首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Studies on health effects of air pollutants ideally define exposure through the collection of air samples in the participants' homes. Concentrations derived from these samples are then considered as an estimate for the average concentration of air pollutants in the homes. Conclusions drawn from such studies therefore depend very much on the validity of the measured air pollution concentrations. In this paper we analysed repeated BTEX and NO(2) measurements with a time period of several months lying between the two conducted home visits. We investigated the variability of their concentrations over time by determining correlation coefficients and calculating within- and between-home variances. Our population consisted of 631 homes of participants from two cohort studies within the framework of the German study on Indoor Factors and Genetics in Asthma. Air pollutants were measured using passive samplers both indoors and outdoors. The measured BTEX concentrations were poorly correlated, with Pearson's correlation coefficient r ranging from -0.19 to 0.27. Additionally, a considerable seasonal effect could be observed. A higher correlation was found for the NO(2) concentrations with r ranging between 0.24 and 0.55. For the BTEX, the between-home variance was bigger than the within-home variance, for NO(2) both variances were of about the same order. Our results indicate that in a setting of moderate climate like in Germany, the variability of BTEX and NO(2) concentrations over time is high and a single measurement is a poor surrogate for the long-term concentrations of these air pollutants.  相似文献   

2.
Three-dimensional turbulent flow and dispersion of gaseous pollutants carbon monoxide (CO) and nitrogen oxides (NOx) in a road tunnel was modeled using the standard kε turbulence model and solved numerically using the finite volume method. Vehicle emissions were estimated from the measured traffic flow rates and modeled as banded line sources along the tunnel floor. The effects of fan ventilation and piston effect of moving vehicles on the airflow and pollutant dilution were examined. The numerical results reveal that a peak velocity exists near the tunnel floor due to the piston effect of vehicles. The cross-sectional concentrations of air pollutants are non-uniformly distributed and concentrations rise with downstream distance. The piston effect of vehicles can alone provide 25%–34% dilution of air pollutants in the tunnel, compounded 43%–70% dilution effect according to the ventilation condition.  相似文献   

3.
In order to characterize the status of indoor air pollution in some important facilities, a list of key criteria pollutants [particulate matter (PM(10)), carbon dioxide (CO(2)), carbon monoxide (CO), formaldehyde (HCHO), and bioaerosol] was measured from a total of 91 randomly selected sites in 18 different cities, Korea (February 2006 to December 2009). The target facilities include 43 child care facilities, 38 medical facilities, 6 elementary schools, and 4 postnatal care centers. The results showed that some air pollutants (e.g., CO and HCHO) did not exceed the recommended guideline [e.g., the Korean indoor air standard (KIAS) values of 10 ppm and 100 ppb, respectively]. However, concentration of PM(10), CO(2), and bioaerosol occasionally exceeded their respective guidelines (e.g., seven, three, and two cases). Discrete seasonalities were observed from indoor pollutants because of varying ventilation practice (e.g., summer time dominance of PM(10), HCHO, and bioaerosol or winter dominance of CO(2) and CO). However, as the concentrations of the indoor pollutants were scarcely above the recommended guideline level, more diversified approaches are desirable to diagnose the status of indoor pollution and to provide a realistic strategy for the improvement of IAQ.  相似文献   

4.
Aerosol, NO and CO concentration, temperature, air humidity, air flow and number of running ventilation fans were measured by continuous analysers every minute for a whole week for six different one-week periods spread over ten months in 2001 and 2002 at measuring stations in the 7860 m long tunnel. The ventilation control system was mainly based on aerosol measurements taken by optical scatter sensors. The ventilation turned out to be satisfactory according to Norwegian air quality standards for road tunnels; however, there was some uncertainty concerning the NO2 levels. The air humidity and temperature inside the tunnel were highly influenced by the outside metrological conditions. Statistical models for NO concentration were developed and tested; correlations between predicted and measured NO were 0.81 for a partial least squares regression (PLS1) model based on CO and aerosol, and 0.77 for a linear regression model based only on aerosol. Hence, the ventilation control system should not solely be based on aerosol measurements. Since NO2 is the hazardous polluter, modelling NO2 concentration rather than NO should be preferred in any further optimising of the ventilation control.  相似文献   

5.
Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people working in the mall, should be of health effect concern.  相似文献   

6.
Flow Field and Pollution Dispersion in a Central London Street   总被引:3,自引:0,他引:3  
Urban pollution due to roadways is perceived as a major obstacle to implementing low-energy ventilation design strategies in urban non-domestic buildings. As part of a project to evaluate the use of a computational fluid flow model as an environmental design tool for urban buildings, this paper seeks to address the impact of pollution from roadways on buildings in areas of restricted topography and assess dominant influencing factors and other requirements for testing the flow model predictions. Vertical profiles of carbon monoxide (CO) and temperature at the facade of a building in a Central London street, in addition to above-roof wind speed and direction, were measured over a period of three months. The street has a height-to-width (h/W) ratio of 0.6 and is of asymmetric horizontal alignment. The air flows in the area surrounding the building were modelled using a computational fluid flow model for two orthogonal wind directions. CO concentrations were calculated from the steady-state flow field in order to place point measurements in the context of the flow field, identify persistent features in the measured data attributable to the flow structure and, by comparison with measurements, identify further testing requirements.Some qualitative and quantitative agreement between measured and modelled data was obtained. Measured CO levels at the building facade and vertical variations of CO were small, as predicted by the model. A wake-interference type flow was predicted by the model for wind speeds >2ms-1 with formation of a vortex cell occurring for roof-level wind speeds >5ms-1 for the cross-wind direction, which was reflected in the measured CO levels and facade gradients. A direction-dependent inverse relationship was noted, both in the model and measurements, between above-roof wind speed and facade CO levels although statistical correlations in the time series were poor. CO concentrations at the facade were found to increase with height frequently, as well as decrease, especially for parallel winds. It is expected that mechanical turbulence due to vehicles was largely responsible. In comparison, thermal stratification appeared to play only a minor role in controlling vertical mixing in the street, under low wind speed conditions.  相似文献   

7.
Carbon monoxide concentrations were measured at ground level (1 m) near heavy traffic streets in downtown Santiago de Chile in periods of low (November and December), intermediate (April) and high (May) ambient concentrations. Also, measurements were carried out at several heights (from 1 to 127 m) in Santiago’s main street during winter time. Measurements carried out at ground level show maximum values during the morning rush hour, with values considerably higher than those reported by the urban air quality network, particularly in summer time. However, the measured values are below air quality standards. Vertical CO profiles were measured in a tower located in the center of downtown. Below 40 m (average altitude of neighboring buildings), the profiles do not show a consistent vertical gradient, with CO concentrations increasing or decreasing with height, regardless of atmospheric stability. In this low altitude range, the observed vertical profiles are poorly predicted by a street canyon model, and the measured concentrations can not be described by a simple exponential decay. At higher altitudes (40 and 127 m) a negative gradient in CO concentrations is observed, both for stable and unstable atmospheric conditions. The values of CO measured at 127 m are relatively well described by an Eulerian dispersion model running with current CO emission inventories for Santiago, although this model tends to predict stepper CO gradients than the observed ones.  相似文献   

8.
In present study horizontal and vertical distribution of traffic-related pollutants (CO and SO(2)) within the street canyons in (CO and SO(2)) Varanasi, India was monitored. The results showed that average horizontal profiles of traffic-related pollutant concentrations within street canyon at leeward side were approximately same as that of windward side. However, the vertical concentration of both the pollutants decreases with height above the ground and study indicated that CO and SO(2) concentrations at different heights below the roof showed clear vertical self-gradient. CO and SO(2) concentration decreased with height and the minimum value occurred at the roof. It was concluded from the observed results that pollutants from vehicular exhaust emissions in the street canyon of Varanasi were evenly distributed. This result may be due to the fact that wind vortices are not formed. Therefore, urban planners can use this type of streets so that there is proper ventilation and dispersal of pollutants.  相似文献   

9.
An assessment of air quality in the vicinity of a selected school has been carried out by monitoring the concentrations of primary pollutants. The results has shown that during the school hours, the measured pollutants emitted from the cars next to the selected school, such as CO and NO(2), are always under the allowable limits for Kuwaiti air quality standards. On the other hand, the concentrations of non methane hydrocarbon pollutant (nm-HC), some of which are considered to be cancergenic, are found to be above the Kuwaiti standard most of the times. A traffic counter is used to record the number of cars in the main road next to the school in 15 min intervals for 10 days during the monitoring period for air quality. Statistical analysis is performed to develop a relation for prediction of the necessary reduction in traffic, based on CO concentrations, during morning and afternoon periods on working days. A computer dispersion model (CALINE4) is also used to assess the CO concentrations based on recorded flow of traffic and emission inventory with the prevailing meteorological conditions existed at the specified time. After the validation of model, different scenarios have been evaluated to provide an acceptable solution to resolve the traffic congestion problem near the schools in the early morning hours with substantial reduction in pollution levels. The optimal solution for CO concentration reduction by managing smooth traffic flow is to reduce the traffic intensity by half in early morning and afternoon rush hours. The results of the predicted CO concentration in the vicinity of the school for the model and the statistical analysis has shown reduction of 30% and 42% respectively, for approximately 50% decrease in the car use. On the other hand the predicted CO concentration for the model and the statistics reached 24% and 33% respectively when 50% of students opted for buses instead of using private cars.  相似文献   

10.
Indoor and ambient concentrations of 21 volatile organic compounds (including 14 hazardous air pollutants) were measured in the homes of nearly 80 western Montana (Missoula) high school students as part of the 'Air Toxics Under the Big Sky' program during the 2004/2005 and 2005/2006 school years. Target analytes were measured using low flow air sampling pumps and sorbent tubes, with analysis of the exposed samples by thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS). The results reported here present the findings of the first indoor/ambient air toxics monitoring program conducted in a semi-rural valley location located in the Northern Rocky Mountain/Western Montana region. Of all of the air toxics quantified in this study, toluene was found to be the most abundant compound in both the indoor and ambient environments during each of the two school years. Indoor log-transformed mean concentrations were found to be higher when compared with ambient log-transformed mean concentrations at P < 0.001 for the majority of the compounds, supporting the results of previous studies conducted in urban areas. For the air toxics consistently measured throughout this program, concentrations were approximately six times higher inside the student's homes compared to those simultaneously measured directly outside their homes. For the majority of the compounds, there were no significant correlations between indoor and ambient concentrations.  相似文献   

11.
利用AQI和PM_(2. 5)质量浓度、地面气象要素、NCEP、ERSST_V3、GBL等资料,对2016年12月29日至2017年1月5日洞庭湖区一次重度空气污染过程成因进行了分析。结果表明,静稳天气形势下的累积效应和本地持续升温、降压、增湿、小风导致污染物浓度不断增加。本地风速与雨量对污染物浓度产生显著影响。降温前风速明显加大,有利于污染物快速扩散。湿度增加有利于污染物吸湿性增长,但高湿易引起降水有利于污染物的湿清除。此次重度空气污染过程中大气稳定度为中性或稳定,14:00混合层高度逐渐降低且重度空气污染日降至100 m以下。污染物空间分布与主导风向和污染通道密切相关。气流后向轨迹分析表明,洞庭湖区各地气流来源和影响路径差异明显,且存在大范围区域性同步污染现象。北方外来污染源是洞庭湖区重要的污染面源,本地工业污染排放点源和地理条件也是洞庭湖区空气污染物空间分布差异的重要因素。  相似文献   

12.
CO concentrations were measured in five kindergartens, one children's hospital and two homes for aged, practically without indoor sources, all situated in the city centre, for ten random days in winter and ten in summer. The indoor CO concentrations were the result of the distance from and the traffic density in the nearest street, of general pollution level, seasonal differences, day-to-day variations and daily cycle of air pollution, the vicinity of traffic having a dominant influence. Therefore location of institutions for sensitive population groups in old city centres within a block of houses seems to be a suitable solution as far as exposure to CO is concerned.Revised version of a paper presented as poster at the VIth World Congress on Air Quality, Paris 1983.  相似文献   

13.
Our group previously demonstrated that carbon dioxide (CO2) levels in heavily occupied schools correlate with the levels of airborne bacterial markers. Since CO2 is derived from the room occupants, it was hypothesized that in schools, bacterial markers may be primarily increased in indoor air because of the presence of children; directly from skin microflora or indirectly, by stirring up dust from carpets and other sources. The purpose of this project was to test the hypothesis. Muramic acid (Mur) is found in almost all bacteria whereas 3-hydroxy fatty acids (3-OH FAs) are found only in Gram-negative bacteria. Thus Mur and 3-OH FA serve as markers to assess bacterial levels in indoor air (pmol m(-3)). In our previous school studies, airborne dust was collected only from occupied rooms. However, in the present study, additional dust samples were collected from the same rooms each weekend when unoccupied. Samples were also collected from outside air. The levels of dust, Mur and C10:0, C12:0, C14:0, and C16:0 3-OH FAs were each much higher (range 5-50 fold) in occupied rooms than in unoccupied school rooms. Levels in outdoor air were much lower than that of indoor air from occupied classrooms and higher than the levels in the same rooms when unoccupied. The mean CO2 concentrations were around 420 parts per million (ppm) in unoccupied rooms and outside air; and they ranged from 1017 to 1736 ppm in occupied rooms, regularly exceeding 800-1000 ppm, which are the maximum levels indicative of adequate indoor ventilation. This indicates that the children were responsible for the increased levels of bacterial markers. However, the concentration of Mur in dust was also 6 fold higher in occupied rooms (115.5 versus 18.2 pmole mg(-1)). This further suggests that airborne dust present in occupied and unoccupied rooms is quite distinct. In conclusion in unoccupied rooms, the dust was of environmental origin but the children were the primary source in occupied rooms.  相似文献   

14.
Air samples were collected from 4 field sites in Europe: 2 sites from the UK, Hazelrigg (semi-rural) and Manchester (urban); 1 site from Ireland: Mace Head (rural); and 1 site from Norway: Kjeller (rural). Additionally, air samples were taken from indoor locations in Troms?, Norway. Air samples were collected using high-volume air samplers employing sampling modules containing glass-fibre filters (GFFs, particle phase), and glass columns with a polyurethane foam (PUF)-XAD-2-PUF sandwich (gaseous phase). Typical outdoor air volumes required for the determination of per- and polyfluorinated alkyl substances (PFAS) ranged from 500-1800 m3. GFFs and PUF-XAD columns were analysed separately to obtain information on phase partitioning. All air samples were analysed for volatile, neutral PFAS, with selected GFF samples halved for analysis of both neutral and airborne particle-bound ionic PFAS. Volatile PFAS were extracted from air samples by cold-column immersion with ethyl acetate, and were analysed by gas chromatography-mass spectrometry in the positive chemical ionisation mode (GC-PCI-MS). Ionic PFAS were extracted from GFFs by sonication in methanol, and were analysed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) using electrospray ionisation in the negative ion mode (ESI-). Perfluorooctanoate (PFOA) was often the predominant analyte found in the particulate phase at concentrations ranging from 1-818 pg m(-3), and 8:2 fluorotelomer alcohol (FTOH) and 6:2 FTOH were the prevailing analytes found in the gas phase, at 5-243 pg m(-3) and 5-189 pg m(-3), respectively. These three PFAS were ubiquitous in air samples. Many other PFAS, both neutral and ionic, were also present, and levels of individual analytes were in the 1-125 pg m(-3) range. Levels of some PFAS exceeded those of traditional persistent organic pollutants (POPs). In this study, the presence of 12:2 FTOH and fluorotelomer olefins (FTolefins), and ionic PFAS other than perfluorooctane sulfonate (PFOS) and PFOA, are reported in air samples for the first time. Concentrations of neutral PFAS were several orders of magnitude higher in indoor air than outdoor air, making homes a likely important diffuse source of PFAS to the atmosphere. Our repeated findings of non-volatile ionic PFAS in air samples raises the possibility that they might directly undergo significant atmospheric transport on particles away from source regions, and more atmospheric measurements of ionic PFAS are strongly recommended.  相似文献   

15.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

16.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

17.
Spatiotemporal characteristics and impact of ambient air-quality attributed to open burning of rice straw were analyzed and estimated with measured data. Two multivariate analytic methods, factor analysis and cluster analysis, were adopted to analyze the temporal and spatial impact on ambient air-quality during the rice straw burning episode. Temporal features of three scenarios were cited to compare the concentrations for ambient air-quality between the rice straw burning episode and non-episodes over two typical stations by factor analysis. Factor analysis demonstrated that the first rotational component, identified as being highly correlated to the open burning of rice straw, accounts for about 40% of the concentration variance for ambient air-quality. In typical air-quality stations, the average hourly incremental concentrations between the episode and non-episodes were greater than 300 μg m(-3) for PM(10), 1.0 ppm for CO and 35 ppb for NO(2) during the impact of rice straw burning. Factor analysis presented that the first rotated component was highly correlated with several primary pollutants (NO(2), NMHC, PM(10) and CO) during the rice straw burning episode, while every component was only highly correlated with a unique air pollutant during non-episodes. The delineation isopleths indicated that factor analysis could serve as a better method than cluster analysis and provides cross-county cooperation for local governments located in the same separated district during the rice straw burning season. The results of factor analysis revealed that CO is the best index to demonstrate the impact of rice straw burning than the other six air pollutants measured during the episode. Backward trajectory analysis supplied a cause-effect relationship between measured stations and specific rice planted regions during the rice straw burning episode.  相似文献   

18.
Methods for estimating airborne contaminant concentrations at specific locations within enclosed spaces, such as mathematical models and computational fluid dynamics (CFD), often are validated against directly measured concentrations. However, concentration variation with time introduces uncertainty into the measured concentration. Failure to determine monitoring time requirements can lead to errors in quantifying representative concentrations, which are likely to be attributed to errors in the method being validated. In the current study, to obtain the representative concentrations at multiple locations with a direct reading instrument, we used the standard deviation ratio (SDR) method to determine the required minimum monitoring time within a specified precision limit. To demonstrate the use of the SDR approach in constructing precision confidence intervals, tracer gas concentrations at nine sampling locations in an experimental room were measured to obtain population parameters. Three flow rates of 0.9, 3.3 and 5.5 m(3) min(-1) were employed and contaminant concentrations were measured using a photoionization analyser. Monitoring time requirements varied substantially with location within the room and were strongly dependent upon the flow rate of air through the room. The proposed method would be very useful for industrial hygienists and indoor air researchers who sometimes need to obtain several hundred measured concentrations for validation purposes or to perform tests under repeatable conditions in enclosed spaces. This study also showed that the proposed method can be used to devise efficient indoor monitoring strategies.  相似文献   

19.
Many large neighbourhoods are located near heavy-traffic roads; therefore, it is necessary to control the levels of air pollution near road exposure. The primary air pollutants emitted by motor vehicles are CO, NO2 and PM. Various investigations identify key health outcomes to be consistently associated with NO2 and CO. The objective of this study was the measurement-based assessment for determining whether by high-traffic roads, such as motorways and express ways, and the concentrations of CO and NO2 are within normal limits and do not pose threat to the local population. Average daily values (arithmetic values calculated for 1-h values within 24 h or less, depending on result availability) were measured for concentrations of NO2 and CO by automatic stations belonging to the Voivodship Environmental Protection Inspectorate in Katowice, in areas with similar dominant source of pollutant emission. The measurements were made in three sites: near the motorway and expressway, where the average daily traffic intensity is 100983 and 35414 of vehicles relatively. No evidence was found of exceeding average daily values equal to the maximum allowable NO2 concentration due to the protection of human health in the measurement area of the stations. No daily average values exceeding the admissible CO concentration (8-h moving average) were noted in the examined period. The results clearly show lack of hazards for general population health in terms of increased concentrations of CO and NO2 compounds that are closely related to high intensity car traffic found on selected motorways and speedways located near the city centres.  相似文献   

20.
Atmospheric BTEX [benzene, toluene, ethylbenzene, o-xylene and (m + p)-xylene] concentrations have been determined in the Naples metropolitan area (NMA) and in two suburban areas located on the north within about 25 km, during 2006. The pollutants were collected by passive samplers (24-h samplings), and analysed by GC-MS. In all the areas analysed the average atmospheric benzene concentrations were higher than the limit value fixed by the European Union for 2010 and in NMA the average concentration (9.8 microg m(-3)) also exceeded the limit fixed for 2006. High linear correlation coefficients between the average daily concentrations of the different BTEX are indicative of a single major source, most likely the vehicular traffic. The temporal and spatial distribution of BTEX relative concentrations suggest that massive emissions in NMA negatively affect the quality of the air in northern suburban areas, prevalently during the hottest months of the year, probably due to transport by local seasonal winds. The ratios between BTEX daily concentrations showed a clear dependence on the intensity of solar actinic flow, indicating a major role of photochemical processes in the air cleaning from these volatile organic pollutants.  相似文献   