首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
ABSTRACT

Al2O3/water nanofluid has been numerically examined for the first time with different nanoparticle shapes including, cylindrical, blade, brick, platelet and spherical, on the flat and triangular-corrugated impinging surfaces. The volume fractions of 1.0%, 2.0% and 3.0% nanoparticles have been used. The Reynolds number is between 100–500 depending on the slot diameter. The finite volume method is utilized to determine the governing equations. The study is analyzed to determine how the flow features, heat transfer features and entropy production were affected by the diversity of nanoparticle shape, nanoparticle volume fraction, and shape of impinging surface. Darcy friction factor and Nusselt number are studied in detail for different conditions. The temperature contours are presented in the case of different nanoparticle volume fractions, nanoparticle shapes and both impinging surfaces. The results of the study suggest that the nanoparticle shape of the platelet shows the highest heat transfer development due to the thinner thermal boundary layer. Heat transfer augments with increasing volume fraction of nanoparticles. In addition, the study is consistent with the results of the literature on heat transfer and flow properties.  相似文献   

2.
The performance characteristics of a solar air heater can effectively be improved by providing artificial roughness in the form of protrusions and dimples of various shapes, sizes, and orientations on the underside of heated surface. An extensive literature review on artificial roughness elements has been carried and the correlations developed for heat transfer and friction factor for roughened solar air collector have been discussed and presented in this paper. The performance parameter has also been computed and compared with various kinds and shapes of roughness geometries using correlations developed by various investigators. The optimum values of the roughness parameters obtained by several investigators have also been discussed.  相似文献   

3.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   

4.
Artificially roughened solar air heater has been topic in research for the last 30 years. Prediction of heat transfer and fluid flow processes of an artificially roughened solar air heater can be obtained by three approaches: theoretical, experimental, and computational fluid dynamics (CFD). This article provides a comprehensive review of the published literature on the investigations of artificially roughened solar air heater. In the present article, an attempt has been made to present holistic view of various roughness geometries used for creating artificial roughness in solar air heater for heat transfer enhancement. This extensive review reveals that quite a lot of work has been reported on design of artificially roughened solar air heater by experimental approach but only a few studies have been done by theoretical and CFD approaches. Finally this article presents a comparative study of thermo-hydraulic performance of 21 different types of artificial roughness geometries attached on the absorber plate of solar air heater in terms of thermo-hydraulic performance parameter. Heat transfer and friction factor correlations developed by various investigators for different types of artificially roughened solar air heaters have also been reported in this article.  相似文献   

5.
The storage of fresh agricultural products is not easy because of its high moisture. Dehydration is an efficient preservation method. The investigation of drying modeling and transfer characteristics are important for selecting operating conditions and equipment design. The drying behavior of Lactuca sativa slices, with the thickness of 2 mm, was investigated at 60.0–80.0°C and 0.60–1.04 m sec?1 velocity in a convective hot air drier. The mass transfer during the drying process was described using six thin drying models. The convective heat transfer coefficient α and mass transfer coefficient kH were finally calculated. The results showed that the drying process could be separated into three stages including accelerating rate, constant rate, and falling rate period, which was influenced by hot air temperature and velocity, and the Modi?ed Page model agreed well with the experimental data. When the operating temperature was increased from 60.0°C to 80.0°C, α was found increased from 88.07 to 107.93 W·m?2·K?1, and kH increased from 46.32 × 10–3 to 68.04 × 10–3 kg·m?2·sec?1·ΔH?1. With the increase of air velocity from 0.60 to 1.04 m·sec?1, α was increased from 78.85 to 101.35 W·m?2·K?1, and kH was enhanced from 51.78 × 10–3 to 65.85 × 10–3 kg·m?2·sec?1·ΔH?1.  相似文献   

6.
Abstract

In this article, the convective heat transfer coefficients of various agricultural products were investigated under open sun drying conditions. Data obtained from open sun drying experiments for eight agricultural products, namely, mulberry, strawberry, apple, garlic, potato, pumpkin, eggplant, and onion were used to determine values of convective heat transfer coefficient. The value of convective heat transfer coefficient was determined as 1.861 W/m2°C for mulberry, 6.691 W/m2°C for strawberry, 11.323 W/m2°C for apple, 1.136 W/m2°C for garlic, 8.224 W/m2°C for potato, 8.613 W/m2°C for pumpkin, 6.981 W/m2°C for eggplant, and 6.767 W/m2°C for onion. The experimental error in terms of percent uncertainty was also calculated.  相似文献   

7.
An experimental analysis of heat transfer efficiency in double glazing solar water heating system having full-length Horizontal wing cut twisted tapes having twist ratio 3 fitted with rod or spacer of dimensions 125 mm, 250 mm, and 500 mm as length at the trailing edges has been dealt in this work. The experimental results have been compared with a plain tube with similar operating conditions and concluded that variation in the Nusselt number, as well as friction factor, are ±12.56% and ±10.17%, respectively. The result of empirical correlation concludes that Nusselt number is maximal for horizontal wing cut twisted tapes having rod or spacer at its ends while comparing with full-length horizontal wing cut twisted tapes. The friction factor is low for full-length horizontal wing cut twisted tapes than the horizontal wing cut twisted tapes fitted with rod or spacer. The horizontal wing cut twisted tapes fitted with rod has superior performance than twist fitted with spacer.  相似文献   

8.
ABSTRACT

This paper discusses about the effect of feeder height and heat flux on the heat transfer characteristics of horizontal tube falling film evaporation in the thermal regimes. In order to investigate this, a two- dimensional CFD model was developed to perform simulation and results were compared and validated with published data available in the literature. Heat transfer co-efficients in the thermal regimes were determined from the CFD simulation and the results were recorded, analyzed and validated with the mathematical models available in the literature. The novelty of the current study is to predict the commencement of the fully developed thermal region over the tube from the simulation model under varying feeder height and heat flux. An effort was also made to measure the liquid film thickness around the tube from the CFD model in the thermal regimes. It is observed that angle of thermally developing region contracts and fully developed thermal region extends with the increase of the feeder height and heat flux. It is observed from the study that increase of heat flux by 10 kW/m2 resulted in increase of heat transfer co-efficient value by 10–12% average in thermally developing region and 12–15% average in fully developed region. Thinnest liquid film thickness observed between 85 and 127°angle. Shifting of thinnest region of liquid film upward from the mid tube with the increase of the feeder height and heat flux is noted.  相似文献   

9.
The speed and direction of air flow through complex terrain are difficult to define. Both impact sensible and latent heat flux exchanges at the surface. Evapotranspiration (ET) models such as Mapping EvapoTranspiration at high Resolution with Internalized Calibration (METRIC?) estimate ET as a residual of the surface energy process and are thus sensitive to aerodynamics, including terrain‐induced impacts on roughness governing convective heat transfer (H). There is a need to explore the sensitivities of H estimation and thereby ET estimation to wind speed and terrain roughness in mountainous areas and to determine the merit of operating complex mesoscale wind field models in conjunction with the energy balance process. A sensitivity analysis is explored in METRIC where we increased wind speed in proportion to a relative elevation parameter and we increased aerodynamic roughness to assimilate impacts of relative terrain roughness, estimated in proportion to standard deviation of elevation within a 3 km locality. These aerodynamic modifications increased convective heat transfer in complex terrain and reduced estimated ET. In other sensitivity runs, we reduced estimated wind speed on estimated leeward slopes. Estimated ET with and without these sensitivity adjustments is shown for mountainous areas of Montana and Nevada. Changes in ET ranged from little change (<5%) for lower slopes to about 30% reductions on windward slopes and 25% increases on leeward slopes for some mid to high elevations in the Montana application.  相似文献   

10.
The main object of this study was the investigation of the thermal recycling of commingled waste textile fibers, with the aim of the production of useful end products. Differential scanning calorimetry/Thermo gravimetric analysis (DSC/TGA) was applied to determine the thermal degradation characteristics of the commingled waste textile fibers and there are two peaks located at the temperature ranges of 299–360°C and 399–500°C. Commingled waste fiber was pyrolyzed in a nitrogen atmosphere in relation to three different temperatures (500, 600, and 700°C), heating rates (25 and 50°C min?1), and retention times (15 and 30 min). The effect of the experimental conditions such as pyrolysis temperature, heating rates, and retention time on the formation of char and gas--liquid products was investigated and the product yields were determined from the rate of the weight loss. The highest conversion rate 82.9 wt.% liquid--gas product and 17.1 wt.% char product was achieved at 700°C. Pyrolysis gases were taken for every 7, 15, and 25 min and were analyzed for major components such as CO, CO2, CH4, and H2 by gas chromatography. The pyrolysis char called as carbon black derived from the pyrolysis of commingled waste textile fibers was analyzed for a range of properties, including the elemental analysis, moisture content, ash content, calorific value, and trace metal analysis.  相似文献   

11.
In this article, a comparative study is presented for the transcritical cycle with expansion valve (TCEV) and transcritical cycle with vortex tube (TCVT) mainly based on the second law of thermodynamics. Natural refrigerant nitrous oxide (N2O) is used in both the cycles for analysis. The evaporator and gas cooler temperatures are varied from ?55°C to 5°C and 35°C to 60°C, respectively. The effects of various operating and design parameters on the optimum heat rejection pressure, coefficient of performance (COP), exergy loss (irreversibility), and the exergetic efficiency are studied. Exergy analysis of each component in TCEV and TCVT is performed to identify the amount and locations of irreversibility. It is observed that the use of the vortex tube in place of the expansion valve reduces the total exergy losses and increases the exergetic efficiency as well as COP. The exergetic efficiency and COP of the TCVT are on average 10–12% higher compared to TCEV for the considered operating conditions. The computed values of the exergetic efficiency for TCVT using refrigerant N2O are the highest at an evaporator temperature of ?55°C, and the corresponding values of exergetic efficiency and exergy losses varies between 25.35% and 15.67% and between 74.65% and 84.33%, respectively. However, COP at the same evaporator temperature of ?55°C varies between 0.83 and 0.51. Furthermore, the optimum heat rejection pressure in TCVT is lower compared to that in TCEV. The results offer significant help for the optimum design and operating conditions of TCVT with refrigerant N2O.  相似文献   

12.
The chilled ammonia process absorbs the CO2 at low temperature (2–10 °C). The heat of absorption of carbon dioxide by ammonia is significantly lower than for amines. In addition, degradation problems can be avoided and a high carbon dioxide capacity is achieved. Hence, this process shows good perspectives for decreasing the heat requirement. However, a scientific understanding of the processes is required. The thermodynamic properties of the NH3–CO2–H2O system were described using the extended UNIQUAC electrolyte model developed by Thomsen and Rasmussen in a temperature range from 0 to 110 °C and pressure up to 100 bars. The results show that solid phases consisting of ammonium carbonate and bicarbonate are formed in the absorber. The heat requirements in the absorber and in the desorber have been studied. The enthalpy calculations show that a heat requirement for the desorber lower than 2 GJ/ton CO2 can be reached.  相似文献   

13.
In this communication, a new design of solar-energy-based water distillation cum drying unit with parabolic reflector has been designed, fabricated, and tested. Bitter gourd and potato slices are chosen as a drying commodity. Thermal performance of the developed system has been evaluated based on the experimental results and using linear regression analysis. Heat transfer coefficients (convective, evaporative, and radiative) for solar distillation system have been observed to be 2.48–4.09, 13.25–52.38, and 8.75–9.66 W/m2°C, respectively. Overall thermal efficiency and exergy efficiency for the distillation system has been found to be 18.77% and 1.2%, respectively. The convective heat transfer coefficient for potato slices are observed higher for initial hours and decreases as the day progresses. The average convective heat transfer coefficients for bitter gourd and potato slices have been observed as 2.18 and 5.04 W/m2°C, respectively. Experimental error in terms of percent uncertainty for bitter gourd and potato slices are found to be 42.93% and 37.06%, respectively. The present design of solar distillation and drying in a single unit could be beneficial for the development of remote, arid, and rural areas.  相似文献   

14.
Abstract: A numerical model has been developed to simulate the hydraulic and heat transfer properties of a stormwater detention pond, as part of a simulation tool to evaluate thermal pollution of coldwater streams from stormwater runoff. The model is dynamic (unsteady) and based on principles of fluid mechanics and heat transfer. It is driven by hourly weather data, and specified inflow rates and temperatures. To calibrate and validate the pond model field data were collected on a commercial site in Woodbury, Minnesota. The relationship between pond inflow and outflow rates to precipitation was effectively calibrated using continuously recorded pond levels. Algorithms developed for surface heat transfer in lakes were found to be applicable to the pond with some modification, resulting in agreement of simulated and observed pond surface temperature within 1.0°C root mean square error. The use of an unshaded pond for thermal mitigation of runoff from paved surfaces was evaluated using the pond model combined with simulated runoff from an asphalt parking lot for six years of observed rainfall events. On average, pond outflow temperature was 1.2°C higher than inflow temperature, but with significant event‐to‐event variation. On average, the pond added heat energy to runoff from an asphalt parking lot. Although the pond added total heat energy to runoff, it did reduce the rate of heat outflow from the pond by an order of magnitude due to reductions in volumetric outflow rate compared with the inflow rate. By reducing the rate of heat flow, the magnitude of temperature impacts in a receiving stream were also reduced, but the duration of impacts was increased.  相似文献   

15.
This study analyzed the wintertime surface heat exchange for the Inner Mongolia reach of the Yellow River, China, based on the data from the nearby weather station at Wulateqianqi. In this analysis, the solar radiation is based on the observed data. Other components of the surface heat flux, that is, long‐wave radiation, and evaporative and conductive heat fluxes, are calculated. The relative importance of the contributions of long‐wave radiation, conductive, and evaporative heat fluxes are in descending order. The air temperature is the most important meteorological factor to the total heat flux. Although the wind speed influences evaporative and conductive heat fluxes, it has the least correlation with the total heat budget. The heat exchange coefficient for the linearized surface heat exchange equation is 21.87 W/(m2 °C), which is comparable with published values in the regions of United States and Canada with similar latitudes.  相似文献   

16.
In the current investigation, raw biogas obtained from rural sectors was used as the alternative to gasoline fuel in the spark ignition (SI) engine. The performance and efficiency are mainly dependent on the combustion phasing for which “ignition timing” is an effective tool in a SI engine. Hence, the objective of the present work is to understand the effect of “variable ignition timing” for a biogas-fueled SI engine. For this purpose, a single cylinder, 4-stroke, SI engine of rated power 4.5 kW was operated with raw biogas at a compression ratio (CR) of 10. By maintaining a speed of 1650 rpm, the engine was operated in wide open (WOT) and part throttle (PT) mode with an equivalence ratio of 0.81 and 0.83, respectively. It was observed that the biogas fueled SI engine was found to be operative only within the ignition advance (IA) range of 33–47° CA bTDC both in WOT and PT conditions. The results showed optimal brake power (BP), brake thermal efficiency (BTE) and brake specific fuel consumption (BSFC) are achieved at 45° CA bTDC. The average peak cylinder pressure, neat heat release rate (NHRR) and mean gas temperature (MGT) are also observed to be maximum while CO and HC emission at this point of IA were found to be minimum. Due to controlled and complete combustion, CO2 and NOx concentration in the exhaust emission were found to be higher at this point of ignition timing.  相似文献   

17.
Hilliard completed several thermodynamic models in Aspen Plus® for modeling CO2 removal with amine solvents, including MEA–H2O–CO2. This solvent was selected to make a system model for CO2 removal by absorption/stripping. Both the absorber and the stripper used RateSep? to rigorously calculate mass transfer rates. The accuracy of the new model was assessed using a recent pilot plant run with 35 wt.% (9 m) MEA. Absorber loading and removal were predicted within 6%, and the temperature profile was approached within 5 °C. An average 3.8% difference between measured and calculated values was achieved in the stripper. A three-stage flash configuration which efficiently utilizes solar energy was developed. It reduces energy use by 6% relative to a simple stripper. Intercooling was used to reach 90% removal in the absorber at these optimized conditions.  相似文献   

18.
The objective of this study is to investigate the potential process for the removal of carbon dioxide (CO2) from flue gas using fundamental membrane contactor, which is a membrane gas absorption (MGA) system. The experiments consisted of microporous polyvinylidenefluoride (PVDF) flat sheet membrane with 0.1 μm (as module I) and 0.45 μm (as module II) pore size. 2-Amino-2-methyl-1-propanol (AMP) solution was employed as the liquid absorbent. The effect of AMP concentration was studied with variation in the range 1–5 M. In addition, the experiments were carried out with 10%, 20%, 30% and 40% gas ratio of CO2 to N2 and pure CO2 as well. Through contact angle measurement, membranes for module I and module II were obtained with CA values of around 130.25° and 127.77°, respectively. The mass transfer coefficients for module II are lower than those of module I for 1–5 M of AMP. Furthermore, the increase in CO2 concentration in the feed gas stream enhanced the CO2 flux as the driving force of the system was increased in sequence from 1 M to 5 M of AMP. However, after the particular percentage (40%) of CO2 inlet concentration, the CO2 fluxes seem saturated. The combination of AMP as liquid absorbent and PVDF microporous membrane in MGA system has shown the potential to remove the CO2 from flue gas. In addition, the higher AMP concentration gave higher mass transfer coefficient at low liquid flow rates.  相似文献   

19.
ABSTRACT

Stirling engines maintain attraction because of their high energy conversion efficiencies. In this study, experimental comparison of a beta-type Stirling engine for two different rhombic-drive mechanisms was presented. In one of the rhombic mechanisms, spur gears were used and the gear shaft was supported in bearings from one side. In the other mechanism, two helical gears were placed on crankshafts and the crankshafts were supported in bearings from both sides. Rhombus lengths of the mechanisms were determined as 66 mm and 80 mm to provide same constant compression ratio of 2.5 for both configurations. Both mechanisms were used in the same beta-type Stirling engine having same cylinder, piston and displacer dimensions. Performance parameters of the engines were evaluated at different helium charge pressures (2–4 bar) and hot-end temperatures (400–600°C). The hot-end of the displacer cylinder was heated by a liquefied petroleum gas (LPG) burner. The engine power increased by 132%, friction losses and gear noses were reduced by supporting the rhombic-drive mechanism from both side and using helical gears. The maximum output torque and power of the engine were obtained as 13.14 Nm at 428 rpm engine speed and 663 W at 800 rpm engine speed, respectively, at 600°C hot-end temperature and 4 bar charge pressure.  相似文献   

20.
Concentrated, aqueous piperazine (PZ) has been investigated as a novel amine solvent for carbon dioxide (CO2) absorption. The CO2 absorption rate of aqueous PZ is more than double that of 7 m MEA and the amine volatility at 40 °C ranges from 11 to 21 ppm. Thermal degradation is negligible in concentrated, aqueous PZ up to a temperature of 150 °C, a significant advantage over MEA systems. Oxidation of concentrated, aqueous PZ is appreciable in the presence of copper (4 mM), but negligible in the presence of chromium (0.6 mM), nickel (0.25 mM), iron (0.25 mM), and vanadium (0.1 mM). Initial system modeling suggests that 8 m PZ will use 10–20% less energy than 7 m MEA. The fast mass transfer and low degradation rates suggest that concentrated, aqueous PZ has the potential to be a preferred solvent for CO2 capture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号