1.
A turbulent wet scrubber was designed and developed to scrub particulate matter (PM) at micrometer and submicrometer levels from the effluent gas stream of an industrial coal furnace. Experiments were conducted to estimate the particle removal efficiency of the turbulent scrubber with different gas flow rates and liquid heads above the nozzle. Particles larger than 1 µm were removed very efficiently, at nearly 100%, depending upon the flow rate, the concentration of the dust-laden air stream, and the water level in the reservoir. Particles smaller than 1 µm were also removed to a greater extent at higher gas flow rates and for greater liquid heads. Pressure-drop studies were also carried out to estimate the energy consumed by the scrubber for the entire range of particle sizes distributed in the carrier gas. A maximum pressure drop of 217 mm H2O was observed for a liquid head of 36 cm and a gas flow rate of 7 m3/min. The number of transfer units (NTU) analysis for the efficiencies achieved by the turbulent scrubber over the range of particles also reveals that the contacting power achieved by the scrubber is better except for smaller particles. The turbulent scrubber is more competent for scrubbing particulate matter, in particular PM2.5, than other higher energy or conventional scrubbers, and is comparable to other wet scrubbers of its kind for the amount of energy spent.

Implications: The evaluation of the turbulent scrubber is done to add a novel scrubber in the list of wet scrubbers for industrial applications, yet simple in design, easy to operate, with better compactness, and with high efficiencies at lower energy consumption. Hence the turbulent scrubber can be used to combat particulate from industrial gaseous effluents and also has a scope to absorb gaseous pollutants if the gases are soluble in the medium used for particles capture.  相似文献   

2.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

3.
Collection efficiencies are shown for control of fine particles in venturi scrubbers (1) as a function of pressure drop, and (2) as a function of throat area and liquid to gas ratio. A relationship of pressure drop to throat area, gas density, throat velocity, and liquid to gas ratio is given and is used to provide a method for estimating efficiency knowing only these scrubber design parameters. The effect of charged particles and of surface active agents on collection efficiency are discussed briefly.  相似文献   

4.
Choi KI  Lee DH  Osako M  Kim SC 《Chemosphere》2007,66(6):1131-1137
Wet scrubber is one of the most conventional types of air pollutant control devices (APCDs), which is specially designed to treat dust and acidic gases in the flue gas simultaneously. In spite of its outstanding ability to control them, however, wet scrubbers have been considered as potential contaminant sources that may increase PCDD/DF concentrations in the flue gas. In this study, we investigated the change of PCDD/DF concentrations at the inlets and outlets of seven wet scrubbers, and compared them with other published data. With a multi-regression analysis of dust concentrations and temperature at the inlets and outlets of given wet scrubbers, we developed an empirical model to understand factors dominating the change of PCDD/DF concentrations. As a result, we confirmed that the changes of PCDD/DF concentrations in wet scrubbers are closely related to their concentrations at the inlets, which would usually be determined by the type of APCDs installed upstream of the wet scrubber.  相似文献   

5.
In order to address the bottleneck problem of low fine-particle removal efficiency of self-excited dust scrubbers, this paper is focused on the influence of the intermittent gas-liquid two-phase flow on the mesoscale behavior of collector aggregations. The latter is investigated by the application of high-speed dynamic image technology to the self-excited dust scrubber experimental setup. The real-time-scale monitoring of the dust removal process is provided to clarify its operating mechanism at the mesoscale level. The results obtained show that particulate capturing in self-excited dust scrubber is provided by liquid droplets, liquid films/curtains, bubbles, and their aggregations. Complex spatial and temporal structures are intrinsic to each kind of collector morphology, and these are considered as the major factors controlling the dust removal mechanism of self-excited dust scrubbers. For the specific parameters of gas-liquid two-phase flow under study, the evolution patterns of particular collectors reflect the intrinsic, intermittent, and complex characteristics of the temporal structure. The intermittent initiation of the collector and the air hole formation-collapse cyclic processes provide time and space for the fine dust to escape from being trapped by the collectors. The above mesoscale experimental data provide more insight into the factors reducing the dust removal efficiency of self-excited dust scrubbers.

Implications: This paper focuses on the reconsideration of the capturer aggregations of self-excited dust scrubbers from the mesoscale. Complex structures in time and space scales exist in each kind of capturer morphology. With changes of operating parameters, the morphology and spatial distributions of capturers diversely change. The change of the capturer over time presents remarkable, intermittent, and complex characteristics of the temporal structure.  相似文献   


6.
The overall particle collection efficiencies of spray scrubbers using monodisperse droplets of 100,500, and 1000 microns diameter were calculated for the cases of evaporating and condensing droplets. The properties of the gas at the inlet to the spray scrubber were maintained constant at 150°F, 100% relative humidity, and 1 atmosphere pressure. At the liquid entrance to the spray scrubber, the water droplet temperature was 50° F for the condensing case and 180° F for the evaporating case. The liquid to gas flow rate ratio for all the calculations was held constant at 4 gal/1000 acf. The gas velocity in the co-current spray tower was 1 ft/sec in the downwind direction. The calculation results show that for the particles in the 0.01 to 10 Mm diameter range, the overall spray scrubber particle collection efficiency is greater with the cooler 50°F water (condensing case) than with the warmer 180°F water (evaporating case). The effect of diffusiophoresis and thermophoresis is noticeable for all the water droplet sizes considered, but is more significant for the larger water droplets. This greater effect for the larger water droplets compared to the smaller droplets is due to the longer existence of the temperature and water vapor concentration gradients between the water droplets and the surrounding gas.  相似文献   

7.
The exact collection mechanism of a venturi scrubber has been unknown up to this time. Photographic stop-action techniques and glass venturi scrubbers have made it possible to establish where and how particles are captured and to speculate on possible gas removal possibilities. This report extends the knowledge of pneumatic atomization which is used in gas scrubbing and many other applications by providing further information on cloud-type atomization. Cloud-type atomization which is produced by pneumatic atomization of liquid streams (not drops) results in the formation of liquid droplets which appear to be less than 10 microns in diameter. These droplets coalesce and form clouds which move as single entities. Effective overall cloud diameters are determined to be a function of the velocity of the atomizing gas stream. The effective cloud diameters start at 170 [a and increase as throat gas velocities increase from 150 ft/sec. Throat velocities and liquid inlet nozzle diameters necessary to obtain water clouds of specific effective diameters can be estimated.

These large clouds are efficient impaction targets and stop most of the particulate matter within 0.5 cm from the throat scrubbing liquid inlets. High gas absorption is expected for the clouds of droplets because turbulent gas movement can exist inside and outside the clouds and the 10 μ droplets provide exceptional surface area.  相似文献   

8.
Theoretical calculations and experimental measurements show that the collection of small aerosol particles (0.05 to 5 micron diameter range) by water droplets in spray scrubbers can be substantially increased by electrostatically charging the droplets and particles to opposite polarity. Measurements with a 140 acfm two chamber spray scrubber (7 seconds gas residence time) showed an increase in the overall particle collection efficiency from 68.8% tit uncharged conditions to 93.6% at charged conditions, with a dioctyl phthalate aerosol (1.05 μm particle mass mean diameter and 2.59 geometric standard deviation). The collection efficiency for 0.3 μm particles increased from 35 to 87% when charged. During 1973–1974 a 1000 acfm pilot plant electrostatic scrubber was constructed inside a 40 ft trailer for evaluation on controlling particu-late emissions from pulp mill operations (funded by Northwest Pulp and Paper Association). Field tests performed on the particle emissions exhausting from SO2 absorption towers treating the gases from a magnesium based sulfite recovery boiler have shown particle collection efficiencies ranging from about 60 to 99% by weight, depending on the electrostatic scrubber operating conditions. Energy requirements for the University of Washington electrostatic scrubber are about 0.5 hp/1000 acfm (350 Watts/1000 acfm) including gas pressure drop, water pressure drop, and electrostatic charging of the water spray droplets and the particles.  相似文献   

9.
The purpose of this paper on industrial plan evaluation is twofold: to present tools which can be used to evaluate quantitatively certain aspects of air pollution control devices, and to point up specifically two areas in which research is urgently needed. These research areas are in removing solid particles after wetting in scrubbers and use of surface active agents in scrubbing gaseous pollutants. Therefore, the body of information presented is directed to engineers in the field of evaluating the air pollution potential of new industrial plants, to scientists involved in determining the parameters and effectiveness of control devices, and to research and development scientists in the field of surfactants.

One tool presented is a chart for measuring the effectiveness of incinerator afterburners and vapor incinerators. The required inputs to the chart are the rate of flue gas flow in standard cubic feet per minute and the auxiliary fuel burner capacity in Btu per hour. The chart yields the flue gas temperature increase which will result, given in degrees F. The second tool presented is a new psychrometric graph for the humidifying and cooling of gases from processes as hot as 3000°F. Inputs into the graph are the temperature of the gases entering the sprays from the hot process and the temperature desired before they enter a control device such as a fabric filter or a scrubber. The chart yield is the amount of water needed in gallons per thousand cubic feet of gas. The only calculation needed is a correction of the hot gas volume to 70°F. Water needed to saturate the gases can be read directly also.  相似文献   

10.
This is the conclusion of a 2-part article dealing with the technical aspects of lime/limestone scrubbers for coal-fired power plants, it covers instrumentation, participate removal and sludge disposal. Part I (June JAPCA) covered process chemistry and scrubber systems  相似文献   

11.
This 2-part article deals with the technical aspects of lime/limestone scrubbers for coal-fired power plants. Part I covers process chemistry and scrubber systems. Part II (next month) will cover instrumentation, particulate removal, and sludge disposal.  相似文献   

12.
Considerations for the engineering design of flux force/condensation (FF/C) scrubbers are reviewed. Fine par-ticulate removal in multiple sieve plate FF/C scrubbers is predicted, using mathematical design models. Results of experimental studies of two multiple sieve plate scrubbers for the removal of submicron particles are given. The published experimental data on FF/C scrubber performance are summarized. A preliminary analysis of the economics of FF/C scrubbers, compared to the conventional high energy scrubbers, defines the most favorable operating conditions for the application of FF/C scrubbers.  相似文献   

13.
During primary aluminum processing the molten aluminum is periodically fluxed with chlorine to separate impurities from the metal. The gaseous effluent from the chlorination process contains submicron particulates and gaseous vapors which produce a dense, white plume. The plume is acidic with hydrogen chloride and chlorine vapors, which cause a variety of corrosion problems. Since the stack discharge temperature can range as low as 200°F-and aluminum chloride sublimates at about 360°F, blockage of ductwork can also occur. For effective removal of both the particulates and chloride gases in the effluent, a sodium hydroxide solution is recommended. However, such a scrubbing liquor produces a flocculent precipitate. Therefore, a nonplugging type of scrubber is required. The solution UOP advanced was a “mobile packing” type of scrubber, utilizing a bed of polypropylene spheres in random, turbulent motion. The motion of the packing prevents plugging. The paper describes the design for such a system, describing the optimum use of ductwork, scrubber placement, gas saturation, and recirculation equipment. Instrumentation requirements, both minimum and optimum are discussed.  相似文献   

14.
Brick manufacturing industries are challenged to comply with clean air mandates. Dry air scrubbers have been used to remove acid gases from the exhaust air from brick manufacturing plants. The use of dry air scrubbers results in the production of large quantities of an alkaline powder by-product. A greenhouse experiment was conducted to evaluate the potential of using dairy lagoon sludge stabilized with the scrubber by-product as a soil amendment. Lagoon sludge was stabilized with scrubber by-product at an application rate of 20 gl(-1). The sludge-scrubber by-product mixture was applied to a sandy loam soil to provide amendments ranging between 28 and 168 kg of plant available nitrogen (PAN)/ha for the growth of Helianthus annuus (sunflower). Use of the sludge-scrubber by-product mixture as a nitrogen fertilizer did not adversely affect sunflower seedling emergence; however, significantly higher (p<0.05) plant volume indices, leaf area, dry shoot and root masses, and seed yields were obtained for mature plants grown in sludge-treated soil relative to the control or fertilizer treatment. The sludge amendment did not severely impact gas exchange or chlorophyll a fluorescence of the plants and nutrient content of the sunflower tissues was generally within a sufficient range. The increased growth and yield of sunflower plants indicated the potential of the sludge-scrubber by-product mixture as a soil amendment in agricultural crop production.  相似文献   

15.
The control of fugitive process emissions (FPE) with Spray Charging and Trapping (SCAT) scrubber was evaluated both theoretically and experimentally. The SCAT uses air curtain and/or jets to contain, convey, and divert the FPE into a charged spray scrubber.

Experiments were performed on an 8000 cfm bench-scale spray scrubber to verify the theory and feasibility of collecting fugitive particles with charged water spray. The effects of charge levels on drops and particles, nozzle type, drop size, gas velocity, and liquid/gas ratio on collection efficiency were determined experimentally. The results of the experiments and the comparison between theory and data are presented.

An air curtain was developed for conveying the FPE to the spray scrubber, deflecting the crosswind, and containing hot buoyant plume. The design and air flow field for the air curtain are presented.  相似文献   

16.
The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture. A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20-100%).  相似文献   

17.
With increasing attention on sulfuric acid emission, investigations on the removal characteristics of sulfuric acid aerosols by the limestone gypsum wet flue gas desulfurization (WFGD) system and the wet electrostatic precipitator (WESP) were carried out in two coal-fired power plants, and the effects of the WFGD scrubber type and the flue gas characteristics were discussed. The results showed that it was necessary to install the WESP device after desulfurization, as the WFGD system was inefficient to remove sulfuric acid aerosols from the flue gas. The removal efficiency of sulfuric acid aerosols in the WFGD system with double scrubbers ranged from 50% to 65%, which was higher than that with a single scrubber, ranging from 30% to 40%. Furthermore, the removal efficiency of WESP on the sulfuric acid aerosols was from 47.9% to 52.4%. With increased concentrations of SO3 and particles in the flue gas, the removal efficiencies of the WFGD and the WESP on the sulfuric acid aerosols were increased.

Implications: Investigations on removal of sulfuric acid aerosols by the WFGD and the WESP in the power plants were aimed at the control of sulfuric acid emission. The results showed that the improvement of the WFGD system was beneficial for the reduction of sulfuric acid emission, while the WESP system was essential to control the final sulfuric acid aerosol concentration.  相似文献   


18.
Abstract

The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture.

A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20–100%).  相似文献   

19.
Dimethyl disulphide (DMDS) removal was investigated in a compact scrubber (hydraulic residence time ≈20 ms), composed of a wire mesh packing structure where liquid and gas flow at co-current and high gas superficial velocity (>12 m s−1). In order to regenerate the scrubbing liquid and to maintain a driving force in the scrubber, ozone and hydrogen peroxide were added to water since they allow the generation of nonselective and highly reactive species, hydroxyl radicals HO. Three ways of reagent distribution were tested. The influence of several parameters (liquid flow rate(s), ozone flow rate, pH and reagent concentrations) was investigated. The best configuration was obtained when ozone is transferred in the scrubbing liquid before introduction at the top of the scrubber simultaneously with the hydrogen peroxide solution, allowing to generate hydroxyl radical in the scrubber. With this configuration, DMDS removal could be increased from 16% with water to 34% at the same gas and liquid flow rates in the scrubber showing the potentiality of advanced oxidation process.  相似文献   

20.
Abstract

This work presents a three-stage treatment system to process halogenated organic vent streams for compliance with the Hazardous Organic NESHAP (HON) Rule. The three stages are incineration, energy recovery, and wet scrubbing. In particular, this work concentrates on the design of the scrubber, which the HON Rule states must remove at least 99% of any halogens or hydrogen halides generated during the combustion step. Computerized process simulation was found to be ineffective in designing a scrubber for this application, so laboratory data on the partial pressure of the hydrogen halide species over aqueous solutions was employed. The number of overall gas transfer units required for 99% removal was found to be slightly less than 5, and the overall gas transfer unit height was found to be approximately 0.5 m.  相似文献   