首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Environmental pollution with polycyclic aromatic hydrocarbons (PAHs) from pyrogenic or petrochemical sources is a matter of concern in many aquatic ecosystems. For field monitoring purposes, PAH metabolite levels in fish bile samples can be used as biomarkers of exposure, but previously there were no reference materials for analytical method validation or quality control. In this paper we describe the preparation and certification of two fish bile materials. BCR 720 is a pure bile material from sediment-exposed flounder (Platichthys flesus) and BCR 721 is a pure bile material from oil-exposed plaice (Pleuronectes platessa). Homogeneity and stability tests were carried out and a group of 12 expert laboratories was assembled for the certification measurements. The methods applied were liquid chromatography with fluorescence detection or gas chromatography with mass spectrometric detection. In BCR 720 three PAH metabolites were certified: 1-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenzo[a]pyrene. In BCR 721 1-hydroxypyrene was certified. The fourth target compound, 2-hydroxynaphthalene, could not be certified, but the results obtained are listed. The major findings from earlier feasibility studies and recommendations for the optimal use of the reference materials are also included.  相似文献   

2.
A method using GC-MS and derivatization with N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) was developed for the analysis of 20 phenolic compounds in atmospheric samples (gas and particles). Air sampling was carried out using a Hi-Vol sampler with glass fibre filter and XAD-2 resin at a flow rate of 60 m(3) h(-1). The particle and gas phases were collected separately over a period of 4 h. Samples were Soxhlet extracted, evaporated to dryness under nitrogen and refilled with acetonitrile. 100 microl of these extracts were derivatized with 100 microl of MTBSTFA at 80 degrees C for 1 h under strong stirring. Phenolic compounds were injected into a GC-MS in splitless mode and quantified as their TBDMS derivatives in the SIM mode. Mass spectral analysis of the derivatives of the 20 compounds studied indicates that the spectra are highly specific showing an ion at [M - 57]+ which is useful for structure confirmation or analysis at low levels using selected ion monitoring. Quantification limits varied between 5 microg l(-1) and 10 microg l(-1) which correspond to 20 pg m(-3) and 40 pg m(-3) for 250 m(3) of air sampled. This method was successfully applied to atmospheric samples.  相似文献   

3.
A GC-MS method for the quantification of bacterial lipopolysaccharides (LPS, endotoxin) is presented. After hydrolytic cleavage of 3-hydroxy fatty acids (3-OH FAs) from the lipid A region of LPS, derivatisation of both the hydroxyl and the carboxyl group was performed in one step with a mixture of methyl-bis(trifluoracetamide)(MBTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBSTFA). Using GC-MS in the EI mode with selected ion monitoring (SIM) for analysis, baseline separation of 3-OH FAs (and of possibly interfering 2-OH FAs) was achieved. The sensitivity of the method (LOD 7-50 pg/injection for the different 3-OH FAs investigated) allows for the efficient quantification of LPS in occupational and environmental samples. Degradation of 3-OH FAs as well as of their derivatives during sample preparation and GC-MS separation as a possible source of errors in analytical methods based on 3-OH FA determination is reported for the first time. Thermal elimination of water from the underivatised 3-OH FAs and of trifluoroacetic acid from the derivatives was identified as the cause of degradation. The resulting alpha,beta-unsaturated compounds showing the same mass spectra as the 3-OH FA derivatives were detected as more or less prominent satellite peaks. By using alkaline instead of acidic hydrolysis and cool on-column instead of split/splitless injection, elimination was reduced to an acceptable level.  相似文献   

4.
The concentrations of fifteen PAH compounds in samples of sediment and blue mussel tissue (Mytilus trossulus) were measured. In addition, the biliary polycyclic aromatic hydrocarbon metabolites present in flounder (Platichthys flesus) were analysed. Two methods were used in the analysis of PAH metabolites; high performance liquid chromatography (HPLC) and fixed wavelength fluorescence (FF). The major PAH metabolite which could be measured using the HPLC method was 1-OH pyrene. It was possible to detect 1-OH Phe and 3-OH B[a]P in 70 and 24 samples respectively, of the 87 samples analysed. However, the concentrations of 1-OH Phe and 3-OH B[a]P were below or near to the LOQ (0.002 μg ml(-1) bile). The bile of flounder samples from the Gulf of Gdańsk had 1-OH Pyr concentrations which ranged from 0.019 to 0.066 μg ml(-1) bile. The high linear correlation observed between the quantity of 1-OH pyrene determined by the HPLC-F method and the content of the sum of pyrene-type PAHs obtained by the FF method indicated the FF method of determination of pyrene-type PAH metabolites can be used as a screening method. The content of ∑(15)PAHs in sediments collected in the Gulf of Gdansk, in 2008, ranged from 29.3 to 103 μg kg(-1) dw. In mussel tissue ∑(15)PAHs concentrations were between 173.2 μg kg(-1) dw and 237.7 μg kg(-1) dw. All concentrations measured in the current study, in mussel tissue, were below the OSPAR toxicity threshold values.  相似文献   

5.
During recent years, the awareness of quality assurance and quality control in environmental analyses has constantly increased, especially due to the implementation of new guidelines and regulations at both the national and international level. Achieving comparable results by using certified reference materials is one of the primary concerns of the scientific community. As a result, there is a growing demand for certified reference materials to cover different matrices and pollutants. Moreover, these CRMs should be in close relationship to the determinants and target concentrations required by environmental bodies and European Directives as well. Supplementary information to this paper presents an inventory of reference materials available on the market from different suppliers against the priority pollutants listed in the Water Framework Directive. These CRMs cover matrices such as water, sediment and biota. The use of CRMs in relationship to appropriate analytical methods and relevant determinants is discussed and the need for matrix-CRMs, particularly for organic pollutants is emphasised. The use of proficiency testing schemes as an alternative for the lack of appropriate CRMs and future trends in the production of CRMs within the BCR framework are also discussed.  相似文献   

6.
A new method, based on separation with gas chromatography and detection with a quartz crystal microbalance, was used for the quantification of ethane-1-thiol, propane-1-thiol, ethyl methyl sulfide, propane-2-thiol, butane-2-thiol and butane-1-thiol. The analytical error, the analysis time and the general analytical performance are identical for gas chromatography-mass spectrometry (GC-MS) and gas chromatography-quartz crystal microbalance (GC-QCM). However, the GC-QCM method constitutes a low cost alternative to GC-MS for monitoring individual sulfur compounds in landfill gas. It is an easily assembled apparatus made with an injection device, a furnace, a column, a crystal cell and a quartz crystal.  相似文献   

7.
A method for the determination of polycyclic aromatic hydrocarbons (PAHs) in air particulates using microwave-assisted solvent extraction (MASE) coupled to a microwave extraction system (MES) is proposed. During the period of August to October, 1994, Singapore was enveloped by haze caused by forest fires in Sumatra, Indonesia. Air sampling were carried out during September and October; the determination of ambient air PAH levels in Singapore was undertaken. PAH analysis by GC-MS provided excellent sensitivity, linearity of quantitation, peak identification. This technique was evaluated using certified reference materials (CRMs) HS-4 and HS-6. Good recoveries of PAHs (>73.3%) were obtained for both CRMs. The MASE technique using MES is suitable for the determination of PAH levels in ambient air with no clean-up step required.  相似文献   

8.
Organochlorine pesticide (OCP) cycling was studied in the area of Banja Luka, Bosnia and Herzegovina, over 3 days in summer with high temporal (4 h-means) and spatial (3 sites distanced 3-6 km) resolutions. Elevated levels of DDX compounds (i.e. o,p'- and p,p'-isomers of DDT, DDE and DDD, 44-74 pg m(-3) at the urban sites and 27 pg m(-3) as a background level), HCH (α-, β- and γ-isomers, 52-70 vs. 147 pg m(-3)), HCB (34-48 vs. <0.1 pg m(-3)) and pentachlorobenzene (6.8-9.9 vs. 6.0 pg m(-3)) were found. The variation of OCP levels at the two urban sites was not in phase, except for most DDX compounds. This was related to background levels, which for HCH were higher than in the urban area. Vertical profiles between samples collected from 1.1 and 2.3 m (part of the time 0.6 and 2.3 m) above a soil, which was only moderately contaminated by OCPs (0.12 ng g(-1) HCH, 0.11 ng g(-1) DDX, 0.44 ng g(-1) HCB) were analysed. Volatilisation from the ground caused negative vertical concentration gradients of HCH isomers (day and night), but not for HCB (except for 1 day-time sample) and DDX compounds (except p,p'-DDD, day-time, sporadically). The concentration in air and the vertical concentration gradient of the HCH isomers varied with air temperature (day-time maxima), while the variation of the HCB concentration was inversely related to air temperature and was determined by mixing (night-time maxima). α- and β-HCH were volatilised from soil throughout the three days, even during periods of cooling. Fugacity calculations, based on the absorption in soil organic matter as the process determining retention in soil, underestimated the volatilisation of β-HCH and p,p'-DDD. It is concluded that the representativeness of point measurements of OCPs in urban areas is limited by the spatial variability of soil contamination.  相似文献   

9.
The Standards, Measurements and Testing Programme (formerly BCR) of the European Commission proposed a three-step sequential extraction procedure for sediment analysis, following extensive expert consultations and two interlaboratory studies. This scheme was recently used to certify the extractable trace element contents of a sediment reference material (CRM 601). Although this procedure offers a means to ensure the comparability of data in this field, some difficulties concerning the interlaboratory reproducibility still remain, and a new project is currently being conducted to determine the causes of poor reproducibility in the extraction scheme. The final objective of the project is the certification of new sediment and soil reference materials for their extractable contents of Cd, Cr, Cu, Ni, Pb and Zn. This paper presents the results of a small-scale interlaboratory study, which aimed to test a revised version of the extraction schemes by comparing the original and the modified protocols using the CRM 601 sample. This work offers an improvement to the BCR sequential extraction procedure through intercomparison exercises. This improved procedure will allow the obtaining of CRMs to validate analytical data in the analysis of soils and sediments, and it will also facilitate comparability of data in the European Union.  相似文献   

10.
An effective and sensitive method for simultaneous analysis of malachite green (MG), enrofloxacin (ENFLX) and ciprofloxacin (CPFLX) by liquid chromatography-diode array detection with solid-phase extraction (SPE) is developed. The conditions of SPE and LC were investigated and optimised. The effective separation of these compounds was achieved using a ZY1104 C18 column (250 × 4.6 mm, 5 μm) with 20 mM tetrabutyl ammonium bromide (pH 3.0)-acetonitrile as mobile phase and gradient elution. The diode array detection was used at 278 nm for ENFLX and CPFLX and at 613 nm for MG. Under the optimal conditions, the method LOD values of MG, ENFLX and CPFLX were 0.01, 0.07 and 0.10 μg L(?-1) for fish farming water samples and 1.5, 10.5 and 15 μg kg(?-1) for fish feed samples, respectively. The relative recoveries of the three analytes were achieved to be 76.7-82.3% with the RSDs (n = 5) of 3.2-4.6% for spiked fish farming water samples and 78.8-93.7% with the RSDs (n = 5) of 3.1-4.8% for spiked fish feed samples.  相似文献   

11.
A method for determination of the climate gases CH4, CO2 and N2O in air samples and soil atmosphere was developed using GC-MS. The method uses straightforward gas chromatography (separation of the gases) with a mass spectrometric detector in single ion mode (specific determination). The gases were determined with high sensitivity and high sample throughput (18 samples h(-1)). The LOD (3sigma) for the gases were 0.10 micro L L(-1) for CH4, 20 microL L(-1) for CO2 and 0.02 microL L(-1) for N2O. The linear range (R2 = 0.999) was up to 500 microL L(-1) for CH4, 4000 microL L(-1) for CO2 and 80 microL L(-1) for N2O. The samples were collected in 10 mL vials and a 5 microL aliquot was injected on column. The method was tested against certified gas references, the analytical data gave an accuracy within +/-5% and a precision of +/-3%. The presence of < or = 10% by volume of C2H2 (often used experimentally to prevent N2 formation from N2O) did not interfere with detection for the targeted trace gases.  相似文献   

12.
Capillary microextractor (CME) in combination with a gas chromatograph-mass spectrometer (GC-MS) was employed for the determination of trace priority hazardous substances in water. Three groups of semivolatile organic compounds (SVOCs), i.e., chlorinated hydrocarbons, pesticides and polycyclic aromatic hydrocarbons (PAHs), were simultaneously determined. SVOCs were extracted from 7 mL of water samples on a 100 cm commercial gas chromatographic column (0.32 mm id x film thickness 0.25 microm, HP-5 capillary column) and eluted with only 3 microL of acetonitrile. The extractant was analyzed by GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range 10 ng L(-1) to 3.0 mg L(-1) with correlation coefficients (r) greater than 0.99 and low limits of detection ranged from 10 ng L(-1) to 1.0 mg L(-1). High recovery (more than 80%) was obtained with relative standard deviation less than 10%. The method was successfully applied for trace level analyses of SVOCs in water samples.  相似文献   

13.
In order to control the quality of butyl- and phenyltin compound determinations in sediment, the Standards, Measurements and Testing Programme (formerly BCR) of the European Commission has started a project, the final aim of which is to certify a freshwater sediment for its contents of a range of organotin compounds (mono-, di- and tributyltin, and mono-, di- and triphenyltin). The first part of this project involved an interlaboratory study which aimed to test the feasibility of preparation of candidate freshwater sediment reference material and to detect and remove most of the pitfalls observed in organotin determinations. This paper presents the main results of this interlaboratory study carried out prior to the certification campaign. The agreement obtained among laboratories for the six compounds determined was considered to reflect the state-of-the-art and was encouraging enough to decide upon the organisation of a certification campaign, which will be concluded in June 1999.  相似文献   

14.
The present study reports the first analysis of water pollutants in Sri Lankan waters using a suite of biomarkers in Nile tilapia (Oreochromis niloticus) residing in Bolgoda Lake which receives urban, industrial and domestic wastes from multiple sources. The fish were collected from the lake in the dry period (April 2005) and wet periods (September 2005, October 2006) and the levels of biomarkers viz. hepatic ethoxyresorufin O-deethylase (EROD), glutathione S-transferase (GST), metallothioneins, biliary fluorescent aromatic compounds, brain and muscle cholinesterases (ChE) were compared with those of the laboratory reared control fish and the fish obtained from a less polluted water body, Bathalagoda reservoir (reference site). The results revealed that biomarker levels of the fish collected from the reference site were not significantly different from the controls. Hepatic EROD and GST activities in fish from Bolgoda Lake were induced 4.2-16.6 folds and 1.4-3.3 folds respectively compared with the control fish. Analysis of bile in the lake fish revealed recent uptake of naphthalene, pyrene and benzo(a)pyrene type polycyclic aromatic hydrocarbons (PAHs). The induction of EROD activities in feral fish reflects the exposure of fish to aryl hydrocarbon receptor agonists including PAHs present as pollutants in the Bolgoda Lake. Cholinesterase activity in the fish inhabiting one sampling site of Bolgoda Lake was lower (22-40% inhibition) than the activity measured in the control fish indicating the presence of anticholinesterase pollutants in the area. Hepatic metallothionein levels in the lake fish were higher (1.9-3.2 folds) in comparison to the controls indicating metal exposure. The results support the potential use of these biomarkers in Nile tilapia in assessing pollution in tropical water bodies.  相似文献   

15.
Application of the dioxin responsive-chemical activated luciferase gene expression (DR-CALUX) bioassay to three compost products (kitchen garbage compost, treated sludge compost, and poultry manure compost) and their organic waste materials was performed for the screening of dioxin-like compounds. Phased sample preparation was conducted for the bioassay to yield separate crude, acid-stable, and carbon column fractions. Chemical analyses were also conducted for polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polyaromatic hydrocarbons (PAHs). Their determined WHO-PCDD/PCDF/dl-PCB-TEQ values were compared to the DR-CALUX results expressed as CALUX-TEQ to ascertain their contributions to overall activity. Overall all three compost products were polluted to a low level by persistent PCDD/PCDF/dl-PCBs in a few pg/g WHO-TEQ concentration range. The organic crude fraction showed non-persistent CALUX-TEQ values 2-4 orders of magnitude higher than those of WHO-TEQ. For the acid-resistant fractions of all samples, persistent CALUX-TEQ values were 1-8-fold higher than WHO-PCDD/PCDF/dl-PCB-TEQ values. Both TEQs correlated well for this fraction, which confirms the availability of CALUX for estimation of the actual WHO-TEQ level of the samples using reflux method with 44% sulfuric acid/silica gel, although the compost and material samples examined in this study contained much lower levels of WHO-TEQ: less than 1 pg/g in almost all cases. Additional carbon column treatment enhanced the potency and efficacy of CALUX activity in the three compost samples, which showed 1.6-4.4 times higher values of CALUX-TEQ than those obtained for the acid-resistant fraction. Although further DR-CALUX data collection for compost samples will be necessary, DR-CALUX is useful as a rapid screening method for monitoring dioxin-like compounds in compost.  相似文献   

16.
Leaching of volatile substances from resin-based dental materials may have a potential impact on the biocompatibility as well as safety of these materials. Information from manufacturers on ingredients in the materials is very often incomplete. Patients and dentists may be in contact with components emitted from cured dental fillings or from substrates applied in their preparation. Therefore, determination of the components of these materials is necessary for better prevention from possible harmful effects caused by dental fillings. The aim of this work was the isolation and identification of organic compounds evolved from four commercial resin-modified glass-ionomer cements (resin-based dental materials applied in dentistry) by using an alternative method of volatile compounds analysis-HS-SPME (headspace-solid phase microextraction). Dental materials were heated in closed vial at various temperatures and volatile substances released into the headspace phase above the sample were isolated on a thin polymeric fibre placed in SPME syringe. Identification was performed by using the GC-MS (gas chromatography-mass spectrometry) technique. Almost 50 RMGIC (resin-modified glass-ionomer cement) components (monomers and additives) were identified. The main identified leachables were: iodobenzene (DPICls-diphenyliodonium chloride degradation product), camphorquinone (photo-initiator), tert-butyl-p-hydroxyanisole (inhibitor), 4-(dimethylamino)ethyl benzoate (co-initiator), ethylene glycol dimethacrylate (monomer).  相似文献   

17.
The Pearl River Delta (PRD) is one of the largest fast-developing economic zones in China. Hong Kong and the mainland part of the PRD differed in socio-economic development history and chemical management policies. Polyurethane foam (PUF)-passive air sampling (PAS) was deployed at 21 regional air quality monitoring stations across the PRD in summer and winter, respectively. Dichloro-diphenyl-trichloroethane (DDT), chlordane and hexachlorobenzene (HCB) were analyzed with GC-MS. High total DDT (240-3700 pg m(-3)) and chlordane (100-2600 pg m(-3)) concentrations were observed. Concentrations of DDTs and chlordane were higher in summer than winter; HCB vice versa. Spatially, the mainland part of the PRD generally displayed higher DDT concentrations than Hong Kong. Antifouling paint for fishing ships in coastal China was suggested to be an important current DDT source in the coast. The reason is unknown for the very low trans-/cis-chlordane (TC/CC) ratios (0.27) found in the mainland in winter. HCB concentrations were relatively uniform across the PRD, and long range transport of HCB from inland/North China to the PRD in winter was suggested.  相似文献   

18.
Gas chromatography-mass spectrometry (GC-MS) using a quadrupole instrument and GC-tandem MS (GC-MS-MS) using an ion trap instrument were applied to determine 3-hydroxy fatty acids (3-OH FAs) with 10-18 carbon chain lengths, specific components of the endotoxin (lipopolysaccharide, LPS) of Gram-negative bacteria, in 30 house dust samples. The two methods provided similar detection sensitivity for methyl ester/trimethylsilyl derivatives of the 3-OH FAs and allowed these acids to be distinguished from co-eluting 2-OH FA derivatives. The correlation coefficients between endotoxin activity (Limulus test) and the combined amounts of 3-OH C10, 3-OH C12, and 3-OH C14 were 0.60 and 0.61 when using GC-MS and GC-MS-MS, respectively. The superior selectivity of GC-MS-MS was illustrated in analyses of sub-milligram amounts of dust, where the chromatograms achieved by GC-MS were difficult to interpret due to a high background and several closely eluting compounds. GC-MS-MS is therefore preferable to GC-MS for determining 3-OH FAs in minute (sub-milligram) amounts of dust.  相似文献   

19.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

20.
An ultrasonic bath and an ultrasonic probe have been used to develop rapid versions of the three-stage Community Bureau of Reference (BCR, now the Standards, Measurement and Testing Programme) sequential extraction procedure. The effect of the ultrasonic treatments on the extraction of copper, iron, manganese and zinc from a sewage sludge-amended soil has been assessed. Recoveries similar to those of conventional shaking (i.e., conventional value, +/- 30%) could generally be obtained for copper, manganese and zinc, but not for the important matrix element iron. With the use of compromise sonication conditions, steps 1, 2 and 3 of the sequential extraction (excluding the hydrogen peroxide digestion in step 3, which was not performed with sonication) could be completed in 3, 5 and 1 min, respectively, using the ultrasonic probe, and in 3, 1 and 1 h, respectively, using the bath. The extraction procedures developed using the soil performed well when applied to lake sediment BCR CRM 601. Analyte partitioning was generally similar to that obtained with mechanical shaking, and overall metal recoveries were 84-98% of those obtained with the conventional BCR protocol, except for copper extracted with the probe (74%). Poorer performance (analyte recoveries, 58-104%) was obtained when the methods were applied to an intertidal sediment. This highlights the difficulty of developing a version of the BCR extraction, with ultrasonic assistance, which gives a performance equivalent to conventional shaking when applied to different substrates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号