首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
A recent development in analytical chemistry has enabled us to monitor systemic organophosphorus insecticide (OP) exposure at individual levels. At present, however, limited data are currently available on urinary OP metabolite levels worldwide. The purpose of this study was to assess urinary dialkylphosphate (DAP) concentrations in Japanese workers. Urine samples were collected in both summer and winter from 339 Japanese adults who worked as food distributors (FDs, n = 164), apple farmers (AFs, n = 147) and pest control operators (PCOs, n = 28). DAPs were measured by gas chromatography-mass spectrometry after derivatization with pentafluorobenzylbromide. Dimethylphosphate (DMP), diethylphosphate (DEP), dimethylthiophosphate (DMTP) and diethylthiophosphate (DETP) were detected in the urine of over 87% of the studied populations in both seasons. The geometric mean values of total DAPs (nmol g−1 creatinine), DMP, DMTP, DEP and DETP (μg g−1 creatinine) in summer and winter were 106.7 and 98.3, 7.0 and 3.8, 3.4 and 4.5, 0.8 and 1.5, and 0.3 and 0.2 for the FDs, 440.8 and 197.7, 33.1 and 10.8, 10.1 and 5.8, 4.2 and 4.7 and 1.6 and 0.8 for the AFs, and 473.4 and 284.6, 28.9 and 22.2, 17.6 and 4.6, 3.5 and 4.4, and 0.5 and 0.6 for the PCOs, respectively, thereby revealing significantly higher concentrations in AFs and PCOs groups than in the FDs in both seasons except for winter DMTP. These DAP concentrations were approximately the same or at lower levels compared with those reported in the previous literature. This is one of the first studies to demonstrate urinary DAP concentrations in Japanese adults.  相似文献   

2.
3.
Schenke D 《Chemosphere》2000,41(9):1313-1320
A residue analytical method was developed for the determination of the dialkylphosphate metabolites of parathion in faecal samples obtained from rabbits. The faecal pieces were homogenised in water and highly water-soluble O,O-diethyl phosphate (DEP) and O,O-diethyl thiophosphate (DETP) were subsequently alkylated to pentafluorobenzyl esters by a phase transfer reaction. Derivatisation yields depend on the reaction time. The recovery rates were determined over the complete procedure using authentic reference standards in matrix solution. The reference standards allow to observe an effect of the sample matrix on the area of signals while GC-FPD is used. The recoveries over the concentration range from 0.05 to 5 microg/g were 47-62% for O,O-diethyl phosphate and 92-106% for O,O-diethyl thiophosphate potassium salt with FPD.  相似文献   

4.
ABSTRACT

In this study, continuous data of PM10 (particles with aerodynamic diameter <10 u,m) concentration measurements for a 4-yr period were analyzed. These measurements have been carried out in the Eordea Basin, an industrial area in the northwestern mountainous region of Greece. The annual, monthly, and diurnal patterns are presented and investigated regarding the prevailing meteorological conditions and atmospheric processes that affect the ambient concentrations of PM10. The effect of wind on controlling PM10 concentration is also discussed. Based on the data analysis, an attempt is made to provide useful information about air quality levels, taking into account U.S. Environmental Protection Agency air quality standards.  相似文献   

5.
In this study, a two-dimensional liquid chromatography tandem mass spectrometry method was developed and validated for the determination of pesticide residues and contaminants in whole wheat grains and oats. The samples were extracted with a mixture of acetonitrile and water and were injected into the two-dimensional LC-MS/MS system without any further clean-up or sample preparation. Samples were analyzed with four different matrix matched calibrations. Matrix effects were evaluated by comparing analyte signals in the respective matrix matched standard with the neat solvent standards. The final method was validated according to the current Eurachem validation guide and SANTE document. The number of successfully validated analytes throughout all three validation levels in oats and wheat, respectively, were as follows: 330 and 316 out of 370 pesticides, 6 and 13 out of 18 pyrrolizidine alkaloids and 7 out of 9 regulated mycotoxins. Moreover, both plant growth regulators mepiquat and chlormequat as well as the tropane alkaloids atropine and scopolamine met the validation criteria. The majority of pesticides showed limits of detection below 1?µg kg?1, pyrrolizidine alkaloids below 0.7?µg kg?1, tropane alkaloids below 0.2?µg kg?1, growth regulators below 0.7?µg kg?1 and mycotoxins below 8?µg kg?1 in both matrices.  相似文献   

6.
In this study, continuous data of PM10 (particles with aerodynamic diameter < 10 microns) concentration measurements for a 4-yr period were analyzed. These measurements have been carried out in the Eordea Basin, an industrial area in the northwestern mountainous region of Greece. The annual, monthly, and diurnal patterns are presented and investigated regarding the prevailing meteorological conditions and atmospheric processes that affect the ambient concentrations of PM10. The effect of wind on controlling PM10 concentration is also discussed. Based on the data analysis, an attempt is made to provide useful information about air quality levels, taking into account U.S. Environmental Protection Agency air quality standards.  相似文献   

7.
Inorganic arsenic (InAs) is a ubiquitous metalloid that has been shown to exert multiple adverse health outcomes. Urinary InAs and its metabolite concentration has been used as a biomarker of arsenic (As) exposure in some epidemiological studies, however, quantitative relationship between daily InAs exposure and urinary InAs metabolites concentration has not been well characterized. We collected a set of 24-h duplicated diet and spot urine sample of the next morning of diet sampling from 20 male and 19 female subjects in Japan from August 2011 to October 2012. Concentrations of As species in duplicated diet and urine samples were determined by using liquid chromatography-ICP mass spectrometry with a hydride generation system. Sum of the concentrations of urinary InAs and methylarsonic acid (MMA) was used as a measure of InAs exposure. Daily dietary InAs exposure was estimated to be 0.087 µg kg?1 day?1 (Geometric mean, GM), and GM of urinary InAs+MMA concentrations was 3.5 ng mL?1. Analysis of covariance did not find gender-difference in regression coefficients as significant (P > 0.05). Regression equation Log 10 [urinary InAs+MMA concentration] = 0.570× Log 10 [dietary InAs exposure level per body weight] + 1.15 was obtained for whole data set. This equation would be valuable in converting urinary InAs concentration to daily InAs exposure, which will be important information in risk assessment.  相似文献   

8.
This study was undertaken to validate the “quick, easy, cheap, effective, rugged and safe” (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.  相似文献   

9.
Emission measurements of black carbon (BC) mass were conducted on a T63 turboshaft engine, operated at idle and cruise power with conventional and alternative fuels, using an Artium LII-300 laser-induced incandescence analyzer (LII) and AVL model 483 micro soot sensor (MSS) photoacoustic instrument using the manufacturer’s calibration for both instruments. These measurements were compared with elemental carbon (EC) determined by manual and semicontinuous thermal-optical transmission analyses according to National Institute for Occupational Safety and Health (NIOSH) method 5040 as the reference method. The results indicate that both the LII and MSS instruments show good linear correlation with EC for the two fuels and two engine power conditions evaluated. The LII measurements were observed to be biased high (27–49%) and the MSS measurements were biased low (24–35%) relative to EC. The agreement between the instruments and the reference method was substantially improved by applying a calibration of the instruments against a common BC aerosol source. Test data also suggest that the two instruments show some sensitivity to particle size (or properties related to size), specifically for particles with a geometric mean diameter (GMD) <30 nm. This sensitivity is problematic, since new engines or certain combustion conditions in current engines will produce smaller particles compared with the T63 model tested in this study. Further assessments of instrument performance for particles within this size range are therefore warranted.

Implications: Accurate black carbon emission measurements are needed to certify new and in-production commercial aircraft engines. Both the Artium LII-300 and AVL 483 micro soot sensor are currently approved by the International Civil Aviation Organization for this purpose. This study compares the two instruments against elemental carbon (EC) using NIOSH method 5040 as the reference using a T63 turboshaft engine. The results indicate that both instruments correlate reasonably well with EC, and the correlation substantially improved when applying a calibration against a common aerosol source. Sensitivity to particle size may be an issue for both instruments.  相似文献   


10.
Simple high-throughput procedures were developed for the direct analysis of glyphosate [N-(phosphonomethyl)glycine] and aminomethylphosphonic acid (AMPA) in human and bovine milk and human urine matrices. Samples were extracted with an acidified aqueous solution on a high-speed shaker. Stable isotope labeled internal standards were added with the extraction solvent to ensure accurate tracking and quantitation. An additional cleanup procedure using partitioning with methylene chloride was required for milk matrices to minimize the presence of matrix components that can impact the longevity of the analytical column. Both analytes were analyzed directly, without derivatization, by liquid chromatography tandem mass spectrometry using two separate precursor-to-product transitions that ensure and confirm the accuracy of the measured results. Method performance was evaluated during validation through a series of assessments that included linearity, accuracy, precision, selectivity, ionization effects and carryover. Limits of quantitation (LOQ) were determined to be 0.1 and 10 µg/L (ppb) for urine and milk, respectively, for both glyphosate and AMPA. Mean recoveries for all matrices were within 89–107% at three separate fortification levels including the LOQ. Precision for replicates was ≤7.4% relative standard deviation (RSD) for milk and ≤11.4% RSD for urine across all fortification levels. All human and bovine milk samples used for selectivity and ionization effects assessments were free of any detectable levels of glyphosate and AMPA. Some of the human urine samples contained trace levels of glyphosate and AMPA, which were background subtracted for accuracy assessments. Ionization effects testing showed no significant biases from the matrix. A successful independent external validation was conducted using the more complicated milk matrices to demonstrate method transferability.  相似文献   

11.
First-time measurements of the potentially toxic inorganic species of arsenic (arsenite arid arsenate) have been obtained in fine (<2.5 µm AD) and coarse (>2.5 µm AD) atmospheric particles in the Los Angeles area. A recently developed method that includes procedures for sample collection, preparation, and analysis was used in this study. Size-fractlonated aerosol samples were collected with a high-volume dichotomous virtual impactor that employed polytetrafluoroethylene filters. Results were obtained for the recovery of arsenic standards added to unexposed and collected filters. Data from this study, indicated that the recently developed speciation method can be used to determine concentrations of As(lll) and As(V) In atmospheric particulate matter samples.

Size-fractionated aerosol samples were collected in the city of Industry during January and February 1987. In most samples, As(lll) and As( V) were above the detection limit (approximately 1 ng m-3 of either species) in both aerosol size fractions. A greater portion (about 75 percent) of the two species were observed in the fine particles. The As(lll)/As(V) ratio for both particle sizes was close to 1 (I.e., an equal mixture of both species). Comparison of total suspended particulate arsenic measured by the speciation method to that measured by a routine California Air Resources Board-approved procedure showed good agreement (r = 0.94), indicating both methods were approximately equivalent for the collection and analysis of aerosol arsenic.  相似文献   

12.
Abstract

The absolute accuracy and long‐term precision of atmospheric measurements hinge on the quality of the instrumentation and calibration standards. To assess the consistency of the ozone (O3) and nitrogen oxides (NOx) standards maintained at the National Institute of Standards and Technology (NIST), these standards were compared through the gas‐phase titration of O3 with nitric oxide (NO). NO and O3 were monitored using chemiluminescence and UV absorption, respectively. Nitrogen dioxide (NO2) was monitored directly by laser‐induced fluorescence and indirectly by catalytic conversion to NO, followed by chemiluminescence. The observed equivalent loss of both NO and O3 and the formation of NO2 in these experiments was within 1% on average over the range of 40–200 nmol mol?1 of NO in excess O3, indicating that these instruments, when calibrated with the NIST O3 and NO standards and the NO2 permeation calibration system, are consistent to within 1% at tropospherically relevant mixing ratios of O3. Experiments conducted at higher initial NO mixing ratios or in excess NO are not in as good agreement. The largest discrepancies are associated with the chemiluminescence measurements. These results indicate the presence of systematic biases under these specific conditions. Prospects for improving these experiments are discussed.  相似文献   

13.
The use of iridium in the latest catalytic converters to further reduce nitrogen oxide emission in the exhaust of lean-burn engines could result in increased atmospheric levels of this element in high-density vehicle traffic areas. The objective of this study is to assess environmental Ir pollution and its urinary levels in workers and an urban control group. Environmental monitoring inside a tram consisted in air samplings of total suspended particles (TSP), PM10 and PM2.5 carried out during November 2005. Urinary Ir levels were evaluated in 64 municipal tram drivers and in 58 administrative employees as controls. Quantification of Ir in air samples and urine was performed by means of Sector Field Inductively Coupled Plasma Mass Spectrometry. Means+/-standard deviation of Ir levels in TSP, in PM10 and PM2.5 fractions were 1.43+/-1.66, 0.44+/-0.27 and 0.36+/-0.19 pg m(-3), respectively. No statistically significant differences were observed among urinary Ir values in the exposed subjects and control group. The Ir levels in Rome air are still sufficiently low, even if the increased use of new Ir-based catalysts could be of some concern in the near future. The results of our study are of interest as they are a first attempt to explore airborne levels and urinary concentrations of Ir in an urban context at medium-high density of vehicle traffic. Particular attention should be given to the fact that Ir was found in the finest dust particles as the effects of fine particles containing Ir have not yet been studied.  相似文献   

14.
This paper is directed to people who are involved in the measurement of gas turbine exhaust emissions and as a consequence in the establishment of standard reference gases and attendant analytical procedures.

Several problems exist in connection with the establishment of these standards:

A number of standard reference gases have been developed by the National Bureau of Standards for use in the automotive industry which are also suitable for gas turbine exhaust measurements. However, there is a need for additional standard reference materials such as NO in nitrogen, intermediate levels of CO2 in air, and higher concentrations of CO in nitrogen and propane in air.

There is difficulty in maintaining certain reference materials with confidence in assay, particularly due to instability in the cylinder.

Instrumental operational problems with flame ionization detector type units exist. Of particular importance is the difference in response per carbon atom in different organic molecules and the difference in response of a test sample as a function of the oxygen content of the sample.

Instrumental method problems such as converter efficiency in chemiluminescence units measuring NO2 and calibration techniques involving CO to CH4 conversion, also must be considered.

A number of problems occur in the use of wet chemical reference methods such as the phenoldisulfonic acid method for the determination of NOx. These include both efficiency of collection, conversion of NO to NO2, and subsequent analysis.

This paper considers the development of standards for the measurement of NOx, CO, CO2, total hydrocarbons, and O2 and reviews the state-of-the-art with respect to these problems and their resolution.  相似文献   

15.
Electron microscopy-energy dispersive spectroscopy (EM/EDS) can be used to determine the elemental composition of individual particles. However, the accuracy with which atmospheric particle compositions can be quantitatively determined is not well understood. In this work we explore sources of sampling and analytical bias and methods of reducing bias. Sulfuric acid [H2SO4] and ammonium sulfate [(NH4)2SO4] particles were collected on beryllium, silicon, and carbon substrates with similar deposition densities. While [(NH4)2SO4] particles were observed on all substrates, [H2SO4] and ammonia-treated [H2SO4] particles could not be found on beryllium substrates. Interactions between the substrate and sulfuric acid particles are implicated. When measured with EM/EDS, [H2SO4] particles exposed to ammonia overnight were found having lower beam damage rates (0.000 ± 0.002 fraction s−1) than those without any treatment (0.023 ± 0.006 fraction s−1) For laboratory-generated [C10H6(SO3Na)2] particles, the composition determined using the experimental k-factors evaluated from independent particle standards of similar composition and size shows an error less than 20% for all constituents, while greater than 78% errors were found when k-factors were calculated from the theory. This study suggests (1) that sulfate beam damage can be reduced by exposure of atmospheric particle samples to ammonia before analysis, (2) that beryllium is not a suitable substrate for atmospheric particle analysis, and (3) calibration (k-factor determination) using particle standards of similar size and composition to particles present in the atmosphere shows promise as a way of improving the accuracy of quantitative EM analysis.  相似文献   

16.
Di-n-pentyl phthalate (DPP) is used mainly as a plasticizer in nitrocellulose. At high doses, DPP acts as a potent testicular toxicant in rats. We administered a single oral dose of 500 mg kg−1 bw of DPP to adult female Sprague-Dawley rats (N = 9) and collected 24-h urine samples 1 d before and 24- and 48-h after DPP was administered to tentatively identify DPP metabolites that could be used as exposure biomarkers. At necropsy, 48 h after dosing, we also collected serum. The metabolites were extracted from urine or serum, resolved with high performance liquid chromatography, and detected by mass spectrometry. Two DPP metabolites, phthalic acid (PA) and mono(3-carboxypropyl) phthalate (MCPP), were identified by using authentic standards, whereas mono-n-pentyl phthalate (MPP), mono(4-oxopentyl) phthalate (MOPP), mono(4-hydroxypentyl) phthalate (MHPP), mono(4-carboxybutyl) phthalate (MCBP), mono(2-carboxyethyl) phthalate (MCEP), and mono-n-pentenyl phthalate (MPeP) were identified based on their full scan mass spectrometric fragmentation pattern. The ω − 1 oxidation product, MHPP, was the predominant urinary metabolite of DPP. The median urinary concentrations (μg mL−1) of the metabolites in the first 24 h urine collection after DPP administration were 993 (MHPP), 168 (MCBP), 0.2 (MCEP), 222 (MPP), 47 (MOPP), 26 (PA), 16 (MPeP), and 9 (MCPP); the concentrations of metabolites in the second 24 h urine collection after DPP administration were significantly lower than in the first collection. We identified some urinary metabolic products in the serum, but at much lower levels than in urine. Because of the similarities in metabolism of phthalates between rats and humans, based on our results and the fact that MHPP can only be formed from the metabolism of DPP, MHPP would be the most adequate DPP exposure biomarker for human exposure assessment. Nonetheless, based on the urinary levels of MHPP, our preliminary data suggest that human exposure to DPP in the United States is rather limited.  相似文献   

17.
Abstract

The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.  相似文献   

18.
Numerous chemical products are dispersed into the environment, and the consequences can be sometimes harmful to humans and ecosystems. Pharmaceutical compounds and hormone steroids are among these substances that concern the scientific community. Currently, little data are available on the presence and fate of these compounds in the environment and, in particular, for solid matrices. Therefore, the aim of this work was to perform soil column experiments to evaluate the accumulation, transfer and degradation of these substances in soil. The analyses were based on efficient sample preparation followed by sensitive and selective liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). For this purpose, 23 compounds were chosen including both pharmaceutical compounds as well as steroid hormones. In addition, this experiment was performed on two soils with different properties (% clay, pH, etc.). To the best of our knowledge, no soil column experiments have been performed previously on a large number of pharmaceutical compounds and steroid hormones. Significant transfer was observed only for sulphonamides that can be justified by their polarity (log K ow ?相似文献   

19.
Abstract

Pesticides containing copper are used on wide range in vegetable production, especially in the open field. Copper has an excellent fungicidal effect against diseases of tomato, pepper, onion and in practical use it is essential as bactericide in the above mentioned crops.

The fungicides containing copper are freely available on the market, they are not expensive and widely used without any special knowledge. They are popular in simple home gardens as well as in hi‐tech vegetable production and are used even in all forms of “bio”; culture.

From the other side, copper can be toxic. The allowable level is 10 mg Cu/kg product. This concentration may be found after the first treatment and it increases after every further application.

In our experiments the copper absorbancy and accumulation has been investigated at different pesticide doses and under different experimental conditions.

The analytical measurements, the sample preparation, the instrument calibration have been made by the Inductively Coupled Plasma Spectrometer at the Department of Chemistry of the University of Horticulture and Food Industry.  相似文献   

20.
The use of isotope-labeled internal standards is the most widely accepted approach to overcome the matrix effects on quantification of pesticides in food by LC/MS. We evaluated the impact of the matrix effects on quantification of six neonicotinoid pesticides, acetamiprid, clothianidin, dinotefuran, imidacloprid, thiacloprid, and thiamethoxam, in food by using deuterated internal standards. The calibration curves for each pesticide were obtained by using matrix-free and matrix-matched calibration solutions with blank brown rice, carrot, and green onion extracts. For brown rice and carrot, the matrix effects were not observed. In contrast, the slopes of calibration curves for each pesticide were influenced by presence of green onion extracts in calibration solutions (variability of the slopes was 4–9%), because the ratios of peak area for native pesticide to those for internal standards were influenced by matrix. The spike-and-recovery test with green onion was also performed. The analytical values obtained by using matrix-free calibration solution were biased from the spiked concentration, whereas those obtained by using matrix-matched calibration solution were comparable to the spiked concentration. These results indicate that matrix-matched calibration solution should be used for accurate quantification of neonicotinoid pesticides in food by LC/MS using deuterated internal standards.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号