首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wang D  Xu X  Zheng M  Chiu CH 《Chemosphere》2002,48(8):857-863
The influences of temperature, air flow and the amount of copper chloride upon the types and amount of the toxic emissions such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs) during combustion of polyvinyl chloride (PVC) were investigated. The mechanism concerning the effect of temperature and copper chloride on the PCDD/Fs and PAHs formation was discussed. The results shown that without copper chloride, trace amounts of PCDD/Fs and large amounts of PAHs were found in the emissions from the pure PVC combustion under various combustion conditions. The addition of copper chloride enhanced PCDD/Fs formation, but it seems that the formation of PAHs decreased with increasing amount of copper chloride, and greater total amount of PAHs were produced at the higher temperature under our experimental conditions.  相似文献   

2.
Jin GZ  Lee SJ  Kang JH  Chang YS  Chang YY 《Chemosphere》2008,70(9):1568-1576
Polyethylene (PE) and polyvinyl chloride (PVC) are the leading plastics in total production in the world. The incineration of plastic-based materials forms many chlorinated compounds, such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). In this study the addition of goethite (alpha-FeOOH) was investigated to determine its suppressing effect on the emission of PCDD/Fs and hexachlorobenzene (HCB) during the combustion of wastes containing PE and PVC. Goethite was being considered since it acts as a dioxin-suppressing catalyst during incineration. Results showed that incorporation of goethite greatly reduced the generation of PCDD/Fs and HCB in the exhaust gas and fly ash. The concentration of PCDD/Fs in flue gas decreased by 45% for lab-scale and 52% for small incinerator combustion experiments, where the goethite ratios in feed samples were 0.54% and 0.34%, respectively. Under the same conditions, the concentration of HCB in flue gas decreased by 88% and 62%, respectively. The present study showed a possible mechanism of the suppressing effect of the goethite for PCDD/F formation. It is likely that iron chlorides react with particulate carbon to form organo-chlorine compounds and promote PCDD/F formation in the gas phase. XRD analysis of combustion ash revealed that the goethite was partially dehydrated and converted to alpha-Fe(2)O(3) and Fe(3)O(4) but no iron chlorides formation. Therefore the goethite impregnated plastics can contribute the reduction of PCDD/Fs and HCB in the exhaust gas during incineration of MSW.  相似文献   

3.
The authors previously proposed the concept of a new thermal remediation process for particulate/powder materials contaminated by polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and experimentally verified its validity on the basis of process efficiency. However, contaminees such as soils and fly ashes from waste incinerators often contain a considerable amount of other chlorides, which may act as a main source of chlorine in the formation of PCDD/Fs via thermal processes. The present study aims to examine the formation and transport of PCDD/Fs in the packed bed of soil containing a chloride during the process. Polyvinyl chloride (PVC) polymer was mixed with soil sample as an organic chloride model. A laboratory-scale apparatus was employed as a process simulator. Further, a technique to quench the process was applied to observe the concentration distribution of PCDD/Fs in the solid bed in the vertical direction. The result shows that the PCDFs tend to form dominantly in the high temperature (calcination and/or combustion) zone and are successively trapped in the low temperature (wet) zone. Especially, TeCDF is the most dominant homologue contained in the wet zone and outlet gas. Although PCDD/Fs are once trapped at the wet zone, the concentration of the remediated materials gives fairly low value (1.9 pg/g-dry, 0.04 pg-TEQ/g-dry). It signifies that organic chlorides mingled in the solid contaminee not affect the removal efficiency of PCDD/Fs in the process. Nevertheless, attention should be paid to the potential emission of PCDD/Fs in the outlet gas due to the presence of organic chloride in the soil.  相似文献   

4.
Qian Y  Zheng M  Liu W  Ma X  Zhang B 《Chemosphere》2005,60(7):951-958
Chlorophenols (ClPhs) are considered as important precursors for PCDD/Fs formation. The influences of series of metal oxides including MgO, Al2O3, CaO, BaO, TiO2, V2O5, MnO2, Fe2O3, Co3O4, CuO, Ag2O, ZnO, HgO, SnO, PbO, La2O3, CeO2, and Eu2O3 on PCDD/Fs formation from pentachlorophenol (PCP) were investigated in a laboratory-scale reactor. The results indicated that most of the above metal oxides have obvious suppressing effects on the total amount of PCDD/Fs formation from precursor PCP except for CuO, ZnO, MnO2, TiO2 and Co3O4 with promotion effects at 280 degrees C for 2 h. Although MgO, Al2O3, Fe2O3, PbO, La2O3 and Eu2O3 could reduce the amount of octachlorinated dibenzo-p-dioxin (OCDD), they promote the formation of more toxic 1,2,3,4,6,7,8-HpCDD at the same time. The total suppressing efficiencies of several metal oxides including CaO, BaO, PbO, Ag2O, HgO and SnO which have lower Z/r (charge to radius ratio) <2 are all over 90%. The theories of generalized acid-base and atomic parameter (Z/r) were used to speculate the effecting mechanisms. The factors including time and temperature on suppressing efficiencies of CaO, BaO and PbO have also been studied in the present paper. The results showed that the total suppressing efficiencies of CaO, BaO and PbO increase with the increase of heated time and temperature.  相似文献   

5.
Catalytic oxidation of gaseous PCDD/Fs with ozone over iron oxide catalysts   总被引:2,自引:0,他引:2  
Wang HC  Chang SH  Hung PC  Hwang JF  Chang MB 《Chemosphere》2008,71(2):388-397
Catalytic oxidation of PCDD/Fs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans) with ozone (catalytic ozonation) over nano-sized iron oxides (denoted as FexOy) was carried out at temperature of 120-180 degrees C. The effects of operating temperature, ozone concentration, space velocity (SV) and water vapor contents on PCDD/F removal and destruction efficiencies via catalytic ozonation were investigated. High activity of the iron oxide catalyst towards PCDD/F decomposition was observed even at low temperatures with the aid of ozone. The PCDD/F removal and destruction efficiencies achieved with FexOy/O3 at 180 degrees C reach 94% and 91%, respectively. In the absence of ozone, the destruction efficiencies of all PCDD/F congeners are below 20% and decrease with increasing chlorination level of PCDD/F congener at lower temperature (120 degrees C). However, in the presence of ozone, the destruction efficiencies of all PCDD/F congeners are over 80% on FexOy/O3 at 180 degrees C. Higher temperature and ozone addition increase the activity of iron oxide for the decomposition of PCDD/Fs. Additionally, in the presence of 5% water vapor, the destruction efficiency of the PCDD/Fs is above 90% even at lower operating temperature (150 degrees C). It indicates that the presence of appropriate amount of water vapor enhances the catalytic activity for the decomposition of gas-phase PCDD/Fs.  相似文献   

6.
Duo W  Leclerc D 《Chemosphere》2007,67(9):S164-S176
Both organic chlorine (e.g. PVC) and inorganic chlorides (e.g. NaCl) can be significant chlorine sources for dioxin and furan (PCDD/F) formation in combustion processes. This paper presents a thermodynamic analysis of high temperature salt chemistry. Its influence on PCDD/F formation in power boilers burning salt-laden wood waste is examined through the relationships between Cl2, HCl, NaCl(g) and NaCl(c). These analyses show that while HCl is a product of combustion of PVC-laden municipal solid waste, NaCl can be converted to HCl in hog fuel boilers by reactions with SO2 or alumino-silicate materials. Cl2 is a strong chlorinating agent for PCDD/F formation. HCl can be oxidized to Cl2 by O2, and Cl2 can be reduced back to HCl by SO2. The presence of sulphur at low concentrations thus enhances PCDD/F formation by increasing HCl concentrations. At high concentrations, sulphur inhibits de novo formation of PCDD/Fs through Cl2 reduction by excess SO2. The effect of NH3, CO and NOx on PCDD/F formation is also discussed. A semi-empirical kinetic model is proposed. This model considers both precursor and de novo formation mechanisms. A simplified version is used as a stack emission model. The kinetic model indicates that stack dioxin emissions will increase linearly with decreasing electrostatic precipitator (ESP) efficiency and exponentially with increasing ESP temperature.  相似文献   

7.
The effect of temperature on polyvinylchloride (PVC) combustion using a downstream tubular furnace was investigated for the formation of polycylcic aromatic hydrocarbons (PAHs) and chlorinated compounds. As the temperature increased, higher levels of PAHs were generated. Chlorinated compounds reached a peak at 600 degrees C, with low emissions recorded at 300 and 900 degrees C. There was a close correlation (R2 = 0.97) among polychlorinated biphenyls (PCBs), hexachlorobenzene, pentachlorobenzene, and polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). PAHs at all temperatures were analyzed in the gas phase. PCDD/Fs and PCBs were emitted as a solid phase at 300 and 600 degrees C and as a gas phase at 900 degrees C. For some PAHs, chlorobenzenes, and PCDD/Fs, a mathematical equation between the gas and solid phase and the reciprocal temperature in semilog proportion was derived. The proposed equation, which is log (amount in gas phase/amount in solid phase) = -A/T + B, where T is the temperature of the furnace and A and B are constants, for these species relating their gas/solid distributions showed a good relationship.  相似文献   

8.
Urea as a PCDD/F inhibitor in municipal waste incineration   总被引:2,自引:0,他引:2  
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at approximately 730 degrees C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

9.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at ~730 °C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

10.
Thermal remediation of PCDD/Fs contaminated soil by zone combustion process   总被引:1,自引:0,他引:1  
A new thermal process has been proposed for remediating soils contaminated by chlorinated organic compounds, e.g., PCDD/Fs and PCBs. This is to apply the "zone combustion process" which utilizes stable combustion of coke particles in the packed bed to soils with air flow across the bed. The usefulness and validity were obtained the results showing that more than 98.9% of PCDD/Fs in the soil was successfully removed in a laboratory-scale experiment. Some pretreatment of the soil sample, such as drying, pre-granulation and addition of limestone was found to make the removal efficiency better. Although, some fundamentals on the behavior of PCDD/Fs, e.g., decomposition/vaporization ratios and formation of other compounds cannot be certainly identified yet, the present results clearly show a way to remediate the contaminated soils and solid wastes.  相似文献   

11.
Abstract

The effect of temperature on polyvinylchloride (PVC) combustion using a downstream tubular furnace was investigated for the formation of polycylcic aromatic hydrocarbons (PAHs) and chlorinated compounds. As the temperature increased, higher levels of PAHs were generated. Chlorinated compounds reached a peak at 600°C, with low emissions recorded at 300 and 900°C. There was a close correlation (R2 = 0.97) among polychlorinated bi-phenyls (PCBs), hexachlorobenzene, pentachloroben-zene, and polychlorinated dibenzo-p-dioxins and poly-chlorinated dibenzofurans (PCDD/Fs). PAHs at all temperatures were analyzed in the gas phase. PCDD/Fs and PCBs were emitted as a solid phase at 300 and 600°C and as a gas phase at 900°C. For some PAHs, chloroben-zenes, and PCDD/Fs, a mathematical equation between the gas and solid phase and the reciprocal temperature in semilog proportion was derived. The proposed equation, which is log (amount in gas phase/amount in solid phase) = ?A/T + B, where T is the temperature of the furnace and A and B are constants, for these species relating their gas/solid distributions showed a good relationship.  相似文献   

12.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

13.
Xhrouet C  De Pauw E 《Chemosphere》2005,59(10):1399-1406
The sintering process is among the major sources of the very toxic polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in the environment. At the industrial scale, it has been shown that dust collected on the grid, which supports the feed, contains PCDD/Fs amounts between the values found in the bottom of the cake and the values found on dust collected during gas sampling in the wind boxes. This fact suggests that the grid, containing 25wt.% of chromium, could have a catalytic activity in PCDD/Fs formation during the sintering process. This research tries to study this potential role. The de novo synthesis of PCDD/Fs is simulated at laboratory scale by thermal treatments of samples mixed with grid filings or Cr2O3. The thermal experiments performed with E.S.P. dust (dust collected in the electrostatic precipitator of a sintering plant) or graphite mixed with grid filings do not allow to confirm a role of the grid in PCDD/Fs formation during the industrial process. On the other hand, it has been shown that Cr2O3 can be considered as a catalyst in the de novo synthesis of PCDD/Fs. This compound takes place in the two steps of the de novo synthesis: the degradation of the carbon matrix as well as the chlorination reactions.  相似文献   

14.
Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers' findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/ Fs, also needs to be carefully reconsidered.  相似文献   

15.
Abstract

Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers’ findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/Fs, also needs to be carefully reconsidered.  相似文献   

16.
Ohta M  Oshima S  Osawa N  Iwasa T  Nakamura T 《Chemosphere》2004,54(10):1521-1531
PVDC and three non-chlorinated polymers (PP, PET, and PA) were incinerated at 700-850 degrees C in a laboratory-scale quartz tubular furnace in the presence of HCl (ca. 500 ppm congruent with 0.8 mg/l), and the gas-phase formation of PCDD/Fs, their putative precursors and their homologue profiles were investigated. The addition of HCl had little or no apparent effect on the level of PCDD/Fs formation during PVDC combustion, and their homologue profiles were quite different from those of the three non-chlorinated polymers. With PVDC, O8CDD and particularly O8CDF were by far most prevalent, apparently as a result of the selective formation of the precursors. With each of the three non-chlorinated polymers, combustion at 800 degrees C or higher in the presence of HCl resulted in PCDD/Fs formation at levels equaling or exceeding those observed with PVDC. In trials made with one of them (PP) under the same conditions but using a large polymer sample (100 mg vs 20 mg in all other trials), the level of PCDD/Fs formation was far higher than with the smaller polymer samples, and thus demonstrated the importance of appropriate combustion conditions for polymer incineration.  相似文献   

17.
Chi KH  Chang SH  Huang CH  Huang HC  Chang MB 《Chemosphere》2006,64(9):1489-1498
Activated carbon adsorption is commonly used to control dioxin-like congener (PCDD/Fs and PCBs) emissions. Partitioning of PCDD/Fs and PCBs between vapor and solid phases and their removal efficiencies achieved with existing air pollution control devices (APCDs) at a large-scale municipal waste incinerator (MWI) and an industrial waste incinerator (IWI) are evaluated via intensive stack sampling and analysis. Those two facilities investigated are equipped with activated carbon injection (ACI) with bag filter (BF) and fixed activated carbon bed (FACB) as major PCDD/F control devices, respectively. Average PCDD/F and PCB concentrations of stack gas with ACI+BF as APCDs are 0.031 and 0.006ng-TEQ/Nm(3), and that achieved with FACB are 1.74 and 0.19ng-TEQ/Nm(3) in MWI and IWI, respectively. The results show that FACB could reduce vapor-phase PCDD/Fs and PCBs concentrations in flue gas, while the ACI+BF can effectively adsorb the vapor-phase dioxin-like congener and collect the solid-phase PCDD/Fs and PCBs in the meantime. Additionally, the results of the pilot-scale adsorption system (PAS) experimentation indicate that each gram activated carbon adsorbs 105-115ng-PCDD/Fs and each surface area (m(2)) of activated carbon adsorbs 10-25ng-PCDD/Fs. Based on the results of PAS experimentation, this study confirms that the surface area of mesopore+macropore (20-200A) of the activated carbon is a critical factor affecting PCDD/F adsorption capacity.  相似文献   

18.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

19.
Yang CC  Chang SH  Hong BZ  Chi KH  Chang MB 《Chemosphere》2008,73(6):890-895
Development of effective PCDD/F (polychlorinated dibenzo-p-dioxin and dibenzofuran) control technologies is essential for environmental engineers and researchers. In this study, a PCDD/F-containing gas stream generating system was developed to investigate the efficiency and effectiveness of innovative PCDD/F control technologies. The system designed and constructed can stably generate the gas stream with the PCDD/F concentration ranging from 1.0 to 100ng TEQ Nm(-3) while reproducibility test indicates that the PCDD/F recovery efficiencies are between 93% and 112%. This new PCDD/F-containing gas stream generating device is first applied in the investigation of the catalytic PCDD/F control technology. The catalytic decomposition of PCDD/Fs was evaluated with two types of commercial V(2)O(5)-WO(3)/TiO(2)-based catalysts (catalyst A and catalyst B) at controlled temperature, water vapor content, and space velocity. 84% and 91% PCDD/F destruction efficiencies are achieved with catalysts A and B, respectively, at 280 degrees C with the space velocity of 5000h(-1). The results also indicate that the presence of water vapor inhibits PCDD/F decomposition due to its competition with PCDD/F molecules for adsorption on the active vanadia sites for both catalysts. In addition, this study combined integral reaction and Mars-Van Krevelen model to calculate the activation energies of OCDD and OCDF decomposition. The activation energies of OCDD and OCDF decomposition via catalysis are calculated as 24.8kJmol(-1) and 25.2kJmol(-1), respectively.  相似文献   

20.
Liu H  Zhang Q  Wang Y  Cai Z  Jiang G 《Chemosphere》2007,68(9):1772-1778
The pollution status of polychlorinated dibenzo-p-dioxins, dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) in the sediments of Haihe River, which is the most polluted among the seven largest basins in China, Dagu Drainage River flowing through a chemical industry zone, and two other rivers flowing into Bohai Sea in Tianjin City, China were investigated. The concentrations of PCDD/Fs and PCBs in the sediments from the mainstream of Haihe River were 1.3-26pgI-TEQg(-1) dry weight (dw) and 0.07-0.54pgTEQg(-1)dw, respectively. Heavy PCDD/Fs and PCBs pollution, with 1264pgI-TEQg(-1)dw and 21pgTEQg(-1)dw, was found in sediment from Dagu Drainage River. The congener profiles of PCDD/Fs indicated that the principal contamination source was the production of pentachlorophenol (PCP) or PCP-Na in this area. The correlation between PCDD/Fs or PCBs and total organic matter (TOM) showed that PCDD/Fs or PCBs were independent on TOM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏