首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Fly ash and sewage sludge are suggested materials for constructing sealing layers covering mine tailings impoundments. Little is known, however, of their effect on vegetation or resistance to root penetration. We investigate: (i) the ability of different plant species to grow in sealing layers comprising fly ash and sewage sludge, (ii) the impact on plant growth of freshly hardened fly ash compared to aged and leached ash, and (iii) the plant stress response to fly ashes of different properties. A 6-mo greenhouse study using birch (Betula pendula Roth.), Scots pine (Pinus sylvestris L.), Kentucky bluegrass (Poa pratensis L.), and willow (Salix viminalis L.) demonstrated that no roots could grow into a compacted layer consisting only of ash, while a 6:4, ash-sludge mixture admitted roots into the upper part and a 1:9, ash-sludge mixture was totally penetrated (to 15 cm in depth) by roots of willow and Scots pine. Freshly hardened ash prevented root growth more effectively than aged ash did, as was observed in tests using reed canarygrass (Phalaris arundinacea L.) and pea (Pisum sativum L.). Furthermore, extracts of highly alkaline ash were more toxic to pea in a 48-h toxicity test than less alkaline ash was. However, stress responses to diluted ash extracts of lower pH, measured as enzyme capacities in dwarf bean (Phaseolus vulgaris L.), were more related to the metal and ion contents. Root penetration of sealing layers is most effectively prevented if little sewage sludge is added, and if ash of high alkalinity is chosen.  相似文献   

2.
In the investigation of soil cover design options for final decommissioning of reactive mine waste, it is often necessary to analyze or predict the anticipated cover performance as a function of the cost of implementation, which is governed by the type, number and thickness of the layers in the cover system. An example of such investigation is presented in this study where one-dimensional evaporation from hypothetical moisture-retaining cover systems is simulated to assess the influence of several cover properties and hydrogeologic parameters on performance. The commercially available transient flow model, SoilCover, was used to compute suction and water content profiles for different cover design scenarios. The predicted water content profile and porosity of layers were then used to estimate the oxygen diffusion coefficients of the various layers. The oxygen diffusion coefficients were used to estimate oxygen flux through the cover systems. The oxygen flux was, in turn, related to the maximum acid flux. The studied cover and hydrogeologic parameters included soil type, thickness of barriers, and water table elevation. Two types of infiltration and oxygen barrier and two types of capillary layer with different thicknesses were studied. The water table was either kept constant at the base of the waste (tailings) or dropped by 0.5, 1, 2, and 3m over 120 days. The results showed that the relationship between water table depression and the thickness of capillary layers, on one hand, and desaturation of the infiltration and oxygen barrier, on the other, is not linear. Relationships between oxygen flux and barrier thickness and between cost increase and performance improvement of the studied cover systems are presented. Finally, a method that outlines steps for site-specific and economically feasible design of multi-layer cover systems is introduced.  相似文献   

3.
The denitrification process and nitrous oxide (N2O) production in the soil profile are poorly documented because most research into denitrification has concentrated on the upper soil layer (0-0.15 m). This study, undertaken during the 1999 and 2000 growing seasons, was designed to examine the effects of water table management (WTM), nitrogen (N) application rate, and depth (0.15, 0.30, and 0.45 m) on soil denitrification end-products (N2O and N2) from a corn (Zea mays L.) field. Water table management treatments were free drainage (FD) with open drains and subirrigation (SI) with a target water table depth of 0.6 m. Fertility treatments (ammonium nitrate) were 120 kg N ha(-1) (N120) and 200 kg N ha(-1) (N200). During both growing seasons greater denitrification rates were measured in SI than in FD, particularly in the surface soil (0-0.15 m) and at the intermediate (0.15-0.30 m) soil depths under N200 treatment. Greater denitrification rates under the SI treatment, however, were not accompanied with greater N2O production. The decrease in N2O production under SI was probably caused by a more complete reduction of N2O to N2, which resulted in lower N2O to (N2O + N2) ratios. Denitrification rate, N2O production and N2O to (N2O + N2) ratios were only minimally affected by N treatments, irrespective of sampling date and soil depth. Overall, half of the denitrification occurred at the 0.15- to 0.30- and 0.30- to 0.45-m soil layers, and under SI, regardless of fertility treatment level. Consequently, sampling of the 0- to 0.15-m soil layer alone may not give an accurate estimation of denitrification losses under SI practice.  相似文献   

4.
The interpretation of ten resistivity curves in Obiaruku and environs indicates that the area has a great groundwater potential. Correlation of the curves with the lithologic log from a nearby borehole in Ghana quarters, reveals the lithologic succession as an extensive sandy unit between the range of 20 m and 136 m. The medium grained sand unit, which is the aquiferous zone, has a resistivity range of between 300 Ω m and 600 Ω m. The result of the interpreted data and the lithologic log from the borehole indicates three to five geoelectric layers except at Adonishaka, which has a confined aquifer in the third layer and Umukwata that has a confined aquifer in the second layer, the study area generally has an unconfined aquifer, which is in the second layer. In the event of pollution, the groundwater may be contaminated. Sinking of water borehole is not recommended in these areas. Boreholes for potable water are therefore recommended at locations within Adonishaka and Umukwata areas. The present study acts as a guide for future groundwater exploration and exploitation.  相似文献   

5.
There may be important biological sources of polycyclic aromatic hydrocarbons (PAHs) to the global environment, particularly of naphthalene, phenanthrene, and perylene, that originate in the tropics. We (i) studied the distribution of PAHs among different compartments of a typical Cerrado to locate their sources and (ii) quantified the PAH storage of this ecosystem. The sum of 20 PAH (sigma20PAHs) concentrations ranged from 25 to 666 microg kg(-1) in plant tissue, 7.4 to 32 microg kg(-1) in litterfall, 206 to 287 microg kg(-1) in organic soil, and 10 to 79 microg kg(-1) in mineral soil. Among the living biomass compartments, the bark had the highest mean PAH concentrations and coarse roots the lowest, indicating that PAHs in the plants originated mainly from aboveground sources. Naphthalene and phenanthrene were the most abundant individual PAHs, together contributing 33 to 96% to the sigma20PAHs concentrations. The total storage of the X20PAHs in Cerrado was 7.5 mg m(-2) to a 0.15-m soil depth and 49 mg m(-2) to a 2-m soil depth. If extrapolated to the entire Brazilian Cerrado region, roughly estimated storages of naphthalene and phenanthrene correspond to 7300 and 400 yr of the published annual emissions in the United Kingdom, respectively. The storage of benzo[a]pyrene, a typical marker for fossil fuel combustion, in the Cerrado only corresponds to 0.19 yr of UK emissions. These results indicate that the Brazilian savanna comprises a huge reservoir of naphthalene and phenanthrene originating most likely from the aboveground parts of the vegetation or associated organisms. Thus, the Cerrado might be a globally important source of these PAHs.  相似文献   

6.
Fate of applied N in forage-based agricultural systems is important to long-term production and environmental impacts. We evaluated the factorial combination of N fertilization targeted to supply 20 g N m 2 yr(-1) and harvest strategies on soil-profile inorganic N during the first 5 yr of 'Coastal' bermudagrass [Cynodon dactylon (L.) Pers.] management. Harvest strategy had much larger effects than fertilization strategy, most notably that soil-profile inorganic N was lower when hayed than under other systems. In the upper rooting zone (0- to 0.3-m depth), soil inorganic N (initially at 3.1 g m(-2)) remained unchanged during the 5 yr under unharvested and low and high grazing pressures (0.00 +/- 0.08 g m(-2) yr(-1)), but declined with haying (-0.25 g m(-2) yr(-1)). In the lower rooting zone (0.3- to 0.9-m depth), soil inorganic N (initially at 2.9 g m(-2)) accumulated with unharvested and low and high grazing pressure (0.64 +/- 0.20 g m(-2) yr(-1)), but remained unchanged with haying (-0.06 g m(-2) yr(-1)). Below the rooting zone (0.9- to 1.5-m depth), soil inorganic N (initially at 5.8 g m(-2)) increased with unharvested and high grazing pressure (0.34 +/- 0.03 g m(-2) yr(-1)), was unchanged with low grazing pressure (-0.10 g m(-2) yr(-1)), and declined with haying (-0.50 g m(-2) yr(-1)). Applied N appears to have been efficiently utilized by forage with subsequent sequestration into soil organic matter and little movement of inorganic N below the rooting zone (< 2% of applied N), irrespective of inorganic or organic fertilization strategy designed to supply sufficient N for high animal production from grazing.  相似文献   

7.
The selection of plant species is critical for the successful establishment and long-term maintenance of vegetation on reclaimed surface mined soils. A study was conducted to assess the capability of 16 forage grass and legume species in monocultures and mixes to establish and thrive on a reclaimed Appalachian surface mine amended with biosolids. The 0.15-ha coarse-textured, rocky, non-acid forming mined site was prepared for planting by grading to a 2% slope and amending sandstone overburden materials with a mixture of composted and dewatered, anaerobically digested biosolids at a rate of 368 Mg ha(-1) (dry weight). Tall fescue (Festuca arundinacea Schreb.), orchardgrass (Dactylis glomerata L.), switchgrass (Panicum virgatum L.), caucasian bluestem (Bothriochloa caucasia L.), reed canarygrass (Phalaris arundinacea L.), ladino clover (Trifolium repens L.), birdsfoot trefoil (Lotus corniculatus L.), crownvetch (Coronilla varia L.), alfalfa (Medicago sativa L.), common sericea lespedeza and AULotan sericea lespedeza (Lespedeza cuneata L.), tall fescue-ladino clover, tall fescue-alfalfa, orchardgrass-birdsfoot trefoil, switchgrass-AULotan, and an herbaceous species mix intended for planting on reforested sites consisting of foxtail millet [Setaria italica (L.) Beauv.], perennial ryegrass (Lolium perenne L.), redtop (Agrostis alba L.), kobe lespedeza (Kummerowia striata L.), appalow lespedeza (Lespedeza cuneata L.), and birdsfoot trefoil were established between spring 1990 and 1991. Vegetative biomass and/or persistence were assessed in 1996, 1997, 1998, 2000, 2001, and 2002. The high rate of biosolids applied provided favorable soil chemical properties but could not overcome physical property limitations due to shallow undeveloped soil perched atop a compacted soil layer at 25 cm depth. The plant species whose persistence and biomass production were the greatest after a decade or more of establishment (i.e., switchgrass, sericea lespedeza, reed canarygrass, tall fescue, and crownvetch) shared the physiological and reproductive characteristics of low fertility requirements, drought and moisture tolerance, and propagation by rhizome and/or stolons. Of these five species, two (tall fescue and sericea lespedeza) are or have been seeded commonly on Appalachian coal surface mines, and often dominate abandoned pasture sites. Despite the high rates of heavy metal-bearing biosolids applied to the soil, plant uptake of Cd, Cu, Ni, and Zn were well within critical concentrations more than a decade after establishment of the vegetation.  相似文献   

8.
A passive flat-plate solar air collector was constructed in the laboratory of New and Renewable Energy in Arid Zones, Ouargla University, South East Algeria. The absorber of the passive flat-plate solar air collector was laminated with a thin layer of local sand. This acted as a thermal packed bed with a collecting area of 0.5 m2 (1 m × 0.5 m). Three series of experiments were performed. The first consisted of choosing the best sand brought from three different places of the Algerian desert. The second consisted of studying the effect of the thickness of the sand layer on the daily efficacy of the collector. The influence of the sand diameter was investigated in the third series. The experimental results showed that: All collectors covered with sand had higher efficiency than those without. It was noticed that, for a fixed mass of sand (given thickness of the sand layer), the improvement of the collector was inversely proportional to the sand particle diameters. The maximum efficiency approximates 62.1% for a particle diameter 0.063 mm, compared to 41.71% for a diameter 0.250 mm.The efficiency of the collector for a fixed particle diameter increases with the increase in the thickness of the sand layer. The collector with thickness sand layer 0.84 mm gave the best efficiency of 46.14% compared to 27.8% for 0.28 mm of thickness sand layer.  相似文献   

9.
This study examined bacteria and nutrient quality in tile drainage and shallow ground water resulting from a fall land application of liquid municipal biosolids (LMB), at field application rates of 93,500 L ha(-1), to silt-clay loam agricultural field plots using two different land application approaches. The land application methods were a one-pass AerWay SSD approach (A), and surface spreading plus subsequent incorporation (SS). For both treatments, it took between 3 and 39 min for LMB to reach tile drains after land application. The A treatment significantly (p < 0.1) reduced application-induced LMB contamination of tile drains relative to the SS treatment, as shown by mass loads of total Kjeldahl N (TKN), NH(4)-N, Total P (TP), PO(4)-P, E. coli., and Clostridium perfringens. E. coli contamination resulting from application occurred to at least 2.0-m depth in ground water, but was more notable in ground water immediately beneath tile depth (1.2 m). Treatment ground water concentrations of selected nutrients and bacteria for the study period ( approximately 46 d) at 1.2-m depth were significantly higher in the treatment plots, relative to control plots. The TKN and TP ground water concentrations at 1.2-m depth were significantly (p < 0.1) higher for the SS treatment, relative to the A treatment, but there were no significant (p > 0.1) treatment differences for the bacteria. For the macroporous field conditions observed, pre-tillage by equipment such as the AerWay SSD, will reduce LMB-induced tile and shallow ground water contamination compared to surface spreading over non-tilled soil, followed by incorporation.  相似文献   

10.
Leaching to ground water and tile drains are important parts of the environmental assessment of pesticides. The aims of the present study were to (i) assess the significance of preferential flow for pesticide leaching under realistic worst-case conditions for Dutch agriculture (soil profile with thick clay layer and high rainfall) and (ii) collect a high-quality data set that is suitable for testing pesticide leaching models. The movement of water, bromide, and the pesticides bentazon [3-isopropyl-1H-2, 1,3-benzothiadiazine-4(3H)-one-2,2-dioxide] and imidacloprid [1-[(6-chloro-3-pyridinyl)-methyl]-N-nitro-2-imidazolidinimine] was monitored in a clay soil for about 1 yr. The 1.2-ha field was located in the central part of the Netherlands (51 degrees 53' N, 5 degrees 43' E). The soil was a Eutric Fluvisol cropped with winter wheat (Triticum aestivum L.). Tile drains were present at a 0.8- to 0.9-m depth and the ground water level fluctuated between a 0.5- and 2-m depth. All chemicals were applied in spring. None of the soil concentration profiles showed bimodal concentration distributions. However, for each substance the highest concentration in drain water was found in the first drainage event after its application, which indicates preferential flow. This preferential flow is probably caused by permanent macropores that were present in the 0.3- to 1.0-m layer. At the time of the first drainage event, the drain water concentration of each substance was about an order of magnitude higher than its ground water concentration. Thus, the flux concentrations in drain water proved to be a more sensitive detector of preferential flow than the resident concentrations in the soil profile and the ground water.  相似文献   

11.
Current Irish guidelines require a comprehensive site assessment of a percolation area for wastewater disposal before planning permission is granted for dwellings in rural areas. For a site to be deemed suitable, the subsoil must have a percolation value equivalent to a field saturated hydraulic conductivity in the range 0.08 to 4.2 m d(-1) using a falling head percolation test. A minimum of 1.2 m of unsaturated subsoil must also exist below the invert of the percolation area receiving effluent from a septic tank (or 0.6 m for secondary treated effluent). During a 2-yr period, the three-dimensional performance of four percolation areas treating domestic wastewater was monitored. At each site samples were taken at 0, 10, and 20 m along each of the four percolation trenches at depths of 0.3, 0.6, and 1.0 m below each trench to ascertain the attenuation effects of the unsaturated subsoil. The two sites with septic tanks installed performed at least as well as the other two sites with secondary treatment systems installed and appeared to discharge a better quality effluent in terms of nutrient load. An average of 2.1 and 6.8 g total N d(-1) remained after passing through 1-m depth of subsoil beneath the trenches receiving septic tank effluent compared with 12.7 and 16.7 g total N d(-1) on the sites receiving secondary effluent. The research also indicates that the septic tank effluent was of an equivalent quality to the secondary treated effluent in terms of indicator bacteria (E. coli) after percolating through 0.6-m depth of unsaturated subsoil.  相似文献   

12.
Landfill sites are potential sources of hazardous emissions by degradation and transformation processes of waste organic matter. Its chemical composition and microbial degradability are key factors for risk management, after-care, and estimation of potential emissions. The aim of the study is to provide information about composition and extent of transformation of waste organic matter in four landfill sites in Bavaria, Southern Germany by means of (13)C NMR spectroscopy, acid-hydrolyzable carbohydrates, chloroform-methanol extractable lipids, acid-hydrolyzable proteins, and lignin compounds after CuO oxidation. Ten samples of about 20 to 25 yr, 15 to 20 yr, and 5 to 10 yr of deposition each were taken at 2 m depth intervals by grab drilling till 10-m depth. Increasing temperatures from about 15 degrees C at 2-m depth to >40 degrees C at 10-m depth are found at some of the sites, representing optimum conditions for mesophile methane bacteria. Moisture contents of 160 to 310 g kg(-1) (oven dry), however, provide limiting conditions for anaerobic biodecay. Spectroscopic and chemical variables generally indicate a low extent of biodegradation and transformation at all sites despite a considerable heterogeneity of the samples. Independent of the time and depth of deposition more than 50% of the carbohydrate fraction of the waste organic matter provide a high potential for methane emissions and on-site energy production. There was no significant accumulation of long-chain organic and aromatic compounds, and of lignin degradation products even after more than 25 yr of rotting indicating higher extent of decomposition or stabilization of the waste organic matter. Installation of seepage water cleaning and recirculation systems are recommended to increase suboptimal moisture contents with respect to microbial methanogenesis, energy production, and long-term stabilization of municipal solid waste.  相似文献   

13.
ABSTRACT: Twenty-six aspen (Populus tremuloides Michx.), 20 subalpine fir (Abies lasiocarps (Hook.) Nutt.), and 20 Engelmann spruce (Pices engelmanil (Parry) Engelm.) of various sizes were cut under water and suspended in permanent reserviors at a northern Utah site. The reservoirs were asealed so that all water loss was due to consumption by the trees. Sap velocities, as computed from heat pulse velocities, were related to conducting areas of the tree trunks. Computed transpiration volumes were then correlated with actual water losses from the reservoirs. Coefficients of determination (R2) of 0.87, 0.86, and 0.82 were obtained for the fir, aspen, and sprucs, respectively. Reservoir water loss for each species for each season was then used to adjust a plant activity index for computing transpiration within ASPCON, a model describing the hydrology of aspen to conifer succession. The plant activity index reflects the variation in the capability of a plant community to transpire water over the year. Assumptions and limitations of the heat pulse velocity technique are also outlined.  相似文献   

14.
Global land use patterns and increasing pressures on water resources demand creative urban stormwater management. Strategies encouraging infiltration can enhance groundwater recharge and water quality. Urban subsoils are often relatively impermeable, and the construction of many stormwater detention best management practices (D-BMPs) exacerbates this condition. Root paths can act as conduits for water, but this function has not been demonstrated for stormwater BMPs where standing water and dense subsoils create a unique environment. We examined whether tree roots can penetrate compacted subsoils and increase infiltration rates in the context of a novel infiltration BMP (I-BMP). Black oak (Quercus velutina Lam.) and red maple (Acer rubrum L.) trees, and an unplanted control, were installed in cylindrical planting sleeves surrounded by clay loam soil at two compaction levels (bulk density = 1.3 or 1.6 g cm(-3)) in irrigated containers. Roots of both species penetrated the more compacted soil, increasing infiltration rates by an average of 153%. Similarly, green ash (Fraxinus pennsylvanica Marsh.) trees were grown in CUSoil (Amereq Corp., New York) separated from compacted clay loam subsoil (1.6 g cm(-3)) by a geotextile. A drain hole at mid depth in the CUSoil layer mimicked the overflow drain in a stormwater I-BMP thus allowing water to pool above the subsoil. Roots penetrated the geotextile and subsoil and increased average infiltration rate 27-fold compared to unplanted controls. Although high water tables may limit tree rooting depth, some species may be effective tools for increasing water infiltration and enhancing groundwater recharge in this and other I-BMPs (e.g., raingardens and bioswales).  相似文献   

15.
Phylloscopus trochilus ), crossbills (Loxia spp.), and tree pipit (Anthus trivialis). The composition of the bird community did not vary significantly between the compared transects. Some species appeared to favour road–forest edges but this could not be confirmed with our data. These species were not the same as have been reported to favor clear-fellings–mature forest edges. Therefore, the edge effect does not seem to be the most important factor controlling relative bird densities immediately adjacent and further away from highways. The likelihood of avoiding the problems the highways are causing for bird density are been discussed.  相似文献   

16.
Silvopastoral management of fast-growing tree plantations is becoming popular in the Brazilian Cerrado (savanna). To understand the influence of such systems on soil carbon (C) storage, we studied C content in three aggregate size classes in six land-use systems (LUS) on Oxisols in Minas Gerais, Brazil. The systems were a native forest, a treeless pasture, 24- and 4-yr-old eucalyptus ( sp.) plantations, and 15- and 4-yr-old silvopastures of fodder grass plus animals under eucalyptus. From each system, replicated soil samples were collected from four depths (0-10, 10-20, 20-50, and 50-100 cm), fractionated into 2000- to 250-, 250- to 53-, and <53-μm size classes representing macroaggregates, microaggregates, and silt + clay, respectively, and their C contents determined. Macroaggregate was the predominant size fraction under all LUS, especially in the surface soil layers of tree-based systems. In general, C concentrations (g kg soil) in the different aggregate size fractions did not vary within the same depth. The soil organic carbon (SOC) stock (Mg C ha) to 1-m depth was highest under pasture compared with other LUS owing to its higher soil bulk density. The soils under all LUS had higher C stock compared with other reported values for managed tropical ecosystems: down to 1 m, total SOC stock values ranged from 461 Mg ha under pasture to 393 Mg ha under old eucalyptus. Considering the possibility for formation and retention of microaggregates within macroggregates in low management-intensive systems such as silvopasture, the macroaggregate dynamics in the soil seem to be a good indicator of its C storage potential.  相似文献   

17.
/ This paper presents an approach for producing aquifer sensitivity maps from three-dimensional geologic maps, called stack-unit maps. Stack-unit maps depict the succession of geologic materials to a given depth, and aquifer sensitivity maps interpret the successions according totheir ability to transmit potential contaminants. Using McHenry County, Illinois, as a case study, stack-unit maps and an aquifer sensitivity assessment were made to help land-use planners, public health officials, consultants, developers, and the public make informed decisions regarding land use. A map of aquifer sensitivity is important for planning because the county is one of the fastest growing counties in the nation, and highly vulnerable sand and gravel aquifers occur within 6 m of ground surface over 75% of its area. The aquifer sensitivity map can provide guidance to regulators seeking optimal protection of groundwater resources where these resources are particularly vulnerable. In addition, the map can be used to help officials direct waste-disposal and industrial facilities and other sensitive land-use practices to areas where the least damage is likely to occur, thereby reducing potential future liabilities. KEY WORDS: Geologic mapping; Groundwater; Aquifers; Aquifer sensitivity; Land-use planning  相似文献   

18.
Nitrogen removal in laboratory model leachfields with organic-rich layers   总被引:1,自引:0,他引:1  
Septic system leachfields can release dissolved nitrogen in the form of nitrate into ground water, presenting a significant source of pollution. Low cost, passive modifications, which increase N removal in traditional leachfields, could substantially reduce the overall impact on ground water resources. Bench-scale laboratory models were constructed to evaluate the effect of placing an organic layer below the leachfield on total N removal. The organic layer provides a carbon source for denitrification. Column units representing septic leachfields were constructed with sawdust-native soil organic layers placed 0.45 m below the influent line and with thicknesses of 0.0, 0.3, 0.6, and 0.9 m. Using a synthetic septic tank effluent, NO(3)-N concentrations at 3.8 m below the influent line were consistently below 1 mg L(-1) during 10 months of operation compared with a NO(3)-N concentration of nearly 12 mg L(-1) in the control column. The average total N removal increased from 31% without the organic layer to 67% with the organic layer. Total N removal appeared limited by the extent of organic N oxidation and nitrification in the 0.45-m aerobic zone. Design modifications targeted at improving nitrification above the organic layer may further increase total N removal. Increased organic layer thicknesses from 0.3 m to 0.9 m did not significantly improve average total N removal, but caused a shift in residual nitrogen from organic N to ammonia N. Results indicate that addition of a layer of carbon source material at least 0.3 m thick below a standard leachfield substantially improves total N removal.  相似文献   

19.
In many locations, regulatory agencies do not permit tree planting above landfills that are sealed with a capping clay, because roots might penetrate the clay barrier and expose landfill contents to leaching. We find, however, no empirical or theoretical basis for this restriction, and instead hypothesize that plant roots of any kind are incapable of penetrating the dense clays used to seal landfills. As a test, we excavated 30 trees and shrubs, of 12 species, growing over a clay-lined municipal sanitary landfill on Staten Island, New York. The landfill had been closed for seven years, and featured a very shallow (10 to 30-cm) soil layer over a 45-cm layer of compacted grey marl (Woodbury series) clay. The test plants had invaded naturally from nearby forests. All plants examined—including trees as tall as 6 m—had extremely shallow root plates, with deformed tap roots that grew entirely above and parallel to the clay layer. Only occasional stubby feeder roots were found in the top 1 cm of clay, and in clay cracks at depths to 6 cm, indicating that the primary impediment to root growth was physical, although both clay and the overlying soil were highly acidic. These results, if confirmed by experimental research should lead to increased options for the end use of many closed sanitary landfills.  相似文献   

20.
Parathion is an insecticide of a group of highly toxic organophosphorus compounds. To investigate the dissipation and toxicological impact of parathion [O,O-diethyl O-(4-nitrophenyl) phosphorothioate] and its highly toxic metabolite, paraoxon, soil laboratory experiments were conducted in columns during a 19-d experiment under variably saturated conditions. Water and pesticide transport, sorption, and biodegradation of parathion were measured in three soil pools (soluble phase, weakly and strongly sorbed phases) using C-labeled pesticide. The effects of parathion and its metabolite on the mobility of soil nematodes were observed and then modeled with an effective variable, which combined pesticide concentration and time of application. Results showed that parathion was highly sorbed and slowly degraded to a mixture of metabolites. The parent compound and its metabolites remained located in the top 0.06-m soil layer. A kinetic model describing the sorption, biodegradation, and allocation into different soil pools of parathion and its metabolites was coupled with heat and water transport equations to predict the fate of parathion in soil. Simulated results were in agreement with experimental data, showing that the products remained in the upper soil layers even in the case of long-term (11-mo) simulation. The strongly sorbed fraction may be regarded as a pesticide reservoir that regularly provides pesticide to the weakly sorbed phase, and then, liquid phase, respectively. From both modeling and observations, no major toxicological damage of parathion and paraoxon to soil nematodes was found, although some effects on nematodes were possible, but at the soil surface only (0.01- and 0.02-m depth).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号