1.
Excessive nutrient loading (considering nitrogen and phosphorus) is a major ongoing threat to water quality and here we review the impact of nutrient discharges from wastewater treatment plants (WWTPs) to United States (U.S.) freshwater systems. While urban and agricultural land uses are significant nonpoint nutrient contributors, effluent from point sources such as WWTPs can overwhelm receiving waters, effectively dominating hydrological characteristics and regulating instream nutrient processes. Population growth, increased wastewater volumes, and sustainability of critical water resources have all been key factors influencing the extent of wastewater treatment. Reducing nutrient concentrations in wastewater is an important aspect of water quality management because excessive nutrient concentrations often prevent water bodies from meeting designated uses. WWTPs employ numerous physical, chemical, and biological methods to improve effluent water quality but nutrient removal requires advanced treatment and infrastructure that may be economically prohibitive. Therefore, effluent nutrient concentrations vary depending on the particular processes used to treat influent wastewater. Increasingly stringent regulations regarding nutrient concentrations in discharged effluent, along with greater freshwater demand in populous areas, have led to the development of extensive water recycling programs within many U.S. regions. Reuse programs provide an opportunity to reduce or eliminate direct nutrient discharges to receiving waters while allowing for the beneficial use of reclaimed water. However, nutrients in reclaimed water can still be a concern for reuse applications, such as agricultural and landscape irrigation.  相似文献   

2.
Governmental agencies, nongovernmental organizations, and agricultural organizations promote water quality trading programs as an innovative policy to engage agricultural producers in conservation activities. Cost analyses suggest regulated sources can reduce compliance costs by purchasing agricultural nonpoint source credits. Yet, such “point‐nonpoint” trades are rare. This article assesses the demand for agricultural nonpoint sources in well‐developed nutrient trading programs in Virginia for industrial and municipal wastewater treatment plants, municipal stormwater programs, and land developers. Evidence suggests nutrient trading programs in Virginia will not stimulate investments in pollutant reduction practices on working agricultural lands. The lack of demand for agricultural nonpoint source credits can be attributed to a substantial degree to the design features and incentives present in multiple overlapping regulatory programs. The legal setting that dampens regulated source demand for nonpoint source credits in Virginia is broadly representative of conditions found elsewhere in the United States.  相似文献   

3.
The aim of present study was to investigate the quality of the produced effluent from different units of the Iran Central Iron Ore in Bafq city and comparison of effluent with the standards. This study presents the physicochemical and biological parameters data of effluent of three Sequencing batch reactors (SBR) with a capacity of 160 m3?d?1. Most common parameters include pH, total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP), biochemical oxygen demand (BOD5), chemical oxygen demand (COD), heavy metals, and total coliforms and fecal coliforms as biological indicators. Then, for each SBR system, the average of each parameter was determined, and results were compared with the standard recommended by the Iranian Environmental Protection Agency. Based on the results, some of the parameters, including BOD5, COD, and TSS in the wastewater treatment plant (WWTP) effluent, are higher than the permitted amount for discharge to the surface water. Considering the BOD5, COD, and TSS concentration in WWTPs, the treated wastewater is only suitable for agricultural and irrigation use. Therefore, wastewater produced by Iran Central Iron Ore Co. will need additional treatment to achieve standard quality of water before discharge in surface water and adsorbent well.  相似文献   

4.
Wastewater Reuse Practices in Kuwait   总被引:1,自引:0,他引:1  
Water is a scarce commodity in Kuwait. With rapid growth of population coupled with increasing urbanization and agriculture, the demand for water in Kuwait is continually on the increase. The main water source in the country is from desalination with small quantities from underground aquifers. Wastewater effluent at least for irrigation purposes, could be a valuable source to augment this dwindling water supply, and should not continue to be wasted. Reuse of wastewater effluent could both minimize the disposal of water to the environment and reduce the demand on fresh water supplies. This paper discusses the features of reuse, the processes used and standards adopted. Design data, operational results, and physical characteristics for the three wastewater treatment plants (Ardiya, Jahra, and Riqqa) in Kuwait are discussed. In addition, the paper reports on the results of a research study undertaken to determine the willingness, level of awareness and knowledge among the people of Kuwait in using wastewater effluent for different purposes. Cost and benefit analyses were conducted on wastewater effluent and reuse. The study concludes with useful recommendations to both the authorities and the citizens of Kuwait.  相似文献   

5.
ABSTRACT There are several possible ways in which wastewater from municipalities may be reclaimed and reused so as to minimize the need for imported water in North Central Texas. The rationale for reuse is enhanced by the fact that new water quality requirements in the Trinity River system will necessitate a very high degree of treatment at municipal sewage plants, just for discharge to surface streams. The largest potential market for municipal effluent is the steam-electric power industry. Within the next decade the generating capacity for electric power in North Central Texas will have to be more than doubled to meet increasing demand. Adequate supplies of condenser cooling water for such expansion will be difficult to obtain and assure. New large power stations might advantageously be located adjacent to municipal wastewater treatment plants, to utilize effluent as make-up water for cooling towers. Experience elsewhere has shown that well-treated wastewater can be used for cooling tower make-up with a minimum of trouble, with a considerable saving in overall cost, and with conservation of pristine water for other uses.  相似文献   

6.
中原油田产生的钻井污水的化学需氧量(COD)、矿化度、色度、悬浮物及含油量均比较高,直接外排将会对周边生态环境造成污染,与采油污水混合处理又将导致处理后的水质达不到标准,因而采用将钻井污水处理后再与采油污水混合的方法,这种混合污水进入采油污水处理系统的试验结果表明,处理后的钻井污水与采油污水配伍性良好,净化水无结垢倾向,处理后的净化水与杀菌剂、缓蚀剂相容性良好,其主要指标均达到部颁注水水质标准。  相似文献   

7.
In Ireland, no database detailing the design, influent loading rates or performance of constructed wetlands (CWs) exists. On account of this, they are designed without any protocol based on empirical data. The aim of this paper was to provide the first published data on the performance of free-water surface flow (FWSF) CWs treating primary and secondary-treated municipal wastewater, and agricultural dairy soiled water (DSW) in Ireland. In total, the performance of thirty-four FWSF CWs, comprising fourteen CWs treating primary-treated municipal wastewater, thirteen CWs treating secondary-treated municipal wastewater, and seven CWs treating DSW, were examined. In most CWs, good organic, suspended solids (SS) and nutrient removal was measured. At an average organic loading rate (OLR) of 10 and 9 g biochemical oxygen demand (BOD) m(-2) d(-1), CWs treating primary and secondary wastewater removed 95 and 84% of influent BOD. Constructed wetlands treating DSW had an average BOD removal of 98%. At average SS loading rates of 6 and 14 g m(-2) d(-1), CWs treating primary and secondary wastewater had a 96 and an 82% reduction, and produced a final effluent with a concentration of 14 and 13 mg L(-1). Constructed wetlands treating DSW produced a final effluent of 34 mg L(-1) (94% reduction). Similar to other studies, all CWs examined had variable performance in ammonium-N (NH(4)(+)-N) removal, with average removals varying between 37% (for CWs treating secondary wastewater) and 88% (for CWs treating DSW). Variable ortho-phosphorus (PO(4)(3-)-P) removal was attributable to different durations of operation, media types and loading rates.  相似文献   

8.
ABSTRACT: The increased agricultural efficiency of the American farmer has been a substantial impetus to this nation's rapid urbanization. In many western regions where total water supplies are limited, urbanization has required the transfer of heretofore agricultural water rights to the urban use. A major problem in such transfers has been the value or price of the water. A management level model of a typical urban water system was developed to optimize water supply, distribution, and wastewater treatment alternatives. The values of agricultural transfers were determined as the cost advantages of increasing allowable reuse levels of urban effluents which imply the use of a downstream right. This procedure is justified by the economic theory of alternative cost. Results for a test application to the Denver, Colorado area indicate values on the order of $1,000 per acre-foot of transferable water depending on effluent water quality restrictions and operational policies.  相似文献   

9.
As the demand for water in cities increases, the quantity of wastewater being produced is growing at a phenomenal rate. If resources are to be managed effectively, a new paradigm is required for urban wastewater management. This paper reviews the initial findings of a participatory action planning process for managing wastewater for agricultural use. It finds that such processes need considerable facilitation, capacity building and knowledge sharing, but that if a plan can be devised that meets the needs of the stakeholders, even if some compromise is required, then certain stakeholders are likely to take responsibility for specific aspects. This may not meet the entire integrated water resources management (IWRM) vision of the plan but provided the plan is developed in such a way that incremental implementation will be beneficial then this will produce some success and may stimulate further cooperation.  相似文献   

10.
Estrogenic activity of regional water samples was evaluated. Samples obtained from wetlands and ponds involved in various agricultural land uses, from three river sites over four seasons, and from municipal wastewater effluent held in storage lagoons were evaluated. The estrogen-responsive cell line MCF-7 BOS was used in the E-screen assay to determine 17beta-estradiol equivalents (E2 Eq) of water samples extracted by solid-phase extraction. Estrogenic activity in surrounding wetlands and ponds from different land uses was not different, with 10(-12) M E2 Eq (0.3 ppt). Estrogenic activity of Red River samples was within the same range as wetland-pond samples. The highest activity was found downstream from municipal wastewater treatment effluent discharge sites, in winter when river flow was lowest (approximately 6 x 10(-13) M E2 Eq). Results showed that 7 of 20 wetland-pond samples and 5 of 12 river samples were below the limits of quantitation (approximately 3 x 10(-14) M E2 Eq). Toxicity was found in fall and summer river samples upstream from municipal wastewater release sites. The timing of toxicity did not coincide to the presence of elevated fecal coliforms. Estrogenic activity in wastewater effluent from lagoons decreased over time (approximately 25 to 5 x 10(-13) M E2 Eq) with an apparent half-life of 8 d for one lagoon. The median concentration of detectable estrogenic activity in regional water samples was approximately 50-fold less than the median 17beta-estradiol concentration of estradiol detected in some U.S. streams in previous studies.  相似文献   

11.
Overland flow (OF) systems were evaluated and compared for advanced treatment of municipal and industrial effluents, including nutrients and nondegradable chemical oxygen demand (COD) removal. Three pilot plants were constructed at the Shahin Shahr Wastewater Treatment Plant (WWTP), Isfahan, Iran. Each pilot was assigned a specific wastewater and all were simultaneously operated for 8 months. Treatment of primary effluent, activated sludge secondary effluent, and lagoon effluent of textile wastewater was investigated at application rates (ARs) of 0.15, 0.25, and 0.35m(3)m(-1)h(-1). During 5 months of stable operation after a 3-month acclimation period, mean removals of total 5-day biochemical oxygen demand (TBOD(5)), total COD (TCOD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and turbidity were 74.5%, 54.8%, 66.2%, 39.4%, 35.8%, and 67.7% for primary effluent; 52.9%, 52.9%, 66.5%, 44.4%, 39.8%, and 50.1% for activated sludge effluent; 65.7%, 58.7%, 70.3%, 41.7%, 41.3%, and 54.9% for textile wastewater lagoon effluent, respectively. The model of Smith and Schroeder, 1985. Field studies of the overland flow process for the treatment of raw and primary treated municipal wastewater. Journal of Water Pollution Control Federation 57, 785-794] was satisfactory for TBOD(5). For all treatment parameters a standard first-order removal model was inadequate to represent the data but a modified first-order model provided a satisfactory fit to the data. Based on the results of this study, it can be concluded that an OF system as advanced treatment had the ability to meet effluent discharge permit limits and was an economical replacement for stabilization ponds and mechanical treatment options.  相似文献   

12.
Water quality trading (WQT) has the potential to be a low‐cost means for achieving water quality goals. WQT allows regulated wastewater treatment plants (WWTPs) facing discharge limits the flexibility to either reduce their own discharge or purchase pollution control from other WWTPs or nonpoint sources (NPSs) such as agricultural producers. Under this limited scope, programs with NPSs have been largely unsuccessful at meeting water quality goals. The decision to participate in trading depends on many factors including the pollution control costs, uncertainty in pollution control, and discharge limits. Current research that focuses on making WQT work tends to identify how to increase participation by traditional traders such as WWTPs and agricultural producers. As an alternative, but complementary approach, we consider whether augmenting WQT markets with nontraditional participants would help increase the number of trades. Determining the economic incentives for these potential participants requires the development of novel benefit functions requiring not only economic considerations but also accounting for ecological and engineering processes. Existing literature on nontraditional participants in environmental markets tends to center on air quality and only increasing citizen participation as buyers. Here, we consider the issues for broadening participation (both buyers and sellers) in WQT and outline a multidisciplinary approach to begin evaluating feasibility.  相似文献   

13.
对己内酰胺生产过程废水的回用处理工艺进行了研究。以某己内酰胺化工厂的LUCAS出水作为研究对象,采用膜生物反应器和反渗透膜处理工艺,研究此系统对己内酰胺废水的处理效果。试验结果表明,膜生物反应器工艺适用于该化工厂的生产废水,出水COD平均值为31.33mg/L,平均浊度为0.2NTU,氨氮平均值为2.81mg/L,可以满足反渗透膜的进水要求。在浓缩倍数为3时,反渗透膜系统运行稳定,且产水可以满足化工部循环冷却水用再生水水质标准。  相似文献   

14.
污水深度处理后回用不仅节约水资源,也减少了大量污染物的排放,是一项一举多得的益事。秦皇岛港污水深度处理回用工程利用城市二级处理的污水,经深度生物处理后用于煤炭除尘,解决了除尘水源紧张的局面。本文就如何确定回用工程的出水水质指标及其标准进行了讨论,阐述了制定出水水质标准的基本原则。  相似文献   

15.
Regeneration studies of wastewater effluent from an organized industrial district (OID) for possible reuse in textile industry as process water was investigated. Advanced treatment methods including Fenton process, polyaluminium chloride (PAC) coagulation and ion exchange were applied on OID effluent. In Fenton process removal efficiencies for suspended solids (SS), chemical oxygen demand (COD), SAC436 (spectral absorption coefficient), SAC525 and SAC620 were determined 61%, 36%, 35%, 49% and 67%, respectively. After Fenton process, wastewater samples were coagulated with PAC. Optimum removal efficiencies for SS, COD, Fe ion, SAC436, SAC525 and SAC620 were determined 83%, 18%, 93%, 32%, 36% and 58%, respectively. Ion exchange experiments were conducted on chemically coagulated wastewater samples to improve the quality of wastewater. Optimum dosage of resins was determined. The experiments revealed that 1:1 resin ratio (20 mL H-type resin:20 mL OH-type resin) gave the best removal rates for the parameters considered in this study. Study results indicated that quality of the wastewater was suitable for the process water characteristics of textile industry and unit wastewater treatment cost was determined as 2.54 €/m3.  相似文献   

16.
ABSTRACT: The Tucson area is totally dependent on ground water, which is in increasingly short supply due to excessive overdrafts. Tucson area waste water treatment plants discharge material quantities of secondary effluent downstream, which is lost to evapotranspiration and recharge of the ground water basin. The city and the four large mining companies who share the common Santa Cruz basin ground water, recognized the common water supply problem and agreed to fund a feasibility study for mining process use of the effluent to partly alleviate the overdraft of ground water. The study analyzed the projected waste water effluent resources, potential mining company demand for waste water effluent and possible interface of an effluent delivery facility with the proposed Central Arizona Project. The effluent resources were analyzed with respect to potential demand. An optimum alignment was selected. An optimum system was detailed through design schematics, amortized cost and finance requirements, and an implementation schedule. It was concluded that a waste water effluent delivery facility could be implemented which would utilize reclaimed effluent in quantities approximating 35 percent of basin overdraft and which would provide revenue for full cost recovery over a 20 year operation period. The mining companies are studying the internal economic impacts of the project.  相似文献   

17.
Treated wastewater from a food-processing plant, together with intermittent outflow from a hypereutrophic pond, were discharged over a 20-year period to a cattail-dominated wetland and hence to a small stream. Organics and nutriet levels in the effluent were comparable to levels in domestic wastewater. Fifteen variables were monitored upstream and downstream from the plant over 18 months. Means for most variables were slightly higher downstream, but differences between stations were not statistically significant. Wetland processing of nitrogen was markedly affected by a change from drought to flood conditions. After accounting for dilution, the overall effect of the wetland on the effluent was to reduce biological oxygen demand 43.7%, ammonia N 46.3%, nitrate/nitrite N 17.4%, and conductivity 15.6%. However, total suspended solids were increased 41.4%, total organic nitrogen 28.8%, and total phosphorus 24.7%. It was concluded that the wetland effectively renovated the effluent but the removal efficiency would be improved if the effluent were pretreated to reduce phosphorus and dispersed to increase residence time in the wetland.  相似文献   

18.
Treatment of chemical industrial wastewater from building and construction chemicals factory and plastic shoes manufacturing factory was investigated. The two factories discharge their wastewater into the public sewerage network. The results showed the wastewater discharged from the building and construction chemicals factory was highly contaminated with organic compounds. The average values of chemical oxygen demand (COD) and biochemical oxygen demand (BOD) were 2912 and 150 mgO2/l. Phenol concentration up to 0.3 mg/l was detected. Chemical treatment using lime aided with ferric chloride proved to be effective and produced an effluent characteristics in compliance with Egyptian permissible limits. With respect to the other factory, industrial wastewater was mixed with domestic wastewater in order to lower the organic load. The COD, BOD values after mixing reached 5239 and 2615 mgO2/l. The average concentration of phenol was 0.5 mg/l. Biological treatment using activated sludge or rotating biological contactor (RBC) proved to be an effective treatment system in terms of producing an effluent characteristic within the permissible limits set by the law. Therefore, the characteristics of chemical industrial wastewater determine which treatment system to utilize. Based on laboratory results engineering design of each treatment system was developed and cost estimate prepared.  相似文献   

19.
Assessing groundwater resources in the arid and semiarid borderlands of the United States and Mexico represents a challenge for land and water managers, particularly in the Transboundary Santa Cruz Aquifer (TSCA). Population growth, residential construction, and industrial activities have increased groundwater demand in the TSCA, in addition to wastewater treatment and sanitation demands. These activities, coupled with climate variability, influence the hydrology of the TSCA and emphasize the need for groundwater assessment tools for decision‐making purposes. This study assesses the impacts of changes in groundwater demand, effluent discharge, and climate uncertainties within the TSCA from downstream of the Nogales International Wastewater Treatment Plant to the northern boundary of the Santa Cruz Active Management Area. We use a conceptual water budget model to analyze the long‐term impact of the different components of potential recharge and water losses within the aquifer. Modeling results project a future that ranges from severe long‐term drying to positive wetting. This research improves the understanding of the impact of natural and anthropogenic variables on water sustainability, with an accessible methodology that can be globally applied.  相似文献   

20.
Wastewater treatment facilities in tourist areas, in comparison to other municipal facilities, require specific configurations and additional management actions in order to achieve a reliable and cost-effective treatment. For example, the same facility operates during winter with minimum flows and in summer with peak flows. Moreover, careful effluent management is required to minimize environmental impact and health effects on tourists. In this study, effluent management data, including quantitative and qualitative effluent characteristics, reuse, and economic aspects of the Hersonissos Wastewater Treatment Plant (WTP) in Greece, are discussed. It has been designed to treat both municipal wastewater from the Hersonissos Municipality and septage from the wider area. Analysis of effluent quantitative data showed two flow peaks in the summer period and only one in winter. The WTP was found to provide a reliable level of treatment in terms of biochemical oxygen demand (95.9%), total suspended solids (97.2%), and total nitrogen (87.7%) removal, but increased numbers of fecal coliforms were measured at some peak flow periods, suggesting the need for additional management strategies. Effluent is reused mainly for agricultural irrigation; secondary uses include fire protection and landscape irrigation. Economic analysis showed that for each cubic meter treated, the total annual economic cost for treatment, filtration, and reuse infrastructure was 1.07 €, 0.05 €, and 0.08 €, respectively.  相似文献   