首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 171 毫秒
1.
磷酸铵镁--混凝深度处理垃圾渗滤液实验研究   总被引:3,自引:2,他引:1  
采用磷酸铵镁—混凝法对广东某环保发电厂经混凝-生化处理后的垃圾渗滤液进行深度处理,实验结果表明:磷酸铵镁在渗滤液pH为10.5,Mg∶P∶N=1.8∶1.6∶1条件下沉淀效果较好;以硫酸铁作为混凝剂,pH=7,混凝剂(5%)为23mL,沉淀时间为45min时处理水COD为225mg/L,氨氮10.5mg/L,总磷0.21mg/L,可达《生活垃圾渗滤液排放限值》(GB16889-1997)的二级排放标准。  相似文献   

2.
采用Fe/C微电解-Fenton氧化联合工艺处理某固体废弃物处理企业填埋区的垃圾渗滤液,以降低其COD与浊度值,并去除渗滤液中的重金属离子。结果表明:当pH=4~5,铁炭复合材料投加量为30~40 g/L,曝气量为40 L/min,水力停留时间(HRT)为1 h时,微电解方法对垃圾渗滤液中的Ni2+、Cr(Ⅵ)、Pb2+的去除效果较好,其去除率分别达到 96%、97%和96%,垃圾渗滤液色度去除率为92.41%,COD去除率为62.33%,浊度由40.73NTU降至3.09 NTU,COD由579.2 mg/L降至218.16 mg/L。对微电解工艺出水进一步采用Fenton氧化工艺处理,结果表明:当Fe2+浓度为0.007 mol/L,氧化时间为90 min,n(H2O2):n(Fe2+)=1.2:1条件下,COD去除率为67.50%,浊度为53.20%,处理后的出水浊度为1.47 NTU、COD为69.49 mg/L,达到GB 18918-2002《城镇污水处理厂污染物排放标准》的二级排放标准。  相似文献   

3.
为了解决垃圾渗滤液的脱氮难题,通过改变SBR的操作模式对渗滤液进行处理.同时,试验重点考察了操作模式、曝气时溶解氧、过曝气以及渗滤液碳氮比对工艺脱氮效果的影响.研究结果表明,采用改进SBR对渗滤液进行处理,在原水COD浓度为4000mg/L左右,氨氮浓度为1000mg/L左右,总氮浓度在1100mg/L左右的条件下,不添加任何碳源,出水COD小于500mg/L,氨氮浓度小于5mg/L,总氮浓度小于40mg/L,COD、氨氮和总氮的去除率分别达到了85%、99%和95%以上.影响因素试验表明,反硝化菌中的PHA含量是影响系统脱氮效率的关键.曝气时较高的溶解氧、曝气前的厌氧搅拌以及尽量减少过曝气将提高系统的脱氮效率.同时,只要渗滤液碳氮比大于4,系统均可以对渗滤液实现深度脱氮.  相似文献   

4.
Fenton氧化法深度处理垃圾渗滤液的试验研究   总被引:1,自引:0,他引:1  
采用Fenton氧化法对经生化处理后的垃圾渗滤液进行深度处理。结果表明,Fenton反应最佳工艺条件:初始pH值为3,H2O2加入量为3.0mL/L,FeSO4.7H2O加入量为3.5g/L,反应时间120min。生化处理后的垃圾渗滤液经Fenton氧化法深度处理后,CODCr由处理前的300mg/L,降至处理后的93mg/L,去除率达69.0%,出水水质达到新修订的《生活垃圾填埋场污染控制标准》(GB16889-2008)排放标准。  相似文献   

5.
催化臭氧氧化预处理垃圾渗滤液   总被引:2,自引:0,他引:2  
采用浸渍法制备载铜活性炭催化剂,系统地研究了催化氧化法对垃圾渗滤液中的COD和氨氮去除效果,对臭氧氧化和催化臭氧氧化效率进行了对比。在该方法下制备的催化剂中,活性组分金属铜的含量为2.89%。结果表明:在投加催化剂的情况下,COD的去除效率可得到显著提高。实验结果表明:处理COD为4980mg/L,氨氮为2100mg/L的垃圾渗滤液废水,在室温、pH为3、反应时间为120min、催化剂投加量为150g/L、臭氧的流量为5.2mg/min的条件下,废水中的COD及氨氮的去除率分别达到达81.9%和99.04%。  相似文献   

6.
为了探索高效垃圾渗滤液处理工艺,采用生物接触氧化—电絮凝工艺处理垃圾渗滤液。试验结果表明,生物接触氧化—电絮凝工艺适于处理COD<5000mg/L的垃圾渗滤液,最高容积负荷可达6.56kgCOD/(m3.d),对COD去除率最高可达84.63%,平均BOD去除率可达91.25%,对NH4-N去除率最高可达86.13%,处理后的垃圾渗滤液可达到国家垃圾渗滤液二级排放标准。处理费用估算为10元/m3。  相似文献   

7.
垃圾渗滤液处理工程实例   总被引:1,自引:0,他引:1  
利用厌氧UASB+膜生物反应器MBR+纳滤工艺处理垃圾填埋场产生的垃圾渗滤液,介绍了各处理阶段的设计、运行参数和经济技术指标,设计处理规模为100 m3/d。在进水ρ(COD)为10 000 mg/L,ρ(BOD5)为5 000 mg/L,经处理后,出水ρ(COD)达到60 mg/L,ρ(BOD5)约为20 mg/L,去除率分别达到99.4%、99.6%,且出水稳定,达到地方标准DB 11/307-2005《北京市水污染排放标准》中二级排放标准。  相似文献   

8.
白轩  潘大伟  王翠艳  胡筱敏 《环境工程》2013,(Z1):285-287,291
对辽宁省鞍山市某生活垃圾卫生填埋场的晚期垃圾渗滤液进行预处理,选择MgO和磷矿粉两种矿物,利用共沉淀法去除垃圾渗滤液中的氨氮,用于制备磷铵镁复合肥,实现垃圾渗滤液的资源化利用。实验结果如下:MgO与磷矿粉配合使用,能够较好地去除垃圾渗滤液中COD和氨氮。采用MgO、磷矿粉共沉淀法生成磷铵镁复合肥具有可行性,同时可为后续生化处理创造良好的条件;在给定条件下(氨氮浓度1200 mg/L,COD 3180 mg/L),垃圾渗滤液COD去除的最优实验条件为MgO添加量5.0 g/L、磷矿粉添加量100 g/L,反应时间4 h,处理后COD去除率为62.1%,氨氮去除率为87.5%;氨氮去除的最优实验条件为MgO添加量10 g/L、磷矿粉添加量60 g/L、反应时间4 h,处理后COD去除率为42.1%,氨氮去除率为96.1%。  相似文献   

9.
改性膨润土预处理垃圾渗滤液试验研究   总被引:2,自引:0,他引:2  
以溴化十六烷基三甲基胺为改性剂制备了有机改性膨润土,并对其进行了性能表征。将其应用于COD高达20000~37000mg/L的垃圾渗滤液的预处理,以垃圾渗滤液的COD去除率为考察指标,对原土和有机改性土的处理效果进行了对比,确定了改性膨润土最佳用量以及最佳反应条件。研究结果表明,有机改性膨润土处理效果明显优于原土。在改性土用量为30g/L,pH值为5左右,搅拌时间为40min,静置时间为30min时,能够使垃圾渗滤液的COD去除率达到67%以上,减轻了下一步生物处理的负荷。  相似文献   

10.
文章通过自制的铁系絮凝剂聚硅酸硫酸铁(PFSS)对垃圾渗滤液进行预处理,再用电解法进行深度处理,实验考察了絮凝剂投加量、电解时间、电压、pH等因素对垃圾渗滤液处理效果的影响。实验结果表明:絮凝法/电解法对垃圾渗滤液有良好的处理效果,在絮凝剂聚硅酸硫酸铁(PFSS)投加量为3.7mL/L、电解时间40min、电压4.0V、pH值为3.0条件下,其COD、NH4+-N、色度的去除率分别可达到76.47%、54.95%、93.89%。其中COD、色度已达到国家二级排放标准。  相似文献   

11.
高氮渗滤液缺氧/厌氧UASB-SBR工艺低温深度脱氮   总被引:7,自引:1,他引:6       下载免费PDF全文
在低温条件下,采用缺氧/厌氧UASB-SBR组合工艺处理实际垃圾填埋场渗滤液.结果表明,该工艺可实现有机物和氮的同步、深度去除.在进水COD平均为11950.2mg/L,NH4+-N为982.7mg/L的条件下,出水分别为390.1mg/L和2.9mg/L,去除率分别为96.7%和99.7%.同时,缺氧UASB1反应器的最大COD负荷达到13kg/(m3×d),最大COD去除速率为12.39 kg/(m3×d),具有高效缺氧反硝化和高效厌氧降解有机物反应的双重功效, 在SBR反应器的缺氧段和缺氧UASB,反应器内获得了99%以上的反硝化率.对于冬季水温分别为14.9,14.1,13.5,11.05℃的低温条件下,SBR反应器实现了完全硝化和反硝化,出水TN分别为4.1,5.7,14.1,16.5mg/L,达到了深度脱氮的目的.此外,在上述温度范围内,温度对反硝化速率(rN)的影响大于对硝化速率 (rDN)的影响, rN/rDN比值相对恒定.  相似文献   

12.
Nitrogen removal via nitrite from municipal landfill leachate   总被引:2,自引:0,他引:2  
A system consisting of a two-stage up-flow anaerobic sludge blanket (UASB), an anoxic/aerobic (A/O) reactor and a sequencing batch reactor (SBR), was used to treat landfill leachate. During operation, denitrification and methanogenesis took place simultaneously in the first stage UASB, and the e uent chemical oxygen demand (COD) was further removed in the second stage UASB. Then the denitrification of nitrite and nitrate in the returned sludge by using the residual COD was accomplished in the A/O reactor, and ammonia was removed via nitrite in it. Last but not least, the residual ammonia was removed in SBR as well as nitrite and nitrate which were produced by nitrification. The results over 120 d (60 d for phase I and 60 d for phase II) were as follows: when the total nitrogen (TN) concentration of influent leachate was about 2500 mg/L and the ammonia nitrogen concentration was about 2000 mg/L, the shortcut nitrification with 85%–90% nitrite accumulation was achieved stably in the A/O reactor. The TN and ammonia nitrogen removal e ciencies of the system were 98% and 97%, respectively. The residual ammonia, nitrite and nitrate produced during nitrification in the A/O reactor could be washed out almost completely in SBR. The TN and ammonia nitrogen concentrations of final e uent were about 39 mg/L and 12 mg/L, respectively.  相似文献   

13.
A two-stage upflow anaerobic sludge blanket(UASB) and sequencing batch reactor(SBR) system was introduced to treat landfill leachate for advanced removal of COD and nitrogen at low temperature.In order to improve the total nitrogen(TN) removal efficiency and to reduce the COD requirement for denitrification,the raw leachate with recycled SBR nitrification supernatant was pumped into the first-stage UASB(UASB1) to achieve simultaneous denitrification and methanogenesis.The results showed that UASB1 played an important role in COD removal and UASB2 and SBR further enhanced the nutrient removal efficiency.When the organic loading rates of UASB1,UASB2 and SBR were 11.95,1.63 and 1.29 kg COD/(m3·day),respectively,the total COD removal efficiency of the whole system reached 96.7%.The SBR acted as the real undertaker for NH4+-N removal due to aerobic nitrification.The system obtained about 99.7% of NH4+-N removal efficiency at relatively low temperature(14.9-10.9°C).More than 98.3% TN was removed through complete denitrification in UASB1 and SBR.In addition,temperature had a significant effiect on the rates of nitrification and denitrification rather than the removal of TN and NH4+-N once the complete nitrification and denitrification were achieved.  相似文献   

14.
本文采用厌氧反应器UASB+膜生物反应器MBR+纳滤工艺处理垃圾填埋场废水,设计处理能力为100m3/d,在进水CODs:和BODs分别为10 000 mg/L和5 000 mg/L时,经处理后,出水CODc:和BODs分别为60mg/L和20mg/L,其去除率分别为99.4%和99.6%,且出水稳定,达到了<北京市水...  相似文献   

15.
不同基质浓度下SBR进水方式对厌氧氨氧化的影响   总被引:5,自引:0,他引:5  
采用厌氧SBR反应器,分别以配水培养和以实际晚期垃圾渗滤液培养的厌氧氨氧化菌为研究对象,考察了不同基质浓度下,SBR改进式连续进水方式与一次性进水方式对厌氧氨氧化工艺运行性能的影响.结果表明,当处理人工配水时,在中低进水浓度下(NO2--N£400mg/L),与改进式连续进水方式相比,宜采用一次性进水方式运行;在高进水浓度下(NO2--N3400mg/L)改进式连续进水方式比一次性进水方式优势明显,特别是在5h改进式连续进水方式下,平均比污泥脱氮速率增加至39.11mgN/(gVSS·h),相比一次进水方式效率提高40%.当处理进水NO2--N浓度为(300±20)mg/L的实际晚期垃圾渗滤液时, 5h改进式连续进水的SBR比污泥脱氮速率最高.由于晚期渗滤液较配水成分复杂,使得厌氧氨氧化菌面临有机物和有害物质的影响,其厌氧氨氧化的反应速率低于同等基质浓度配水条件下的厌氧氨氧化反应速率.  相似文献   

16.
电催化系统-电生物炭接触氧化床处理垃圾渗滤液   总被引:17,自引:1,他引:17       下载免费PDF全文
 提出了电催化系统(ECS)组合电生物炭接触氧化床(EBACOR)来处理垃圾渗滤液的方法.结果表明,ECS-EBACOR法诸多的影响因素中,对处理效率影响最大的是ECS的电活性催化填料组分.GC/MS分析结果表明,垃圾渗滤液中的64种有毒有机污染物经ECS处理后,大部分已被矿化成CO2、H2O或降解为小分子有机物.ECS-EBACOR现场运行试验结果还表明,当垃圾渗滤液废水中的COD和NH3-N浓度分别在3000~5000mg/L以及1100~1780mg/L范围时,COD和NHs3-N去除率均可超过90%.  相似文献   

17.
微波催化氧化法预处理垃圾渗滤液的研究   总被引:6,自引:0,他引:6       下载免费PDF全文
采用微波-活性炭-Fenton催化氧化预处理垃圾渗滤液,研究了不同因素对垃圾渗滤液处理效果的影响.结果表明,COD和氨氮去除率随活性炭用量、微波辐射时间和微波功率增加而增加;随Fe2+用量和H2O2用量增加,COD和氨氮去除率先增加而后下降;随pH值增加,氨氮去除率显著增加,COD去除率变化不明显.在微波功率为300W,pH值为8,活性炭9g/L,Fe2+用量为0.02mol/L,H2O2用量为7mL/L,辐射时间6min条件下,垃圾渗滤液中COD和氨氮去除率分别达到68.22%和78.08%,SS去除率达到78.55%,浑浊度去除率达到99.02%,颜色由黑褐色去除为接近无色,BOD5/COD由0.21提高到0.45;研究比较了不同处理对垃圾渗滤液的处理效果.结果显示,微波催化氧化对垃圾渗滤液中COD和氨氮去除率明显高于其他处理.  相似文献   

18.
垃圾渗滤液处理工艺改进的研究   总被引:1,自引:0,他引:1  
李定龙 《环境工程》2004,22(5):19-21
针对武进夹山垃圾填埋场渗滤液处理工艺设计及运行过程中存在的问题 ,提出了厌氧与SBR 混凝法相结合的渗滤液处理工艺改进方案。研究表明 :SBR及混凝处理的CODCr最大降解率分别达 4 2 5 %、6 3 0 % ,SBR法正交试验得出的最佳工艺条件是 :曝气时间 30h ,闲置时间 6h ,污泥浓度 5 0mg L ;化学混凝对SBR法处理的出水有较好处理效果 ,其最佳进水pH值应控制在 9 0左右。最后 ,结合填埋场现有的处理工艺及运行现状 ,对处理工艺改进方案进行了讨论。  相似文献   

19.
厌氧消化是垃圾渗滤液处理的重要技术,常规厌氧工艺在处理过程中存在微生物易流失和出水水质较差等问题。采用厌氧膜生物反应器在中温条件下处理垃圾渗滤液,考察了废水降解性能和膜过滤性能。连续100 d的反应器运行实验表明:在水力停留时间为10 d,COD容积负荷平均为5.63 kg/(m3·d)的条件下,系统运行稳定,平均COD去除率达到92%,膜出水总挥发性脂肪酸浓度低于200 mg/L,pH稳定在7.95左右。在膜通量为6 L/(m2·h)下,连续62 d内的膜压增长缓慢,未出现明显的膜污染。批次产甲烷试验结果表明:渗滤液产甲烷潜能达到305 mL/g TS,与连续运行实验296 mL/g TS的产气效果接近,沼气中甲烷浓度可高达70%~80%。产气达到90%和95%的潜能分别用时2.5,3.1 d,说明反应器有进一步缩短水力停留时间的可能性。反应器驯化的厌氧活性污泥对乙酸有较好的耐受性,在乙酸浓度为10000 mg/L时,产气迟滞期仅为1.4 d。综合来看,长期运行厌氧膜生物反应器处理垃圾渗滤液具有较好的COD去除效果、运行稳定性和膜过滤性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏