共查询到18条相似文献,搜索用时 109 毫秒
1.
生物滤池处理城市污水工艺中恶臭和微生物气溶胶的填料选择简 总被引:1,自引:0,他引:1
采用实验室规模的生物滤池对含硫化氢、氨和微生物气溶胶的气体进行处理,并对海绵、陶粒、堆肥和空心塑料小球4种物质作为反应器填料的性能进行比较。结果表明,不同填料生物滤池对硫化氢、氨和微生物气溶胶的去除效率明显不同,去除效率从高到低的顺序依次为海绵、陶粒、堆肥和空心塑料小球生物滤池。海绵和陶粒生物滤池出气异养细菌和真菌主要以小粒径粒子为主。在同样的进气和运行条件下,堆肥填料层的压力降最大,其次是陶粒和空心塑料小球填料层,海绵填料层的压力降最小。对4种填料的性能进行综合比较,海绵和陶粒较适宜作为处理硫化氢、氨和微生物气溶胶的生物滤池填料。 相似文献
2.
生物滴滤塔处理有机废气的填料选择研究 总被引:1,自引:0,他引:1
以含低浓度乙酸、正己烷和苯乙烯的混合有机气体模拟实际有机废气,采用实验室规模的生物滴滤塔处理有机废气,并比较了海绵、珊瑚石、陶粒和空心塑料小球4种填料的性能。结果表明:(1)生物滴滤塔启动时间最短的为海绵生物滴滤塔(约20d),其次为陶粒生物滴滤塔(约25d),启动时间较长的为珊瑚石生物滴滤塔(约35d)和空心塑料小球生物滴滤塔(约40d)。(2)在稳定运行期,不同填料生物滴滤塔对水溶性和极性较强的乙酸的去除率差异尤为明显,对正己烷和苯乙烯的去除率差异相对较小。(3)4种填料生物滴滤塔中的异养细菌数量依次为海绵>陶粒>珊瑚石>空心塑料小球。运行80d时,海绵、陶粒、珊瑚石和空心塑料小球生物滴滤塔中的异养细菌数量分别达5.9×108、4.8×108、3.6×108、3.0×108 cfu/g(以单位质量干填料计)。(4)在相同的进气流速下,4种填料生物滴滤塔的填料层压力降依次为珊瑚石>陶粒>空心塑料小球>海绵。(5)海绵和陶粒较适宜作为生物滴滤塔的填料。 相似文献
3.
城市污水处理厂除臭生物滤池运行效果及影响因素研究 总被引:1,自引:0,他引:1
对山东某城市污水处理厂散发的恶臭气体进行除臭研究,考察了除臭生物滤池的运行效果、工艺影响因素和除臭生物滤池内微生物相特点。结果表明:(1)在进气量为828 m3/h、气体停留时间为30 s、硫化氢和氨进气质量浓度分别为0.5~28.4、0.9~34.3 mg/m3的条件下,稳定运行时,大部分时间硫化氢和氨去除率分别达98%和80%以上,而且除臭生物滤池对于进气负荷具有较强的抗冲击能力。(2)当填料含湿量为43.6%~63.4%时,硫化氢去除率在90%以上;氨去除受填料含湿量的影响较大,填料含湿量越高越利于氨的去除。(3)在处理低浓度含硫化氢和氨的恶臭气体时,生物除臭工程可以在低填料pH(3.0左右)下长期运行,并保持较高的恶臭气体去除率。(4)运行第60天后,当温度为10℃以上时,硫化氢和氨去除率几乎不受影响;第169天后,当温度降至10℃以下时,硫化氢和氨去除率均有一定程度的下降,最低分别为94.6%和79.8%。(5)除臭生物滤池稳定运行时,优势硫氧化菌主要为嗜酸性硫细菌。 相似文献
4.
对核桃壳-陶粒填料曝气生物滤池(BAF)的挂膜启动和处理效果进行了研究,同时考察不同的水力负荷、气水比、填料层高度对污染物去除效果的影响。结果表明:微生物在核桃壳-陶粒填料上成功挂膜仅需21d,运行稳定后核桃壳-陶粒填料BAF的COD、氨氮去除率分别稳定在92.0%、88.3%左右;在水力负荷为0.06~0.08m3/(m2·h)、气水比为9∶1(体积比)的条件下,核桃壳-陶粒填料BAF处理效果较好且较稳定,氨氮和COD去除率可达70%以上;填料层0~15cm段为核桃壳-陶粒填料BAF去除COD的高效段,15~30cm段为去除氨氮的高效段。 相似文献
5.
根据腐殖填料生物滤池及石英砂普通生物滤池的氨氮去除效率、表面水力负荷及微生物量差异,比较两者氨氮降解速率及比降解速率,对腐殖填料生物滤池的氨氮降解特征进行分析。结果表明,在相同运行方式及外界环境下,腐殖填料滤池表面水力负荷数倍于石英砂普通生物滤池;腐殖填料生物滤池单位体积平均氨氮降解速率高达31.5 g NH4+-N/(m3.d),是石英砂普通生物滤池的5.4倍;腐殖填料生物滤池氨氮比降解速率为4.1×10-2μg NH4+-N/(g微生物碳.d),约为石英砂普通生物滤池的4倍。腐殖填料生物滤池能负载较高的生物量,抗堵塞性能较强,系统内特异微生物对氨氮降解能力较高,是一种优良的降解氨氮的生物滤池。 相似文献
6.
7.
几种腐殖填料生物滤池COD去除效能比较研究 总被引:1,自引:0,他引:1
分别采用腐殖垃圾、泥炭、煤炭等腐殖填料及河沙构筑生物滤池,处理模拟废水,比较研究其COD去除效能及降解特征,为工艺填料改性提供理论依据。几种填料的扫描电镜分析图显示腐殖垃圾及泥炭以团聚体三维空间结构为主;煤炭与河沙表面粗糙程度较小,且主要由颗粒状物质构成。稀释平板涂布法分离出各生物滤池中发挥主要作用的微生物共3种,各系统菌落数量有差异,但种类相同。3种腐殖填料生物滤池在进水有机物浓度为500 mg/L及1000 mg/L时均有较理想的有机物去除效率。3种腐殖填料生物滤池中泥炭构筑的腐殖填料生物滤池有机物比降解速率最小,因而微生物比增长速率最小,微生物增长和自身氧化最易趋向于动态平衡,对应的饱和水力渗透系数最大,滤池最不易发生堵塞,最有利于腐殖填料生物滤池长期稳定运行,证明泥炭是一种优良的生物介质。 相似文献
8.
9.
10.
复合式生物除臭反应器处理城市污水处理厂恶臭气体 总被引:4,自引:0,他引:4
采用复合式生物除臭反应器处理北京某城市污水处理厂污泥浓缩池和脱水间散发的恶臭气体,研究了反应器对恶臭气体的净化效果和微生物悬浮生长区与附着生长区内的生物特性及对恶臭污染物的去除能力。该污水处理厂的恶臭气体中主要发臭物质为硫化氢和氨,除臭反应器的运行结果表明,在设备稳定运行期间,进气中硫化氢和氨的浓度分别为0.21~22.61 mg/m3和0.1~0.5 mg/m3,而出气中硫化氢浓度在0~0.06 mg/m3,氨浓度为0~0.02 mg/m3。对反应器内部测试表明,微生物悬浮生长区和附着生长区对硫化氢和氨都有一定的去除,但去除机理不同。硫化氢主要被附着生长区的嗜酸性硫细菌生物氧化,少量硫化氢在悬浮区溶于水被中性硫细菌氧化;氨主要在悬浮区靠生物硝化作用去除,少部分氨在附着区被去除,且多因化学中和作用转移到填料所含的水中。 相似文献
11.
Chung YC Lin YY Tseng CP 《Journal of the Air & Waste Management Association (1995)》2004,54(4):450-458
Simultaneous removal of hydrogen sulfide (H2S) and ammonia (NH3) gases from gaseous streams was studied in a biofilter packed with granule activated carbon. Extensive studies, including the effects of carbon (C) source on the growth of inoculated microorganisms and gas removal efficiency, product analysis, bioaerosol emission, pressure drop, and cost evaluation, were conducted. The results indicated that molasses was a potential C source for inoculated cell growth that resulted in removal efficiencies of 99.5% for H2S and 99.2% for NH3. Microbial community observation by scanning electron microscopy indicated that granule activated carbon was an excellent support for microorganism attachment for long-term waste gas treatment. No disintegration or breakdown of biofilm was found when the system was operated for 140 days. The low bioaerosol concentration emitted from the biofilter showed that the system effectively avoided the environmental risk of bioaerosol emission. Also, the system is suitable to apply in the field because of its low pressure drop and treatment cost. Because NH3 gas was mainly converted to organic nitrogen, and H2S gas was converted to elemental sulfur, no acidification or alkalinity phenomena were found because of the metabolite products. Thus, the results of this study demonstrate that the biofilter is a feasible bioreactor in the removal of waste gases. 相似文献
12.
Biological removal of ammonia was investigated using two types of packing materials, compost and sludge in laboratory-scale biofilters (8l reactor volume). The aim of this study is to investigate the potential of unit systems packed with these supports in terms of ammonia emissions treatment. Experimental tests and measurements included analysis of removal efficiency, metabolic products, and results of long-term operation. The inlet concentration of ammonia applied was 20-200 mg m-3. The ammonia loading rates of 24.9-566 g NH3 m-3 d-1 to compost biofilter (BF3) and 24.9-472 g NH3 m-3 d-1 to sludge biofilter (BF4) were applied for 210 days, respectively. Removal efficiencies of the compost and sludge biofilters were in the range of 97-99% and 95-99%, respectively when the inlet concentration of ammonia was below 110 mg m-3, and the maximum elimination capacities were 288 and 243 g NH3m-3d-1, respectively. However, removal efficiency and elimination capacity of both biofilters significantly decreased as the inlet concentration increased to above 110 mg m-3. By using kinetic analysis, the maximum removal rate of ammonia, Vm, and the saturation constant, Ks, were determined for both packing materials and the value of Vm for compost was found to be larger. Periodic analysis of the biofilter packing materials showed the accumulation of the nitrification product NO3- in the operation. During the experiment, the pressure drops measured were very low. The use of both packing materials requires neither nutritive aqueous solution nor buffer solution. 相似文献
13.
Ying-Chien Chung Yu-Yen Lin 《Journal of the Air & Waste Management Association (1995)》2013,63(4):450-458
Abstract Simultaneous removal of hydrogen sulfide (H2S) and am- gases. monia (NH3) gases from gaseous streams was studied in a biofilter packed with granule activated carbon. Extensive studies, including the effects of carbon (C) source on the growth of inoculated microorganisms and gas removal efficiency, product analysis, bioaerosol emission, pressure drop, and cost evaluation, were conducted. The results indicated that molasses was a potential C source for inoculated cell growth that resulted in removal efficiencies of 99.5% for H2S and 99.2% for NH3. Microbial community observation by scanning electron microscopy indicated that granule activated carbon was an excellent support for microorganism attachment for long-term waste gas treatment. No disintegration or breakdown of biofilm was found when the system was operated for 140 days. The low bioaerosol concentration emitted from the biofilter showed that the system effectively avoided the environmental risk of bioaerosol emission. Also, the system is suitable to apply in the field because of its low pressure drop and treatment cost. Because NH3 gas was mainly converted to organic nitrogen, and H2S gas was converted to elemental sulfur, no acidification or alkalinity phenomena were found because of the metabolite products. Thus, the results of this study demonstrate that the biofilter is a feasible bioreactor in the removal of waste gases. 相似文献
14.
Kalingan AE Liao CM Chen JW Chen SC 《Journal of environmental science and health. Part. B》2004,39(1):185-198
The purpose of this research was to neutralize livestock-generated ammonia by using biofilters packed with inexpensive inorganic and organic packing material combined with multicultural microbial load at typical ambient temperatures. Peat and inorganic supporting materials were used as biofiltration matrix packed in a perfusion column through which gas was transfused. Results show the ammonia removal significantly fell in between 99 and 100% when ammonia concentration of 200 ppmv was used at different gas flow rates ranged from 0.030 to 0.060 m3 h(-1) at a fluctuating room temperature of 27.5 +/- 4.5 C (Mean +/- SD). Under these conditions, the emission concentration of ammonia that is liberated after biofiltration is less than 1 ppmv (0.707 mg m(-3)) over the period of our study, suggesting the usage of low-cost biofiltration systems for long-term function is effective at wider ranges of temperature fluctuations. The maximum (100%) ammonia removal efficiency was obtained in this biofilter was having an elimination capacity of 2.217 g m(-3) h(-1). This biofilter had high nitrification efficiencies and hence controlled ammonia levels with the reduced backpressure. The response of this biofilter to shut down and start up operation showed that the biofilm has a superior stability. 相似文献
15.
《Journal of the Air & Waste Management Association (1995)》2013,63(12):1458-1467
Abstract Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media. 相似文献
16.
Sakuma T Hattori T Deshusses MA 《Journal of the Air & Waste Management Association (1995)》2006,56(11):1567-1575
Four different biofilter packing materials (two porous ceramics, perlite, and open pore polyurethane foam) were compared for the removal of toluene vapors. The focus was on evaluating performance at relatively short gas retention time (13.5 and 27 sec). The reactors were initially operated as biotrickling filters with continuous feeding and trickling of a nutrient solution. After significant plugging of the biotrickling filter beds with biomass was observed, the operation mode was switched to biofiltration with only periodic supply of mineral nutrients. This resulted in stable conditions, which allowed detailed investigations over > 6 months. The reactor packed with cattle bone Porcelite (CBP), a ceramic material containing some macronutrients and micronutrients, exhibited the highest performance. The critical load (i.e., load at which 95% removal occurred) was 29 g m(-3) hr(-1) at a gas retention time of 13.5 sec and 66 g m(-3) hr(-1) at a gas retention time of 27 sec. After the long-term experiment, the packing materials were taken from the reactors and examined. The reactors were divided into three sections, top, middle, and bottom, to determine whether spatial differentiation of biomass occurred. The assays included a double-staining technique to count total and live microorganisms and determination of moisture, protein, and dry weight contents. Microbial community analysis was also conducted by denaturing gradient gel electrophoresis. The results showed that most reactors had a significant fraction of inactive biomass. Comparatively, the CBP biofilter held significantly higher densities of active biomass, which may be the reason for the higher toluene removal performance. The analyses suggest that favorable material properties and the nutrients slowly released by the CBP provided better environmental conditions for the process culture. 相似文献
17.
Choi JH Kim YH Joo DJ Choi SJ Ha TW Lee DH Park IH Jeong YS 《Journal of the Air & Waste Management Association (1995)》2003,53(1):92-101
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system. 相似文献
18.
Biological treatment process of air loaded with an ammonia and hydrogen sulfide mixture 总被引:21,自引:0,他引:21
The physico-chemical characteristics of granulated sludge lead us to develop its use as a packing material in air biofiltration. Then, the aim of this study is to investigate the potential of unit systems packed with this support in terms of ammonia and hydrogen sulfide emissions treatment. Two laboratory scale pilot biofilters were used. A volumetric load of 680 g H2S m(-3) empty bed day(-1) and 85 g NH3 m(-3) empty bed day(-1) was applied for eight weeks to a unit called BGSn (column packed with granulated sludge and mainly supplied with hydrogen sulfide); a volumetric load of 170 g H2S m(-3) empty bed day(-1) and 340 g NH3 m(-3) empty bed day(-1) was applied for eight weeks to the other called BGNs (column packed with granulated sludge and mainly supplied with ammonia). Ammonia and hydrogen sulfide elimination occur in the biofilters simultaneously. The hydrogen sulphide and ammonia removal efficiencies reached are very high: 100% and 80% for BGSn; 100% and 80% for BGNs respectively. Hydrogen sulfide is oxidized into sulphate and sulfur. The ammonia oxidation products are nitrite and nitrate. The nitrogen error mass balance is high for BGSn (60%) and BGNs (36%). This result could be explained by the denitrification process which would have occurred in anaerobic zones. High percentages of ammonia or hydrogen sulfide are oxidized on the first half of the column. The oxidation of high amounts of hydrogen sulfide would involve some environmental stress on nitrifying bacterial growth and activity. 相似文献