首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.  相似文献   

2.
配制气体样品是异味测试及相关研究的基础工作,配气稳定性直接影响测试结果准确度。三点比较式臭袋法使用微量进样针量取并转移液体标准物质到3L无臭气袋的传统配气方法。对于异味阈值较小物质或样品浓度处于较低范围时,为了降低取样体积波动对配气精度和稳定性的影响。提出先将标准注入100mL玻璃注射器,充分挥发混匀后再转移部分气体到无臭气袋的两步式配气方法。结果表明,2种配气方法的准确度不存在显著差异,但两步式配气法的配气稳定性明显优于传统方法。此外,研究还发现,常见异味物质在被注人气袋后3min内便能完全挥发并混合均匀。除一些挥发性和吸附性极强的物质外,气袋内的异味物质气体浓度能在配好后20min内基本保持不变。  相似文献   

3.
Certain odor control regulations specify use of the Scentometer for ambient odor measurement. This evaluation is usually performed by a single individual who is surrounded by the odorous environment to be measured. A method is desired where an ambient odor sample can be evaluated by an adequate size panel in an odor-free atmosphere. A dynamic forced-choice triangle olfactometer was designed and constructed to measure ambient odors. Teflon bags of 18 liter capacity collect a sample within 2-3 minutes which includes pre-flushing the bag. The sample is evaluated by a dynamic olfactometer equipped with 5 dilution levels (81×, 27×, 9×, 3× and undiluted sample). Three sniffing ports are provided at each dilution level to present dynamically one diluted odor stimulus and two odor-free air blanks. Each panelist is required to indicate which port contains the odor. Evaluation of one sample is routinely completed by a panel of 9 within less than 15 minutes. The odor threshold value (ED50) for the panel is calculated by use of a simple table derived statistically. No significant loss of odor was observed in sampling and in storage of rendering odors up to 48 hours. Bags were reusable after flushing with odor-free air. Reproducibility of log ED50 values by the same panel was within a σ = 0.10 log10. Agreement in evaluating duplicate field samples by two different panels was within the same limits. Under controlled laboratory conditions, a Scentometer reading of D/T = 2 was equivalent to an ED50 = 4.8; and D/T = 7 was equal to ED50 = 9.5.  相似文献   

4.
5.
针对实际运行过程中,袋式除尘器滤袋使用寿命短,压力损失过大的问题,本文以翼形上进风袋式除尘器为研究对象,采用CFD(computational fluid dynamics)技术模拟分析不同滤袋数(分别为92、88、84、80、76和72)时袋式除尘器内气流分布和压力损失规律。主要考察了流量分配系数、最大流量不均幅值、气流迹线、滤袋表面速度分布与压降等指标。结果表明,滤袋数为76个时,气流分布最为均匀,各滤袋负载均衡;相同过滤速度下,装置的压降随滤袋数目的增加而上升,即压降大小顺序为9288847672;与72个滤袋相比,76个滤袋的可用过滤面积更大。综合考虑,袋式除尘器的最优滤袋数目为76个。模拟结果为袋式除尘器的设计和优化提供了依据。  相似文献   

6.
Experiments were conducted to investigate the appearance of contaminants in fluorocarbon-film bags which have been widely used as photochemical reactors and storage containers in air pollution research. Clean air stored in such bags was gradually contaminated by a wide range of heavy hydrocarbons (≥ C5 ) as well as by nitrogen oxides. Warming a bag dramatically increased the contamination rate for hydrocarbons. The substances observed in the bags appear to have originated in the air outside the bags and appeared in the bags due to the permeability of the film. When a bag was stored in a controlled clean environment, the rate of contamination by hydrocarbons was dramatically reduced. Experiments in which high concentration mixtures of hydrocarbons and nitrogen oxides were stored in the bags likewise showed that some high molecular weight hydrocarbons as well as NO and NO2 permeate through the bag walls. Decontamination of the bags can be accomplished by storing them in a clean environment.  相似文献   

7.
Abstract

Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75–μm solid–phase microextraction fibers, polyvinyl fluo–ride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b–diphenylene–oxide polymer resin (Tenax TA) tubes, and standard 6–L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p–cresol, indole, 4–ethylphenol, and 2'–aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5– and 24–hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in–house–made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N–dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.  相似文献   

8.
Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75-microm solid-phase microextraction fibers, polyvinyl fluoride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b-diphenylene-oxide polymer resin (Tenax TA) tubes, and standard 6-L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p-cresol, indole, 4-ethylphenol, and 2'-aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5- and 24-hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in-house-made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N-dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.  相似文献   

9.
Vertical snow sampling and moss bag transplants were used to estimate the local inorganic and organic pollutant load deposited from traffic along a major highway in Finland. The pH and concentrations of Cl(-), NO(3)(-), SO(4)(2-), Ca(2+), Na(+) and polyaromatic hydrocarbons (PAHs) were determined from snow samples collected in winter at different sites along the highway. In summer, moss bags containing 20 g of fresh red-stemmed feather moss (Pleurozium schreberi) were transplanted at the same sites. The moss bag transplants remained exposed to roadside traffic for a period of one month following which the samples were collected and the PAH profiles and concentrations were analysed. The deposition of inorganic and organic pollutants from road traffic was observed up to 60 m from the road. The prevailing winds had a significant effect on the dispersion of pollutants. Snow appears to be a good collector of inorganic pollutants from the atmosphere and can be used to monitor local airborne pollution from road traffic. Snow packs can also be used as passive collectors of organic pollutant loads from road traffic on a local scale. To monitor organic PAH deposition from the road traffic, moss bags appeared to be better indicators compared to snow sampling. The efficiency of moss bags in accumulating PAH compounds indicate that vegetation may be an important sink for traffic pollution.  相似文献   

10.
Abstract

Loss of filtration efficiency in a fabric filter baghouse is typically caused by bag failure, in one form or another. The degree of such failure can be as minor as a pinhole leak or as major as a fully involved baghouse fire. In some cases, local air pollution regulations or federal hazardous waste laws may require estimation of the total quantity of particulate matter released to the environment as a result of such failures. In this paper, a technique is presented for computing the dust loading in the baghouse exhaust when one or more bags have failed. The algorithm developed is shown to be an improvement over a previously published result, which requires empirical knowledge of the variation in baghouse pressure differential with bag failures. An example calculation is presented for a bag-house equipped with 200 bags. The prediction shows that a small percentage of failed bags can cause a relatively large proportion of the gas flow to bypass the active bags, which, in turn, leads to high outlet dust loading and low overall collection efficiency from the baghouse.  相似文献   

11.
Methylene chloride (CH2Cl2) is presently under study by the U.S. EPA and other agencies to determine if the compound presents an unreasonable risk to human health and to determine if regulatory action is needed to reduce the risk. This paper describes one portion of the study which required the development and validation of a method of sampling and analysis for source emission measurements.

Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH2Cl2 remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emission sources of CH2Cl2 were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the U.S. EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH2Cl2. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision In both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed that interand intra-laboratory precision was within 10 percent.  相似文献   

12.
A method employing the timed fill of Mylar bags was used to obtain average carbon monoxide concentration values for ten locations in the Fairbanks, Alaska, area. The method is shown to be accurate, reliable, and inexpensive. The correlation coefficient between the bag sampling method and a continuous carbon monoxide analyzer was 0.945; correlation of carbon monoxide data from several locations to a reference in downtown Fairbanks showed a general decrease with distance from the reference analyzer. Analysis of data from Fairbanks shows that carbon monoxide concentrations during the winter months may have to be reduced 50-75% to achieve the State and National Ambient Air Quality Standards; the high levels of carbon monoxide are the result of emissions from automobile traffic during periods of severe inversion in the Fairbanks basin.  相似文献   

13.
From the hygienic point of view, not only the health hazards caused by air pollutants but also the odor from emitted flue gases should be reduced to a minimum. An effective control of the risk of odor at ground level presupposes knowledge of the source concentration of the odoriferous gas as well as its odor threshold. This threshold has to be estimated empirically, as the flue gases often contain a complex mixture of different odoriferous substances, the odor thresholds of which are in most cases unknown. For this purpose a method has been developed for estimating the odor thresholds of flue gases emitted, from different industrial processes. The method, afield method, is based on an exposure procedure, a number of subjects compare different concentrations of the flue gas with samples of fresh air and decide at what concentration the flue gas is no longer noticeable. The gas samples used are neither compressed, nor absorbed or heated before the exposure test. The method has been used in two studies on gases from Swedish sulfate cellulose plants. In order to estimate the effect on the odor threshold of different deodorizing measures, gas samples were taken not only from the stack but also from different phases in the production process. The results and a brief discussion on the practical applications of the method are given.  相似文献   

14.
Sampling and monitoring for cyanotoxins can be problematic as concentrations change with environmental and hydrological conditions. Current sampling practices (e.g. grab samples) provide data on cyanotoxins present only at one point in time and may miss areas or times of highest risk. Recent research has identified the widespread distribution of anatoxin-producing benthic cyanobacteria in rivers highlighting the need for development of effective sampling techniques. In this study we evaluated the potential of an in situ method known as solid phase adsorption toxin tracking (SPATT) for collecting and concentrating anatoxin-a (ATX) and homoanatoxin-a (HTX) in river water. Fifteen different adsorption substrates were screened for efficiency of ATX uptake, nine of which retained high proportions (>70%) of ATX. Four substrates were then selected for a 24-h trial in a SPATT bag format in the laboratory. The greatest decrease in ATX in the water was observed with powdered activated carbon (PAC) and Strata-X (a polymeric resin) SPATT bags. A 3-d field study in a river containing toxic benthic cyanobacterial mats was undertaken using PAC and Strata-X SPATT bags. ATX and HTX were detected in all SPATT bags. Surface grab samples were taken throughout the field study and ATX and HTX were only detected in one of the water samples, highlighting the limitations of this currently used method. Both Strata-X and PAC were found to be effective absorbent substrates. PAC has the advantage that it is cheap and readily available and appears to continue to sorb toxins over longer periods than Strata-X. SPATT has the potential to be integrated into current cyanobacterial monitoring programmes and would be a very useful and economical tool for early warning of ATX and HTX contamination in water.  相似文献   

15.
ABSTRACT

Intensity and threshold dilution ratio are two important indices for odor control of swine buildings. Although odor threshold dilution ratio is a widely used index to describe an odor, it should be related to intensity to be more useful. A method was proposed to measure both indices simultaneously by using a dynamic forced-choice olfacto-meter. Four air samples were taken from each of four swine rooms including farrowing, finisher, gestation, and nursery. A panel of eight people was used to evaluate odor intensity. Odor threshold dilution ratios were calculated according to the American Society for Testing and Materials (ASTM) Standard Practice E679-91 to be 333, 424, 25, and 221 for samples collected from farrowing, finisher, gestation, and nursery rooms, respectively. After the samples were diluted 14.7 times, the odor intensities were evaluated to be 3.79, 3.46, 0.48, and 4.0 for the above-mentioned rooms, respectively. The data collected were used to develop a mathematical model.  相似文献   

16.
Loss of filtration efficiency in a fabric filter baghouse is typically caused by bag failure, in one form or another. The degree of such failure can be as minor as a pinhole leak or as major as a fully involved baghouse fire. In some cases, local air pollution regulations or federal hazardous waste laws may require estimation of the total quantity of particulate matter released to the environment as a result of such failures. In this paper, a technique is presented for computing the dust loading in the baghouse exhaust when one or more bags have failed. The algorithm developed is shown to be an improvement over a previously published result, which requires empirical knowledge of the variation in baghouse pressure differential with bag failures. An example calculation is presented for a baghouse equipped with 200 bags. The prediction shows that a small percentage of failed bags can cause a relatively large proportion of the gas flow to bypass the active bags, which, in turn, leads to high outlet dust loading and low overall collection efficiency from the baghouse.  相似文献   

17.
Odor emissions during manure spreading events have become a source of concern, particularly where farms are located nearby urban areas. The objective of the present study was to compare odor concentrations and odor emission rates due to pig manure application using two different types of applicators, a sub-surface deposition system and a conventional splash-plate applicator. Air samples were collected using a Surface Isolation Flux Chamber and the "bag-in-vacuum chamber" techniques, at 0.5, 1.5 and 2.5 hours after manure application. A three-station forced-choice dynamic dilution olfactometer was used by an odor panel for determining odor concentration. Preliminary results indicated that with the sub-surface deposition system applicator odor emission rate was reduced by 8% to 38% compared to that of the conventional splash-plate applicator. The highest reduction in odor strength and odor emission rate was observed in the most offensive period after manure application. The sub-surface deposition system may be a solution for hog producers who wish to reduce odor complaints from applying manure without the cost and problems associated with deep injection systems.  相似文献   

18.
One of the most important considerations in baghouse operation is the effect of bag failure on outlet loading. This information would be Of use to equipment manufacturers, users, and regulatory officials. Unfortunately, little information is available in the literature on this aspect of baghouse performance. Equations describing changes in outlet loading resulting from the sudden rupture of one or more bags are developed from first principles. Calculated results from these equations are presented in the form of a chart which can very quickly and simply be used to obtain a numerical value for a revised outlet loading resulting from bag failure(s) for a variety of system conditions. Due to an assumption made in the derivation, the new outlet loading thus obtained represents the maximum increase (worst case conditions) to be expected from the rupture of one or more bags. The following variables are included in the analysis: inlet loading, outlet loading (prior to bag failure), number of bag failures, bag diameter, system pressure drop; and gas temperature.  相似文献   

19.
Intensity and threshold dilution ratio are two important indices for odor control of swine buildings. Although odor threshold dilution ratio is a widely used index to describe an odor, it should be related to intensity to be more useful. A method was proposed to measure both indices simultaneously by using a dynamic forced-choice olfactometer. Four air samples were taken from each of four swine rooms including farrowing, finisher, gestation, and nursery. A panel of eight people was used to evaluate odor intensity. Odor threshold dilution ratios were calculated according to the American Society for Testing and Materials (ASTM) Standard Practice E679-91 to be 333, 424, 25, and 221 for samples collected from farrowing, finisher, gestation, and nursery rooms, respectively. After the samples were diluted 14.7 times, the odor intensities were evaluated to be 3.79, 3.46, 0.48, and 4.0 for the above-mentioned rooms, respectively. The data collected were used to develop a mathematical model.  相似文献   

20.
The basic principle of odor sampling from surface sources is based primarily on the amount of air obtained from a specific area of the ground, which acts as a source of malodorous compounds. Wind tunnels and flux chambers are often the only available, direct method of evaluating the odor fluxes from small area sources. There are currently no widely accepted chamber-based methods; thus, there is still a need for standardization of these methods to ensure accuracy and comparability. Previous research has established that there is a significant difference between the odor concentration values obtained using the Lindvall chamber and those obtained by a dynamic flow chamber. Thus, the present study compares sampling methods using a streaming chamber modeled on the Lindvall cover (using different wind speeds), a static chamber, and a direct sampling method without any screens. The volumes of chambers in the current work were similar, ~0.08 m3. This study was conducted at the mechanical-biological treatment plant in Poland. Samples were taken from a pile covered by the membrane. Measured odor concentration values were between 2 and 150 ouE/m3. Results of the study demonstrated that both chambers can be used interchangeably in the following conditions: odor concentration is below 60 ouE/m3, wind speed inside the Lindvall chamber is below 0.2 m/sec, and a flow value is below 0.011 m3/sec. Increasing the wind speed above the aforementioned value results in significant differences in the results obtained between those methods. In all experiments, the results of the concentration of odor in the samples using the static chamber were consistently higher than those from the samples measured in the Lindvall chamber. Lastly, the results of experiments were employed to determine a model function of the relationship between wind speed and odor concentration values.

Implications: Several researchers wrote that there are no widely accepted chamber-based methods. Also, there is still a need for standardization to ensure full comparability of these methods. The present study compared the existing methods to improve the standardization of area source sampling. The practical usefulness of the results was proving that both examined chambers can be used interchangeably. Statistically similar results were achieved while odor concentration was below 60 ouE/m3 and wind speed inside the Lindvall chamber was below 0.2 m/sec. Increasing wind speed over these values results in differences between these methods. A model function of relationship between wind speed and odor concentration value was determined.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号