首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 256 毫秒
1.
Font R  Esperanza M  García AN 《Chemosphere》2003,52(6):1047-1058
Lignin samples, sub-product in the Kraft process of cellulose from eucalyptus wood, were burnt in a laboratory scale furnace at different residence temperatures and with distinct fuel-rich atmospheres. The yields of CO, CO(2), eight light hydrocarbons (methane, ethylene, ethane, propylene, acetylene, butane, etc.) and 60 semi-volatile+volatile compounds (benzene, toluene, ethylbenzene, styrene, indene, naphthalene, dibenzofuran, phenanthrene, chrysene, etc.) were determined, with nominal reactor temperatures between 800 and 1100 degrees C and residence times of the volatiles evolved and formed between 4 and 7 s. The collection of the gases and volatiles evolved was carried out with a Tedlar bag and by XAD-4 resin respectively, comparing the data obtained in both cases. The emission factor (mg/kg) of the CO was between 2500 and 90000, and under the poor-oxygen atmosphere, the emission factors of many by-toxic products were greater than 100 mg/kg. A pyrolysis run was also performed, obtaining emission factors between 30 and 3000 mg/kg, facilitating its identification. The behaviour of different compounds in the combustion runs was discussed considering three groups in accordance with their stability vs. oxygen, and two groups vs. temperature.  相似文献   

2.
Font R  Aracil I  Fullana A  Conesa JA 《Chemosphere》2004,57(7):615-627
The evolution of semivolatile and volatile compounds in the combustion of polyethylene (PE) was studied at different operating conditions in a horizontal quartz reactor. Four combustion runs at 500 and 850 degrees C with two different sample mass/air flow ratios and two pyrolytic runs at the same temperatures were carried out. Thermal behavior of different compounds was analyzed and the data obtained were compared with those of literature. It was observed that alpha,omega-olefins, alpha-olefins and n-paraffins were formed from the pyrolytic decomposition at low temperatures. On the other hand, oxygenated compounds such as aldehydes were also formed in the presence of oxygen. High yields were obtained of carbon oxides and light hydrocarbons, too. At high temperatures, the formation of polycyclic aromatic hydrocarbons (PAHs) took place. These compounds are harmful and their presence in the combustion processes is related with the evolution of pyrolytic puffs inside the combustion chamber with a poor mixture of semivolatile compounds evolved with oxygen. Altogether, the yields of more than 200 compounds were determined. The collection of the semivolatile compounds was carried out with XAD-2 adsorbent and were analyzed by GC-MS, whereas volatile compounds and gases were collected in a Tedlar bag and analyzed by GC with thermal conductivity and flame ionization detectors.  相似文献   

3.
Methylene chloride (CH2Cl2) is presently under study by the U.S. EPA and other agencies to determine if the compound presents an unreasonable risk to human health and to determine if regulatory action is needed to reduce the risk. This paper describes one portion of the study which required the development and validation of a method of sampling and analysis for source emission measurements.

Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH2Cl2 remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emission sources of CH2Cl2 were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the U.S. EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH2Cl2. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision In both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed that interand intra-laboratory precision was within 10 percent.  相似文献   

4.
Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75-microm solid-phase microextraction fibers, polyvinyl fluoride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b-diphenylene-oxide polymer resin (Tenax TA) tubes, and standard 6-L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p-cresol, indole, 4-ethylphenol, and 2'-aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5- and 24-hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in-house-made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N-dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.  相似文献   

5.
Experiments were conducted to investigate the appearance of contaminants in fluorocarbon-film bags which have been widely used as photochemical reactors and storage containers in air pollution research. Clean air stored in such bags was gradually contaminated by a wide range of heavy hydrocarbons (≥ C5 ) as well as by nitrogen oxides. Warming a bag dramatically increased the contamination rate for hydrocarbons. The substances observed in the bags appear to have originated in the air outside the bags and appeared in the bags due to the permeability of the film. When a bag was stored in a controlled clean environment, the rate of contamination by hydrocarbons was dramatically reduced. Experiments in which high concentration mixtures of hydrocarbons and nitrogen oxides were stored in the bags likewise showed that some high molecular weight hydrocarbons as well as NO and NO2 permeate through the bag walls. Decontamination of the bags can be accomplished by storing them in a clean environment.  相似文献   

6.
Abstract

Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75–μm solid–phase microextraction fibers, polyvinyl fluo–ride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b–diphenylene–oxide polymer resin (Tenax TA) tubes, and standard 6–L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p–cresol, indole, 4–ethylphenol, and 2'–aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5– and 24–hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in–house–made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N–dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.  相似文献   

7.
通过在不同的时间段,测定存放于铝箔复合膜集气袋和玻璃注射器的丙酮,醋酸乙酯,苯,异丙醇标准气的浓度,气体浓度与贮存时间的关系,本次试验结果表明,丙酮,醋酸乙酯,苯,异丙醇在铝箔气袋中的稳定性明显优于在玻璃注射器中,应尽可能在8-24h内测定。  相似文献   

8.
Odor emission from livestock production systems is a major nuisance in many rural areas. This study aimed at determining the major airborne chemical compounds responsible for the unpleasant odor perceived in swine facilities during slurry handling, and at proposing predictive models of odor concentration (OC) based on the concentrations of specific odorants in the air. A multivariate data analysis strategy involving principal components analysis and multiple linear regressions was implemented to analyze the relationships between concentration of 35 gases (measured by GC/MS or gas detection tubes), and the overall OC perceived by sensory analysis. The study compiled data on the concentration of odor and odorants, measured in the headspace of 24 unstored and stored slurry samples collected from three different types of production units on 8 commercial swine farms. Among all the measured constituents, OC was found to have the highest correlation with the sulfur containing compounds (i.e. hydrogen sulfide, dimethylsulfide, dimethyldisulfide, dimethyltrisulfide). The concentration of hydrogen sulfide accounted for 68% of the variation in OC above the stirred slurry samples. The highest concentrations of volatile organic compounds were observed for phenols and indoles, which made a significant contribution to the overall OC when the slurry was fresh. The contribution of ammonia to the OC was only significant in the absence of hydrogen sulfide. The precision of predictive models of OC based on the concentration of specific odorants in the air was satisfactory (R2 between 0.66 and 0.89). Hence, this study suggests that monitoring of specific odor compounds released from agitated swine slurry can be used to predict the concentration of odor perceived close to the source (e.g. at storage units), allowing the assessment of odor nuisance potentials.  相似文献   

9.
With the rapid urbanization, the southeast coastal cities of China are facing increasing air pollution in the past decades. Large emissions of VOCs from vehicles and petrochemical factories have contributed greatly to the local air quality deterioration. Investigating the pollution characteristics of VOCs is of great significance to the environmental risk assessment and air quality improvement. Ambient VOC samples were collected simultaneously from nine coastal cities of southeast China using the Tedlar bags, and were subsequently preprocessed and analyzed using a cryogenic preconcentrator and a gas chromatography–mass spectrometry system, respectively. VOC compositions, spatial distributions, seasonal variations and ozone formation potentials (OPFs) were discussed. Results showed that methylene chloride, toluene, isopropyl alcohol and n-hexane were most abundant species, and oxygenated compounds, aromatics and halogenated hydrocarbons were most abundant chemical classes (62.5–95.6 % of TVOCs). Both industrial and vehicular exhausts might contribute greatly to the VOC emissions. The VOC levels in the southeast coastal cities of China were sufficiently high (e.g., 6.5 μg?m?3 for benzene) to pose a health risk to local people. A more serious pollution state was found in the southern cities of the study region, while higher VOC levels were usually observed in winter. The B/T ratio (0.26?±?0.09) was lower than the typical ratio (ca. 0.6) for roadside samples, while the B/E (1.6–7.6) and T/E (7.2–26.8) ratios were higher than other cities around the world, which indicated a unique emission profile in the study region. Besides, analysis on ozone formation potentials (OFPs) indicated that toluene was the most important species in ozone production with the accountabilities for total OFPs of 22.6 to 59.6 %.  相似文献   

10.
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.  相似文献   

11.
This paper presents results of an experimental study into factors contributing to decay of odor samples during storage, between 4 and 40 hr after sample collection. The odor studied was sampled from a tobacco processing plant as part of collaborative research with a view to establishing a manual outlining methods for odor annoyance management, specifically for the tobacco industry. In August and September 1997, an experimental program was carried out in which two types of tobacco odor were sampled: Burley Toaster and Mix. The dependent variable was odor concentration in the bag, measured by dynamic olfactometry in accordance with the draft Comité Européen de Normalisation (CEN) standard EN13725 "Air Quality-Determination of Odor Concentration by Dynamic Olfactometry." The independent variables were sampling bag material, degree of dilution during sampling, dilution gas used, particle removal during sampling, and age of sample in hours. In the first phase, 94 odor analyses were carried out. In a second test, 32 samples were analyzed for odor concentration. In addition, 16 samples were analyzed using gas chromatography-mass spectrometry (GC-MS). Analysis of the results (analysis of variance) led to the unexpected conclusion that Nalophan film bags performed significantly better than metalized Cali-Bond layered film as a bag material. The odor concentration of samples in Nalophan bags remained relatively stable between 4 and 12 hr after sampling. After 30 hr, decay to about half the initial concentration, as measured at 4 hr, was observed. Particle removal during sampling caused the odor concentration in the bags to be reduced by approximately 20%. For practical reasons, particle removal remains useful, to avoid contamination of equipment. Using air or nitrogen as the neutral gas for pre-dilution during sampling or the dilution factor used (between factor 2 and 6) did not appear to have an effect on the decay characteristic of odor samples. The following recommendations are suggested for the practice of collecting odor samples and apply specifically to tobacco processing emissions: Analyze samples as soon as possible, preferably within 12 hr; When samples age for more than 12 hr, decay is likely to cause a reduction in odor concentration to half the original concentration at age 30 hr; Use sampling bags made of Nalophan NA or benchmark performance of other materials against Nalophan NA before using alternative materials; Use pre-dilution when sampling only for the purpose of avoiding condensation during sample storage. Use an appropriate minimum dilution factor to avoid condensation; Both nitrogen and high-purity (synthetic) air are suitable to use as neutral gas for pre-dilution; and When sampling tobacco odors, use an odorless filter to remove particles. This practice removes a source of variation and avoids contamination of equipment. The effect on results, despite being consistently lower in odor concentration, is not meaningful in terms of perceived intensity or annoyance potential.  相似文献   

12.
Photocatalytic oxidation (PCO) of volatile organic compounds (VOCs) is a highly attractive alternative technology for purification and deodorization of indoor air. The main objectives of this study were to demonstrate that a common fluorescent visible light (FVL) lamp can be used to effectively remove by PCO low concentrations of VOCs from slightly contaminated air and to provide some fundamental and technical details on the process. The target VOC was n-butanol, which is a standard reference odorant. Its PCO was studied under a long residence time in a 3.7-L cylindrical reactor with commercial titanium dioxide (TiO2) as the reference photocatalyst and using mostly FVL for illumination. For comparison only, a UV (black) light lamp was used. The gas-phase products were detected and quantified online by gas chromatography (GC). The effects of reactor residence time, of inlet concentration, and of the relative light intensity on the efficiency of the process were also evaluated. At a high n-butanol concentration (0.1 vol %), butanal and propanal were identified as the intermediate products of the process; ethanal appeared when the initial concentration was < or = 850 ppm(v). This indicates that PCO leading to CO2 and H2O is relatively slow and proceeds in a stepwise manner. Although the efficiency of the process with an FVL lamp was significantly lower than when using a UV black light, complete PCO of low concentrations was achieved for 100 ppm(v). In a search for a material with photoactivation extended to higher wavelengths or increased photoactivity, several samples of transition metal- or silver ion-doped (2 atomic %) TiO2 as well as SrTi(1-x-)Fe(x)O3 (x = 0.1 and 0.15) perovskites were included in the study. None of these materials was more active than pure TiO2. The results of this study open new horizons in the area of in door air quality (IAQ) control.  相似文献   

13.
A speciated, hourly, and gridded air pollutants emission modeling system (SHEMS) was developed and applied in predicting hourly nitrogen dioxide (NO2) and ozone (O3) levels in the Seoul Metropolitan Area (SMA). The primary goal of the SHEMS was to produce a systemized emission inventory for air pollutants including ozone precursors for modeling air quality in urban areas. The SHEMS is principally composed of three parts: (1) a pre-processor to process emission factors, activity levels, and spatial and temporal information using a geographical information system; (2) an emission model for each source type; and (3) a post-processor to produce report and input data for air quality models through database modeling. The source categories in SHEMS are point, area, mobile, natural, and other sources such as fugitive emissions. The emission database produced by SHEMS contains 22 inventoried compounds: sulfur dioxide, NO2, carbon monoxide, and 19 speciated volatile organic compounds. To validate SHEMS, the emission data were tested with the Urban Airshed Model to predict NO2 and O3 concentrations in the SMA during selected episode days in 1994. The results turned out to be reliable in describing temporal variation and spatial distribution of those pollutants.  相似文献   

14.
在自建的脉冲喷吹实验台上,利用Y—YD-7044型压电式传感器和MYD-8801加速度传感器,测试0120×2000mm覆PTFE膜无纺布滤袋在不同喷吹压力下,加文丘里与不加文丘里时的最大侧壁压力峰值和最大反向加速度,并对比计算了获得同样清灰强度时的脉冲阀一次喷吹耗气量。结果显示,添加文丘里能显著增大滤袋中下部最大侧壁压力峰值和整条滤袋上的最大反向加速度,即提高脉冲喷吹清灰强度;对应同样的喷吹压力,加文丘里时的平均最大侧壁压力峰值和平均最大反向加速度比不加文丘里时分别平均提高大约70%和50%;加文丘里获得同样清灰强度时的脉冲阀一次喷吹耗气量比不加文丘里时节省40%左右。证实对于脉冲喷吹清灰系统,添加文丘里能有效改善清灰效果以及减小能量?肖耗。  相似文献   

15.
Olajire AA  Azeez L  Oluyemi EA 《Chemosphere》2011,84(8):1044-1051
We measured toxic air pollutants along Oba Akran road in Lagos to evaluate pedestrian exposure. PM10, CO, O3, NO2, SO2, CH4, noise, wind velocity and temperature were measured simultaneously with portable analyzers. Our results showed that pedestrian exposure to PM10 (with an average of 274.6 μg m−3 for all samples) and CO (with an average of 19.27 ppm for all samples) was relatively high. CO is a traffic-related pollutant, so the influence of the local traffic emissions on CO levels is strong. The high concentration of the PM10 measured at the three environments also suggests that the traffic is a major source of ultrafine particles. The overall average concentrations for the 72-day experimental period for SO2, NO2 and O3 are 101.2, 62.5 and 0.32 ppb respectively, all of which are below the US national ambient air quality standards. Strong traffic impacts can be observed from the concentrations of some of these pollutants measured in these three environments. Most clear is a reflection of diesel truck traffic activity rich in black carbon concentrations. The diurnal variation of O3 and NO2 also showed that NO2 was depleted by photochemically formed O3 during the day and replenished at night as O3 was destroyed. A multivariate statistical analysis (Principal Component Analysis, Factor Analysis) has been applied to a set of data in order to determine the contribution of different sources. It was found that the main principal components, extracted from the air pollution data, were related to gasoline combustion, oil combustion and ozone interactions.  相似文献   

16.
The objectives of this study were to describe trends in ambient air quality in Tehran between 1988 and 1993, to determine if these levels exceeded the World Health Organization (WHO) guidelines, and to discuss possible health effects related to exposure for these particular pollutants. Data were acquired from Iran's Environmental Protection Agency (IEPA) and the Ministry of Health (MH). These agencies operate five automated ambient air monitoring stations located in areas with heavy traffic. Daily samples of SO2, NO2, CO, total suspended particulate matter (TSM), and hydrocarbons (HC) were collected to provide 24 hour averages for each pollutant. Every three months, mean concentrations were reported to IEPA. Composite samples from all five stations were stored in a databank operated by IEPA. The ambient air quality guidelines were obtained from WHO reports. Statistical analysis was carried out using a regression model, which was designed to fit the air pollution data and take into account missing data. The results showed that there was a statistically significant upward trend in air pollution levels for all of the measured pollutants, except NO2, during the years 1988 to 1993. WHO guidelines were routinely and substantially exceeded by all pollutants except TSM. These findings suggest that as the population continues to grow, and increasing numbers of motor vehicles are driven in Tehran, there is concern for the health effects that may result from exposure to these pollutants.  相似文献   

17.
Vapor- and particulate-phase polycyclic aromatic hydrocarbon (PAH) samples were continuously collected at an urban site in Dalian, China, during the heating and non-heating period. There is strong temperature dependence and obvious seasonal trend for atmospheric PAHs, and significant positive correlations of atmospheric PAHs with SO2 and CO concentrations were observed. Factor analysis model with non-negative constraints (FA–NNC) combined with local and literature PAH source fingerprints was successful in source identification of particulate PAHs in the atmospheric samples. The results suggested that, in heating period, the main pollution sources were identified as coal-fired boiler emission (56%), residential coal combustion (33%) and traffic emissions (11%). As for non-heating period, the main sources were gasoline engine emission, traffic tunnel emission and coal-fired power plant, and the overall source contributions of traffic emission (gasoline engine + traffic tunnel) were 79% and coal-fired power plant 21%. The current results support our previous study and provide new insights. This can be the first attempt to quantitatively apportion air organic pollutants using receptor models combined with local source fingerprints. The source fingerprints can be used as reference data for source apportionment of atmospheric PAHs of China.  相似文献   

18.
汽车内微环境空气污染的初步探究   总被引:1,自引:1,他引:1  
为了研究车内的污染水平,在2004-04-10至2004-06-20对车内空气进行了采样和分析.对车龄在2年内的91种型号轿车的车内微环境进行了静态检测,有效检测车辆共计802辆,同时对比检测20辆2002年以前出厂的旧车.检测项目包括甲醛、苯、甲苯、二甲苯和CO等.参照国家室内空气质量标准,新车中甲苯浓度超标率达82%,苯和甲醛浓度的超标率分别为75%和24%.在被检测车辆中,甲醛、苯、甲苯和二甲苯浓度均是新车比旧车高,只有CO浓度是旧车比新车高.初步分析判断苯系物主要来源于车内的胶粘剂,甲醛来自于车椅座套和座垫等,CO来源于发动机排放残留.  相似文献   

19.
Data are lacking on human exposure to air pollutants occurring in ground-level outdoor environments within a few meters of point sources. To better understand outdoor exposure to tobacco smoke from cigarettes or cigars, and exposure to other types of outdoor point sources, we performed more than 100 controlled outdoor monitoring experiments on a backyard residential patio in which we released pure carbon monoxide (CO) as a tracer gas for continuous time periods lasting 0.5–2 h. The CO was emitted from a single outlet at a fixed per-experiment rate of 120–400 cc min?1 (~140–450 mg min?1). We measured CO concentrations every 15 s at up to 36 points around the source along orthogonal axes. The CO sensors were positioned at standing or sitting breathing heights of 2–5 ft (up to 1.5 ft above and below the source) and at horizontal distances of 0.25–2 m. We simultaneously measured real-time air speed, wind direction, relative humidity, and temperature at single points on the patio. The ground-level air speeds on the patio were similar to those we measured during a survey of 26 outdoor patio locations in 5 nearby towns. The CO data exhibited a well-defined proximity effect similar to the indoor proximity effect reported in the literature. Average concentrations were approximately inversely proportional to distance. Average CO levels were approximately proportional to source strength, supporting generalization of our results to different source strengths. For example, we predict a cigarette smoker would cause average fine particle levels of approximately 70–110 μg m?3 at horizontal distances of 0.25–0.5 m. We also found that average CO concentrations rose significantly as average air speed decreased. We fit a multiplicative regression model to the empirical data that predicts outdoor concentrations as a function of source emission rate, source–receptor distance, air speed and wind direction. The model described the data reasonably well, accounting for ~50% of the log-CO variability in 5-min CO concentrations.  相似文献   

20.
The goal of this study was to investigate the potential for atmospheric Hg degrees uptake by grassland species as a function of different air and soil Hg exposures, and to specifically test how increasing atmospheric CO(2) concentrations may influence foliar Hg concentrations. Four common tallgrass prairie species were germinated and grown for 7 months in environmentally controlled chambers using two different atmospheric elemental mercury (Hg major; 3.7+/-2.0 and 10.2+/-3.5 ng m(-3)), soil Hg (<0.01 and 0.15+/-0.08 micro g g(-1)), and atmospheric carbon dioxide (CO(2)) (390+/-18, 598+/-22 micro mol mol(-1)) exposures. Species used included two C4 grasses and two C3 forbs. Elevated CO(2) concentrations led to lower foliar Hg concentrations in plants exposed to low (i.e., ambient) air Hg degrees concentrations, but no CO(2) effect was apparent at higher air Hg degrees exposure. The observed CO(2) effect suggests that leaf Hg uptake might be controlled by leaf physiological processes such as stomatal conductance which is typically reduced under elevated CO(2). Foliar tissue exposed to elevated air Hg degrees concentrations had higher concentrations than those exposed to low air Hg degrees , but only when also exposed to elevated CO(2). The relationships for foliar Hg concentrations at different atmospheric CO(2) and Hg degrees exposures indicate that these species may have a limited capacity for Hg storage; at ambient CO(2) concentrations all Hg absorption sites in leaves may have been saturated while at elevated CO(2) when stomatal conductance was reduced saturation may have been reached only at higher concentrations of atmospheric Hg degrees . Foliar Hg concentrations were not correlated to soil Hg exposures, except for one of the four species (Rudbeckia hirta). Higher soil Hg concentrations resulted in high root Hg concentrations and considerably increased the percentage of total plant Hg allocated to roots. The large shifts in Hg allocation patterns-notably under soil conditions only slightly above natural background levels-indicate a potentially strong role of plants in belowground Hg transformation and cycling processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号