首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
外循环式UASB反应器处理槟榔废水   总被引:1,自引:0,他引:1  
在中温(35±2℃)条件下,利用外循环式UASB反应器处理中高有机浓度的槟榔加工废水,并着重探讨了水力停留时间(HRT)对厌氧消化的影响。研究表明,当反应器稳定运行,水力停留时间为1 d,进水COD浓度5 000 mg/L左右,容积负荷在2.53-5.25 kg COD/(m3·d)时,COD去除率在38%以上,出水COD〈3 000 mg/L,平均产气率为0.41 m3/kg COD;若水力停留时间延长至4 d,容积负荷为1.26-1.30 kg COD/(m3·d),COD去除率可以达到79%,出水COD〈1 200 mg/L,出水可生化性下降,BOD5/COD平均为0.28,实验取得了良好的处理效果,为利用厌氧技术处理槟榔加工废水提供了设计依据。  相似文献   

2.
Li YM  Gu GW  Zhao JF  Yu HQ  Qiu YL  Peng YZ 《Chemosphere》2003,52(6):997-1005
Coke-plant wastewater was treated by an anaerobic-anoxic-aerobic (A(1)-A(2)-O) biofilm system and an anoxic-aerobic (A/O) biofilm system, respectively. At same or similar levels of hydraulic retention time (HRT), the two systems had almost identical chemical oxygen demand (COD) and NH(3) removals, but a different organic-N removal. Set-up of an acidogenic stage benefited for the removal of organic-N and the A(1)-A(2)-O system was more useful for total nitrogen removal than the A-O system. HRT did not have a substantial effect on the COD and NH(3)-N removal efficiencies, but considerably influenced the organic-N removal and distribution of oxidized nitrogen in the final effluent. The GC/MS analysis demonstrated that some refractory compounds were decomposed at the acidogenic stage and resulted in the production of some intermediates, which were more readily degraded in the subsequent aerobic stage. Hence, the A(1)-A(2)-O system had better effluent quality than the A-O system in terms of effluent composition.  相似文献   

3.
针对神经节苷脂生产废水蛋白质含量高的特点,研究了等电点沉淀或混凝沉降预处理、厌氧好氧生物处理、化学沉淀和类Fenton氧化后处理组合工艺处理神经节苷脂生产废水的技术。结果表明,神经节苷脂生产废水的等电点在pH=2.2左右,通过等电点沉淀可去除30%以上的COD,但等电点时蛋白质的沉淀速度非常慢;用聚合硫酸铁对神经节苷脂生产废水进行混凝预处理的最适工艺条件是:pH=7~7.5,聚合硫酸铁用量=500~750 mg/L。在优化条件下,混凝预处理可以使神经节苷脂生产废水的COD从27 000 mg/L左右降到13 000 mg/L左右。混凝预处理后的神经节苷脂生产废水经48 h厌氧和84 h好氧生物处理,COD值进一步下降到600 mg/L左右。然后向每升生化出水中加入2~3 mmol Fe3+,通过化学沉淀作用除去其中的磷酸盐,过量的Fe3+作为后续类Fenton氧化的催化剂。当H2O2(30%)用量为2~3 mL/L时,最终出水的COD值可以达到国家一级排放标准。  相似文献   

4.
采用两级UASB与好氧组合工艺处理早期城市生活垃圾渗滤液.系统出水按不同比例回流到一级UASB中进行反硝化,同时进行产甲烷反应,有机物在二级UASB中被进一步降解,好氧池完成剩余有机物的去除和氨氮的硝化.启动阶段通过对原渗滤液不同比例的稀释,分5次逐步提高进水浓度,启动结束时完成了对原渗滤液的高效处理.在进水COD浓度从3000 mg/L提高到15000 mg/L,氨氮浓度从250 mg/L提高到1400 mg/L时,最终COD去除率稳定在92%左右,氨氮去除率可达99%以上,一级UASB中反硝化率接近100%,回流比为300%时系统总氮去除率为70%~80%.  相似文献   

5.
In the present study, fate of carbofuran in anaerobic environments and the adverse effects of carbofuran on conventional anaerobic systems were evaluated. Carbofuran degradation studies were carried out in batch reactors with varying carbofuran concentrations of 0 to 270.73 mg/L corresponding to a sludge-loading rate (SLR) of 2.12 x 10(-6) to 3.83 x 10(-3) g of carbofuran/g of volatile suspended solids (VSS)/d. Carbofuran concentration was reduced to undetectable levels at the end of 8 and 13 days in the batch reactors operated with a SLR of 2.12 x 10(-6) and 3.33 x 10(-5) g of carbofuran/g of VSS/d, respectively. Performances of two anaerobic reactors i.e. upflow anaerobic sludge blanket (UASB) and modified UASB (with tube settlers) were evaluated in the presence and absence of carbofuran using synthetic wastewater. In the absence of carbofuran, the soluble chemical oxygen demand (COD) removal efficiency in the conventional UASB reactor at 8 h and 6 h hydraulic retention time (HRT) was nearly 88% and 76%, respectively, whereas in modified UASB reactor it was increased to 90% at 8 h HRT and 78% at 6 h HRT. When 28 mg/L (SLR of 1.19 x 10(-2) g of carbofuran/g of VSS/d) of carbofuran was introduced in the reactors, the COD removal efficiency was reduced to 41% and 44% in conventional and modified UASB reactors respectively. However, the reactor could maintain around 80% COD removal efficiency at a carbofuran concentration of 7.84 mg/L (SLR of 3.64 x 10(-3) g of carbofuran/g of VSS/d). The reactor efficiency was also measured in terms of specific acetoclastic methanogenic activity (SMA). The toxic effect of carbofuran was reversible to a certain extent. Carbofuran removal efficiency in the conventional UASB reactor at carbofuran concentrations of 7, 13 and 28 mg/L were 40 +/- 3%, 27 +/- 3%, and 11 +/- 3%, respectively. In modified UASB reactor, carbofuran removal efficiency was almost uniform at 7 and 13 mg/L but it was reduced nearly by 56% at 28 mg/L. The major metabolite of carbofuran i.e. 3-keto carbofuran was found in all the reactors.  相似文献   

6.
The efficiency of the anaerobic treatment of cheese whey (CW) at mesophilic conditions was investigated. In addition, the applicability of electrochemical oxidation as an advanced post-treatment for the complete removal of chemical oxygen demand (COD) from the anaerobically treated cheese whey was evaluated. The diluted cheese whey, having a pH of 6.5 and a total COD of 6 g/L, was first treated in a 600-L, pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB process, which was operated for 87 days at mesophilic conditions (32?±?2 °C) at a hydraulic retention time (HRT) of 3 days, led to a COD removal efficiency between 66 and 97 %, while the particulate matter of the wastewater was effectively removed by entrapment in the sludge blanket of the reactor. When the anaerobic reactor effluent was post-treated over a boron-doped diamond (BDD) anode at 9 and 18 A and in the presence of NaCl as the supporting electrolyte, complete removal of COD was attained after 3–4 h of reaction. During electrochemical experiments, three groups of organochlorinated compounds, namely trihalomethanes (THMs), haloacetonitriles (HANs), and haloketons (HKs), as well as 1,2-dichloroethane (DCA) and chloropicrin were identified as by-products of the process; these, alongside free chlorine, are thought to increase the matrix ecotoxicity to Artemia salina.  相似文献   

7.
UASB处理硫酸盐有机废水的启动   总被引:1,自引:0,他引:1  
为了考察上流式厌氧污泥床反应器(UASB)处理含硫酸盐有机废水的特性,采用有效容积为10 L的UASB,研究了启动运行过程中COD和SO2-4降解情况、出水VFA和pH值、产气量及颗粒污泥比产甲烷活性(SMA)变化状况。结果表明,接种厌氧颗粒污泥,保持进水COD为1 500 mg/L,SO2-4浓度为100 mg/L,将HRT由24 h缩短至12 h以提高负荷,经历55 d成功启动了UASB反应器;当HRT为12 h,进水COD和SO2-4负荷为3.0 kg/(m3·d)和0.20 kg/(m3·d),COD和SO2-4的去除率分别达到80%和89%,出水VFA为3 mmol/L,产气量达9.5 L/d,颗粒污泥的SMA为86.4 mL/(g VSS·d)。  相似文献   

8.
分别采用水解酸化与好氧(SBR)、厌氧(UASB)与好氧(SBR)工艺对涤纶短纤维废水的生物降解性能进行研究。水解酸化与好氧工艺在进水COD为1 900 mg/L的时候,去除率在80%左右。采用UASB-SBR工艺,进水COD为2700 mg/L时,COD去除率可以达到96%,出水COD〈100 mg/L。实验研究表明,涤纶短纤维废水更适合采用UASB-SBR工艺来处理,并且能够取得较好的效果。  相似文献   

9.
铁炭内电解-厌氧-好氧工艺处理阿维菌素废水的试验研究   总被引:1,自引:0,他引:1  
血清瓶毒性试验表明 ,AVM对厌氧消化产生强烈的抑制作用。AVM废水经铁炭内电解预处理后 ,COD和AVM的去除率分别达到 19.5 %和 6 8.5 % ,可大大降低废水的毒性。预处理出水再经UASB +生物接触氧化反应器进一步处理 ,当生化系统进水COD为 6 0 0 0— 6 5 0 0mg/L时 ,出水COD为 2 5 0— 2 80mg/L ,总COD去除率达到 95 .6 % ,出水达到生物制药行业排放标准  相似文献   

10.
对模拟磷霉素钠制药废水进行Fenton-水解酸化-接触氧化小试处理实验,考察了COD、有机磷的去除效果,并对处理前后的废水进行了GC-MS分析。结果显示,增加了Fenton预处理后磷霉素钠制药废水的COD和有机磷分别降低到100和2 mg/L,去除率均可达87%以上,出水COD满足化学制药行业污染物排放标准(GB 21904-2008);Fenton过程对制药厂废水中的复杂有机物去除效果明显,GC-MS结果表明,出水中基本检测不到复杂有机物。与制药厂采用的水解酸化-接触氧化处理效果相比,增加Fenton预处理可以提高废水的可生化性和系统的处理效率。  相似文献   

11.
BACKGROUND: Dye wastewater is one of the main pollution sources of water bodies in China. Conventional biological processes are relatively ineffective for color removal, the development of alternative treatment methods will become important. Our subjective was that of introducing a new biotreatment technology which combined a facultative biofilm reactor (FBR) with an aerobic reactor (AR) to treat a dye wastewater. The efficiencies of color and chemical oxygen demand (COD) removal and the mechanism of dye degradation were investigated. METHODS: The anthraquinone acid dye (acid blue BRLL) concentration, organic loading rate (OLR) and hydraulic retention time (HRT) were varied in the experiments to evaluate the treatment efficiency and process stability. The biodegradation products were detected by infrared (IR) and high performance liquid chromatography and mass spectrometry (HPLC-MS). RESULTS AND DISCUSSION: The results demonstrated that the facultative biofilm process was more effective for decolorization than the anaerobic stage of an anaerobic-aerobic process. Most color removal occurred in the facultative reaction (maximum to 88.5%) and the BOD (biochemical oxygen demand): COD of the FBR effluent increased by 82.2%, thus improving the biodegradability of dyes for further aerobic treatment. The dye concentration, OLR and HRT will be the factors affecting decolorization. Color removal efficiency falls as the influent dye concentration increases, but rises with increased HRT. The infrared and HPLC-MS analyses of the effluents of FBR and AR reveal that the dye parent compound was degraded in each reactor during the process. CONCLUSION: The Facultative-aerobic (F-A) system can effectively remove both color and COD from the dye wastewater. The FBR played an essential role in the process. The average overall color and COD in the system were removed by more than 93.9% and 97.1%, respectively, at an OLR of 1.1 kg COD m(-3) d(-1) and at the HRT of 18-20 hours in the FBR and 4-5 hours in the AR. The color removal mechanism in each reactor was not only a sort of biosorption on the floc materials, but even more an effect of biodegradation, especially in the facultative process. Recommendation and Outlook. In applying the F-A system to treat a dye wastewater, the control of facultative processes and the set up of appropriate operation conditions appear to be critical factors. Also, it is suggested a moderate COD loading rate and about a 24-hour HRT will favor the F-A system.  相似文献   

12.
在UASB反应器中接种好氧污泥培养厌氧颗粒污泥进行启动,研究不同HRT对老龄(13年)垃圾渗滤液对处理效果的影响情况。通过保持进水COD浓度不变、逐步缩短HRT从而提高容积负荷到40 g COD/(L.d)的方法,可以培育出直径为1~3 mm颗粒污泥,最终产气量稳定在100 L/d,甲烷含量在60%~70%之间,COD去除率保持在90%左右,污泥层最底部MLSS为81 g/L。逐步提高HRT依次为6、12、24、48和72 h考察其对处理效果的影响,当HRT为24 h时处理效果最好,COD去除率最高达到35%左右。  相似文献   

13.
The removal performance of typical refractory organic compounds in landfill leachate was investigated during the electrochemical (EC) oxidation and anaerobic process combined treatment system in this paper. The results indicated that the treatment of landfill leachate by the combined system was highly effective. The toxicity of leachate was notably decreased after the electrochemical oxidation process and the biodegradability was improved. The concentration of the organic acid with low molecular weight in the leachate increased from 28% to 90% based on the biodegradability assays after the EC oxidation process. The anaerobic digestion could further remove the residual organic compounds. At a hydraulic retention time (HRT) of 16 hours and an organic loading rate (OLR) of 8 kg COD/m3 d, the concentration of COD, SS, ALK, VA, N-TKN, N-NH4+ and P-PO4(3)- [corrected] in UASB effluent were 532, 12, 6744, 400, 540, 455 and 11.6 mg/L, respectively, with approximately 90% removal efficiency of COD. The organic compounds in the landfill leachate revealed different degradation characteristics in the combined system. p-chloroaniline, bisphenol A, 6-methyl-2-phenyl-quinoline, dimethylnaphthaline and N'-(2-methyl-4-chlorophenyl)-N-cyclohexyformamidine, classified into the first group in this paper, were completely removed by the EC oxidation and did not reappear in the effluent of the UASB reactor. Phenylacetic acid, 3-methyl-indole and N-cyclohexyl-acetamide, called the second group, were completely removed, but reappeared in the UASB reactor. 4-methyl-phenol, 3,4-dihydroisoquinoline, 2(3H)-benzothiazolone, exo-2-hydroxycineole and benzothiazole, the third group, were degraded little in the EC oxidation process, but extensively removed by the anaerobic process. Benzoic acid, benzenepropanoic acid and 2-cyano-3,5-dimethyl-1-hydroxypyrrole, the fourth group, concentration obviously increased in the EC process, but was completely removed in the UASB reactor. The content of volatile fatty acids (VFAs) markedly increased from 0.68% in the leachate to 16.18% in the effluent from the electrochemical oxidation process (EC(effl)). In addition, the degradation rate of organic compounds from the landfill leachate was different in the EC oxidation and anaerobic process.  相似文献   

14.
对序批式反应器 (SBR)用于牛场污水的处理进行了试验研究 ,主要研究了三个水力停留时间 (HRT)和有机负荷率对污染物去除率、出水水质和污泥特性的影响。试验结果表明 ,对 10 0 0 0mg/LCOD牛场污水 ,使用 1dHRT ,相应有机负荷率为 10gCOD/L·d时 ,混合出水COD、TS、VS、TKN和TN的去除率分别为 45 %、2 1.4%、34 .2 %、5 3.2 %和 2 2 .2 % ,上清液出水的分别为 80 .2 %、6 3.4%、6 6 .2 %、75 %和 38.3% ;两种出水的SCOD和NH3 N去除率相同 ,分别为 5 0 .0 %和 76 .5 %。经SBR处理后 ,污泥的沉降浓缩性能也有了比较明显的改善。  相似文献   

15.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

16.
对厌氧滤池反应器处理难降解印染废水进行中试研究。结果表明,厌氧滤池反应器水力停留时间(HRT)在8.1~14.6 h之间,进水COD浓度波动较大(500~1 000 mg/L)时,对COD平均去除率为20%。印染废水的BOD5/COD由0.23提高到0.35,废水可生化性明显改善。印染废水中硫酸根浓度略有下降,去除浓度为70 mg/L左右。厌氧滤池进出水颜色明显变化,由紫红色变为蓝黑色,紫外可见光谱分析表明废水中的有机物结构发生变化。  相似文献   

17.
采用自行设计的复合式厌氧反应器在常温下对啤酒废水进行了厌氧发酵产沼气的实验研究,将进水COD控制在5 000 mg/L左右,采取逐步缩短HRT的方法来提高进水有机负荷,结果表明,启动运行41 d之后,产气量上升速度加快,反应器成功启动运行;在稳定运行过程中,随着负荷的升高,产气量呈阶梯式渐次上升,COD去除率保持在90%以上,出水pH值维持在7.0左右,TSS去除率达到60%以上,出水水质较好,说明该反应器具有较好的厌氧消化处理有机废水的能力。  相似文献   

18.
采用厌氧UASB-好氧接触氧化工艺对汽车脱脂废水进行连续处理实验研究。结果表明,在脱脂废水进水COD浓度为6 000 mg/L,厌氧水力停留时间为3.4 d,好氧水力停留时间为2.5 d条件下,COD总去除率平均为93%,厌氧段平均值为38%。厌氧段可以提高出水的可生化性,厌氧-好氧接触氧化工艺效果要明显优于好氧工艺。  相似文献   

19.
为解决稠油废水达标排放问题,构建了一套中试实验装置,以经过除油、浮选和过滤预处理的富含溶解性有机化合物、氮磷缺乏的低浓度难生化稠油废水为原水,进行了187 d的连续运行,结果表明,经过厌氧和好氧生物处理后,出水COD可降至80~100 mg/L以下,再经膜过滤后COD降至60~80 mg/L,加入少量的粉末活性炭进行吸附处理后,出水COD可稳定在50 mg/L以下;水力停留时间从72 h降至30 h时,出水COD基本无变化;气相色谱-质谱分析表明该系统容易去除的有机物为酮类、醇类等物质,而烷烃(C17~C25)和芳烃等为本工艺难降解物质,通过膜生物反应器工艺优化或选择专门降解菌如Acinetobacter spp.进行处理可进一步降低出水COD的浓度。  相似文献   

20.
The effects of organic loading rate and operating temperature on the microbial diversity and performances of upflow anaerobic sludge blanket (UASB) reactors treating palm oil mill effluent (POME) were investigated. The following two UASB reactors were run in parallel for comparison: (1) under a mesophilic condition (37 degrees C) and (2) under a mesophilic condition in transition to a thermophilic condition (57 degrees C). A polymerase chain reaction (PCR)-based denaturing gradient gel electrophoresis (DGGE) analysis showed that the microbial population profiles significantly changed with the organic loading rate (OLR) and the temperature transition from the mesophilic to the thermophilic condition. Significant biomass washout was observed for the mesophilic UASB when operating at a high organic loading rate (OLR) of 9.5 g chemical oxygen demand (COD)/L.d. In contrast, the thermophilic UASB can be operated at this OLR and at a temperature of 57 degrees C with satisfactory COD removal and biogas production. The PCR-based DGGE analysis suggested that the thermophilic temperature of 57 degrees C was suitable for a number of hydrolytic, acidogenic, and acetogenic bacteria.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号