首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 331 毫秒
1.
Simplified algorithms are presented for estimating the cost of controlling sulfur dioxide (SO2) emissions from existing coal-fired power plants on a state-by-state basis. Results are obtained using the detailed Utility Control Strategy Model (UCSM) to calculate the Impacts of emission reductions ranging from approximately 30 percent to 90 percent of projected 1995 emissions for 18 different scenarios and 36 states. Scenarios include the use of two dry SO2 removal technologies (lime spray dryers and LIMB) as potential options for power plant retrofit, in addition to currently available emission control options including coal switching, coal cleaning and wet flue gas desulfurization (FGD). Technical assumptions relating to FGD system performance and the upgrading of existing cold-side electrostatic precipitators (ESP) for reduced sulfur levels are also analyzed, along with the effects of interest rates, coal prices, coal choice restrictions, plant lifetime, and plant operating levels. Results are summarized in the form of a 3-term polynomial equation for each state, giving total annualized SO2 control cost as a function of the total SO2 emissions reduction for each scenario. Excellent statistical fits to UCSM results are obtained for these generalized equations.  相似文献   

2.
Abstract

Supply curves were prepared for coal-fired power plants in the contiguous United States switching to Wyoming's Powder River Basin (PRB) low-sulfur coal. Up to 625 plants, representing ~44% of the nameplate capacity of all coal-fired plants, could switch. If all switched, more than $8.8 billion additional capital would be required and the cost of electricity would increase by up to $5.9 billion per year, depending on levels of plant derating. Coal switching would result in sulfur dioxide (SO2) emissions reduction of 4.5 million t/yr. Increase in cost of electricity would be in the range of 0.31-0.73 cents per kilowatt-hour. Average cost of S emissions reduction could be as high as $1298 per t of SO2. Up to 367 plants, or 59% of selected plants with 32% of 44% nameplate capacity, could have marginal cost in excess of $1000 per t of SO2. Up to 73 plants would appear to benefit from both a lowering of the annual cost and a lowering of SO2 emissions by switching to the PRB coal.  相似文献   

3.
A computerized simulation model has been developed to compute energy requirements of a limestone slurry flue gas desulfurization (FGD) system as a function of FGD system design parameters, power plant characteristics, coal properties, and sulfur dioxide emission regulation. Results are illustrated for a "base case" plant of 500 MW, burning 3.5% sulfur coal, meeting the federal new source performance standard of 1.2 lb SO2/106 Btu. The flue gas is cleaned by an electrostatic precipitator followed by a limestone FGD system with a TCA scrubbing vessel and an optimized in-line steam reheater. The total FGD system energy requirement for this case was found to be 3.4% of the total energy input to the boiler. Sensitivity analyses were then performed in which the nominal values of ten system parameters were individually varied. This caused the total FGD system energy requirement to vary between 2.5 % and 6.1 % of the gross plant output for the range of parameters tested. The most sensitive parameters were found to be scrubbing slurry pH, which affects pumping requirements, and stack gas exit temperature, which affects reheat requirements. In all cases, FGD energy requirements were minimized when the SO2 emission standard was met by partially bypassing the scrubber. In light of the recent Clean Air Act Amendments this option may not be feasible in the future.  相似文献   

4.
ABSTRACT

Coal-fired electricity-generating plants may use SO2 scrubbers to meet the requirements of Phase II of the Acid Rain SO2 Reduction Program. Additionally, the use of scrubbers can result in reduction of Hg and other emissions from combustion sources. It is timely, therefore, to examine the current status of SO2 scrubbing technologies. This paper presents a comprehensive review of the state of the art in flue gas desulfurization (FGD) technologies for coal-fired boilers.

Data on worldwide FGD applications reveal that wet FGD technologies, and specifically wet limestone FGD, have been predominantly selected over other FGD technologies. However, lime spray drying (LSD) is being used at the majority of the plants employing dry FGD technologies. Additional review of the U.S. FGD technology applications that began operation in 1991 through 1995 reveals that FGD processes of choice recently in the United States have been wet limestone FGD, magnesium-enhanced lime (MEL), and LSD. Further, of the wet limestone processes, limestone forced oxidation (LSFO) has been used most often in recent applications.

The SO2 removal performance of scrubbers has been reviewed. Data reflect that most wet limestone and LSD installations appear to be capable of ~90% SO2 removal. Advanced, state-of-the-art wet scrubbers can provide SO2 removal in excess of 95%.

Costs associated with state-of-the-art applications of LSFO, MEL, and LSD technologies have been analyzed with appropriate cost models. Analyses indicate that the capital cost of an LSD system is lower than those of same capacity LSFO and MEL systems, reflective of the relatively less complex hardware used in LSD. Analyses also reflect that, based on total annualized cost and SO2 removal requirements: (1) plants up to ~250 MWe in size and firing low- to medium-sulfur coals (i.e., coals with a sulfur content of 2% or lower) may use LSD; and (2) plants larger than 250 MWe and firing medium- to high-sulfur coals (i.e., coals with a sulfur content of 2% or higher) may use either LSFO or MEL.  相似文献   

5.
Abstract

Comprehensive surveys conducted at 5-yr intervals were used to estimate sulfur dioxide (SO2) and nitrogen oxides (NOx) emissions from U.S. pulp and paper mills for 1980, 1985, 1990, 1995, 2000, and 2005. Over the 25-yr period, paper production increased by 50%, whereas total SO2 emissions declined by 60% to 340,000 short tons (t) and total NOx emissions decreased approximately 15% to 230,000 t. The downward emission trends resulted from a combination of factors, including reductions in oil and coal use, steadily declining fuel sulfur content, lower pulp and paper production in recent years, increased use of flue gas desulfurization systems on boilers, growing use of combustion modifications and add-on control systems to reduce boiler and gas turbine NOx emissions, and improvements in kraft recovery furnace operations.  相似文献   

6.
Estimates of 1973–1982 annual SO2 emissions from electric utility plants are presented in this paper. Results are based on analyses of plant level data collected by the U.S. Department of Energy on consumption and quality of fuels burned. Emissions are estimated from known information about fuel consumption, sulfur content, ash content, and control equipment. Results show that electric utility emissions decreased 16% from 1973 to 1982 and that these reductions were due to the use of lower sulfur coals and to the operation of flue gas desulfurization equipment.  相似文献   

7.
Abstract

Emissions of sulfur trioxide (SO3) are a key component of plume opacity and acid deposition. Consequently, these emissions need to be low enough to not cause opacity violations and acid deposition. Generally, a small fraction of sulfur (S) in coal is converted to SO3 in coal-fired combustion devices such as electric utility boilers. The emissions of SO3 from such a boiler depend on coal S content, combustion conditions, flue gas characteristics, and air pollution devices being used. It is well known that the catalyst used in the selective catalytic reduction (SCR) technology for nitrogen oxides control oxidizes a small fraction of sulfur dioxide in the flue gas to SO3. The extent of this oxidation depends on the catalyst formulation and SCR operating conditions. Gas-phase SO3 and sulfuric acid, on being quenched in plant equipment (e.g., air preheater and wet scrubber), result in fine acidic mist, which can cause increased plume opacity and undesirable emissions. Recently, such effects have been observed at plants firing high-S coal and equipped with SCR systems and wet scrubbers. This paper investigates the factors that affect acidic mist production in coal-fired electric utility boilers and discusses approaches for mitigating emission of this mist.  相似文献   

8.
The growing awareness of ecological issues in Europe, reinforced by the public debate surrounding acid rain, has led to the enactment of laws and regulations in West Germany relating to emissions from large coal fired combustors.

Flue gas desulfurization (FGD) units have been compulsory for new coal fired power plants in West Germany for about 12 years. The new legislation enacted in 1983, to be met by the middle of 1988, applies not only to new plants but, unlike in the United States, also to. existing power plants (>30MW).

The law currently specifies a residual SO2 emission level of 400 mg/Nm3 (0.311b MM/BTU) for large power plants (>100 MW), but a level of 200 mg/Nm3 (0.15 lb MM/BTU) is already under discussion in some cases. The legally binding emission standards stipulate that none of the daily averages, calculated on the basis of half hour averages may exceed the concentration allowed. SO2 removal efficiencies of 90 percent to 95 percent are normally provided. Since 1983, more than 35,000 MW of retrofit FGD units have been installed in Germany to meet this SO2 standard.

The regulations also do not allow for the ponding of calcium sulfite scrubber sludge, but stipulate the production of gypsum from limestone slurry processes. Additionally the regulations require flue gases to have a minimum temperature in the stack of 72° C (162°F) after desulfurization. Treated flue gases do not have to be reheated if discharged via a cooling tower.  相似文献   

9.
A computer program has been written to determine the cost of building and operating wet scrubbers on individual coal fired utilities in the states where emissions are likely to affect the acid rain problem in the eastern United States. The program differs from many other estimates since it calculates the cost for each of 831 individual sites. The capital costs for installing scrubbers on the top fifty sulfur oxide emitting plants will be about $20 billion. This will result in an increase in the cost of electricity on an average of 0.88 cents/kWh and a reduction of sulfur oxide emissions from 1980 of 7,100,000 tons per year. An additional reduction of at least 1,000,000 tons per year can be obtained by requiring all plants burning oil to burn low sulfur oil. These figures assume utilities will use least emissions dispatching and will use local coals containing at least 3.5 percent sulfur. The use of local coals should result in a further saving of at least 0.2 cents/kWh. This should make available a large supply of low sulfur coal which could reduce emissions of sulfur oxides by up to 1,000,000 tons per year. The SO2 reductions will be continued for at least the next thirteen years and have a very significant effect through the year 2010.  相似文献   

10.
The concentrations of fine particles and selected gas pollutants in the flue gas entering the stack were measured under several common operation modes in an operating coal power plant producing electricity. Particle size distributions in a diameter range from 10 nm to 20 μm were measured by a scanning mobility particle sizer (SMPS), and the flue gas temperature and concentrations of CO2 and SO2 were monitored by a continuous emission monitoring system (CEMS). During the test campaign, five plant operating modes were studied: soot blowing, bypass of flue-gas desulfurization (FGD), reheat burner operating at 0% (turned off), 27%, and 42% (normal condition) of its full capacity. For wet and dry aerosols, the measured mode sizes were both around 40 nm, but remarkable differences were observed in the number concentrations (#/cm3, count per square centimeter). A prototype photoionizer enhanced electrostatic precipitator (ESP) showed improved removal efficiency of wet particles at voltages above +11.0 kV. Soot blowing and FGD bypass both increased the total particle number concentration in the flue gas. The temperature was slightly increased by the FGD bypass mode and varied significantly as the rating of reheat burner changed. The variations of CO2 and SO2 emissions showed correlations with the trend of total particle number concentration possibly due to the transitions between gas and particle phases. The results are useful in developing coal-fired power plant operation strategies to control fine particle emissions and developing amine-based CO2 capture technologies without operating and environmental concerns associated with volatile amine emissions.

Implications: The measurement of the fine particle size distributions in the exhaust gas under several common operating conditions of a coal-fired power plant revealed different response relations between aerosol number concentration and the operating condition. A photo-ionizer enhanced ESP was demonstrated to capture fine particles with higher efficiency compared to conventional ESPs, and the removal efficiency increased with the applied voltage. The characteristic information of aerosols and main gaseous pollutants in the exhaust gas is extremely important for developing and deploying CO2 scrubbers, whose amine emissions and operating effectiveness depends greatly on the upstream concentrations of fine particles, SO2, from the power plant.  相似文献   


11.
The Clean Air Act Amendments of the early 1970s required coal burning utilities to reduce their emissions of sulfur dioxide. Lime or limestone based wet systems were employed for flue gas desulfurization (FGD). These systems reduced flue gas temperatures to below acid dew point conditions. Concerned about the prospect of ductwork exposed to a saturated, acid-rich environment, most utilities turned to stack gas reheat (SGR) to increase flue gas temperatures. By 1980, 82 percent of all FGD facilities employed SGR. Today there are about 130 FGD systems of which 101 employ some form of stack gas reheat.  相似文献   

12.
Abstract

This paper analyzes the natural desulfurization process taking place in coal-fired units using Greek lignite. The dry scrubbing capability of Greek lignite appears to be extremely high under special conditions, which can make it possible for the units to operate within the legislative limits of sulfur dioxide (SO2) emissions. According to this study on several lignite-fired power stations in northern Greece, it was found that sulfur oxide emissions depend on coal rank, sulfur content, and calorific value. On the other hand, SO2 emission is inversely proportional to the parameter y CO2max, which is equal to the maximum carbon dioxide (CO2) content by vol ume of dry flue gas under stoichiometric combustion. The desulfurization efficiency is positively correlated to the molar ratio of decomposed calcium carbonate to sulfur and negatively correlated to the free calcium oxide content of fly ash.  相似文献   

13.
Although sulphur emissions (mainly as SO2) have been continuously decreasing over the last 20 years in most western industrialized countries, localized SO2 problems still exist in conjunction with strong local emission, meteorological, and topographical factors. In this study, the effect of supplementary installed flue gas desulphurization (FGD) units at high-capacity power plants on regional air pollution in the Carpathian Basin is investigated. The dispersion and accumulation of the SO2 air pollutant are studied with the regional three-dimensional on-line atmosphere-chemistry model REMOTE. The changes in the SO2 air pollution are investigated by parallel simulations in a case study, where the single modified parameter is the SO2 emission rate. The results show that FGD units significantly reduce the horizontal and the vertical dispersion of the emitted SO2, and its transboundary transport, too. Beside the SO2 removal efficiency, the dispersion and accumulation also depend on the seasonal weather conditions. During winter, the dispersion and accumulation are higher than in other seasons. Due to this phenomenon, higher SO2 removal efficiency is needed to guarantee similar air quality features like in the other seasons.  相似文献   

14.
Encouraged by the successes attained with fly ash control by fabric filters in Pennsylvania Power & Light and Colorado Ute, other utilities are installing, planning, and/or considering baghouses as a practical and economical means for controlling emissions from the burning of low sulfur coals. Where deposits of alkaline reagents (i.e. nahcolite) are available, some power plants are also considering a process for dry scrubbing SO2 from the flue gas. By introducing such reagents with the emission ahead of the fabric collector, both partlculates and SO2 are removed.  相似文献   

15.
Abstract

As a result of the large limestone deposits available in Poland, the low cost of reagent acquisition for the large-scale technological use and relatively well-documented processes of flue gas desulfurization (FGD) technologies based on limestone sorbent slurry, wet scrubbing desulfurization is a method of choice in Poland for flue gas treatment in energy production facilities, including power plants and industrial systems. The efficiency of FGD using the above method depends on several technological and kinetic parameters, particularly on the pH value of the sorbent (i.e., ground limestone suspended in water). Consequently, many studies in Poland and abroad address the impact of various parameters on the pH value of the sorbent suspension, such as the average diameter of sorbent particles (related to the limestone pulverization degree), sorbent quality (in terms of pure calcium carbonate [CaCO3] content of the sorbent material), stoichiometric surfeit of CaCO3 in relation to sulfur dioxide (SO2) absorbed from flue gas circulating in the absorption node, time of absorption slurry retention in the absorber tank, chlorine ion concentration in sorbent slurry, and concentration of dissolved metal salts (Na, K, Mg, Fe, Al, and others). This study discusses the results of laboratory-scale tests conducted to establish the effect of the above parameters on the pH value of limestone slurry circulating in the SO2 absorption node. On the basis of the test results, a correlation equation was postulated to help maintain the desirable pH value at the design phase of the wet FGD process. The postulated equation displays good coincidence between calculated pH values and those obtained using laboratory measurements.  相似文献   

16.
The primary goal of this paper is to reveal the reaction behavior of SO2 in the sinter zone, combustion zone, drying–preheating zone, and over-wet zone during flue gas recirculation (FGR) technique. The results showed that SO2 retention in the sinter zone was associated with free-CaO in the form of CaSO3/CaSO4, and the SO2 adsorption reached a maximum under 900ºC. SO2 in the flue gas came almost from the combustion zone. One reaction behavior was the oxidation of sulfur in the sintering mix when the temperature was between 800 and 1000ºC; the other behavior was the decomposition of sulfite/sulfate when the temperature was over 1000ºC. However, the SO2 adsorption in the sintering bed mainly occurred in the drying–preheating zone, adsorbed by CaCO3, Ca(OH)2, and CaO. When the SO2 adsorption reaction in the drying–preheating zone reached equilibrium, the excess SO2 gas continued to migrate to the over-wet zone and was then absorbed by Ca(OH)2 and H2O. The emission rising point of SO2 moved forward in combustion zone, and the concentration of SO2 emissions significantly increased in the case of flue gas recirculation (FGR) technique.

Implications: Aiming for the reuse of the sensible heat and a reduction in exhaust gas emission, the FGR technique is proposed in the iron ore sintering process. When using the FGR technique, SO2 emission in exhaust gas gets changed. In practice, the application of the FGR technique in a sinter plant should be cooperative with the flue gas desulfurization (FGD) technique. Thus, it is necessary to study the influence of the FGR technique on SO2 emissions because it will directly influence the demand and design of the FGD system.  相似文献   


17.
A study was carried out to investigate the emissions of SO2 and primary sulfate materials (H2SO4 and inorganic particulate matter) from a boiler burning fossil fuel and using a wet-limestone scrubber for SO2 removal. Experiments were designed to assess the scrubbing efficiency for SO2 and sulfate, as well as the potential for scrubber liquor reentrainment. The boiler studied was an 820 MW cyclone-fired unit equipped with a wet, limestone scrubber, consisting of eight two-stage venturi-absorber modules designed to treat a flue gas flow rate of 2,760,000 acfm. The boiler fuel was a low-grade sub-bituminous coal with ash and sulfur contents of 25 and 5%, respectively. Multiple-sampling methods were employed concurrently on the inlet and outlet of a candidate absorber module to measure SO2, total water-soluble sulfate, and free H2SO4. Samples were collected during three field experiments from September 1977 through April 1978. The average SO2 scrubbing efficiency was 76% and was observed to decrease over the 5 day operation/maintenance cycle of the module. The total water-soluble sulfate input to the scrubber amounted to approximately 1% of the total sulfur oxides and was composed of a 5:1 ratio of H2SO4 to particulate sulfate. The total sulfate scrubbing efficiency, averaging about 29%, was invariant with respect to SO2 removal. The sulfate emissions measured in the scrubber exit gas consisted of about 85 % H2SO4 as a fine aerosol. Mass emissions of acid and particulate sulfate were calculated as 1730 Ib/hr and 305 Ib/hr, respectively.  相似文献   

18.
The utility and industrial sectors continue to come under pressure from both national and local regulatory groups to reduce sulfur dioxide emissions. With a trend in the utility industry for life extension, retrofit technologies are likely to play an important role in any SO2 emission reduction strategy. Potential retrofit technologies include, singly and in combination: coal switching or cleaning, wet or dry FGD, conversion to fluidized bed, and dry sorbent injection. The diversity within the utility industry in terms of unit size, unit age, fuel use, financial base, and geographic location dictates the need for a variety of technologies to address SO2 emission control. Dry injection processes involving the injection of dry powders into either the furnace or post-furnace region offer the potential for low capital cost retrofitable technologies. However, compared to wet FGD processes, the dry calcium based processes will likely have lower SO2 removal efficiencies and may pose more plant-wide integration issues that need to be addressed from both an applications and R&D perspective.

This paper provides a critical assessment of dry injection technologies, in two parts. Part 1 focuses on sorbent processes and science. An assessment of the different dry sorbent processes and the effect of process parameters is provided. Emphasis is placed on process limitations and potential avenues to enhance SO2 removal. Part 2 will deal with applications of the technology, addressing cost, scale-up, and integration issues.

Much of the data included in this paper was presented at the 1986 Joint Symposium on Dry SO2 and Simultaneous SO2/NOx Control Technologies, sponsored by the Electric Power Research Institute and the Environmental Protection Agency and held in June 1986. This paper provides both an overview and an evaluation of the technology, based largely on our analysis of the data and interpretations discussed at this symposium.  相似文献   

19.
20.
PM2.5 (particles with aerodynamic diameters less than 2.5 μm) chemical source profiles applicable to speciated emissions inventories and receptor model source apportionment are reported for geological material, motor vehicle exhaust, residential coal (RCC) and wood combustion (RWC), forest fires, geothermal hot springs; and coal-fired power generation units from northwestern Colorado during 1995. Fuels and combustion conditions are similar to those of other communities of the inland western US. Coal-fired power station profiles differed substantially between different units using similar coals, with the major difference being lack of selenium in emissions from the only unit that was equipped with a dry limestone sulfur dioxide (SO2) scrubber. SO2 abundances relative to fine particle mass emissions in power plant emissions were seven to nine times higher than hydrogen sulfide (H2S) abundances from geothermal springs, and one to two orders of magnitude higher than SO2 abundances in RCC emissions, implying that the SO2 abundance is an important marker for primary particle contributions of non-aged coal-fired power station contributions. The sum of organic and elemental carbon ranged from 1% to 10% of fine particle mass in coal-fired power plant emissions, from 5% to 10% in geological material, >50% in forest fire emissions, >60% in RWC emissions, and >95% in RCC and vehicle exhaust emissions. Water-soluble potassium (K+) was most abundant in vegetative burning profiles. K+/K ratios ranged from 0.1 in geological material profiles to 0.9 in vegetative burning emissions, confirming previous observations that soluble potassium is a good marker for vegetative burning.  相似文献   