首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The paper describes criteria for the development of energy systems, with emphasis on “environmental compatibility.” It outlines the main objectives underlying political and regulatory action in the Federal Republic of Germany to ensure this compatibility through the management of environmental risks. The air pollution control policy in the Federal Republic of Germany is presented as a strategy for risk management, focusing on its philosophy and on the recent ordinances concerning air pollution control in large firing (combustion) installations.  相似文献   

2.
In the past, most emphasis in planning for and response to an emergency situation has been placed on selected protective measures in the early phase of an emergency to keep the doses received below levels where severe deterministic health effects can be excluded and/or where the risk of stochastic effects in the population is considered “acceptable”. Less emphasis has been placed on the development of comprehensive protection strategies which include considerations of the consequences of all exposure pathways and all phases, e.g. long-term rehabilitation. In its new publication 103, ICRP proposed a coherent conceptual framework for protection in all types of exposure situations including “emergency exposure situations” and “existing exposure situations”. In the context of developing protection strategies for these exposure situations, the Commission recommends that national authorities set reference levels between, typically, 20 mSv and 100 mSv annual effective dose (emergency exposure situation) and 1 mSv and 20 mSv (existing exposure situation). In order to optimise protection strategies, it is necessary to identify the dominant exposure pathways, the timescales over which the dose will be received, and the effectiveness of available protection options. The characteristics of the development and implementation of such protection strategies is described.  相似文献   

3.
This paper re-proves and generalizes results by Hardin and Sweet on the time to absorption in certain Markov chains by using a theorem on the time to extinction in multitype branching processes. Renaming “absorption” as “death” and “state immediately before absorption” as “cause of death” makes possible an interpretation in terms of competing risks. This is of very limited value, however, due to the rather severe mathematical restrictions on the Markov chains at hand.  相似文献   

4.
Gyttja, the bottom sediment from Perch Lake at Chalk River Nuclear Laboratories, was collected to prepare a low-level, high-organic standard radioactivity reference material. In the natural state it contained about 92% water and when dried the residue was about 50% organic material. The surface layer of this sediment contains small quantities of 60Co, 90Sr, 137Cs and 239Pu. The material was collected from depth using a sludge pump and the radioactivity content adjusted with addition of surface-layer material. It was then dewatered by centrifuge and freeze-dried. The overall exercise was a demonstration of co-operation between the National Bureau of Standards, Washington, D.C., Atomic Energy of Canada Limited, the Ontario Department of Labour, the Environmental Protection Service of Environment Canada, the Department of Agriculture, the Atomic Energy Control Board and two commercial firms, Rush Engineering and Freeze-Dried Foods, Incorporated.  相似文献   

5.
In recent years, scientist have come to realize that contaminated air inside buildings is a major route of human exposure to certain air pollutants. While scientific interest in the problem continues to grow, efforts to measure indoor pollution concentrations, define exposure levels, and estimate health risks remain in their infancy. Within this arena, policymakers must deal with the question of how best to protect public health and safety in the face of incomplete and often contradictory information. In the past, official response to environmental pollution has traditionally taken the form of “control by regulation.” However, creation of a regulatory framework for indoor air quality poses special policy issues that suggest the need to explore alternative modes of intervention. Ambient outdoor air is a public good, in the sense that enjoyment by one individual in no way detracts from use or enjoyment by others. Indoor air, on the other hand, is not a public good, especially in private residences. Costs and benefits of maintaining adequate indoor air quality are internalized within households, suggesting the possibility of a private demand for clean indoor air. Promulgation of indoor air quality standards and other regulations must confront the fact that individuals are already making decisions about their own air quality. Regulations might or might not improve these decisions. Development of effective and reasonable policy requires an appreciation of the scope for private action and consideration of the likelihood that public intervention will foster improved private choices. Among the logical and relatively inexpensive modes of intervention are public information programs, development of simple warning devices, and product testing and labeling.  相似文献   

6.
7.
The opacity and emission performance of two “identical” cold-side precipitators at a power plant utilizing a Western coal source was investigated through an extensive test program. The test program included establishment of outlet emission versus opacity correlations for the two “identical” units, correlation of rapper strategy (frequency and amplitude) with opacity, and correlation of power-off rapping strategy with opacity. Analysis of the test program data demonstrates that the opacity-emission correlations from the two “identical” units can be significantly different. The potential reasons for the differences between the two units are identified and examined in light of the test program data. Strong correlation of opacity with rapping strategy was developed from the test program. Results demonstrate that an automatic power-off rapping technique can significantly enhance precipitator performance on ash from Western coal.  相似文献   

8.
As national trends accelerate towards the reduction of ventilation and infiltration rates in buildings, coupled with an increased use of synthetic chemicals in the indoor environment, a new phenomenon has arisen: the “sick building” syndrome. Traditional approaches to environmental health developed for the outdoor air, or for the industrial occupational setting, are inadequate to deal with this problem. It is argued that a comprehensive approach to the problem of indoor air pollution is necessary to protect public health.  相似文献   

9.
论环境治道变革   总被引:9,自引:0,他引:9  
环境政策型态是指环境政策采取的存在方式。根据我国环境政策的绩效表现和我国市场化改革的前景 ,我国环境政策应从“政府直控型环境政策”转向“社会制衡型环境政策” ,谓之“环境政策转型” ,主要途径是扩大社会环境权益 ,同时适当简化政府环境管理过程。为了进一步激励社会力量的环境保护行动 ,建议设立“环境权益保护日” ,并建立“全国环境保护协会”。  相似文献   

10.
The history of problems dealing with competing risks is briefly outlined, beginning with Daniel Bernoulli's 1760 “Mémoir” on mortality due to smallpox and proceeding through the development of actuarial techniques and methods used in clinical research, reliability theory, population dynamics, and other areas of application. A probabilistic formulation of the theory of competing risks is then presented which appears applicable to all these areas. Within the framework of this theory, some fundamental problems are stated and discussed, such as questions of identifiability, choices of estimation procedures, or techniques for testing hypotheses.  相似文献   

11.
12.
The relationship between the odor strength of total air samples and the odor strengths of the constituents was investigated in three field experiments in an office building and a new preschool. The odor strength was scaled by magnitude estimation according to a master scale principle which results in comparable values for the total and the constituent odors. Between 60 and 120 chemical components were detected by GC/FID in the indoor air samples (N = 66). Most (81%) of the detected components in an air sample were odorous, even though most of them were of the low concentrations. By a method of pattern analysis, chemical as well as odor patterns of indoor air were found to be characteristics of different buildings. From the odor patterns (POG), the “odor print” of the outdoor air associated with the buildings was also recognized in the indoor air. Thus, the “odor print” of an air sample is different from its “chemical print”. A model was found that predicts the overall odor strength of an air sample from the number of FID-detected components most frequently reported to have a strong odor.  相似文献   

13.
The Chambal river, subjected to industrial and sewage pollution, was studied with reference to the benthic fauna. Twenty seven taxa of benthic fauna of four main groups were observed at the stretch of the river: Oligochaeta, Diptera, Mollusca and Insecta (“others”). It was noted that the pollution input zone shows less fauna. The analysis of various physicochemical parameters showed an increase in pollution where domestic and industrial effluent were added. Changes in the benthic community have been explained with the help of the Diversity Index. The species diversity values showed a decrease from the prepollution point to the effluent discharge channel with an increase at the posteffluent point, indicating it to be a recovery zone. The coefficient of correlation was assessed between different physicochemical and different groups of benthic fauna.  相似文献   

14.
Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented. The first two series were dilution experiments; examples of the results are given and discussed. The third series of tests was performed with one person working at a desk in the test room. Above the person;s head, a tracer gas (N2O) was injected into the convection plume, with as low momentum as possible. Starting with zero concentration, a test continued until steady-state conditions were established for the concentration levels in the different parts of the room. The tests included simulation of summer, autumn/spring, and winter daytime conditions. The results indicate a tendency towards lower tracer gas concentrations in the “breathing zone” when the supply air (typical flow rate equivalent to two air changes per hour) is brought into the room at a low level as compared to a high level close to the ceiling. The exhaust air terminal device in all tests was situated high in the “corridor” wall.  相似文献   

15.
16.
长江经济带近年来上升为新一轮的国家战略,然而区域内生态环境面临严峻压力,生态环境保护关系到其有序开发与可持续发展。新环保法的出台与实施为长江经济带开发过程中生态环境保护工作提供了有力的制度保障。从生态环境退化、物种持续减少、环境事故高发等7个方面剖析了我国生态环境问题的趋向,并从明确政府环境责任、解决违法成本低等5个方面对新环保法展开解读,然后基于综合规划、合理布局、严守红线、优化技术、地方立法、依法行政、降低风险、公开信息与共同参与等9个方面对长江经济带的环保执法进行探讨,以期为新时期长江经济带开发法制建设提供参考。  相似文献   

17.
A free-jet scrubber is an innovative gas cleaner in which the primary liquid/gas contacting takes place in the turbulent mixing zone emanating from a jet nozzle. The first such devices, powered by supersonic steam or air ejectors, were exceptionally effective cleaners but were criticized as being high-energy users. A great reduction in the energy consumption of free-jet scrubbers has been accomplished in the last four years, a feat which may seem in contradiction to the “contacting power rule.” An explanation of what is happening in these devices must take into account the effectiveness with which energy and water are utilized. thereby leading one to a somewhat circular definition of “effective contacting power.” The theoretical implication of this analysis is primarily to remind us that there are many paths between two states and some are more energy efficient than others. The practical value is that such analysis generates information which aids in choosing between several design options, a direct benefit of the various free-jet configurations.  相似文献   

18.
A pilot field study was conducted with nine members of the general public to measure carbon monoxide exposure using personal monitors. The principal study objectives were to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. Integrated carbon monoxide exposure was monitored and recorded according to type of activity such as “commuting” or “at work” for approximately 45 days by each subject. All subjects except one were able to handle both the equipment and data recording requirements with no significant problems. Actual data recording responsibilities consumed less than 10 min daily. The data consisted of 355 person-days each over 6-h duration, and weekdays only, from which 8-h average personal exposure levels could be computed. The 9 ppm (μL/L) ambient air quality standard was exceeded on 22 person-days. Elevated carbon monoxide concentrations during the commuting activity were frequently associated with the exceedences.  相似文献   

19.
A complete assessment of the health effects of diesel emissions must take into account the possible chemical transformations (and associated biological impacts) of particulate organic matter (POM) due to reactions with the many gaseous copollutants which have now been unambiguously demonstrated to be present in atmospheres burdened by photochemical air pollution. These copollutants include the “trace” species, nitric (HNO3) and nitrous (HONO) acids, the nitrate radical (NO3), formaldehyde (H2CO) and formic acid (HCOOH), as well as the criteria pollutants, ozone (O3) and nitrogen dioxide (NO2). Techniques for establishing the atmospheric concentrations of the trace pollutants (and their spatial and temporal variations) are briefly described, and we present results of investigations into the reactions of polycyclic aromatic hydrocarbons (PAH) coated on filters and exposed to ambient concentrations of O3 and NO2. Environmental health implications of these results are discussed and include the potential for sampling “artifacts” and their possible effects on the correlation (or lack thereof) between ambient PAH levels and urban lung cancer rates, as well as the problems associated with understanding the appropriate POM “dose” to be employed in animal testing and assessments of impacts on human health.  相似文献   

20.
The very significant impact of European legislation (Directive 91/414/EEC) on the authorization of plant protection products is reviewed herein, which has resulted in withdrawal of 704 active substances (AS) out of 889 assessed so far. The list of currently approved 276 AS includes 194 AS “existing” in the market before 1993 and 82 “new” AS introduced during the last 15 years. Results of toxicity characterization of the approved AS are also summarized, utilizing several well-known databases. Although significant data gaps exist for a rather large part of the approved AS, it is found that 84 AS are positive for at least one health effect (after chronic and/or acute exposure) including carcinogenicity, reproductive and neuro-developmental disorders, as well as endocrine disruption. The toxicity characterization results of this study are compared to those of recent assessments by other organizations (KemI, the Swedish Chemicals Agency, and the Pesticide Safety Directorate of the UK), where interpretation and use is made of AS “cut-off” criteria foreseen in new EU legislation. These studies report a comparatively smaller AS number with positive toxicity characterization. The possibility of some additional AS withdrawal in the near future, combined with the rather small rate of new AS introduction (approx. 5 per year) suggest that the list of approved AS over the next 10–15 years may not change very drastically. Consideration of the above trends is necessary and instructive in evaluating results of existing health impact assessment (HIA) studies, as well as in planning new ones. Due to the very drastic change in the number and type of marketed AS, that took place within the past 8–9 years, it is suggested that new HIA studies (based on epidemiological data after year 2000) should focus on a rather short time frame and, therefore, on appropriate cohort groups, e.g. young children. For the same reason, results of epidemiological studies of the past (involving banned AS) should be carefully interpreted and used with caution.  相似文献   