首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Packing materials play a key role in the performance of bioreactors for waste gas treatment and particularly in biofilter applications. In this work, the performance of four differently packed biofilters operated in parallel for the treatment of relatively high inlet concentration of toluene was studied. The reactors were compared for determining the suitability of coconut fiber, digested sludge compost from a waste water treatment plant, peat and pine leaves as packing materials for biofiltration of toluene. A deep characterisation of materials was carried out. Biological activity and packing capabilities related to toluene removal were determined throughout 240 days of operation under different conditions of nutrients addition and watering regime. Also, biofilters recovering after a short shutdown was investigated. Nutrient addition resulted in improved removal efficiencies (RE) and elimination capacities (EC) of biofilters reaching maximum ECs between 75 and 95 g m(-3)h(-1) of toluene. In the first 80 days, the pH decreased progressively within the reactors, causing a population change from bacteria to fungi, which were the predominant decontaminant microorganisms thereafter. All reactors were found to recover the RE rapidly after a 5 days shutdown and, in a maximum of 7 days, all reactors had been completely recuperated. These results point out that fungal biofilters are a suitable choice to treat high loads of toluene. In general, coconut fiber and compost biofilters exhibited a better performance in terms of elimination capacity and long-term stability.  相似文献   

2.
Abstract

Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppmv), methyl ethyl ketone (12 ppmv), toluene (29 ppmv), ethylbenzene (10 ppmv), and p-xylene (10 ppmv). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m?3 hr?1 and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

3.
ABSTRACT

Thermophilic biodégradation of toluene with active compost biofilters was studied. Thermophilic conditions were maintained either by daily substrate addition (semicontinuous composting) or with a heating system (batch thermophilic composting). The semicontinuous system was designed for the treatment of cool (less than approximately 35 °C) gases under thermophilic conditions, while the extended batch approach was developed for the treatment of warmer gases. When the semicontinuous system was operated at 50 °C (after a one-day start-up period) at an average inlet concentration of 5.5 g m-3, toluene was degraded at a rate ranging from 73 to 110 g C m-3 hr-1. Batch thermophilic treatment was somewhat less effective at the same inlet concentration. Semicontinuous toluene biofiltration at 60 °C was also investigated, but biodegradation rates were significantly lower than at 50 °C. In all systems, toluene biodegradation was proportional to the inlet concentration. Rates of up to 289 g C m-3 hr-1 (at an inlet concentration of 14.7 g m-3) were achieved for semicontinuous and batch operation and 251 g C m-3 hr-1 (at an inlet concentration of 18.4 g m-3) for batch thermophilic at 50 °C. Semicontinuous thermophilic operation at 60 °C showed a maximum rate of 119 g C m-3 hr-1. Active compost ther-mophilic biofiltration was found to be very effective when concentrations are high. At lower concentrations, rates were similar to those obtained with mesophilic biofiltration. Mixing, humidity, and the presence of cosubstrate were important parameters in maintaining high degradation rates. Biofiltration in the batch thermophilic mode could be useful when conventional biofiltration is ineffective due to elevated gas temperatures. Biofiltration in the semicontinuous thermophilic could reduce the biofilter size necessary for treatment of cooler gases containing high concentrations of volatile organic compounds.  相似文献   

4.
ABSTRACT

Research was performed to demonstrate the removal of carbon tetrachloride (CT) using compost biofilters operated under methanogenic conditions. Biofilters were operated at an empty-bed residence time of 2.8 minutes using nitrogen as the atmosphere. Hydrogen and carbon dioxide were supplied as an electron donor and carbon source, respectively, during acclimation of the bed medium microbes. Once methanogenesis was demonstrated, CT flow to the biofilter was established. Biofilters were operated over a CT concentration range from 20 to 700 ppbv for 6 months. Bed medium microbes were able to remove up to 75% of the inlet CT. At excessively high CT concentrations (>500 ppmv), methane production and hydrogen utilization by the bed medium microbes appeared to be inhibited. CT removal by the biofilter decreased when the hydrogen supply was removed from the biofilter inlet, indicating that hydrogen acted as the electron donor for reductive dechlorination. The removal efficiency and relatively low empty bed residence times demonstrated by these laboratory-scale biofilters indicate that anaerobic biofiltration of CT may be a feasible full-scale process.  相似文献   

5.
6.
采用实验室规模的生物滤池对含硫化氢、氨和微生物气溶胶的气体进行处理,并对海绵、陶粒、堆肥和空心塑料小球4种物质作为反应器填料的性能进行比较。结果表明,不同填料生物滤池对硫化氢、氨和微生物气溶胶的去除效率明显不同,去除效率从高到低的顺序依次为海绵、陶粒、堆肥和空心塑料小球生物滤池。海绵和陶粒生物滤池出气异养细菌和真菌主要以小粒径粒子为主。在同样的进气和运行条件下,堆肥填料层的压力降最大,其次是陶粒和空心塑料小球填料层,海绵填料层的压力降最小。对4种填料的性能进行综合比较,海绵和陶粒较适宜作为处理硫化氢、氨和微生物气溶胶的生物滤池填料。  相似文献   

7.
ABSTRACT

Step tracer tests were carried out on lab-scale biofilters to determine the residence time distributions (RTDs) of gases passing through two types of biofilters: a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow. Results were used to define the flow patterns in the reactors. “Non-ideal flow” indicates that the flow reactors did not behave like either type of ideal reactor: the perfectly stirred reactor [often called a "continuously stirred tank reactor" (CSTR)] or the plug-flow reactor.

The horizontal biofilter with back-mixing was able to accommodate a shorter residence time without the usual requirement of greater biofilter surface area for increased biofiltration efficiency. Experimental results indicated that the first bed of the modified biofilter behaved like two CSTRs in series, while the second bed may be represented by two or three CSTRs in series. Because of the flow baffles used in the horizontal biofilter system, its performance was more similar to completely mixed systems, and hence, it could not be modeled as a plug-flow reactor. For the standard biofilter, the number of CSTRs was found to be between 2 and 9 depending on the airflow rate. In terms of NH3 removal efficiency and elimination capacity, the standard biofilter was not as good as the modified system; moreover, the second bed of the modified biofilter exhibited greater removal efficiency than the first bed. The elimination rate increased as biofilter load increased. An opposite trend was exhibited with respect to removal efficiency.  相似文献   

8.
Research was performed to demonstrate the removal of carbon tetrachloride (CT) using compost biofilters operated under methanogenic conditions. Biofilters were operated at an empty-bed residence time of 2.8 minutes using nitrogen as the atmosphere. Hydrogen and carbon dioxide were supplied as an electron donor and carbon source, respectively, during acclimation of the bed medium microbes. Once methanogenesis was demonstrated, CT flow to the biofilter was established. Biofilters were operated over a CT concentration range from 20 to 700 ppbv for 6 months. Bed medium microbes were able to remove up to 75% of the inlet CT. At excessively high CT concentrations (> 500 ppmv), methane production and hydrogen utilization by the bed medium microbes appeared to be inhibited. CT removal by the biofilter decreased when the hydrogen supply was removed from the biofilter inlet, indicating that hydrogen acted as the electron donor for reductive dechlorination. The removal efficiency and relatively low empty bed residence times demonstrated by these laboratory-scale biofilters indicate that anaerobic biofiltration of CT may be a feasible full-scale process.  相似文献   

9.
The purpose of this research was to neutralize livestock-generated ammonia by using biofilters packed with inexpensive inorganic and organic packing material combined with multicultural microbial load at typical ambient temperatures. Peat and inorganic supporting materials were used as biofiltration matrix packed in a perfusion column through which gas was transfused. Results show the ammonia removal significantly fell in between 99 and 100% when ammonia concentration of 200 ppmv was used at different gas flow rates ranged from 0.030 to 0.060 m3 h(-1) at a fluctuating room temperature of 27.5 +/- 4.5 C (Mean +/- SD). Under these conditions, the emission concentration of ammonia that is liberated after biofiltration is less than 1 ppmv (0.707 mg m(-3)) over the period of our study, suggesting the usage of low-cost biofiltration systems for long-term function is effective at wider ranges of temperature fluctuations. The maximum (100%) ammonia removal efficiency was obtained in this biofilter was having an elimination capacity of 2.217 g m(-3) h(-1). This biofilter had high nitrification efficiencies and hence controlled ammonia levels with the reduced backpressure. The response of this biofilter to shut down and start up operation showed that the biofilm has a superior stability.  相似文献   

10.
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.  相似文献   

11.
Abstract

Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media.  相似文献   

12.
Abstract

Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

13.
Effects of nitrogen and oxygen on biofilter performance   总被引:2,自引:0,他引:2  
Three laboratory-scale biofilters packed with inert material were used to study the nitrogen and oxygen requirements for biofiltration of methanol. Mixtures of methanol with inorganic nitrogen (NH3 or NO3) at nitrogen-to-carbon (N:C) ratios ranging from 0.015 to 0.4 were employed to reveal nitrogen effects on biofiltration. In the oxygen study, mixtures of air and oxygen at different oxygen contents were used. At low nitrogen levels, the removal rate increased with increasing N:C ratio for both NH3 and NO3. However, at high concentrations, NH3 had an inhibitory effect on biodegradation while the removal rate reached a plateau at high NO3 concentrations. Biofiltration with 63% oxygen in the inlet gas stream increased the maximum removal rate from 120 to 145 g/m3/hr after 3 days in comparison with biofiltration with air. However, a further increase in oxygen content up to 80% did not lead to a further improvement in biofilter performance, suggesting that both oxygen and biofilm thickness can be the relevant factors limiting biofilter performance and creating the plateau in removal rates at high loadings.  相似文献   

14.
采用实验室规模的生物滤池对含硫化氢、氨和微生物气溶胶的气体进行处理,并对海绵、陶粒、堆肥和空心塑料小球4种物质作为反应器填料的性能进行比较。结果表明,不同填料生物滤池对硫化氢、氨和微生物气溶胶的去除效率明显不同,去除效率从高到低的顺序依次为海绵、陶粒、堆肥和空心塑料小球生物滤池。海绵和陶粒生物滤池出气异养细菌和真菌主要以小粒径粒子为主。在同样的进气和运行条件下,堆肥填料层的压力降最大,其次是陶粒和空心塑料小球填料层,海绵填料层的压力降最小。对4种填料的性能进行综合比较,海绵和陶粒较适宜作为处理硫化氢、氨和微生物气溶胶的生物滤池填料。  相似文献   

15.
Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppm(v)), methyl ethyl ketone (12 ppm(v)), toluene (29 ppm(v)), ethylbenzene (10 ppm(v)), and p-xylene (10 ppm(v)). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m(-3) hr(-1) and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were, more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

16.
Development and performance of an alternative biofilter system   总被引:3,自引:0,他引:3  
Step tracer tests were carried out on lab-scale biofilters to determine the residence time distributions (RTDs) of gases passing through two types of biofilters: a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow. Results were used to define the flow patterns in the reactors. "Non-ideal flow" indicates that the flow reactors did not behave like either type of ideal reactor: the perfectly stirred reactor [often called a "continuously stirred tank reactor" (CSTR)] or the plug-flow reactor. The horizontal biofilter with back-mixing was able to accommodate a shorter residence time without the usual requirement of greater biofilter surface area for increased biofiltration efficiency. Experimental results indicated that the first bed of the modified biofilter behaved like two CSTRs in series, while the second bed may be represented by two or three CSTRs in series. Because of the flow baffles used in the horizontal biofilter system, its performance was more similar to completely mixed systems, and hence, it could not be modeled as a plug-flow reactor. For the standard biofilter, the number of CSTRs was found to be between 2 and 9 depending on the airflow rate. In terms of NH3 removal efficiency and elimination capacity, the standard biofilter was not as good as the modified system; moreover, the second bed of the modified biofilter exhibited greater removal efficiency than the first bed. The elimination rate increased as biofilter load increased. An opposite trend was exhibited with respect to removal efficiency.  相似文献   

17.
Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

18.
Long-term operation of biofilters for biological removal of ammonia   总被引:6,自引:0,他引:6  
Chen YX  Yin J  Wang KX 《Chemosphere》2005,58(8):1023-1030
Biological removal of ammonia was investigated using two types of packing materials, compost and sludge in laboratory-scale biofilters (8l reactor volume). The aim of this study is to investigate the potential of unit systems packed with these supports in terms of ammonia emissions treatment. Experimental tests and measurements included analysis of removal efficiency, metabolic products, and results of long-term operation. The inlet concentration of ammonia applied was 20-200 mg m-3. The ammonia loading rates of 24.9-566 g NH3 m-3 d-1 to compost biofilter (BF3) and 24.9-472 g NH3 m-3 d-1 to sludge biofilter (BF4) were applied for 210 days, respectively. Removal efficiencies of the compost and sludge biofilters were in the range of 97-99% and 95-99%, respectively when the inlet concentration of ammonia was below 110 mg m-3, and the maximum elimination capacities were 288 and 243 g NH3m-3d-1, respectively. However, removal efficiency and elimination capacity of both biofilters significantly decreased as the inlet concentration increased to above 110 mg m-3. By using kinetic analysis, the maximum removal rate of ammonia, Vm, and the saturation constant, Ks, were determined for both packing materials and the value of Vm for compost was found to be larger. Periodic analysis of the biofilter packing materials showed the accumulation of the nitrification product NO3- in the operation. During the experiment, the pressure drops measured were very low. The use of both packing materials requires neither nutritive aqueous solution nor buffer solution.  相似文献   

19.
This study was conducted to evaluate the effects of gas inlet concentration and velocity on the biofiltration of gasoline vapor. Gasoline vapor was treated using a compost biofilter operated in an upflow mode for about 3 months. The inlet concentration of gasoline total petroleum hydrocarbon (TPH) ranged from about 300 to 7000 mgm(-3) and gas was injected at velocities of 6 and 15 mh(-1) (empty bed residence time (EBRT)=10 and 4 min, respectively). The maximum elimination capacities of TPH at 6 and 15 mh(-1) found in this research were over 24 and 19 gm(-3) of filling material h(-1), respectively. TPH removal data was fit using a first-order kinetic relationship. In the low concentration range of 300-3000 mg m(-3), the first-order kinetic constants varied between about 0.10 and 0.29 min(-1) regardless of gas velocities. At TPH concentrations greater than 3000 mgm(-3), the first-order kinetic constants were about 0.09 and 0.07 min(-1) at gas velocities of 6 mh(-1) and 15 mh(-1), respectively. To evaluate microbial dynamics, dehydrogenase activity, CO2 generation and microbial species diversity were analyzed. Dehydrogenase activity could be used as an indicator of microbial activity. TPH removal corresponded well with CO2 evolution. The average CO2 recovery efficiency for the entire biofilter ranged between 60% and 70%. When the gas velocity was 6 mh(-1), most of the microbial activity and TPH removal occurred in the first quarter of the biofilter. However, when the gas velocity was 15 mh(-1), the entire column contributed to removal. Spatial and temporal variations in the biofilter microbial population were also observed. Nearly 60% of the colonies isolated from the compost media prior to biofiltration were Bacillus. After 90 days of biofiltration, the predominant species in the lower portion (0-50 cm) of the filter were Rhodococcus, while Pseudomonas and Acinetobacter dominated the upper portion (75-100 cm).  相似文献   

20.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   