首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.  相似文献   

2.
Air sampling for (1 → 3)-β-D-glucan may be a good method for assessing inhalation exposure to airborne fungi. Pre-sampling contamination of filter media used for sampling (1 → 3)-β-D-glucan may lead to substantial exposure measurement errors. Using the Limulus amebocyte lysate assay, we tested for pre-sampling levels of (1 → 3)-β-D-glucan on three types of filters-mixed cellulose ester (MCE)[1 brand], glass fiber (GF)[1 brand], and polycarbonate (PC)[5 brands]. Levels of (1 → 3)-β-D-glucan on MCE filters exceeded 4586.1 pg per filter. Levels on GF filters averaged 135.3 (± 28.9) pg per filter (range = 94.8-160.4 pg per filter) and levels on PC filters averaged 152.4 (± 236.1) pg per filter (range = non-detectable-1760.7 pg per filter). Efforts to clean MCE and GF filters were unfeasible or unsuccessful. Sonicating PC filters for two hours in ethanol, followed by a wash in pyrogen-free water, effectively eliminated measured levels of (1 → 3)-β-D-glucan on four brands of PC filters, as compared to untreated PC filters. This pretreatment process did not appear to physically damage the PC filters. Air sampling results highlighted the potentially problematic contamination of untreated PC filters. Ensuring that sampling media are free of (1 → 3)-β-D-glucan before sampling is crucial to accurately measure levels of (1 → 3)-β-D-glucan exposure, especially in environments where levels of (1 → 3)-β-D-glucan are low.  相似文献   

3.
Vacuum filter socks were evaluated for recovery efficiency of powdered Bacillus atrophaeus spores from two non-porous surfaces, stainless steel and painted wallboard and two porous surfaces, carpet and bare concrete. Two surface coupons were positioned side-by-side and seeded with aerosolized Bacillus atrophaeus spores. One of the surfaces, a stainless steel reference coupon, was sized to fit into a sample vial for direct spore removal, while the other surface, a sample surface coupon, was sized for a vacuum collection application. Deposited spore material was directly removed from the reference coupon surface and cultured for enumeration of colony forming units (CFU), while deposited spore material was collected from the sample coupon using the vacuum filter sock method, extracted by sonication and cultured for enumeration. Recovery efficiency, which is a measure of overall transfer effectiveness from the surface to culture, was calculated as the number of CFU enumerated from the filter sock sample per unit area relative to the number of CFU enumerated from the co-located reference coupon per unit area. The observed mean filter sock recovery efficiency from stainless steel was 0.29 (SD = 0.14, n = 36), from painted wallboard was 0.25 (SD = 0.15, n = 36), from carpet was 0.28 (SD = 0.13, n = 40) and from bare concrete was 0.19 (SD = 0.14, n = 44). Vacuum filter sock recovery quantitative limits of detection were estimated at 105 CFU m(-2) from stainless steel and carpet, 120 CFU m(-2) from painted wallboard and 160 CFU m(-2) from bare concrete. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling for biological agents such as Bacillus anthracis.  相似文献   

4.
Several occupational exposure limits and guidelines exist for silver, but the values for each depend on the chemical form of the silver compound in question. In the past, it generally was not possible, without prior knowledge of the work process, to distinguish soluble silver from insoluble silver compounds collected in workplace air samples. Therefore, analytical results were historically reported as total silver. In this study, work was conducted to evaluate a method to differentiate between the quantities of water-soluble silver compounds and total silver collected on filters. The investigation entailed an evaluation of an International Organization for Standardization method to determine soluble silver in airborne particulate matter. The study design incorporated laboratory experiments to evaluate analytical figures of merit, such as selection of appropriate filter media and extraction solution, analytical recovery, and sample stability during storage. Polytetrafluoroethylene (PTFE) filters (2 microm, 37 mm) in opaque cassettes were either spiked with known amounts of silver nitrate or contained a known mass of solid silver nitrate. Results showed that over 90% of the silver was recovered from PTFE filters. Also, field studies were conducted in which workplace air samples were collected in two silver refineries. Some of these samples were analyzed only for soluble silver while others were sequentially extracted and analyzed, first, for soluble silver, then for total silver. The mass fractions of soluble silver, as compared to total silver, were approximately 2% or less. This investigation served to validate an international standard procedure for the determination of soluble silver in workplace air samples.  相似文献   

5.
In order to characterize and compare the chemical composition of diesel particulate matter and ambient air samples collected on filters, different extraction procedures were tested and their extraction efficiencies and recoveries determined. This study is an evaluation of extraction methods using the standard 16 EPA PAHs with HPLC fluorescence analysis. Including LC analysis also GC and MS methods for the determination of PAHs can be used. Soxhlet extraction was compared with ultrasonic agitation and pressurized fluid extraction (PFE) using three solvents to extract PAHs from diesel exhaust and urban air particulates. The selected PAH compounds of soluble organic fractions were analyzed by HPLC with a multiple wavelength shift fluorescence detector. The EPA standard mixture of 16 PAH compounds was used as a standard to identify and quantify diesel exhaust-derived PAHs. The most effective extraction method of those tested was pressurized fluid extraction using dichloromethane as a solvent.  相似文献   

6.
The slurry sampling technique has been applied for the determination of arsenic, cadmium and lead in sidestream cigarette smoke condensate (SS CSC) by inductively coupled plasma mass spectrometry (ICP-MS). The smoke collection system consists of a "fishtail" chimney in conjunction with an impaction trap and a mixed cellulose ester (MCE) backup filter for the SS CSC collection. The smoke condensates, collected at three different regions of the system (i.e. the inner wall of the chimney, the impaction trap and the MCE filter), were individually prepared and analyzed and showed that about 70 and 20% of Cd and Pb, respectively, were trapped by the impaction trap and the MCE filter with less than 5% trapped by the chimney. In contrast, about 60% of As was trapped by the impactor and a relatively high percentage of As, about 30%, was deposited onto the inner wall of the chimney. The uneven distribution of trace metals at each collection stage strongly suggested that the composition of smoke aerosol and the associated physical form of the analytes may be different. The yields of As, Cd and Pb for the sidestream cigarette smoke of the 1R4F reference cigarette were 29.5 +/- 2.4, 421 +/- 6.6 and 46.4 +/- 0.9 ng cigarette(-1)(n= 3) respectively, when the cigarette was smoked according to the smoking regime: 45 mL puff volume of 2-s puff duration at an interval of 30 s with 50% ventilation holes covered. The analytical results for the slurry sampling technique were also compared with other sample preparation techniques and show good agreement.  相似文献   

7.
Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter(-1), with three different filter loadings denoted "Low", "Medium" and "High". Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter(-1). Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study.  相似文献   

8.
Development of a field method for measuring manganese in welding fume   总被引:1,自引:0,他引:1  
Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.  相似文献   

9.
Solid speciation of some trace metals (Pb, Cd, Fe, Mn, Cu) having environmental relevance was studied in coastal particulate sampled during the Austral Spring 2000/2001. A nearshore station situated in the Gerlache Inlet of Terra Nova Bay (Ross Sea, Antarctica) was sampled from November to February. Samples were collected using the in situ filtration system FIS500, equipped with polycarbonate membrane filters having different pore sizes (10 microm, 2 microm and 0.4 microm) for the size fraction analysis of particles. The total concentration of metals was determined both in dissolved and particulate fractions, while speciation was determined on particulate by applying a sequential extraction procedure. Concerning the surface and sub-surface layers, it has been observed that concentration of elements is mainly affected by the dynamic of the pack ice melting and by phytoplankton activity.The solid speciation in November and December is similar for all the studied elements, while some differences can be noted in February, when the pack has completely melted and phytoplankton bloom occurs. With the exception of iron, during this sampling period the quantity of metal associated to the labile fraction increases.  相似文献   

10.
The use of underwater gaseous sensors has increased rapidly in the last 10 years. The majority of such sensors employ a thin membrane through which the gas diffuses. These sensors are potentiometric gas-sensing probes and essentially they are ion-selective electrodes. The deployment time of these membranes is curtailed by the formation of biofouling on the membrane leading to erroneous results. The physical properties of a variety of commonly used membranes were investigated using SEM and AFM. This showed that there were differences in topography between the PTFE membranes, such as pore sizes and surface roughness, which may be attributed to the manner in which they are manufactured. The pore size of the PTFE membranes varied greatly, ranging from circular pores with a diameter of 500 nm to elongated pores measuring 1 x 22 microm. The contact angle of each membrane showed that they were all hydrophobic. The amount of fouling on each was also observed and its affect on oxygen diffusion was monitored. Fouling slowed down the response of the instrument and caused reduced diffusion through the membranes. The amount of fouling varied between the membranes with the YSI membrane fouling least. Some of the membranes tested did foul less than others and there could be lifetime advantages of choosing a membrane with a smoother surface and a small pore size.  相似文献   

11.
The foundational idea for this project is that household faucet-mounted water filters may be used as bioforensic sampling devices to detect the extent of a potential bioagent release in domestic water supplies. An optimized eluent solution was determined experimentally by quantifying recoveries of microorganisms from point-of-use (POU) drinking water filters. The optimized extraction protocol was then used in mock bioagent release experiments to determine the feasibility of POU filters as bioforensic sampling devices. Bacillus atrophaeus spores, Escherichia coli and PP7 virus were exposed to filters and the number of attached organisms was determined by enumerating the unattached organisms on selective agar media. Subsequently, the filters were eluted and the percent of extracted organisms was determined based on the number of attached organisms. Two popular brands of carbon block filters retained 92%-99% of representative virus, spore and vegetative bacteria. In back-flush elutions of single filters, the most efficient eluent was identified as a combination of 1% peptone and 1% Tween-80, and extraction recovered 25.4% (+/-17.5%) of attached E. coli, 20.4% (+/-3.6%) of B. atrophaeus spores, and 9.4% (+/-5.2%) of PP7 virions (+/- standard deviations). In bioagent release studies in which filters were challenged with 100 agents mL(-1), greater than 99% of the spores were retained by the filters, and the percent of attached spores that were recovered ranged from 10.4% at day 0 to 4.3% five days after the release event (averaged from five separate experiments). In contrast, E. coli, Salmonella typhimurium and PP7 virus were rapidly inactivated in the chlorinated tap water, indicating their improbable survival in chlorinated water supplies. It is therefore concluded that household water filters can be used as microbial sampling devices for bioforensic applications in the event of a bioagent release in domestic drinking water supplies.  相似文献   

12.
Personal and area air samples were taken at a scrap lead smelter operation in a bullet manufacturing facility. Samples were taken using the 37-mm styrene-acrylonitrile closed-face filter cassette (CFC, the current US standard device for lead sampling), the 37-mm GSP or "cone" sampler, the 25-mm Institute of Occupational Medicine (IOM) inhalable sampler, and the 25-mm Button sampler (developed at the University of Cincinnati). Polyvinylchloride filters were used for sampling. The filters were pre- and post-weighed, and analyzed for lead content using a field-portable X-ray fluorescence (XRF) analyzer. The filters were then extracted with dilute nitric acid in an ultrasonic extraction bath and the solutions were analyzed by inductively coupled plasma optical emission spectroscopy. The 25-mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37-mm filters. The single reading from the 25-mm filters was adjusted for the nominal area of the filter to obtain the mass loading, while the three readings from the 37-mm filters were inserted into two different algorithms for calculating the mass loadings, and the algorithms were compared. The IOM sampler was designed for material collected in the body of the sampler to be part of the collected sample as well as that on the filter. Therefore, the IOM sampler cassettes were rinsed separately to determine if wall-loss corrections were necessary. All four samplers gave very good correlations between the two analytical methods above the limit of detection of the XRF procedure. The limit of detection for the 25-mm filters (5 microg) was lower than for the 37-mm filters (10 microg). The percentage of XRF results that were within 25% of the corresponding ICP results was evaluated. In addition, the bias from linear regression was estimated. Linear regression for the Button sampler and the IOM sampler using single readings and the GSP using all tested techniques for total filter loading gave acceptable XRF readings at loadings equivalent to sampling at the OSHA 8-hour Action Level and Permissible Exposure Limit. However, the CFC only had acceptable results when the center reading corrected for filter area was used, which was surprising, and may be a result of a limited data set. In addition to linear regression, simple estimation of bias indicated reasonable agreements between XRF and ICP results for single XRF readings on the Button sampler filters, (82% of the individual results within criterion), and on the IOM sampler filters (77% or 61%--see text), and on the GSP sampler filters using the OSHA algorithm (78%). As a result of this pilot project, all three samplers were considered suitable for inclusion in further field research studies.  相似文献   

13.
研究以单元素标准膜为基础,结合NIST SRM 2783颗粒物滤膜标准样品,建立了波长色散-X射线荧光光谱法测定PM2.5中23种无机元素的测定方法,优化了测试条件,测量一个样品耗时约15 min,计算了各元素的方法检出限。对NIST SRM 2783滤膜标准品在一周内重复测定10次来计算方法的准确度与精密度,测定结果显示大多数元素的测量值在给出的参考值范围内,且测量标准偏差一般在10%以内。对比了石英与聚四氟乙烯材质(Teflon)滤膜的空白值,石英滤膜中Si、Fe、Na、Mg、Al、K、Ca等元素的背景值较高,Teflon滤膜的背景值较低,推荐选用Teflon滤膜作为PM2.5组分分析采样滤膜。分别用波长色散-X射线荧光光谱法及酸消解-ICP-MS法测定了样品膜中的元素组分,得到的测定结果基本一致。  相似文献   

14.
On-site measurement of lead in workplace air filter samples and paint chip samples by ultrasonic extraction and anodic stripping voltammetry (UE-ASV) was evaluated in the field during renovation and remodeling activities in residences having leaded paint. Aerosol and paint samples were collected using standard techniques, and the samples were analyzed on-site for lead content by portable UE-ASV. Lead in sample extracts was subsequently determined by atomic absorption (AA) spectrometry in a fixed-site laboratory. The remaining sample extracts plus undissolved material (air filters or paint particles) were then subjected to hot plate digestion in concentrated nitric acid-30% hydrogen peroxide prior to AA analysis for lead. Field UE-ASV lead data were thereby compared to UE-AA and hot plate digestion-AA results from fixed-site laboratory lead measurement. Determination of lead in air filter samples by UE-ASV (over the range of 5 microg to approximately 800 microg Pb per sample) was extremely well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, a significant negative bias associated with ASV measurement was observed, and this was attributed to a matrix effect. Lead measurement in paint chip samples by UE-ASV (over the range of approximately 10 to approximately 550 microg Pb g(-1)) was well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, correlation and precision were lower for lead measurement in paint samples as compared to aerosol samples, and a negative bias was also observed. Lead measurements by UE-AA were compared to lead determinations by hot plate digestion-AA; these data were highly correlated and demonstrated no significant bias. Thus it was concluded that the ultrasonic extraction procedure performed equivalently to hot plate digestion. It was reasoned that matrix effects due to the preparation and analysis of paint chip particles resulted in greater imprecision as well as negative bias by ASV measurement. Despite significant negative bias in this sample set, UE-ASV offers promise for on-site measurement of lead in samples of interest in occupational and environmental health.  相似文献   

15.
In this study, glycerol was tested as a collection substrate for passive bioaerosol sampling. Filters (mixed cellulose acetate and nitrate) were soaked in glycerol and exposed for an aerosol from three different fungal species: Penicillum commune, Aspergillus versicolor and Paecilomyces variotii. The passive sampling method was compared with a closed-face polycarbonate filter sampling method. Exposure was performed in an exposure chamber. The total number of spores was determined by microscopic techniques, and the cultivable number was determined by cultivation on Malt Extract Agar dishes. The glycerol soaked filter demonstrated a good correlation with the closed-face sampler with regard to the total count. Spores stored in a pumped filter cassette were not affected by storage for up to 7 days. On the other hand, the culturability of the spores was markedly decreased after 1 day when stored on glycerol soaked filters.  相似文献   

16.
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.  相似文献   

17.
During the 2002-2003 austral summer field season, aerosol samples were collected at a coastal (Terra Nova Bay--Northern Victoria Land) and an inland site (Dome C--East Antarctic Plateau). The sampling was carried out by stacked filter units made up of two filters at different porosity (5.0 and 0.4 microm at Terra Nova Bay and 3.0 and 0.4 microm at Dome C), able to roughly separate a coarse from a fine fraction. At Dome C, a further investigation on aerosol size distribution was performed by an inertial impactor able to collect aerosol particles on 8 size classes (from 10 to 0.4 microm). Atomic Force Microscopy was applied to the filter collecting the finer fraction in both sites in order to assess the real cut-off value of the filter sandwich apparatus and to reconstruct the volume size distribution. At the employed flow conditions, the real cut-off value was revealed to be about one third with respect to the filter nominal porosity in both stations. The size distribution plots showed a bimodal distribution with a mode centered around 0.22 microm in both the sites and a second broader mode which is centered between 0.3 microm and 1.2 microm diameter at Terra Nova Bay and shifted toward higher values (centred around 1.0 microm diameter) at Dome C. Each filter was analysed for the main and trace ionic components allowing evaluation of the contributions of primary and secondary aerosol sources at the two sites as a function of the particle size class. The coastal site is mainly affected by primary and secondary marine inputs: the sea spray contribution (Na+, Mg2+, Cl- and ssSO4(2-)) is dominant (77% w/w) in the coarse fraction whereas the biogenic source (methanesulfonate and nssSO4(2-)) prevails (67.5% w/w) in the fine fraction. In this fraction a significant contribution (15.5% w/w) is provided by ammonium likely to be related to surrounding penguin colonies. Dome C atmosphere is characterised by fine particles arising from secondary sources and long-range transport processes. The main component in the fine and coarse fractions at Dome C is sulfate whose nssSO4(2-) represents the 99.5% and the 92.3%(w/w) in fine and coarse fraction, respectively. The observed agreement between nssSO4(2-) and methanesulfonate temporal profiles in the fine fraction demonstrates that biogenic emissions dominate the inland background aerosol. Results from the sampling by the 8-stage impactor at Dome C are presented here: chloride and nitrate are mainly deposited on the 10-2.1 microm stages while the highest sulfate concentration was found in the submicrometric fraction which turned out to be the most acidic. Such a distribution is able to prevent nitrate and chloride re-emission as gaseous HCl and HNO3 in the 10-2.1 microm stages, arising from the exchange reaction between chloride and nitrate salts and sulfuric acid. Moreover, the concentration peak observed for nitrate in coarser fractions is probably related also to the formation of hygroscopic NH4NO3 particles and nitrate adsorption on sea salt particles.  相似文献   

18.
Airborne lubricant emissions are a serious health hazard for employees in the metal working industry. The basic components of lubricants are oils and additives for adapting the properties to achieve the process demands. The oils used in lubricants are either mineral, synthetic or of biological origin. The lubricants are used as water-emulsions and also as straight oils. Extreme process conditions cause considerable amounts of aerosol and vapour emissions of lubricants into the working environment. Fibre filters are used in industrial demisters for pollution control and also for sampling purposes. Re-evaporation of separated lubricants from loaded fibre filters causes increased vapour emissions. Quantification of lubricant vapour emission was the subject of this research. An apparatus and an appropriate procedure for measuring the dynamic behaviour of evaporative losses from fibre filters were developed. The test piece of a loaded fibre filter was fixed in a sampling probe according to VDI 2066. The vapour concentration of organic compounds in downstream air was measured in real-time by using a photo-ionisation detector (PID). The PID was checked by sampling the vapour on an oleophilic adsorbent resin, solvent extraction and quantitative IR analysis and also gravimetrically. The two basic processes of filtering volatile aerosols are, on the one hand, collecting droplets on the fibres and, on the other hand, the evaporation of collected liquid. These two processes had to be separated in order to measure the increase of the vapour concentration caused by the tested fibre filter. The experiments were carried out using pure dodecane and hexadecane in order to avoid difficulties due to the unknown chemical composition of lubricant vapour. The variation of the air flow and the initial liquid mass on the filter covered the relevant range for industrial fibre demisters and for sampling methods based on collecting aerosols on fibre filters. It was found that the downstream air was saturated with lubricant vapour for a wide range of filter loads and filtration velocities. From the results obtained it can be concluded that loaded industrial filter systems emit air with saturation vapour concentration throughout their operation. Hence, vapour emissions can be estimated easily if the saturation vapour pressure and the mean relative molecular mass are known. Moreover, results obtained from measurements of filters with low loads confirm that the phase transition from liquid to vapour is influenced by the identified process parameters. This is relevant for measurement methods using fibre filters for sampling volatile aerosols. A semi-empirical model to estimate the evaporative losses for low loadings is proposed. However, further research is necessary to determine the full range of parameters that are relevant for evaporative losses from filters loaded with low masses of aerosols.  相似文献   

19.
A novel, simple and sensitive liquid chromatography-hydride generation online coupled with atomic fluorescence spectrometry (LC-HG-AFS) method was developed for simultaneous determination of p-arsanilic acid (p-ASA) and roxarsone in feed. 20% Methanol aqueous was used as extraction reagent, after preprocessing samples by ultrasonic oscillation, then injected into the chromatography Waters symmetry shield RP18 analytical column (150mm x 4.6mm, 5 microm), finally detected by an atomic fluorescence spectrometer. The calibration curves of analyses were linear over a range of concentrations (0.2-4mg L-1 and the correlation coefficients were higher than 0.9990. The limits of detection were 0.2 mg L-1. The method has been validated by linearity, precision and recovery. p-ASA and roxarsone in feed can be successfully and simultaneously determined using the developed method without a tedious pretreatment procedure.  相似文献   

20.
A field study was established to investigate the chemical composition of atmospheric aerosols in Chicago, IL. One goal of this study was to determine the influence of precursor trace gases and local meteorology on concentrations of secondary aerosol ionic species. This paper describes the method details, shows the method is analytically valid, and reports overall as well as some specific results found during the field study. Two particulate air samples were collected per day onto quartz fiber filters at the Loyola University Chicago Air Station during the summer months in 2002–2004. In parallel, mixing ratios of ozone and nitrogen oxides were monitored and weather parameters were recorded. Particulates were extracted from the filter substrates and the subsequent solutions were analyzed by ion chromatography for anions, including low molecular weight organic acids, and cations. A washing procedure was implemented to reduce the high background values of the quartz fiber filters. Method validation showed that the collection method was efficient for all ions with exception of nitrate, whose efficiency of 70% indicated losses caused by volatilization. The extraction method also proved efficient for both field and laboratory samples, and the repeatability of the method was high with relative standard deviations less than 10% for all ions. Reproducibility of the results was determined by comparison of sulfate to sulfur analyzed by total reflection X-ray fluorescence spectrometry and proved to be high as well. Concentrations differed significantly between the three summer studies due to varying levels of precursor species as a consequence of distinct temperatures and wind direction profiles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号