). All four reactors were fed the same influent. A third reactor type, a membrane aerated biofilm reactor (MABR) was fed tap water, ammonia, and TBBPA. TBBPA in municipal influent ranged from 1 to 41 ng L−1 (n = 10). The CAS effluent had an average TBBPA concentration of 0.7 ± 1.3 ng L−1 (n = 3). Effluent concentrations from the MBRs were an average of 6 ± 6 ng L−1 TBBPA (n = 26). Significant TBBPA removal was observed in the MABR throughout the 5 week of study (p ? 0.05). Removal of TBBPA from wastewater treatment was found to be due to a combination of adsorption and biological degradation. Based on experimental results, nitrification is likely a key process therein. No significant relationship between removal of TBBPA and SRT was identified (p ? 0.05).  相似文献   

14.
Herbicide leaching through soil into groundwater greatly depends upon sorption-desorption and degradation phenomena. Batch adsorption, desorption and degradation experiments were performed with acidic herbicide MCPA and three soil types collected from their respective soil horizons. MCPA was found to be weakly sorbed by the soils with Freundlich coefficient values ranging from 0.37 to 1.03 mg1−1/n kg−1 L1/n. It was shown that MCPA sorption positively correlated with soil organic carbon content, humic and fulvic acid carbon contents, and negatively with soil pH. The importance of soil organic matter in MCPA sorption by soils was also confirmed by performing sorption experiments after soil organic matter removal. MCPA sorption in these treated soils decreased by 37-100% compared to the original soils. A relatively large part of the sorbed MCPA was released from soils into aqueous solution after four successive desorption steps, although some hysteresis occurred during desorption of MCPA from all soils. Both sorption and desorption were depth-dependent, the A soil horizons exhibited higher retention capacity of the herbicide than B or C soil horizons. Generally, MCPA sorption decreased in the presence of phosphate and low molecular weight organic acids. Degradation of MCPA was faster in the A soil horizons than the corresponding B or C soil horizons with half-life values ranging from 4.9 to 9.6 d in topsoils and from 11.6 to 23.4 d in subsoils.  相似文献   

15.
Kim D  Sorial GA 《Chemosphere》2007,66(9):1758-1764
The effects of temporal and spatial changes in biological activity and biomass amount on biofilter performance were investigated in a lab-scale trickle-bed air biofilter at a toluene loading of 46.9gm(-3)h(-1) under two different experimental strategies, namely, periodic backwashing at a rate of 1h once a week and 2d starvation. Analysis of the overall reaction for toluene metabolism revealed that cell synthesis was relatively favored over toluene oxidation in the inlet section of the biofilter, but over time its oxidation became favored throughout the biofilter bed. Periodic in situ backwashing with media fluidization effectively made even spatial distribution of biomass along the bed media, by which consistent high removal performance in the biofilter has been attained. After 2d starvation, the ratio of the biofilm EPS to the total biomass increased along the media bed depth, while the total biomass in the media bed subsequently decreased. The presence of sufficient biomass and microbial activity favorably influenced biofilter reacclimation after restart-up following starvation.  相似文献   

16.
C Lu  M R Lin  J Lin 《Chemosphere》2001,44(2):173-180
The system performance of a trickle-bed air biofilter (TBAB) for treating N,N-dimethylacetamide (DMAC) waste gas was investigated under different gas flow rates and influent concentrations. In the pseudo-steady-state conditions, the DMAC elimination capacity increased but the removal efficiency decreased as the influent loading increased. More than 90% and 80% DMAC removal efficiencies are achieved for influent loadings below 20.2 and 34.5 g DMAC/m3/h, respectively. The TBAB appears to be an effective treatment process for controlling DMAC emission with low-to-medium loadings and the effectiveness could be maintained over a long-period operation.  相似文献   

17.
以颗粒活性炭为填料,采用盐度梯度两步驯化法构建含盐水体生物滤器硝化功能,研究了生物滤器稳定后水力停留时间(hydraulic retention time,HRT)、进水氨氮负荷和CODMn/N等对反应器硝化性能的影响。结果表明,25~27℃,盐度30的含盐水体生物滤器硝化功能构建需73 d,其中淡水生物滤器硝化功能构建需28 d,淡水驯化为盐度15的生物滤器需19 d,盐度15驯化为盐度30的生物滤器需26 d;实验条件下生物活性炭填料反应器中生物量达到146~742.1 nmolP/g-BAC;调节进水氨氮浓度2 mg/L左右时,最佳HRT为1 h,氨氮去除率达到84.98%,相应的氨氧化菌和硝酸菌氧吸收速率(oxygen uptake rate,OUR)分别为2.091和1.948 mg O2/(g-BAC.h);HRT为1 h时,随着进水氨氮负荷的加大,氨氮去除率逐渐降低,当进水氨氮负荷由0.12增加到0.48 g-N/(kg-BAC.d)时,氨氮去除率由84.98%降低到41.68%,同时氨氧化菌OUR由2.091降低到0.625 mg O2/(g-BAC.h);随着CODMn/N的升高,氨氮去除率下降,CODMn/N从1~8时,氨氮去除率由84.98%降低到53.64%,CODMn去除率却逐渐增加,由40.86%增加到93.59%,异养菌OUR随着CODMn/N升高呈上升趋势,最大达到0.914 mg O2/(g-BAC.h)。  相似文献   

18.
ABSTRACT

This paper presents results obtained from a performance study on the biotreatment of 1,3-butadiene in an air stream using a reactor that consisted of a two-stage, in-series biotrickling filter connected with a three-stage, in-series biofilter. Slags and pig manure-based media were used as packing materials for the biotrickling filter and the biofilter, respectively. Experimental results indicated that, for the biotrickling filter portion, the butadiene elimination capacities were below 5 g/m3/hr for loadings of less than 25 g/m3/hr, and the butadiene removal efficiency was only around 17%. For the biofilter portion, the elimination capacities ranged from 10 to 107 g/m3/hr for loadings of less than 148 g/m3/hr. The average butadiene removal efficiency was 75–84% for superficial gas velocities of 53–142 m/hr and a loading range of 10–120 g/m3/hr. The elimination capacity approached a maximum of 108 g/m3/hr for a loading of 150 g/m3/hr. The elimination rates of butadiene in both the biotrickling filter and biofilter were mass-transfer controlled for influent butadiene concentrations below about 600 ppm for superficial gas velocities of 29–142 m/hr. The elimination capacity was significantly higher in the biofilter than in the biotrickling filter. This discrepancy may be attributed to the higher mass-transfer coefficient and gas-solid interfacial area offered for transferring the gaseous butadiene in the biofilter.  相似文献   

19.
Converting lipid-extracted microalgal wastes to methane (CH4) via anaerobic digestion (AD) has the potential to make microalgae-based biodiesel platform more sustainable. However, it is apparent that remaining n-hexane (C6H14) from lipid extraction could inhibit metabolic pathway of methanogens. To test an inhibitory influence of residual n-hexane, this study conducted a series of batch AD by mixing lipid-extracted Chlorella vulgaris with a wide range of n-hexane concentration (~10 g chemical oxygen demand (COD)/L). Experimental results show that the inhibition of n-hexane on CH4 yield was negligible up to 2 g COD/L and inhibition to methanogenesis became significant when it was higher than 4 g COD/L based on quantitative mass balance. Inhibition threshold was about 4 g COD/L of n-hexane. Analytical result of microbial community profile revealed that dominance of alkane-degrading sulfate-reducing bacteria (SRB) and syntrophic bacteria increased, while that of methanogens sharply dropped as n-hexane concentration increased. These findings offer a useful guideline of threshold n-hexane concentration and microbial community shift for the AD of lipid-extracted microalgal wastes.  相似文献   

20.
Abstract

In this research, pilot-scale trickle bed biofilter systems have been analyzed to determine their effectiveness in controlling toluene in waste gas streams. These studies evaluated two synthetic microbial attachment media—a monolithic channelized medium and a pelletized ceramic medium. Operational parameters considered included toluene loading, empty bed residence time (EBRT), temperature, and long-term operation. The channelized medium provided 99% removal efficiency for a toluene loading of 0.725 kg COD/m3-day during the initial stages. However, continuous operation resulted in reduced and erratic efficiencies, due to air channeling caused by random plugging. After biomass accumulated within the channels and was subsequently removed by hosing, performance of the channelized medium never regained the previous levels. Similarly, the pelletized medium exhibited consistently good performance until the accumulation of excess biomass in the medium interstices also caused overall performance to deteriorate.

Implementation of a suitable backwashing strategy for biomass control was achieved for the pelletized medium by using full medium fluidization. This strategy permitted long-term operation of the biofilter at a toluene loading of 2.27 kg COD/m3-day and 1 minute EBRT, with efficiencies consistently over 99% and no appreciable back-pressure development between successive periods of backwashing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号