首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 759 毫秒
1.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   

2.
In order to investigate snowpack sensitivity to temperature increases and end‐member atmospheric moisture conditions, we applied a well‐constrained energy‐ and mass‐balance snow model across the full elevation range of seasonal snowpack using forcing data from recent wet and dry years. Humidity scenarios examined were constant relative humidity (high) and constant vapor pressure between storms (low). With minimum calibration, model results captured the observed magnitude and timing of snowmelt. April 1 snow water equivalent (SWE) losses of 38%, 73%, and 90% with temperature increases of 2, 4, and 6°C in a dry year centered on areas of greatest SWE accumulation. Each 2°C increment of warming also resulted in seasonal snowline moving upslope by 300 m. The zone of maximum melt was compressed upward 100–500 m with 6°C warming, with the range reflecting differences in basin hypsometry. Melt contribution by elevations below 2,000 m disappeared with 4°C warming. The constant‐relative‐humidity scenario resulted in 0–100 mm less snowpack in late spring vs. the constant‐vapor‐pressure scenario in a wet year, a difference driven by increased thermal radiation (+1.2 W/m2) and turbulent energy fluxes (+1.2 W/m2) to the snowpack for the constant‐relative‐humidity case. Loss of snowpack storage and potential increases in forest evapotranspiration due to warming will result in a substantial shift in forest water balance and present major challenges to land management in this mountainous region.  相似文献   

3.
利用车载环境空气质量监测系统对长沙市城区典型交通路口的近地面空气质量进行了实时监测。结果表明,在监测时段(14∶00~20∶00)内,该监测点环境空气中PM10的小时质量浓度范围在0.097~0.222mg/m3之间,平均值0.163mg/m3;PM2.5的小时质量浓度范围在0.050~0.158mg/m3之间,平均值0.103mg/m3。PM2.5/PM10比值在48.1%~76.6%之间,平均值62.4%。PM10与PM2.5质量浓度在星期一相对较低,星期二有所升高,星期三至周末总体上保持基本稳定。在监测时段PM10与PM2.5小时质量浓度呈现先降后升的变化规律,即14∶00~15∶00,PM10与PM2.5质量浓度相对较高,16∶00左右降至最低,从17∶00开始逐渐升高,20∶00达到峰值。PM10和PM2.5的质量浓度变化与车流量和车速密切相关,温度、相对湿度和风速等气象因素对PM10和PM2.5质量浓度的变化影响也较显著。  相似文献   

4.
Commercially available adsorption cooling systems use water/silica gel, water/zeolite and ammonia/ chloride salts working pairs. The water-based pairs are limited to work above 0°C due to the water high freezing temperature, while ammonia has the disadvantage of being toxic. Ethanol is a promising refrigerant due to its low freezing point (161 K), nontoxicity, zero ozone depletion, and low global warming potential. Activated carbon (AC) is a porous material with high degree of porosity (500–3000 m2/g) that has been used in wide range of applications. Using Dynamic Vapour Sorption (DVS) test facility, this work characterizes the ethanol adsorption of eleven commercially available activated carbon materials for cooling at low temperature of ?15°C. DVS adsorption results show that Maxsorb has the best performance in terms of ethanol uptake and adsorption kinetics compared to the other tested materials. The Maxsorb/ethanol adsorption process has been numerically modeled using computational fluid dynamics (CFD) and simulation results are validated using the DVS experimental measurements. The validated CFD simulation of the adsorption process is used to predict the effects of adsorbent layer thickness and packing density on cycle uptake for evaporating temperature of ?15°C. Simulation results show that as the thickness of the Maxsorb adsorbent layer increases, its uptake decreases. As for the packing density, the amount of ethanol adsorbed per plate increases with the packing density reaching maximum at 750 kg/m3. This work shows the potential of using Maxsorb/ethanol in producing low temperature cooling down to ?15°C with specific cooling energy reaching 400 kJ/kg.  相似文献   

5.
This study focused on greening designs for building openings. Field experimentation was conducted and Computational Fluid Dynamics (CFD) software was used for simulation in order to analyze the influence of different greening design modes on indoor temperature. A greening design mode suitable for the opening of houses in Kaohsiung was proposed. This study took an architectural space with a pitched roof as the experimental site, where the main variable was the location of the plant facade outside the opening, and the distance between the plant and wall surface, as well as the number of plant layers, was the control variable. A plant (Rose of China) was selected for experimentation, and the indoor temperature distributions under various research module settings were discussed by numerical simulation. The conclusions are described, as follows: (1) The air temperature would be affected by the plants, and the indoor air temperature is reduced (over 0.5°C without direct sunshine in this study). (The difference between the indoor cooling effects with and without plants was 0.89~1.11°C. (2) While the cooling effect of the double-layer plant on indoor air temperature was better than a single-layer plant, the difference was limited and not proportional. (3) The plants should be located as close to the opening as possible, and be arranged partially sparse and partially dense. (4) When the outside wind speed is low, plant greening is highly recommended for cooling.  相似文献   

6.
In this study, an innovative heat and mass transfer core is proposed to provide thermal comfort and humidity control using a hollow fiber contactor with multiple bundles of micro-porous hollow fibers. The hollow fiber-based core utilizes 12 bundles aligned vertically, each with 1,000 packed polypropylene hollow fibers. The proposed core was developed and tested under various operating and ambient conditions as a cooling core for a compact evaporative cooling unit and a dehumidification core for a liquid desiccant dehumidification unit. As a cooling core, the fiber-based evaporative cooler provides a maximum cooling capacity of 502 W with a wet bulb effectiveness of 85%. As a dehumidification core and employing potassium formate as a liquid desiccant, the dehumidifier is capable of reducing the air relative humidity by 17% with an overall dehumidification capacity of 733 W and humidity effectiveness of 47%. Being cheap and simple to design with their attractive heat and mass transfer characteristics and the corresponding large surface area-to-volume ratio, hollow fiber membrane contactors provide a promising alternative for cooling and dehumidification applications.  相似文献   

7.
In this study, we demonstrate a physically based semi-Lagrangian water temperature model known as the River Basin Model (RBM) coupled with the Variable Infiltration Capacity (VIC) hydrological model and Weather Research & Forecasting Model in the Mississippi River Basin (MRB). The results of this coupling compare favorably with observed water temperature data available from six river gages located in the MRB. Further sensitivity analysis indicates that the mean water temperatures may increase by 1.3, 1.5, and 1.8°C in northern, central, and southern MRB zones under a hypothetical uniform air temperature increase of 3.0°C. If air temperatures increase uniformly by 6.0°C in this scenario, then water temperatures are projected to increase by 3.3, 3.5, and 4.0°C. Lastly, downscaled air temperatures from a global climate model are used to drive the coupled VIC and RBM model from 2020 to 2099. Average stream temperatures from 2020 to 2099 increase by 1.0 to 8.0°C above 1950 to 2010 average water temperatures, with non-uniform increases along the river. In some portions of the MRB, stream temperatures could increase above survival thresholds for several native fish species, which are critical components of the stream ecosystem. In addition, increased water temperatures interact with nutrient loadings from sources throughout the MRB, which is expected to exacerbate harmful algal blooms and dead zones in the Gulf of Mexico.  相似文献   

8.
A hybrid cooling system consisting of both a dry section and wet section is proposed in this paper as a means to conserving energy and water by combining the benefits of both dry and wet cooling modes. A new thermodynamic coupling characteristics computing model was established to identify the best combination of dry and wet cooling subsystems in the hybrid tower throughout year-round operation based on its air thermodynamic state under the “no plume” principle. A hybrid cooling tower in Inner Mongolia, China, consisting of an elliptical tube heat exchanger with rectangular fins and counter-flow wet packing, was designed as an example under the no plume principle. The minimum number of heat exchanger units in service and the corresponding thermodynamic operating parameters were obtained under a year-round operation. The tower exhibited notable advantages in regards to water conservation compared to the traditional evaporative cooling tower at an estimated yearly savings of 3.74 × 107 kg water.  相似文献   

9.
ABSTRACT: Air temperatures are sometimes used as easy substitutes for stream temperatures. To examine the errors associated with this substitution, linear relationships between 39 Minnesota stream water temperature records and associated air temperature records were analyzed. From the lumped data set (38,082 daily data pairs), equations were derived for daily, weekly, monthly, and annual mean temperatures. Standard deviations between all measured and predicted water temperatures were 3.5°C (daily), 2.6°C (weekly), 1.9°C (monthly), and 1.3°C (annual). Separate analyses for each stream gaging station gave substantially lower standard deviations. Weather monitoring stations were, on average, 37.5 km from the stream. The measured water temperatures follow the annual air temperature cycle closely. No time lags were taken into account, and periods of ice cover were excluded from the analysis. If atmospheric CO2 doubles in the future, air temperatures in Minnesota are projected (CCC GCM) to rise by 4.3°C in the warm season (April-October). This would translate into an average 4.1°C stream temperature rise, provided that stream shading would remain unaltered.  相似文献   

10.
Simulations of stream temperatures showed a wide range of future thermal regimes under a warming climate — from 2.9°C warmer to 7.6°C cooler than current conditions — depending primarily on shade from riparian vegetation. We used the stream temperature model, Heat Source, to analyze a 37‐km study segment of the upper Middle Fork John Day River, located in northeast Oregon, USA. We developed alternative future scenarios based on downscaled projections from climate change models and the composition and structure of native riparian forests. We examined 36 scenarios combining future changes in air temperature (ΔTair = 0°C, +2°C, and +4°C), stream discharge (ΔQ = ?30%, 0%, and +30%), and riparian vegetation (post‐wildfire with 7% shade, current vegetation with 19% shade, a young‐open forest with 34% shade, and a mature riparian forest with 79% effective shade). Shade from riparian vegetation had the largest influence on stream temperatures, changing the seven‐day average daily maximum temperature (7DADM) from +1°C to ?7°C. In comparison, the 7DADM increased by 1.4°C with a 4°C increase in air temperature and by 0.7°C with a 30% change in discharge. Many streams throughout the interior western United States have been altered in ways that have substantially reduced shade. The effect of restoring shade could result in future stream temperatures that are colder than today, even under a warmer climate with substantially lower late‐summer streamflow.  相似文献   

11.
ABSTRACT: Bacterial populations in a fast flowing stream receiving chemical wastes and in a slower flowing pond receiving a thermal addition 3–5°C above ambient temperature were compared with populations in a nonpolluted converging stream and an adjacent unheated pond. Parameters measured were total aerobic heterotrophic bacteria, bacterial diversity, percent chromagens of the total bacterial populations, and water temperature. Analyses of monthly samples plated on dilute Standard Plate Count Agar indicated that chemical additives to the waste stream significantly decreased the percent of chromagenic bacteria, and that thermal stress significantly altered total counts and bacterial diversity in the flowing pond. The effects of potential pollutants on these aquatic systems were assessed and are discussed on the basis of results obtained over a 16-month period.  相似文献   

12.
ABSTRACT: Discrete cold water patches within the surface waters of summer warm streams afford potential thermal refuge for cold water fishes during periods of heat stress. This analysis focused on reach scale heterogeneity in water temperatures as influenced by local influx of cooler subsurface waters. Using field thermal probes and recording thermistors, we identified and characterized cold water patches (at least 3°C colder than ambient streamflow temperatures) potentially serving as thermal refugia for cold water fishes. Among 37 study sites within alluvial valleys of the Grande Ronde basin in northeastern Oregon, we identified cold water patches associated with side channels, alcoves, lateral seeps, and floodplain spring brooks. These types differed with regard to within floodplain position, area, spatial thermal range, substrate, and availability of cover for fish. Experimental shading cooled daily maximum temperatures of surface waters within cold water patches 2 to 4°C, indicating a strong influence of riparian vegetation on the expression of cold water patch thermal characteristics. Strong vertical temperature gradients associated with heating of surface layers of cold water patches exposed to solar radiation, superimposed upon vertical gradients in dissolved oxygen, can partially restrict suitable refuge volumes for stream salmonids within cold water patches.  相似文献   

13.
王茹静 《四川环境》2014,(1):119-123
大多数内陆核电厂将采用大型自然通风冷却塔作为其二次循环冷却方式,本文基于美国核管会推荐的SACTI程序,给出了该模型的基本原理和框架结构,并以江西彭泽核电厂为例,采用该程序预测分析了该核电厂大型自然通风冷却塔所造成的雾羽和太阳辐射损失的影响。并进一步研究了不同环境风速、相对湿度条件下对冷却塔造成的太阳辐射损失的影响。SACTI模型可以根据厂址逐时气象观测数据,较好地计算可见雾羽的长度、抬升高度和太阳辐射损失,其结果可以作为冷却塔环境影响评价的依据。  相似文献   

14.
ABSTRACT: In a study to measure the efficacy of chioramines at inactivating Giardia cysts, the ability of cysts to excyst was measured after exposure to different concentrations of chloramines, for different times, and at different temperatures and pH. The chloramines were generated by mixing ammonium sulfate and sodium hypochlorate in water to approximate a 7:1 chlorine:ammonia ratio by weight. Times of 40, 80, 180, and 270 minutes; temperatures of 3, 10, and 18°C; target chioramine concentrations of 0.4, 1.4, 2.0, and 2.6 mg/L; and pH of 7.0 and 8.5 were the actual values tested. The combinations of these variables that were able to inactivate >99.8 percent of the cysts were a minimum chloramine concentration of 2.26 mg/L applied for 270 minutes at a water temperature of 10°C; and at 18°C, averaged minimum chloramine concentrations of 2.14 and 1.55 mg/L applied for 180 and 270 minutes, respectively. The minimum CT values corresponding to these combinations capable of >99.8 percent cyst inactivation, are 610 at 10°C and 385 at 18°C. Temperature was noted to exert a major effect on the ability of chloramines to inactivate cysts. Modifications of the methods used to generate chloramines may have an effect on the capacity of this disinfectant to inactivate cysts.  相似文献   

15.
Emitted thermal infrared radiation (TIR, λ= 8 to 14 μm) can be used to measure surface water temperatures (top approximately 100 μm). This study evaluates the accuracy of stream (50 to 500 m wide) and lake (300 to 5,000 m wide) radiant temperatures (15 to 22°C) derived from airborne (MASTER, 5 to 15 m) and satellite (ASTER 90 m, Landsat ETM+ 60 m) TIR images. Applied atmospheric compensations changed water temperatures by ?0.2 to +2.0°C. Atmospheric compensation depended primarily on atmospheric water vapor and temperature, sensor viewing geometry, and water temperature. Agreement between multiple TIR bands (MASTER ‐ 10 bands, ASTER ‐ 5 bands) provided an independent check on recovered temperatures. Compensations improved agreement between image and in situ surface temperatures (from 2.0 to 1.1°C average deviation); however, compensations did not improve agreement between river image temperatures and loggers installed at the stream bed (from 0.6 to 1.6°C average deviation). Analysis of field temperatures suggests that vertical thermal stratification may have caused a systematic difference between instream gage temperatures and corrected image temperatures. As a result, agreement between image temperatures and instream temperatures did not imply that accurate TIR temperatures were recovered. Based on these analyses, practical accuracies for corrected TIR lake and stream surface temperatures are around 1°C.  相似文献   

16.
Although moisture has a decisive role in the permanence of cellulose and unprinted paper, its role in ink release from the surface of printed recovered papers remains unclear. This work aimed to determine whether various relative humidity levels in the artificial aging test affect ink release from the surface of the paper and its fibers when pulping cold-set offset printed newspapers in alkaline pulping conditions. The results showed that relative humidity variations from 30% to 70% negligibly affected ink release at 60 °C. However, compared with these lower humidity levels, exposure to 90% relative humidity for at least 25 h resulted in a higher ink content bound to fibers, a greater formation of visible dirt specks after pulping and a smaller formation of microscopic ink particles. In practical applications, the accurate estimation of climate effects during the storage and the transportation of recycled papers requires that humidity conditions are taken into account while performing artificial aging tests with paper products.  相似文献   

17.
ABSTRACT: One of the biggest challenges in managing cold water streams in the Midwest is understanding how stream temperature is controlled by the complex interactions among meteorologic processes, channel geometry, and ground water inflow. Inflow of cold ground water, shade provided by riparian vegetation, and channel width are the most important factors controlling summer stream temperatures. A simple screening model was used to quantitatively evaluate the importance of these factors and guide management decisions. The model uses an analytical solution to the heat transport equation to predict steady‐state temperature throughout a stream reach. The model matches field data from four streams in southwestern Wisconsin quite well (typically within 1°C) and helps explain the observed warming and cooling trends along each stream reach. The distribution of ground water inflow throughout a stream reach has an important influence on stream temperature, and springs are especially effective at providing thermal refuge for fish. Although simple, this model provides insight into the importance of ground water and the impact different management strategies, such as planting trees to increase shade, may have on summer stream temperature.  相似文献   

18.
An experimental study has been carried out to analyze the effect of inclined ribs used as roughness element on heat transfer along its friction characteristics. The roughness parameters include relative roughness pitch (P/e) ranges from 4–16, relative roughness height (e/Dh) ranges from 0.021–0.043 and angle of attack (α) ranges from 30° to 75°. The Reynolds number (Re) lies in the range of 4500–28000. The heat transfer and friction factor data obtained from the experiment and it is compared with the data obtained from smooth duct under the same conditions. Considerable augmentation was observed in heat transfer and friction over the smooth duct. Correlation was also developed for Nusselt number (Nu) and friction factor (f) as a function of roughness and flow parameter.  相似文献   

19.
Abstract: The summertime heating of runoff in urban areas is recognized as a common and consistent urban climatological phenomenon. In this study, a simple thermal urban runoff model (TURM) is presented for the net energy flux at the impervious surfaces of urban areas to account for the heat transferred to runoff. The first step in developing TURM consists of calculating the various factors that control how urban impervious areas absorb heat and transfer it to moving water on the surface. The runoff temperature is determined based on the interactions of the physical characteristics of the impervious areas, the weather, and the heat transfer between the moving film of runoff and the impervious surface common in urban areas. Key surface and weather factors that affect runoff temperature predictions are type of impervious surface, air temperature, humidity, solar radiation before and during rain, rainfall intensity, and rainfall temperature. Runoff from pervious areas is considered separately and estimated using the Green‐Ampt Mein‐Larson rainfall excess method. Pervious runoff temperature is estimated as the rainfall temperature. Field measurements indicate that wet bulb temperature can be used as a surrogate for rainfall temperature and that runoff temperatures from sod average just 2°C higher than rainfall temperatures. Differences between measured and predicted impervious runoff temperature average approximately 2°C, indicating that TURM is a useful tool for determining runoff temperatures for typical urban areas.  相似文献   

20.
The storage of fresh agricultural products is not easy because of its high moisture. Dehydration is an efficient preservation method. The investigation of drying modeling and transfer characteristics are important for selecting operating conditions and equipment design. The drying behavior of Lactuca sativa slices, with the thickness of 2 mm, was investigated at 60.0–80.0°C and 0.60–1.04 m sec?1 velocity in a convective hot air drier. The mass transfer during the drying process was described using six thin drying models. The convective heat transfer coefficient α and mass transfer coefficient kH were finally calculated. The results showed that the drying process could be separated into three stages including accelerating rate, constant rate, and falling rate period, which was influenced by hot air temperature and velocity, and the Modi?ed Page model agreed well with the experimental data. When the operating temperature was increased from 60.0°C to 80.0°C, α was found increased from 88.07 to 107.93 W·m?2·K?1, and kH increased from 46.32 × 10–3 to 68.04 × 10–3 kg·m?2·sec?1·ΔH?1. With the increase of air velocity from 0.60 to 1.04 m·sec?1, α was increased from 78.85 to 101.35 W·m?2·K?1, and kH was enhanced from 51.78 × 10–3 to 65.85 × 10–3 kg·m?2·sec?1·ΔH?1.  相似文献   