首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sequencing batch reactor was modeled using multi-layer perceptron and radial basis function artificial neural networks (MLPANN and RBFANN). Then, the effects of influent concentration (IC), filling time (FT), reaction time (RT), aeration intensity (AI), SRT and MLVSS concentration were examined on the effluent concentrations of TSS, TP, COD and NH4+-N. The results showed that the optimal removal efficiencies would be obtained at FT of 1 h, RT of 6 h, aeration intensity of 0.88 m3/min and SRT of 30 days. In addition, COD and TSS removal efficiencies decreased and TP and NH4+-N removal efficiencies did not change significantly with increases of influent concentration. The TSS, TP, COD and NH4+-N removal efficiencies were 86%, 79%, 94% and 93%, respectively. The training procedures of all contaminants were highly collaborated for both RBFANN and MLPANN models. The results of training and testing data sets showed an almost perfect match between the experimental and the simulated effluent of TSS, TP, COD and NH4+-N. The results indicated that with low experimental values of input data to train ANNs the MLPANN models compared to RBFANN models are more precise due to their higher coefficient of determination (R2) and lower root mean squared errors (RMSE) values.  相似文献   

2.
The aim of this research was to upgrade the performance of a conventional septic tank (CST) for on-site treatment of sewage with negligible costs. Although CST is known as an inexpensive pre-treatment system, a complementary treatment is required to reuse its output effluent. In this work, the quality of treated wastewater reached to the standard level for irrigation by the innovational changes made in the structure of CST for converting it into an advanced septic reactor (ASR). The modification consists adding some pipe and trays without using any mechanical or electrical equipment.ASR was operated at ambient temperatures in laboratory and pilot-scale. The effects of up-flow velocities (Vup) of 0.4, 0.5, 0.7, 1 and 1.5 m/h and hydraulic retention times (HRT) of 36, 24 and 12 h on the ASR treatment performance were studied.For optimum Vup of 1 m/h and HRT of 24 h and biomass specific methanogenic activity (SMA) of 0.31 mg COD/g VSS d the maximum removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD5) and total suspended solids (TSS) were 86.2%, 79.4% and 95%, respectively.The results showed that ASR is an appropriate alternative for CST for sewage on-site treatment by a low cost modification.  相似文献   

3.
The start-up and operation of a partial nitritation sequencing batch reactor for the treatment of landfill leachate were carried out on intermittent aeration mode. Partial nitrite accumulation was established in 15 days after the mode was changed from continuous aeration to intermittent aeration. Despite the varying influent composition, partial nitritation could be maintained by adjusting the hydraulic retention time (HRT) and the air flow rate. An increase in the air flow rate together with a decrease in air off duration can improve the partial nitritation capacity and eventually result in the development of granular sludge with fine diameters. A nitrogen loading rate of 0.71 ± 0.14 kg/m3/d and a COD removal rate of 2.21 ± 0.13 kg/m3/d were achieved under the conditions of an air flow rate of 19.36 ± 1.71 m3 air/m3/h and an air on/off duration of 1.5 min/0.7 min. When the ratio of total air flux (TAF) to the influent loading rate (ILR) was controlled at the range of 163–256 m3 air/kg COD, a stable effluent NO3?–N/NOx?–N (NO2?–N plus NO3?–N) ratio below 13% was achieved. Interestingly, the effluent pH was found to be a good indicator of the effluent NO2?–N/NH4+–N ratio, which is an essential parameter for a subsequent anaerobic ammonium oxidation (Anammox) reactor.  相似文献   

4.
The aim of this research was to study the on-site anaerobic treatment of a medium-strength residential wastewater in a pilot-scale up-flow septic tank (UST). The effects of three different hydraulic retention times (HRTs) of 24, 12 and 6 h on the UST performance were investigated. The UST removed 85, 77, and 86% of biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and total suspended solids (TSS), respectively, at steady state operation and with a 24 h HRT. Decreasing the HRT to 12 and then 6 h resulted in deteriorated effluent quality and significantly reduced reactor performance. The sludge showed a high specific methanogenic activity (SMA) of 15.2 mL CH4 g?1 VSS d?1 with raw wastewater substrate. The solids accumulated in the tank by the end of the experiment had a VSS/TSS of 0.57, demonstrating significant stabilization. Overall, the UST is concluded to be a technically and economically promising alternative to conventional septic tanks for the on-site decentralized treatment of residential wastewater, particularly in the rural communities of developing countries.  相似文献   

5.
Produced water is a significant waste stream generated in association with oil and gas production. It contains high concentrations of hydrocarbon constituents and different salts. In this study, a membrane sequencing batch reactor (MSBR) was used to treat synthetic and real produced water. The MSBR was evaluated in terms of biodegradation of hydrocarbons in the synthetic produced water with various organic loading rates (OLR) (0.281, 0.563, 1.124, 2.248, and 3.372 kg COD/(m3 day)), cycle time (12, 24, and 48 h), and membrane performance. The effects of salt concentrations at different total dissolved solids (TDS) (35,000, 50,000, 100,000, 150,000, 200,000, and 250,000 mg/L) on biological treatment of the pollutants in the synthetic and real wastewater were studied. At an OLR of 1.124 kg COD/(m3 day), an HRT of 48 h and TDS of 35,000 mg/L, removal efficiencies of 97.5%, 97.2%, and 98.9% of COD, total organic carbon (TOC), and oil and grease (O&G), respectively were achieved. For the real produced water, removal rates of 86.2%, 90.8%, and 90% were obtained for the same conditions. However, with increasing salt content, the COD-removal efficiencies of the synthetic and real produced water were reduced to 90.4% and 17.7%, respectively at the highest TDS.  相似文献   

6.
In this research, treatability of high-load compost leachate in a hybrid expanded granular sludge bed (EGSB) and fixed-bed (FB) bioreactor followed by electrocoagulation–flotation (ECF) system was examined. The operational factors in EGSB–FB were influent chemical oxygen demand (COD), hydraulic retention time (HRT) and COD/nitrogen ratio (COD/N). And, their interactive effects on the efficiency of COD removal and biogas production rate (BPR) as responses were analyzed and correlated by response surface methodology (RSM). The optimum conditions of the hybrid EGSB–FB reactor were acquired at COD = 7800 mg/L, HRT = 35 h, COD/N = 70, in which COD removal efficiency was 83% and BPR 94 mL/h. The amount of confidence interval was 95%. COD (relevant coefficient = 9.8) and HRT (relevant coefficient = −24) were resulted respectively as the most effective parameters on COD removal and BPR. Yet, COD/N parameter imposed negative effect on COD removal and BPR in values less than about 100. The outcomes indicated that operated ECF as post-treatment in constant conditions (electrolysis time = 75 min, electrodes distance = 3 cm, voltage = 20 V) successfully satisfied discharge criteria in the most part of experimental domains.  相似文献   

7.
Biological control of odor gases has gained more attention in recent years. In this study, removal performance of a vertical bio-trickling filter inoculated with bacteria and fungi was studied. Bacteria and fungi were isolated from activated sludge in a sewage treatment plant. By adopting “three step immobilization method”, the bio-trickling filter could degrade pollutant immediately once hydrogen sulfide (H2S) passed. The optimal empty bed resident time was 20 s. The optimal elimination capacity was about 60 g H2S m?3 h?1 with removal efficiency of 95%. And the maximum elimination capacity was 170 g H2S m?3 h?1. Pressure drop was ranged between 5 and 15 mm H2O per bed over the whole operation. Removal efficiency was not affected obviously after terminating nutrient supply. The bio-trickling filter could recover back after shut down H2S gaseous and liquid supplies simultaneously. Microbial community structure in the bio-trickling filter was not changed significantly.Combining bacteria and fungi would be a better choice for inoculation into a bio-trickling filter because of the quickly degradation of H2S and rapid recovery under shut-down experiment. This is the first study attempting to combine bacteria and fungi for removal of H2S in a bio-trickling filter.  相似文献   

8.
Aluminium-based water treatment sludge was used as a coagulant for removing/recovering phosphate from the effluent of upflow anaerobic sludge blanket (UASB) reactor treating municipal wastewater. The effect of three variables, namely sludge dose, initial pH and fresh coagulant (poly-aluminium chloride, PACl) dose was studied using response surface methodology. About 87% phosphate removal could be obtained at the optimum conditions of sludge dose 13.8 g/L, initial pH 6, and fresh PACl dose 5.8 mg Al/L. In order to achieve a similar phosphate removal, a dose in the range of 30–40 mg Al/L of fresh PACl was required. The results suggest that water treatment sludge can be reused as a coagulant for post-treatment of UASB reactor effluent treating municipal wastewater and can be considered as a promising alternative for removing phosphate which can substantially reduce the consumption of fresh PACl. The sludge generated during this process could potentially be used in land application which results in recycling of phosphate.  相似文献   

9.
In this study, recalcitrant total phenol (TPh) and organic matter removal were investigated at olive mill wastewater (OMW) in sequential Coagulation and Fenton system. This study focused on different operational parameters such as pH, H2O2, and Fe2+ dosages, and [Fe2+]/[H2O2] ratios. The optimum conditions were determined as; pH = 3; [Fe2+] = 2.5 g/L; [Fe2+]/[H2O2] = 2.5. A higher treatment efficiency was achieved at sequential Coagulation and Fenton system (COD, 65.5%) and TPh, 87.2%), compared to coagulation process (COD, 51.4%; total organic carbon (TOC), 38.6% and total nitrogen (TN) 52.1%). This study demonstrated that the Coagulation and Fenton process has a potential for efficient removal of phenolic pollutants from wastewater.  相似文献   

10.
In this study, chemical oxygen demand (COD) was characterized as total organic constituents and the isolated humic substances (HS) were characterized as an individual organic contaminant in landfill leachate. It was found that the HS content of landfill leachate was 83.3%. The results of laboratory tests to determine the roles of HS in reducing the organic content of landfill leachate during Fenton process are presented. Furthermore, the performances of oxidation and coagulation of Fenton reaction on the removal of HS and COD from leachate were investigated. The change curves of HS removal were similar to those of COD. The HS removal was 30% higher than COD removal, which indicated that HS were mostly degraded into various intermediate organic compounds but not mineralized by Fenton reagent. The oxidation removal was greatly influenced by initial pH relative to the coagulation removal. The oxidation and coagulation removals were linear dependent with hydrogen peroxide and ferrous dosages, respectively. Ferrous dosage greatly influenced the coagulation removal of COD at low ratio ([H2O2]/[Fe2+] < 3.0), but not at extremely high ratio ([H2O2]/[Fe2+] > 6.0). The coagulation removal of HS was not affected obviously by oxidation due to both Fenton oxidation and coagulation remove high molecular weight organics preferentially. Higher temperature gave a positive effect on oxidation removal at low Fe2+ dosage, but this effect was not obvious at high Fe2+ dosage.  相似文献   

11.
Biodegradability enhancement of landfill leachate using air stripping followed by coagulation/ultrafiltration (UF) processes was introduced. The air stripping process obtained a removal efficiency of 88.6% for ammonia nitrogen (NH4–N) at air-to-liquid ratio of 3500 (pH 11) for stripping 18 h. The single coagulation process increased BOD/COD ratio by 0.089 with the FeCl3 dosage of 570 mg l?1 at pH 7.0, and the single UF process increased the BOD/COD ratio to 0.311 from 0.049. However, the combined process of coagulation/UF increased the BOD/COD ratio from 0.049 to 0.43, and the final biological oxygen demand (BOD), chemical oxygen demand (COD), NH4–N and colour of leachate were 1223.6 mg l?1, 2845.5 mg l?1, 145.1 mg l?1 and 2056.8, respectively, when 3 kDa molecular weight cut-off (MWCO) membrane was used at the operating pressure 0.7 MPa. In ultrafiltration process, the average solution flux (JV), concentration multiple (MC) and retention rate (R) for COD was 107.3 l m?2 h?1, 6.3% and 84.2%, respectively.  相似文献   

12.
Gray water treatment and reuse is an immediate option to counter the upcoming water shortages in various parts of world, especially urban areas. Anaerobic treatment of gray water in houses is an alternative low cost, low energy and low sludge generating option that can meet this challenge. Typical problems of fluctuating VFA, low pH and sludge washout at low loading rates with gray water feedstock was overcome in two chambered anaerobic biofilm reactors using natural fibers as the biofilm support. The long term performance of using natural fiber based biofilms at moderate and low organic loading rates (OLR) have been examined. Biofilms raised on natural fibers (coir, ridge-gourd) were similar to that of synthetic media (PVC, polyethylene) at lower OLR when operated in pulse fed mode without effluent recirculation and achieved 80–90% COD removal at HRT of 2 d showing a small variability during start-up. Confocal microscopy of the biofilms on natural fibers indicated thinner biofilms, dense cell architecture and low extra cellular polymeric substances (EPS) compared to synthetic supports and this is believed to be key factor in high performance at low OLR and low strength gray water. Natural fibers are thus shown to be an effective biofilm support that withstand fluctuating characteristic of domestic gray water.  相似文献   

13.
Rotating biological contactors (RBCs) for wastewater treatment began in the 1970s. Removal of organic matter has been targeted within organic loading rates of up to 120 g m−2 d−1 with an optimum at around 15 g m−2 d−1 for combined BOD and ammonia removal. Full nitrification is achievable under appropriate process conditions with oxidation rates of up to 6 g m−2 d−1 reported for municipal wastewater. The RBC process has been adapted for denitrification with reported removal rates of up to 14 g m−2 d−1 with nitrogen rich wastewaters. Different media types can be used to improve organic/nitrogen loading rates through selecting for different bacterial groups. The RBC has been applied with only limited success for enhanced biological phosphorus removal and attained up to 70% total phosphorus removal. Compared to other biofilm processes, RBCs had 35% lower energy costs than trickling filters but higher demand than wetland systems. However, the land footprint for the same treatment is lower than these alternatives. The RBC process has been used for removal of priority pollutants such as pharmaceuticals and personal care products. The RBC system has been shown to eliminate 99% of faecal coliforms and the majority of other wastewater pathogens. Novel RBC reactors include systems for energy generation such as algae, methane production and microbial fuel cells for direct current generation. Issues such as scale up remain challenging for the future application of RBC technology and topics such as phosphorus removal and denitrification still require further research. High volumetric removal rate, solids retention, low footprint, hydraulic residence times are characteristics of RBCs. The RBC is therefore an ideal candidate for hybrid processes for upgrading works maximising efficiency of existing infrastructure and minimising energy consumption for nutrient removal. This review will provide a link between disciplines and discuss recent developments in RBC research and comparison of recent process designs are provided (Section 2). The microbial features of the RBC biofilm are highlighted (Section 3) and topics such as biological nitrogen removal and priority pollutant remediation are discussed (Sections 4 Biological nutrient removal in RBCs, 5 Priority pollutant remediation in RBCs). Developments in kinetics and modelling are highlighted (Section 6) and future research themes are mentioned.  相似文献   

14.
The biological aerated filter (BAF) system, a new alternative in drinking water treatment, was designed to remove NH4+–N and Mn2+ simultaneously. This study aimed to control the aeration time in the BAF system for simultaneous NH4+–N and Mn2+ removal to achieve the Malaysian effluent quality regulation for drinking water. The experiment was conducted under four strategies of S1, S2, S3 and S4. The results demonstrated that acceptable levels of NH4+–N and Mn2+ were achieved over a 6 h aeration period (S1), producing effluent concentrations of 0.7 mg/L (93.2% removal) and 0.08 mg/L (79.6% removal), respectively. At the initial treatment of S1 and S2, the dissolved oxygen (DO) level rapidly increased until it reached a saturated concentration (6.8 mg/L DO) after 2 h period. Automatic on–off aeration time to maintain 3 mg/L DO set point (S4) resulted with a good effluent quality of NH4+–N and Mn2+ compared with the 2 mg/L DO set point (S3) which did not meet the regulated standard limits. Through the automatic on–off aeration time, the saturated and excessive DO levels in the BAF system can be avoided consequently reduce the wastage of energy and electrical consumption for simultaneous NH4+–N and Mn2+ removal from drinking water treatment.  相似文献   

15.
Biodegradation of toluene vapour was investigated for 168 days in a polyurethane packed biofilter inoculated with a mixed microbial population. Biofilter consisted of five square cross-section modular units each of size 0.16 m × 0.16 m × 0.20 m and filled with the polyurethane foam cubes up to a height of 0.15 m. Inlet concentration of toluene was varied from 0.04 to 2.5 g m?3 and the volumetric flow rate of toluene loaded air from 0.06 to 0.90 m3 h?1.Depending upon initial loading rates, removal efficiency ranging from 68.2 to 99.9% and elimination capacity ranging from 10.85 to 90.48 g h?1 m?3 were observed during steady state operations. More than 90% removal efficiency was observed up to an inlet loading rate of 76.3 g h?1 m?3. High carbon recovery (>90%) indicated effective biodegradation in the bed. Low variation of pH (7.2–8.8) and pressure drop (45.8–76.3 Pa) was observed. The stability of the biomass was evident from the fast response of the biofilter to shutdown and restartup.  相似文献   

16.
A biotrickling filter packed with coal slag as packing medium was continuously used for more than 9 months under high ammonia loading rates of up to 140 g/m3/h. Nitrogen mass balance and microbial community analysis were conducted to evaluate the inhibitory effects of high ammonia concentration and metabolic by-products on the rates of nitrification. Ammonia removal efficiency reached above 99% at an empty bed retention time of as low as 8 s when inlet concentrations were below 350 ppm. The maximum and critical elimination capacities of the biotrickling filter were 118 g/m3/h and 108.1 g/m3/h, respectively. Kinetics analysis results showed that less than 2.5 s was required for the biotrickling filter with pH control to treat ammonia at concentrations of up to 500 ppm in compliance with the Taiwan EPA standard (outlet NH3 < 1 ppm). Results of mass balance and microbial community analysis indicated that complete removal was mainly contributed by the activities of autotrophic ammonia oxidizing bacteria and not by physical absorption or adsorption at low loading rates. However, at high inlet loadings, ammonium became the dominant by-product due to inhibitory effects of high ammonia concentration on the bacterial community.  相似文献   

17.
Plastic was tested to select biofilm support media that would enhance nitrification in the presence of heterotrophs. Eight different types (acrylonitrile butadiene styrene, nylon, polycarbonate, polyethylene, polypropylene, polytetrafluoroethylene (PTFE), polyvinyl chloride and tufnol) were immersed in an aerobic fed-batch reactor receiving domestic settled wastewater. Nitrification rates did not correlate with biomass concentrations, nor surface roughness of the plastics as measured by atomic force microscopy (AFM). The maximum nitrification rate of 1.5 g/m2 d?1 was obtained from biofilms growing on PTFE which had the lowest surface adhesion force (8 nN). Nitrification rates for the biofilms were inversely correlated with the attraction forces as measured by AFM.  相似文献   

18.
Mixture of sewage sludge with organic garbage was alternatively composted by aerobic and anaerobic technology for 60 days. A basin-scale experiment was performed by planting watercress with kailyard (KY) soil amended with the compost. The results show that average total organic carbon (TOC) increases from 98.45% to 787.69%, and average total nitrogen (TN), total phosphorus (TP) and total potassium (TK) increases to 98.53%, 27.34%, and 41.62%, respectively. The results of watercress in 6 pot experiments with a control treatment show that biomass production increases from 76.47% to 312.00% with the increase of addition of compost from 50 g to 150 g per pot but decreases from 312.00% to 102.29% with the addition of compost to soil and further increases from 150 g to 400 g per pot. The optimal amount of compost added to KY soil is 0.4 g of compost 1 kg of KY soil. Heavy metals accumulated by watercress demonstrate that Cu, Ni, Cd, Pb, Cr, Zn in the crop are much lower than the limited levels of Chinese criteria for vegetables. KY soil is proper to be amended with compost of sewage sludge without threat of bio-magnification of heavy metals to planting watercress.  相似文献   

19.
In this study, pyrolysis of sugarcane bagasse was performed in fixed bed tubular reactor under the conditions of nitrogen atmosphere, by varying temperature and different particle sizes. The effect of final pyrolysis temperature from 400 to 500°C and the nitrogen flow rate from 50 to 200 cc min−1 on the pyrolysis product yields from sugarcane bagasse have been investigated. The Maximum bio-oil yield obtained is 24.12 wt% at the final pyrolysis temperature of 450°C, N2 flow rate of 50 cc min−1 and particle size of mesh number −8 + 12. The yield of bio-oil decreases with increase in temperature from 450 to 550°C and N2 flow rate from 50 to 200 cc min−1. The various characteristics of pyrolysis oil obtained under these conditions were identified on the basis of standard test methods. The empirical formula of pyrolysis oil with a heating value of 37.01 MJ Kg−1 was established as CH1.434 O0.555 N0.004. The results from the pyrolysis show the potential of sugarcane bagasse as an important source of liquid hydrocarbon fuel.  相似文献   

20.
Produced water is the largest wastestream of oil and gas exploration but its chemical composition hinders its beneficial use. Effective treatment and reuse of produced water can mitigate scarcity of fresh water, especially in arid areas. Presence of inorganic compounds such as boron in produced water renders its beneficial use difficult. In this study, boron removal from produced water was investigated. Synthetic wastewater was prepared simulating the range of boron concentrations in produced water. Four operating parameters pH (3–11), charge loading (1200–3600 Ah/m3), contact time (15–90 min) and concentration (10–30 mg/L) were selected and their optimum conditions investigated. The obtained optimum conditions were applied to treat real produced water. Residual boron concentration of 0.3 mg/L was obtained from initial boron concentration of 15 mg/L in real produced water at optimum conditions of pH 7, charge loading 2400 Ah/m3 and contact time 90 min. Boron adsorption could be represented by Langmuir and Freundlich isotherm models. Electrocoagulation can be used for the effective removal of boron from produced water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号