1.
Kavitha V  Palanivelu K 《Chemosphere》2004,55(9):1235-1243
The efficiency of different Fenton-related oxidative processes such as Fenton, solar-Fenton and UV-Fenton were examined using phenol as a model compound in simulated and industrial wastewater. A batch study was conducted to optimize parameters like pH, hydrogen peroxide concentration and ferrous ion concentration governing the Fenton process. At optimum conditions, different Fenton-related processes were compared for the degradation of phenol. Increased degradation and mineralisation efficiency were observed in photo-Fenton processes as compared to conventional Fenton process. The maximum mineralising efficiency for phenol with Fenton, solar and UV-Fenton processes were 41%, 96% and 97% respectively. In Fenton process, carboxylic acids like acetic acid and oxalic acid were formed as end products during the degradation of phenol while in photo-Fenton processes, both these ions were identified during the early stages of phenol degradation and were oxidized almost completely at 120 min of the reaction time. In photo-Fenton processes (solar and UV light) complete degradation were observed with 0.4 mM of Fe2+ catalyst as compared to 0.8 mM of Fe2+ in conventional Fenton process. In Fenton and solar-Fenton processes, an iron reusability study was performed to minimize the amount of iron used in treatment process. The efficacy of Fenton and solar-Fenton processes was applied to effluent from phenol resin-manufacturing unit for the removal and mineralisation of phenol.  相似文献   

2.
Iron-loaded mangosteen shell powder (Fe-MSP) was found as an effective heterogeneous Fenton catalyst for the treatment of stabilized landfill leachate. Sonolytically produced catalyst has higher efficiency than other catalysts. At the optimal conditions (pH 3, catalyst concentration of 1,750 mg/L and hydrogen peroxide concentration of 0.26 M), 81 % of the chemical oxygen demand (COD) was removed effectively from the landfill leachate. But, the efficiency of Fe-MSP was reduced in the first recycling due to the poisoning of active sites. A metal leaching study indicated that the degradation of the pollutant is mainly due to solid Fe ions present in Fe-MSP rather than the leached ferrous and ferric ions. Hydroxyl radical production in the system was confirmed by the Fenton oxidation of benzoic acid. Compared to the homogeneous Fenton process, the heterogeneous Fenton process using Fe-MSP had higher COD removal efficiency, indicating the practical applicability of the prepared catalyst.  相似文献   

3.
Intensive use of chlorinated pesticides from the 1960s to the 1990s has resulted in a diffuse contamination of soils and surface waters in the banana-producing areas of the French West Indies. The purpose of this research was, for the first time, to examine the degradation of two of these persistent pollutants – chlordecone (CLD) and beta-hexachlorocyclohexane (β-HCH) in 1 mg L?1 synthetic aqueous solutions by means of photolysis, (photo-) Fenton oxidation and ozonation processes. Fenton oxidation is not efficient for CLD and yields less than 15% reduction of β-HCH concentration in 5 h. Conversely, both molecules can be quantitatively converted under UV-Vis irradiation reaching 100% of degradation in 5 h, while combination with hydrogen peroxide and ferrous iron does not show any significant improvement except in high wavelength range (>280 nm). Ozonation exhibits comparable but lower degradation rates than UV processes. Preliminary identification of degradation products indicated that hydrochlordecone was formed during photo-Fenton oxidation of CLD, while for β-HCH the major product peak exhibited C3H3Cl2 as most abundant fragment.  相似文献   

4.
Glucose oxidase is a well-known enzyme that catalyzes the oxidation of β-d-glucose to produce gluconic acid and hydrogen peroxide. Fenton reaction is a powerful oxidation technology used for the oxidation of groundwater pollutants. For the application of Fenton reaction in groundwater remediation, successful operation of Fenton reaction near neutral pH, and on-site generation of both H2O2 and chelate will be beneficial. The focus of this experimental study was to couple the glucose oxidation reaction with chelate-based Fenton reaction. The idea was to use the hydrogen peroxide and chelate gluconic acid generated during glucose oxidation for the dechlorination of 2,4,6-trichlorophenol (TCP) by Fenton reaction. The oxidation of glucose was achieved using the enzyme in free and immobilized forms. The rate of production of hydrogen peroxide was determined for each system, and was used to estimate the time required for complete consumption of glucose during the process, thus avoiding any traces of glucose in the Fenton reaction. In the case of free enzyme reaction, separation of the enzyme was achieved using an ultrafiltration membrane before initiating the Fenton reaction. The oxidation of TCP by Fenton reaction was performed at varying ratios of gluconic acid/Fe, and its effect on the decomposition of TCP and H2O2 was studied. TCP degradation was studied both in terms of parent compound degradation and free chloride generation.  相似文献   

5.
超声-Fenton法处理偶氮染料橙黄II的研究   总被引:1,自引:0,他引:1  
以偶氮染料橙黄II为研究对象 ,考察了Fenton反应在超声辐射条件下 ,pH值、H2 O2 浓度、Fe2 + 离子浓度对COD去除率的影响。实验结果表明 ,超声对Fenton试剂处理偶氮染料橙黄II具有强化作用。超声条件下 ,当染料浓度为10 0mg/L、pH为 3.0、Fe2 + 离子浓度为 10mg/L、H2 O2 浓度为 4 0 0mg/L时 ,反应 90min ,COD去除率最高可达 93%。  相似文献   

6.
The degradation of ciprofloxacin was studied in aqueous solutions by using a continuous flow homogeneous photo-Fenton process under simulated solar light. The effect of different operating conditions on the degradation of ciprofloxacin was investigated by changing the hydrogen peroxide (0–2.50 mM) and iron(II) sulphate (0–10 mg Fe L?1) concentrations, as well as the pH (2.8–10), irradiance (0–750 W m?2) and residence time (0.13–3.4 min) of the process. As expected, the highest catalytic activity in steady state conditions was achieved at acidic pH (2.8), namely 85 % of ciprofloxacin conversion, when maintaining the other variables constant (i.e. 2.0 mg L?1 of iron(II), 2.50 mM of hydrogen peroxide, 1.8 min of residence time and 500 W m?2 of irradiance). Additionally, magnetite magnetic nanoparticles (ca. 20 nm of average particle size) were synthesized, characterized and tested as a possible catalyst for this reaction. In this case, the highest catalytic activity was achieved at natural pH, namely a 55 % average conversion of ciprofloxacin in 1.8 min of residence time and under 500 W m?2. Some of the photocatalytic activity was attributed to Fe2+ leaching from the magnetic nanoparticles to the solution.  相似文献   

7.
The main disadvantage of using iron mineral in Fenton-like reactions is that the decomposition rate of organic contaminants is slower than in classic Fenton reaction using ferrous ions at acidic pH. In order to overcome these drawbacks of the Fenton process, chelating agents have been used in the investigation of Fenton heterogeneous reaction with some Fe-bearing minerals. In this work, the effect of new iron complexing agent, ethylenediamine-N,N'-disuccinic acid (EDDS), on heterogeneous Fenton and photo-Fenton system using goethite as an iron source was tested at circumneutral pH. Batch experiments including adsorption of EDDS and bisphenol A (BPA) on goethite, H2O2 decomposition, dissolved iron measurement, and BPA degradation were conducted. The effects of pH, H2O2 concentration, EDDS concentration, and goethite dose were studied, and the production of hydroxyl radical (?OH) was detected. The addition of EDDS inhibited the heterogeneous Fenton degradation of BPA but also the formation of ?OH. The presence of EDDS decreases the reactivity of goethite toward H2O2 because EDDS adsorbs strongly onto the goethite surface and alters catalytic sites. However, the addition of EDDS can improve the heterogeneous photo-Fenton degradation of BPA through the propagation into homogeneous reaction and formation of photochemically efficient Fe-EDDS complex. The overall effect of EDDS is dependent on the H2O2 and EDDS concentrations and pH value. The high performance observed at pH 6.2 could be explained by the ability of O 2 ?? to generate Fe(II) species from Fe(III) reduction. Low concentrations of H2O2 (0.1 mM) and EDDS (0.1 mM) were required as optimal conditions for complete BPA removal. These findings regarding the capability of EDDS/goethite system to promote heterogeneous photo-Fenton oxidation have important practical implications for water treatment technologies.  相似文献   

8.
Oxidation of TNT by photo-Fenton process   总被引:4,自引:0,他引:4  
Liou MJ  Lu MC  Chen JN 《Chemosphere》2004,57(9):1107-1114
A series of photo-Fenton reactions have been performed for the degradation of 2,4,6-trinitrotoluene (TNT) in a 4.2-l reactor. The degradation reaction rate of TNT followed a pseudo-first-order behavior; and the rate constants for 2.4mW cm(-2)UV only, 2.4mW cm(-2)UV/H(2)O(2), Fenton, photo-Fenton (2.4mW cm(-2)) and photo-Fenton (4.7mW cm(-2)) were 0.002min(-1), 0.007min(-1), 0.014min(-1), 0.025min(-1) and 0.037min(-1), respectively. Increasing the intensity of UV light, and the concentrations of ferrous ions and hydrogen peroxide promoted the oxidation rate under the experimental conditions in this study. The weighting factor (f), the Fe(II)-promoted efficiency (r) and the promoted-UV light efficiency (p) were calculated to clarify their effects on the TNT oxidation. Moreover, the inhibition effect of hydroxyl radical was also observed in both Fenton and photo-Fenton oxidation when the concentration of Fe(II) were higher than 2.88mM. Solid phase micro-extraction was first applied to the separation of the organic byproducts from TNT oxidation. GC/MS was employed to identify the byproducts during the Fenton and photo-Fenton oxidation of TNT. These compounds were clarified as 1,3,5-trinitrobenzene, 1-methyl-2,4-dinitrobenzene 2,5-dinitrobenzoic acid and 1,3-dinitrobenzene. By these byproducts, the mechanisms of the methyl group oxidation, decarboxylation, aromatic ring breakage, and hydrolysis can be recognized and demonstrated. The pathway of TNT oxidation by photo-Fenton process was also proposed in this study.  相似文献   

9.
针对内蒙古农村地区高腐殖酸地下水的处理问题,分别对(pH调节)-PAC强化混凝、高锰酸钾预氧化/混凝、活性炭吸附/混凝、Fenton氧化等技术处理的可行性进行了研究,同时利用三维荧光和高效体积排阻色谱分析处理前后水中有机物的组成变化特征。有机分析结果显示,水中的有机物为腐殖酸类物质,分子量分别为1600和3500,腐殖酸类物质为水中色度的主要贡献者。原水PAC强化混凝、高锰酸钾预氧化/PAC混凝对有机物的去除效果不佳,处理前后水样DOC浓度无明显变化,而pH调节.PAC强化混凝、微米活性炭吸附和Fenton氧化均能有效去除有机物。将原水pH调节至6.5,经300mg/LPAC混凝后出水DOC降至5.99mg/L。活性炭投加量为0.6g/L时,DOC降至7.6mg/L,然后采用60mg/LPAC混凝出去高度分散而不易沉降的小颗粒活性炭。此外,当反应初始pH值为3,过氧化氢投加量为0.5%(v/v),亚铁和双氧水摩尔比为0.05时,出水DOC降至5.6mg/L,氧化后有小分子有机物生成。  相似文献   

10.
Kwan CY  Chu W 《Chemosphere》2007,67(8):1601-1611
Recent studies have shown that hydrogen peroxide is generated in a ferrioxalate-induced photoreductive reaction, but information about the effect of organic ligands on the photochemical behaviour of ferrous species is limited. The degradation of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) by a ferrous-catalyzed oxidation in the presence of various ligands such as formate, citrate, malelate, oxalate, and ethylenediaminetetra-acetic acid (EDTA) was studied. The experiments were conducted under either dark or irradiated (350n m) conditions. Forty-two percent and 34% of 2,4-D were removed by the Fe(2+)/oxalate/UV and Fe(2+)/citrate/UV processes, respectively, after 30 min of reaction and oxidative intermediates were obtained in both cases. The presence of hydroxylated intermediates suggests that 2,4-D may be attacked by hydroxyl radicals, which are the products of the photo-Fenton-like reaction. As such, hydrogen peroxide was produced by the photolysis of ferrous oxalate or ferrous citrate, referred to hereafter as photogenerated H(2)O(2). As expected, the total removal percentage of 2,4-D jumped to 97% when 1mM of hydrogen peroxide (so-called spiked H(2)O(2)) was externally added to the reaction vessel to initiate the Fe(2+)/oxalate/UV process. Therefore, the treatment of 2,4-D by the Fe(2+)/oxalate/H(2)O(2)/UV system can be operated in two steps: the photolysis of ferrous oxalate first, followed by adding the spiked H(2)O(2) sometime after the commencement of the reaction. A two-phase model has been developed to describe this tandem ferrous-catalyzed photooxidation, which would help to achieve the mineralization of 2,4-D.  相似文献   

11.
A Fenton oxidation system employing zero-valent iron (whose source was swarf, a residue of metallurgical industries, in powder form) and hydrogen peroxide for the treatment of an aqueous solution with six pesticides was developed, and the effect of the iron metal content, pH, and hydrogen peroxide concentration was evaluated. The characterization of the aqueous solution resulted in: pH 5.6, 105 mg L?1 of dissolved organic carbon, and 44.6 NTU turbidity. In addition, the characterization of the swarf by FAAS and ICP-MS showed 98.43?±?7.40 % of zero-valent iron. The removal was strongly affected by the content of iron metal, pH, and hydrogen peroxide concentration. The best degradation conditions were 2.0 g swarf, pH 2.0, and 5 mmol L?1 H2O2. At the end of the treatment, the pesticide degradation ranged from 60 to 100 %, leading to 55 % mineralization. Besides, all hydrogen peroxide was consumed and the determination of total dissolved iron resulted in 2 mg L?1. Thus, the advantages of this system are rapid degradation (up to 20 min), high-degradation rates, simple handling, and low cost.
Figure
A Fenton oxidation system employing Fe0 (in which the source of Fe0 was swarf, a residue in powder form of metallurgical industries) and H2O2 for the degradation of synthetic wastewater comprising six pesticides was developed, and the effect of the amount of Fe0, pH, and H2O2 concentration was evaluated.  相似文献   

12.
CuO/γ-Al_2O_3类Fenton试剂降解丁基黄药   总被引:1,自引:0,他引:1  
CuO/γ-Al2O3类Fenton试剂是降解丁基黄药的优良试剂。该试剂与传统的Fenton试剂相比,提高了反应的pH值,可在较高pH(4~5)条件下反应,而传统的Fenton试剂的适宜pH值一般在3以下。采用单因素实验和正交实验相结合的方法研究了pH、催化剂投加量、过氧化氢投加量以及反应时间对丁基黄药降解效果的影响,并对催化剂的使用寿命进行了探讨。研究结果表明,反应的最佳条件为:pH为4~5,催化剂投加量为6 g/L,过氧化氢用量为30 mg/L,反应30min。在此反应条件下,丁基黄药的降解率达98%以上;影响丁基黄药降解效果的因素大小顺序为:pH〉反应时间〉H2O2用量〉催化剂投加量,其中pH对CuO/γ-Al2O3类Fenton试剂降解丁基黄药的影响最为显著。  相似文献   

13.
研究了UV/Fenton技术对高浓度金属清洗乳化油废水的处理效果,考察了亚铁与双氧水浓度、pH、反应时间和搅拌对COD去除效果的影响。实验结果表明,UV/Fenton技术对高浓度乳化油废水(COD平均浓度为35 000 mg/L)具有较高的去除效果,最佳工艺条件为:亚铁与双氧水浓度分别为2 400 mg/L和6 000 mg/L,pH为3,经过2 h反应,COD可降低至1 050 mg/L,去除率为97%。搅拌会降低COD的去除率。研究表明,UV/Fenton技术对高浓度乳化油废水具有很好的降解效果,且药品消耗较低,为目前此类高浓度有机废水的处理提供了技术参考。  相似文献   

14.
Photo-Fenton-assisted ozonation of p-Coumaric acid in aqueous solution   总被引:1,自引:0,他引:1  
The degradation of p-Coumaric acid present in olive oil mill wastewater was investigated as a pretreatment stage to obtain more easily biodegradable molecules, with lower toxicity that facilitates subsequent anaerobic digestion. Thus, photo-Fenton-assisted ozonation has been studied and compared with ozonation at alkaline pH and conventional single ultraviolet (UV) and acid ozonation treatments. In the combined process, the overall kinetic rate constant was split into various components: direct oxidation by UV light, direct oxidation by ozone and oxidation by hydroxyl radicals. Molecular and/or radical ozone reaction was studied by conducting the reaction in the presence and absence of tert-butylalcohol at pHs 2, 7 and 9. Ozone oxidation rate increases with pH or by the addition of Fenton reagent and/or UV radiation due to generation of hydroxyl radicals, *OH. Hydrogen peroxide and ferrous ion play a double role during oxidation since at low concentrations they act as initiators of hydroxyl radicals but at high concentrations they act as radical scavengers. Finally, the additional levels of degradation by formation of hydroxyl radicals have been quantified in comparison to the conventional single processes and an equation is proposed for the reaction rate as a function of studied operating variables.  相似文献   

15.
Degradation of total phenol (TPh) and organic matter, (expressed as total organic carbon TOC), of a simulated olive mill wastewater was evaluated by the Fenton oxidation process under batch and continuous mode conditions. A mixture of six phenolic acids usually found in these agro-industrial wastewaters was used for this purpose. The study focused on the optimization of key operational parameters of the Fenton process in a batch reactor, namely Fe2+ dosage, hydrogen peroxide concentration, pH, and reaction temperature. On the assessment of the process efficiency, > 99% of TPh and > 56% of TOC removal were attained when [Fe2+] = 100 ppm, [H2O2] = 2.0 g/L, T = 30 °C, and initial pH = 5.0, after 300 min of reaction. Under those operational conditions, experiments on a continuous stirred-tank reactor (CSTR) were performed for different space-time values (τ). TOC and TPh removals of 47.5 and 96.9%, respectively, were reached at steady-state (for τ = 120 min). High removal of COD (> 75%) and BOD5 (> 70%) was achieved for both batch and CSTR optimum conditions; analysis of the BOD5/COD ratio also revealed an increase in the effluent’s biodegradability. Despite the high removal of lumped parameters, the treated effluent did not met the Portuguese legal limits for direct discharge of wastewaters into water bodies, which indicates that coupled chemical-biological process may be the best solution for real olive mill wastewater treatment.  相似文献   

16.
以橙黄II染料溶液为研究对象,通过正交实验确定了Fe-NTA/H2O2构成的类Fenton反应中各影响因子的最佳操作条件为:[H2O2]=20 mmol/L,[Fe-NTA]=2.5 mmol/L,pH=3。同时考察了反应时间、溶液pH值、H2O2浓度、Fe-NTA浓度对脱色效率的影响。实验表明脱色反应在30 m in内基本完成,类Fenton试剂能在较宽的pH范围内保持较好的脱色效果,而且在pH=6时,类Fenton试剂比传统Fenton试剂的脱色效率提高约75%。增加双氧水浓度可以提高橙黄II溶液脱色率,但超过20 mmol/L后效果提高不明显。在0.5~2.5 mmol/L的范围内,Fe-NTA浓度对脱色效果的影响不显著。  相似文献   

17.
This study investigated kaolin-supported nanoscale zero-valent iron (nZVI/K) as a heterogeneous Fenton-like catalyst for the adsorption and oxidation of an azo dye, Direct Black G (DBG). New findings suggest that kaolin as a support material not only reduced the aggregation of nanoscale zero-valent iron (nZVI) but also improved the adsorption of DBG. It consequently improved Fenton oxidation by increasing the local concentration of DBG in the vicinity of nZVI. This was confirmed by scanning electron microscopy and X-ray diffraction for the surface morphology of nZVI/K before and after the Fenton-like reaction. Furthermore, nZVI/K proved to be a catalyst for the heterogeneous Fenton-like oxidation of the DBG process in the neutral pH range. More than 87.22 % of DBG was degraded, and 54.60 % of total organic carbon was removed in the optimal conditions: 0.6 g/L dosage of nZVI/K, 33 mM H2O2, 100 mg/L initial DBG concentration, temperature of 303 K and pH of 7.06. Finally, it was demonstrated that nZVI/K removed DBG from dye wastewater through the processes of adsorption and oxidation.  相似文献   

18.
Oxidation of diethylene glycol with ozone and modified Fenton processes   总被引:5,自引:0,他引:5  
This paper describes a study of oxidation of diethylene glycol (DEG) by ozone and modified Fenton process (hydrogen peroxide and ferric salt mixture) in aqueous solution. Both oxidation processes were able to oxidize relatively high concentrations of DEG effectively. DEG reacted primarily through hydroxyl radical produced by decomposition of ozone, and about 3 mol of ozone were consumed per mole of DEG removed during the process. For modified Fenton oxidation, stepwise addition of hydrogen peroxide (H2O2) and ferric salt (Fe(III)) resulted in much higher removal of DEG than one-time pulse addition of the chemicals. The extent of DEG removal increased with increasing concentrations of both H2O2 and Fe(III). Oxidant consumption per mole of DEG oxidized was one order of magnitude higher for hydrogen peroxide than those observed for ozone. Overall, ozonation produced higher concentrations of aldehydes, and modified Fenton treatment produced higher concentrations of carboxylic acids for the same levels of DEG oxidation. The major products of ozonation were glycolaldehyde, glyoxal, formaldehyde, acetaldehyde, and acetic, formic, pyruvic, oxalic and glyoxalic acids. The major products of modified Fenton oxidation were formaldehyde, and formic and acetic acids.  相似文献   

19.
A soil contaminated with a B20 biodiesel blend (20 % biodiesel, 80 % diesel) has been treated by modified Fenton process with or without chelant addition. All experiments were conducted without pH adjustment. The reagents used were as follows: hydrogen peroxide as oxidant (400–4,000 mmol L?1), ferric ion as catalyst (5–20 mmol L?1), and trisodium citrate (50 mmol L?1) as chelating agent. Soil was spiked at two different pollutant concentrations (1,000–10,000 mg diesel kg?1 soil). Higher total petroleum hydrocarbon (TPH) removal efficiencies were obtained (up to 75 %) after the treatment in the absence of the chelant due to the low pH obtained in this case. In the presence of chelant, the TPH conversion obtained was lower because both higher pH is obtained and chelant competes with diesel for the oxidant. On the other hand, at neutral pH, the lifetime of the oxidant was increased. Fatty acid methyl esters (FAMEs) are easier to remove than diesel aliphatic hydrocarbons from the blend. An important decrease of the aqueous phase toxicity was observed after the modified Fenton reaction, supporting that nontoxic by-products were released to the aqueous phase during the treatment.  相似文献   

20.

Background, aim, scope

Treatment of wastewater has become significant with the declining water resources. The presence of recalcitrant organics is the major issue in meeting the pollution control board norms in India. The theme of the present investigation was on partial or complete removal of pollutants or their transformation into less toxic and more biodegradable products by heterogeneous Fenton oxidation process using mesoporous activated carbon (MAC) as the catalyst.

Materials and methods

Ferrous sulfate (FeSO4·7H2O), sulfuric acid (36?N, specific gravity 1.81, 98% purity), hydrogen peroxide (50% v/v) and all other chemicals used in this study were of analytical grade (Merck). Two reactors, each of height 50?cm and diameter 6?cm, were fabricated with PVC while one reactor was packed with MAC of mass 150?g and other without MAC served as control.

Results and discussion

The oxidation process was presented with kinetic and thermodynamic constants for the removal of COD, BOD, and TOC from the wastewater. The activation energy (Ea) for homogeneous and heterogeneous Fenton oxidation processes were 44.79 and 25.89?kJ/mol, respectively. The thermodynamic parameters ??G, ??H, and ??S were calculated for the oxidation processes using Van??t Hoff equation. Furthermore, the degradation of organics was confirmed through FTIR and UV?Cvisible spectroscopy, and cyclic voltammetry.

Conclusions

The heterocatalytic Fenton oxidation process efficiently increased the biodegradability index (BOD/COD) of the tannery effluent. The optimized conditions for the heterocatalytic Fenton oxidation of organics in tannery effluent were pH 3.5, reaction time?C4?h, and H2O2/FeSO4·7H2O in the molar ratio of 2:1.  相似文献   