首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
Chen WS  Liang JS 《Chemosphere》2008,72(4):601-607
Oxidative degradation of dinitrotoluene (DNT) isomers and 2,4,6-trinitrotoluene (TNT) in spent acid was conducted by Electro-Fenton's reagents. The electrolytic experiments were carried out to elucidate the influence of various operating parameters on the performance of mineralization of total organic compounds (TOC) in spent acid, including reaction temperature, dosage of oxygen, sulfuric acid concentration and dosage of ferrous ions. It deserves to note that organic compounds could be completely destructed by Electro-Fenton's reagent with in situ electrogenerated hydrogen peroxide obtained from cathodic reduction of oxygen, which was mainly supplied by anodic oxidation of water. Based on the spectra analyzed by gas chromatograph/mass spectrometer, it is proposed that initial denitration of 2,4,6-TNT gives rise to formation of 2,4-DNT and/or 2,6-DNT, which undergo the cleavage of nitro group into o-mononitrotoluene, followed by denitration to toluene and subsequent oxidation of the methyl group. Owing to the removal of both TOC and partial amounts of water simultaneously, the electrolytic method established is potentially applied to regenerate spent acid from toluene nitration processes in practice.  相似文献   

2.
Catalkaya EC  Kargi F 《Chemosphere》2007,69(3):485-492
Advanced oxidation of diuron in aqueous solution by Fenton's reagent using FeSO(4) as source of Fe(II) was investigated in the absence of light. Effects of operating parameters namely the concentrations of pesticide (diuron), H(2)O(2) and Fe(II) on oxidation of diuron was investigated by using Box-Behnken statistical experiment design and the surface response analysis. Diuron oxidation by the Fenton reagent was evaluated by determining the total organic carbon (TOC), diuron, and adsorbable organic halogen (AOX) removals. Concentration ranges of the reagents resulting in the highest level of diuron oxidation were determined. Diuron removal increased with increasing H(2)O(2) and Fe(II) concentrations up to a certain level. Diuron concentration had a more profound effect than H(2)O(2) and Fe(II) in removal of diuron, TOC and AOX from the aqueous solution. Nearly complete (98.5%) disappearance of diuron was achieved after 15min reaction period. However, only 58% of diuron was mineralized after 240min under optimal operating conditions indicating formation of some intermediate products. Optimal H(2)O(2)/Fe(II)/diuron ratio resulting in the maximum diuron removal (98.5%) was found to be 302/38/20 (mgl(-1)).  相似文献   

3.
In this paper we evaluated the H2O2/UV and the Fenton's oxidation processes for the treatment of tannery wastewater under different experimental conditions. Efficiencies were judged by the amounts of organic substances degraded or eliminated under these treatment techniques. Daphnia magna and Vibrio fischeri were used to monitor toxicity. Organic compounds contained in the untreated and treated tannery wastewater were determined and identified using substance specific techniques. Gas chromatography-mass spectrometry (GC-MS) in positive electron impact (EI(+)) mode was applied to determine volatile organics. Atmospheric pressure ionization (API) mass (MS) and tandem mass spectrometry (MS-MS) coupled with flow injection analysis (FIA) or liquid chromatography (LC) were used to detect or identify polar organic pollutants. The experimental results indicated that both oxidation processes--H2O2/UV at pH 3 and Fenton at pH 3.5--are able to reduce TOC content by mineralisation of the organic compounds.  相似文献   

4.
Seol Y  Javandel I 《Chemosphere》2008,72(4):537-542
Fenton's reagent, a solution of hydrogen peroxide and ferrous iron catalyst, is used for an in situ chemical oxidation of organic contaminants. Sulfuric acid is commonly used to create an acidic condition needed for catalytic oxidation. Fenton's reaction often involves pressure buildup and precipitation of reaction products, which can cause safety hazards and diminish efficiency. We selected citric acid, a food-grade substance, as an acidifying agent to evaluate its efficiencies for organic contaminant removal in Fenton's reaction, and examined the impacts of using citric acid on the unwanted reaction products. A series of batch and column experiments were performed with varying H2O2 concentrations to decompose selected chlorinated ethylenes. Either dissolved iron from soil or iron sulfate salt was added to provide the iron catalyst in the batch tests. Batch experiments revealed that both citric and sulfuric acid systems achieved over 90% contaminant removal rates, and the presence of iron catalyst was essential for effective decontamination. Batch tests with citric acid showed no signs of pressure accumulation and solid precipitations, however the results suggested that an excessive usage of H2O2 relative to iron catalysts (Fe2+/H2O2<1/330) would result in lowering the efficiency of contaminant removal by iron chelation in the citric acid system. Column tests confirmed that citric acid could provide suitable acidic conditions to achieve higher than 55% contaminant removal rates.  相似文献   

5.
The chemical decomposition of aqueous solutions of various chlorophenols (4-chlorophenol (4-CP), 2,4-dichlorophenol (2-DCP), 2,4,6-trichlorophenol (2,4,6-TCP) and 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP)), which are environmental priority pollutants, is studied by means of single oxidants (hydrogen peroxide, UV radiation, Fenton's reagent and ozone at pH 2 and 9), and by the Advanced Oxidation Processes (AOPs) constituted by combinations of these oxidants (UV/H2O2 UV/Fenton's reagent and O3/UV). For all these reactions the degradation rates are evaluated by determining their first-order rate constants and the half-life times. Ozone is more reactive with higher substituted CPs while OH* radicals react faster with those chlorophenols having lower number of chlorine atoms. The improvement in the decomposition levels reached by the combined processes, due to the generation of the very reactive hydroxyl radicals. in relation to the single oxidants is clearly demonstrated and evaluated by kinetic modeling.  相似文献   

6.
Goslan EH  Gurses F  Banks J  Parsons SA 《Chemosphere》2006,65(7):1113-1119
A comparison of four treatment technologies for reduction of natural organic matter (NOM) in a reservoir water was made. The work presented here is a laboratory based evaluation of NOM treatment by UV-C photolysis, UV/H(2)O(2), Fenton's reagent (FR) and photo-Fenton's reagent (PFR). The work investigated ways of reducing the organic load on water treatment works (WTWs) with a view to treating 'in-reservoir' or 'in-pipe' before the water reaches the WTW. The efficiency of each process in terms of NOM removal was determined by measuring UV absorbance at 254 nm (UV(254)) and dissolved organic carbon (DOC). In terms of DOC reduction PFR was the most effective (88% removal after 1 min) however there were interferences when measuring UV(254) which was reduced to a lesser extent (31% after 1 min). In the literature, pH 3 is reported to be the optimal pH for oxidation with FR but here the reduction of UV(254) and DOC was found to be insensitive to pH in the range 3-7. The treatment that was identified as the most effective in terms of NOM reduction and cost effectiveness was PFR.  相似文献   

7.
Oxidation of TNT by photo-Fenton process   总被引:4,自引:0,他引:4  
Liou MJ  Lu MC  Chen JN 《Chemosphere》2004,57(9):1107-1114
A series of photo-Fenton reactions have been performed for the degradation of 2,4,6-trinitrotoluene (TNT) in a 4.2-l reactor. The degradation reaction rate of TNT followed a pseudo-first-order behavior; and the rate constants for 2.4mW cm(-2)UV only, 2.4mW cm(-2)UV/H(2)O(2), Fenton, photo-Fenton (2.4mW cm(-2)) and photo-Fenton (4.7mW cm(-2)) were 0.002min(-1), 0.007min(-1), 0.014min(-1), 0.025min(-1) and 0.037min(-1), respectively. Increasing the intensity of UV light, and the concentrations of ferrous ions and hydrogen peroxide promoted the oxidation rate under the experimental conditions in this study. The weighting factor (f), the Fe(II)-promoted efficiency (r) and the promoted-UV light efficiency (p) were calculated to clarify their effects on the TNT oxidation. Moreover, the inhibition effect of hydroxyl radical was also observed in both Fenton and photo-Fenton oxidation when the concentration of Fe(II) were higher than 2.88mM. Solid phase micro-extraction was first applied to the separation of the organic byproducts from TNT oxidation. GC/MS was employed to identify the byproducts during the Fenton and photo-Fenton oxidation of TNT. These compounds were clarified as 1,3,5-trinitrobenzene, 1-methyl-2,4-dinitrobenzene 2,5-dinitrobenzoic acid and 1,3-dinitrobenzene. By these byproducts, the mechanisms of the methyl group oxidation, decarboxylation, aromatic ring breakage, and hydrolysis can be recognized and demonstrated. The pathway of TNT oxidation by photo-Fenton process was also proposed in this study.  相似文献   

8.
不同高级氧化法对水中低浓度药物甲硝唑降解过程的比较   总被引:3,自引:0,他引:3  
采用UV、H2O2、UV/H2O2、Fenton、UV/Fenton和UV/TiO2方法,对水中低浓度的药物甲硝唑进行降解。通过HPLC和UV-Vis光谱得到的甲硝唑去除率。详细讨论了Fe2+、TiO2和H2O2的初始浓度以及溶液的初始pH值对降解效率的影响。结果表明,UV/Fenton和UV/TiO2 2种系统对水中低浓度甲硝唑均有很好的去除效果,但前者的光催化效率更高。在甲硝唑浓度=6 μmol/L,H2O2和Fe2+的初始浓度分别为0.5 mg/L和2.94 μmol/L,pH=4的条件下,UV/Fenton方法对甲硝唑水溶液光催化的最佳效率为95.8%。  相似文献   

9.
Oxidation of ethylene glycol in aqueous solutions was found to occur with the addition of Fenton's reagent with further conversion observed upon UV irradiation. The pH range studied was 2.5-9.0 with initial H2O2 concentrations ranging from 100 to 1000 mg/l. Application of this method to airport storm-water could potentially result in reduction of chemical oxygen demand by conversion of ethylene glycol to oxalic and formic acids. Although the amount of H2O2 added follows the amount of ethylene glycol degraded, smaller H2O2 doses were associated with increases in the ratio of ethylene glycol removed per unit H2O2 added indicating the potential of pulsed doses or constant H2O2 feed systems. Ethylene glycol removal was enhanced by exposure to UV light after treatment with Fenton's reagent, with rates dependent on initial H2O2 concentration. In addition to ethylene glycol, the principle products of this reaction, oxalic and formic acids, have been shown to be mineralized in other HO generating systems presenting the potential for ethylene glycol mineralization in this system with increased HO* production.  相似文献   

10.
Fenton组合工艺处理焦化厂生化出水的应用研究   总被引:2,自引:1,他引:1  
比较了Fenton氧化、Fenton氧化+活性炭及Fenton氧化+生物活性炭工艺对焦化厂生化出水的处理效果.结果表明,Fe2+、H2O2的投加量分别为56、27.2 mg/L时,Fenton氧化工艺对水样的UV254、颜色度(VIS380)、COD和总氰均有较好的去除效果;Fenton氧化+活性炭工艺在有效去除UV254、VIS380、COD和总氰的同时,能强化活性炭的吸附效果,并能显著提高水样的生化性能;Fenton氧化+生物活性炭工艺能有效去除UVM254,VIS380、COD与总氰,使出水达到<污水综合排放标准>(GB 8978-1996)一级标准.  相似文献   

11.
Xu XR  Zhao ZY  Li XY  Gu JD 《Chemosphere》2004,55(1):73-79
Degradation of methyl tert-butyl ether (MTBE) in aqueous solution by Fenton's reagent (Fe2+ and H2O2) was investigated. Effects of reaction conditions on the oxidation efficiency of MTBE by Fenton's reagent were examined in batch experiments. Under optimum conditions, 15 mM H2O2, 2 mM Fe2+, pH 2.8 and room temperature, the initial 1 mM MTBE solution was reduced by 99% within 120 min. Results showed that MTBE was decomposed in a two-stage reaction. MTBE was first decomposed swiftly based on a Fe2+/H2O2 reaction and then decomposed somewhat less rapidly based on a Fe3+/H2O2 reaction. The detection of Fe2+ also supported the theory of the two-stage reaction for the oxidation of MTBE by Fenton's reagent. The dissolved oxygen in the solution decreased rapidly in the first stage reaction, but it showed a slow increase in the second stage with a zero-order kinetics. A reaction mechanism involving two different pathways for the decomposition of MTBE by Fenton's reagent was also proposed. Chemicals including tert-butyl formate, tert-butyl alcohol, methyl acetate and acetone were identified to be the primary intermediates and by-products of the degradation processes.  相似文献   

12.
Pre-oxidation and coagulation of textile wastewater by the Fenton process   总被引:30,自引:0,他引:30  
Kang SF  Liao CH  Chen MC 《Chemosphere》2002,46(6):923-928
This paper evaluates the Fenton process, involving oxidation and coagulation, for the removal of color and chemical oxygen demand (COD) from synthetic textile wastewater containing polyvinyl alcohol and a reactive dyestuff, R94H. The experimental variables studied include dosages of iron salts and hydrogen peroxide, oxidation time, mixing speed and organic content. The results show that color was removed mainly by Fenton oxidation. The color removal reached a maximum of 90% at a reaction time of 5 min under low dosages of H2O2 and Fe2+. In contrast, the COD was removed primarily by Fenton coagulation, rather than by Fenton oxidation. The ratio of removal efficiency between Fenton process and ferric coagulation was 5.6 for color removal and 1.2 for COD removal. It is concluded that Fenton process for the treatment of textile wastewater favors the removal of color rather than COD.  相似文献   

13.
强化UV/Fenton法降解水中苯酚的研究   总被引:3,自引:0,他引:3  
研究了UV/Fenton法处理含苯酚废水时H2 O2 和FeSO4 加入量及苯酚初始浓度对酚去除效果的影响及C2 O2 -4 对UV/Fenton法的增强效果。 [H2 O2 ]=2 0mmol/L ,[FeSO4 ]=5mmol/L ,反应 2 0min ,苯酚初始浓度为 5 0mg/L时 ,酚去除率达 99%。UV/Fenton体系中引入C2 O2 -4 后可有效提高对紫外和可见光的利用率 ,进而提高了对高浓度苯酚废水去除效果  相似文献   

14.
Fenton氧化/高浓度泥浆法处理矿山废水   总被引:2,自引:0,他引:2  
为了解决某大型铜矿废水COD不达标问题,采用Fenton氧化对原有高浓度泥浆(HDS)工艺进行改进。探讨了Fenton氧化矿山废水各指标的去除效果以及H2O2浓度对出水COD去除效果的影响,结果表明,Fenton氧化-电石乳中和絮凝沉淀工艺处理矿山废水是可行的,最优实验条件为:pH稳定在3.0~4.5,H2O2投加量0.5 mL/L,电石乳投加量8.5 g/L,PAM投加量1.5 mg/L;系统对废水COD的去除机理是加入的H2O2和矿山酸性废水中的Fe2+离子在低pH下形成Fenton试剂;系统对TFe、Zn2+、Cu2+ 的去除效果比Mn2+的去除效果更稳定。  相似文献   

15.
In this study, advanced oxidation technologies, namely Fenton Process (FP), Fenton-Like Process (FLP), ozonation (O3) and O3/H2O2 processes, were applied to synthetic wastewater containing 3-indolebutyric acid (IBA). The effectiveness of each process was investigated at different pH values, Fe(+2), Fe(+3), O3 and H2O2 concentrations with respect to the removal efficiencies for chemical oxygen demand (COD) and total organic carbon (TOC). The best removal efficiencies were seen at pH 3 and 2 mM Fe concentration in both FP and FLP, in which the optimum H2O2 concentrations were 6 mM for FP and 10 mM for FLP. Optimum process conditions were pH 12 for the O3 process, pH 9 for the O3/H2O2 process and 1:1 O3/H2O2 molar ratio. The highest COD removal efficiency was 86 percent, obtained in the O3/H2O2 process and the highest TOC removal efficiency was obtained at 77 percent in the FP.  相似文献   

16.
通过Fenton法和结合聚合硫酸铁的混凝作用,实现垃圾渗滤液氧化塘出水COD的深度处理;并利用水泥水化产物的凝胶物质,强化COD去除率。30%H2O2投加量为0.75mL/L、七水硫酸亚铁投加量为1.5g/L、n(H2O2):n(Fe^2+)=1.2:1(摩尔比)时,Fenton法对渗滤液COD的去除率可达52%;水灰比为2:1、搅拌24h的水泥水化物将Fenton法的出水pH值从4调至10,该工艺流程总的COD去除率为73.6%,较普通的Ca(OH)2调节法提高9.3%,出水COD可以从进水的1200mg/L降至315mg/L。  相似文献   

17.
With the aim to evaluate the effect of temperature, 4-chloro-3-methyl phenol (CMP) degradation by Fenton's reagent was investigated at 25 and 70 degrees C under the following initial conditions: [CMP]0 = 10 mM, [Fe2+]0 = 0.5 mM; ([H2O2]0/[CMP]0) = 80, pH0 = 3. The results indicated that CMP degradation was strongly influenced by temperature. In fact, the maximum TOC removal, achieved after ca. 24h, was by far greater at 70 degrees C (85%) than at 25 degrees C (36%). The same happened for organic chlorine (TOX) conversion into inorganic chloride, i.e. 100%, after 3 h at 70 degrees C, and 87%, after 27 h at 25 degrees C. As the recorded trends of CMP removal and chloride formation were basically the same, hydroxy substitution (ipso-substitution) was hypothesised as one likely mechanism of CMP degradation. The higher level of mineralization recorded at 70 degrees C was ascribed to: (i) a greater *OH concentration; (ii) a consequently greater extent of CMP oxidation to organic acids; (iii) a higher decarboxylation rate of such acids. An interesting consequence of such extended organic acids decarboxylation was a pH increase up to 8 that, in turn, caused, in the treated mixture, the decomposition of excess H2O2 as well as the precipitation of iron ions. These two latter outcomes are technologically important considering that usually, before discharging Fenton treated wastewater, specific polishing steps are required just to remove iron ions, decompose excess hydrogen peroxide and neutralise the pH.  相似文献   

18.
The removal of pollutants in saline medium by the Fenton's reagent needs a more detailed investigation, since the presence of chloride may inhibit or retard degradation. Phenol was used as a model pollutant and the influence of some important process variables for the removal of total organic carbon and phenol were investigated, such as FeSO4 and H2O2 concentrations, pH and salinity. The reactivity of iron cations and alternative procedures of applying UV radiation (photo-Fenton) were evaluated. Phenol was fast and completely removed by the Fenton's process even in a high saline medium (50,000mg NaCll(-1)). However, TOC was only moderately or poorly removed in saline media, depending on the salt concentration. When the photo-Fenton process was used, mineralization was improved and high TOC removals were observed in moderately saline media (NaCl concentration < or =10,000mgl(-1)). For the highest NaCl concentration tested (50,000mgl(-1)) only a moderate TOC removal was observed (50%).  相似文献   

19.
焦化废水泡沫分离液的Fenton催化氧化预处理   总被引:1,自引:0,他引:1  
以焦化废水处理过程产生的泡沫分离液为研究对象,对其进行Fenton催化氧化处理实验,考察H2O2用量、Fe2+浓度、pH和反应时间4个因素对处理效果的影响,并结合GC/MS方法比较处理前后泡沫分离液中有机物的种类及其生物降解性的变化。结果表明,采用[H2O2]=100 mmol/L、[Fe2+]=100 mg/L、pH=3、反应时间为30 min的Fenton催化氧化反应条件,可以使分离液的COD去除率达到68%以上;经Fenton处理后,分离液的B/C值由0.12提高至0.38,生物降解性明显改善;通过GC/MS的分析,基本明确分离液中含有的有机物主要为酚、胺、腈、酯类有机物及喹啉、吡啶等杂环化合物,大多数属于难降解且生物毒性较强的有机物。针对这些复杂组分共存的泡沫分离液,利用Fenton试剂较强的氧化能力能够将其含有的有毒/难降解有机物转化为低毒或无毒的小分子有机物,为其后续的生物处理创造良好的条件。  相似文献   

20.
以电化学方法制备·OH ,并探讨了体系内的反应机理 ;电生成·OH对十二烷基苯磺酸钠 (dodecylben zenesul phonicacid (6 ) sodiumsalt ,DBS)水溶液有明显的降解效果 ,CODCr降解率 >85 % ;比较了处理前后DBS的红外光谱、UV、I V循环伏安曲线的变化。·OH可以将DBS中的烷基碳链断裂 ,并最终将其降解为H2 O和CO2 等无机小分子。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号