首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 32 毫秒
1.
ABSTRACT: The East Lansing-Meridian Water and Sewer Authority studied a sand-gravel esker near the existing water treatment plant to determine its potential as an independent surface water supply. The nearby Red Cedar River was also investigated as a possible source of water for immediate treatment or for recharge of the esker. Although the bedrock aquifer (Grand River and Saginaw Formations) yields water adequate for the next 20 years, potential savings in treatment (hardness, iron) and pumping costs, estimated at $30,000 per year for present demand of 5 MGD, are attractive incentives for a surface water-esker recharge program. Operation savings would also be realized by constructing additional bedrock wells in new areas. The river-esker-recharge and new wellfield alternatives are compared for cost-effectiveness. Land costs make the recharge alternative more expensive. The land is undeveloped suburban property with potential for recreational use in conjunction with water supply. More places of outdoor retreat and aesthetics are needed in the Lansig Metropolitan area. A portion of the land costs would have to be borne by these or other interests for the river recharge scheme to be economically feasible.  相似文献   

2.
ABSTRACT: Artificial recharge as a means of augmenting water sup plies for irrigation is a management alternative which policy makers in ground water decline areas are beginning to consider seriously. A conceptual model is developed to evaluate the economic benefits from ground water recharge under conditions where the major water use is irrigation. The methodology presented separates recharge benefits into two components: pumping cost savings and aquifer extension benefits. This model is then applied to a Nebraska case to approximate the value of recharge benefits as a function of aquifer response. discount rate, and commodity prices. It was found that recharge benefits vary from less than $2 to over $6 an acre foot recharged.  相似文献   

3.
ABSTRACT: The Edwards Aquifer is one of the most studied and most prolific aquifers in the United States. The aquifer is a heavily fractured and faulted carbonate aquifer with transmissivities in excess of 100 ft2/s. The City of San Antonio relies upon the Edwards Aquifer as its sole source for water. Much work has been done on quantifying recharge to the aquifer and discharge from wells and acquiring aquifer characteristics from pumping tests, specific capacity tests, and geophysical logs. Although the aquifer has been well studied in Bexar County, much less is known about the Edwards Aquifer in Kinney County. This is partly due to the lower population within the county (approximately 3,500 people) relative to the eastern counties (Uvalde, Medina, Bexar, Comal, and Hays) and the great distance of Kinney County from high profile discharge areas such as the City of San Antonio and Comal and San Marcos Springs. Three key products resulted from this study: (1) exploratory well drilling and the largest aquifer test in the county that were conducted to evaluate the well yields within a 10,000 acre study area in which a drawdown of 2.5 ft approximately 1.2 miles away was observed while pumping at approximately 4,600 gpm; (2) a recharge estimate for the Edwards Aquifer within Kinney County of approximately 71,382 ac‐ft/yr; and (3) locating the Brackettville Groundwater Divide from an evaluation of ground water flow direction and hydrograph analysis. These results help evaluate the complex hydraulics occurring within Kinney County and aid in development of ground water modeling that will be used in managing the Edwards Aquifer.  相似文献   

4.
ABSTRACT: This study estimates subsurface return flow and effective ground water recharge in terraced fields in northern Taiwan. Specifically, a three dimensional model, FEMWATER, was applied to simulate percolation and lateral seepage in the terraced fields under various conditions. In the terraced paddy fields, percolation mainly moves vertically downward in the central area, while lateral seepage is mainly focused around the bund. Although the simulated lateral seepage rate through the bund exceeded the percolation rate in the central area of the paddy field, annual subsurface return flow at Pei‐Chi and Shin‐Men was 0.17 × 106 m3 and 0.37 × 106 m3, representing only 0.17 percent and 0.21 percent of the total irrigation water required for rice growth at Pei‐Chi and Shin‐Men, respectively. For upland fields, the effective ground water recharge rate during the second crop period (July to November) exceeded that during the first crop period (January to May) because of the wet season in the second crop period. Terraced paddy fields have the most efficient ground water recharge, with 21.2 to 23.4 percent of irrigation water recharging to ground water, whereas upland fields with a plow layer have the least efficient ground water recharge, with only 4.8 to 6.6 percent of irrigation water recharging to ground water. The simulation results clearly revealed that a substantial amount of irrigation water recharges to ground water in the terraced paddy, while only a small amount of subsurface return flow seeps from the upstream to the downstream terraced paddy. The amounts of subsurface flow and ground water recharge determined in the study are useful for the irrigation water planning and management and provide a scientific basis to reevaluate water resources management in the terrace region under irrigated rice.  相似文献   

5.
ABSTRACT: Stable isotopes of deuterium and oxygen-18 of surface and ground water, together with anion concentrations and hydraulic gradients, were used to interpret mixing and flow in ground water impacted by artificial recharge. The surface water fraction (SWF), the percentage of surface water in the aquifer impacted via recharge, was estimated at different locations and depths using measured deuterium/hydrogen (DIH) ratios during the 1992, 1993, and 1994 recharge seasons. Recharged surface water completely displaced the ground water beneath the recharge basins from the regional water table at 7.60 m to 12.16 m below the land surface. Mixing occurred beneath the recharge structures in the lower portions of the aquifer (>12.16 m). Approximately 12 m down-gradient from the recharge basin, the deeper zone (19.15 m depth) of the primary aquifer was displaced completely by recharged surface water within 193, 45, and 55 days in 1992, 1993, and 1994, respectively. At the end of the third recharge season, recharged surface water represented ~50 percent of the water in the deeper zone of the primary aquifer ~1000 m downgradient from the recharge basin. A classic asymmetrical distribution of recharged surface water resulted from the recharge induced horizontal and vertical hydraulic gradients. The distribution and breakthrough times of recharged surface water obtained with stable isotopes concurred with those of major anions and bromide in a tracer test conducted during the 1995 recharge season. This stable isotope procedure effectively quantified mixing between surface and ground water.  相似文献   

6.
ABSTRACT: The potential for artificial ground water recharge by continuous flooding of dormant grapevines was evaluated in the San Joaquin Valley of California using the cultivar Thompson Seedless. The study was started in 1982 and was completed in 1985 after three complete flooding cycles during dormancy. An average daily rate of recharge of 80 mm/thy for a 32-day period each year was achieved through a clay loam soil. There were no adverse effects on the grapevines and yields in the flooded plots in any of the growing seasons following recharge periods. Yields were higher in the recharge plots than in the control plots in the last year of the study. We conclude that artificial ground water recharge by continuous flooding during grapevine dormancy is a viable recharge method.  相似文献   

7.
ABSTRACT: Declining ground-water levels and spring discharges have heightened water user concerns about the sustainability of the Snake River Plain aquifer in southern Idaho. Diminished recharge from surface water irrigation and increased irrigation pumping have been depleting the aquifer at a rate of about 350,000 acre-feet/year. Previously, aquifer conditions were treated as an uncontrollable consequence of weather and development activities. With increasing competition for available water, the State appears to be progressing through a three-stage process of recharge management. The first stage is that which has occurred historically, where recharge is largely an incidental effect of surface water irrigation. The second stage is the implementation of intentional recharge with little regard to identifying or maximizing benefits. Idaho has been at this stage for the past few years. The State is entering a third stage in which recharge sites will be located and designed to meet specific water user and environmental objectives. Preliminary estimates using numerical and analytical models demonstrate that managed recharge within a few miles of the river will result in short-term increases in spring discharge. More distant recharge sites are needed to provide longer-term benefits. The primary challenge facing implementation of the managed recharge program will be the balancing of economic and environmental costs and benefits and to whom they accrue.  相似文献   

8.
ABSTRACT: Field experiments were conducted from 1992 to 1995 to estimate ground water recharge rates at two sites located within a 2.7‐hectare agricultural field. The field lies in a sand plain setting in central Minnesota and is cropped continuously in field corn. The sites are located at a topographically high (upland) site and a topographically low (lowland) site in an effort to quantify the effects of depression focusing of recharge. Three site‐specific methods were used to estimate recharge rates: well hydrograph analysis, chlorofluorocarbon age dating, and an unsaturated zone water balance. All three recharge methods indicated that recharge rates at the lowland site (annual average of all methods of 29 cm) exceeded those at the upland site (annual average of 18 cm). On an annual basis, estimates by the individual methods ranged from 12 to 44 percent of precipitation at the upland site and from 21 to 83 percent at the lowland site. The difference in recharge rates between the sites is primarily attributed to depression focusing of surface water runon at the lowland site. However, two other factors were also important: the presence of thin lamellae at the upland site, and coarser textured soils below a depth of 1.5 m at the lowland site.  相似文献   

9.
ABSTRACT: This paper focuses on the development and testing of a mathematical model of an emergency ground water supply operated principally during periods of low streamflow. The process of ground water withdrawal and recharge is simulated taking account of streamflow, water demand, evapotranspiration, natural and artificial recharge and increased evapotranspiration due to artificial recharge, ground water pumpage, and streamflow contribution to pumped water. The model determines whether natural recharge is possible in less time than the return period of drought and also whether artificial recharge is needed. By simulating operation over a long period of time, the model can examine different droughts of short and long duration and can test the operating rules for ground water storage development in an area. Submodels analyze the components of the operating process including ground water flow into the stream, seepage losses, stream portion of well discharge due to induced infiltration and recharge from rainfall or water spreading. The model has been tested for areas in the humid northeastern United States.  相似文献   

10.
ABSTRACT: Water balance modeling and the analysis of stable water isotopes in ground water were conducted to aid the location of ground water discharge areas within the Goose River basin, in mid‐coastal Maine. Previous investigations of drinking water from wells in the fractured crystalline bedrock encountered persistent elevated total arsenic. Such contamination may be related to discharging ground water from fractured zones in the basin. Modeled discharge rates greater than +10 cm/yr and 18O values lighter than‐9.5 per mil VSMOW may indicate recent recharge is mixing with deeper ground water and is focused along some fractured zones in arsenic bearing crystalline rocks.  相似文献   

11.
ABSTRACT: Bringing water from Colorado River via the Central Arizona Project was perceived as the sole solution for Tucson Basin's water problem. Soon after Central Arizona Project's water arrived in Tucson in 1992, its quality provoked a quarrel over its use for potable purposes. A significant outcome of that quarrel was the enactment of the 1995 Proposition 200. The Proposition 200 precludes the use of Central Arizona Project's water for potable purposes, unless it is treated. Yet, it encourages using it for non‐potable purposes and for replenishing the Tucson aquifer through recharge. This paper examines the economic issues involved in utilizing Central Arizona Project's water for recharge. Four planning scenarios were designed to measure and compare the costs and benefits with and without Central Arizona Project's water recharge. Cost‐benefit analysis was utilized to measure recharge costs and benefits and to derive a rough estimate of cost savings from preventing land subsidence. The results indicate that the institutional requirements can be met with Central Arizona Project's water recharge. The economic benefits from reducing pumping cost and saving groundwater are not economically significant. Yet, when combining the use of Central Arizona Project's water for recharge and non‐potable purposes, it demonstrates positive net economic benefits.  相似文献   

12.
ABSTRACT: The chemical impact of urban runoff water on water quality beneath five retention/recharge basins was investigated as part of the US EPA's Nationwide Urban Runoff Program in Fresno, California. Soil water percolating through alluvium soils and the ground water at the top of the water table were sampled with ceramic/Teflon vacuum water extractors at depths up to 26 m during the two-year investigation. Inorganic and organic pollutants are present in the runoff water delivered to the basins. No significant contamination of percolating soil water or ground water underlying any of the five retention/recharge basins has occurred for constituents monitored in the study. The oldest basins was constructed in 1962. The concentration of selected trace elements in the ground water samples was similar to the levels reported in the regional ground water. None of the pesticides or other organic priority pollutants, for which water samples were analyzed, was s̊ detected except diazinon which was found in trace amounts (0.3 μg/L or less) in only three soil water samples. These results are important to the continued conservation of storm water and the development of a best management practice for storm-water management using retention/recharge basins in a semi-arid climate.  相似文献   

13.
ABSTRACT: One of the most common methods of artificial recharge to the ground water is from basins. In this paper, seven analytical solutions that describe artificial recharge from basins are presented. Most of these solutions are derived by directly solving the general partial differential equation for ground water flow. The solutions differ in that they use different boundary conditions, basin shapes, and consider the nonlinearity of the artificial recharge problem differently. Use of each analytical solution is demonstrated in this paper by application to an example problem. A comparison of each analytical solution presented in this paper was made to give suggestions on their use, their ease of implementation, and their relative agreement. Although no attempt is made in the paper to conclude which analytical solution is best for all problems, some general conclusions can be stated on the applicability of the various analytical solutions. Of the analytical solutions presented in this paper, Glovers and Hantush's solutions for rectangular recharge basins are highly recommended. Baumanns solution for a circular basin also gave fairly reliable results and is very easy to evaluate numerically.  相似文献   

14.
ABSTRACT: The geochemistry and nature of the flow of ground water not only control the supply potential but constitute clues to the whole geology of an area. A study has been made of the largest available assemblage of data from 161 wells for the Island of Montreal collected by the Geological Survey of Canada in 1951–53. Data indicated that the system is generally subartesian, flowing from the principal topographically high areas towards the shores of the Island. As the probable use is about 13% of the estimated recharge of 140 million liters per day, most wells could be supplied by local recharge. The study has confirmed the predominance of calcium bicarbonate ground water from the carbonate sequence. The waters appeared to be saturated with respect to CaCO3 in all but 10 wells. The presence of other types of waters suggests the effects of the igneous intrusions of the area, the post-glacial marine submergence and the upward movement of waters from deep sources through fault and other structural zones. Confirmation of the significant variations in chemical composition in some neighboring wells indicated the future need for repetitive sampling from specific horizons for chemical and isotopic analyses.  相似文献   

15.
ABSTRACT: Ground water flow and supply at the Whiteshell Research Area (WRA) in southeastern Manitoba and the advective movement of contaminants from a hypothetical nuclear fuel waste disposal vault to the adjacent biosphere and a nearby ground water supply well are simulated using finite-element modeling and numerical particle-tracking technique. The hypothetical vault is located at a depth of 500 m, below the water table, in low-permeability plutonic rock of the Canadian Shield. The rock mass is intersected by high-permeability fracture zones (aquifers), which also act as conduits for vault contaminants to migrate to the ground surface. The ground water resource is, therefore, limited in quantity and quality and should be explored with care. A 30 m deep well, which pumps water at a rate of 120 m3/yr from a low-dipping fracture zone, LD1, reduces natural discharge from the system to augment natural recharge. At this pumping rate, a 100 m or 200 m deep well neither reduces discharge nor induces recharge into the system. Thus, at the WRA, a 30 m deep domestic water supply well best meets the water requirements of a one-person household at the rate of 120 m3/yr. The 100 m and 200 m wells best meet the requirements of a family of six and a family of six with light irrigation, respectively, without capturing contaminants’pathways from the vault to the ground surface. By virtue of the proximity of the 200 m well intake to the hypothetical vault, this well performs best as a purge well at pumping rates of 0,000 m3/yr and greater. Finite-element modeling is useful in evaluating the water supply potential of a fractured rock environment in which a nuclear waste disposal vault is proposed to be sited.  相似文献   

16.
This study describes and demonstrates two alternate methods for evaluating the relative costs and benefits of artificial groundwater recharge using percolation ponds. The first analysis considers the benefits to be the reduction of pumping lifts and land subsidence; the second considers benefits as the alternative costs of a comparable surface delivery system. Example computations are carried out for an existing artificial recharge program in Santa Clara Valley in California. A computer groundwater model is used to estimate both the average long term and the drought period effects of artificial recharge in the study area. For the example problem, the benefits of reduced average annual pumping lifts and reduced incremental subsidence are greater than the total costs of continuing the existing artificial recharge program. Benefits for reduced subsidence are strongly dependent on initial aquifer conditions. The second analysis compares the costs of continuing the artificial recharge program with the costs of a surface system which would achieve the same hydraulic effects. Results indicate that the costs of artificial recharge are considerably smaller than the alternative costs of an equivalent surface system. In evaluating a particular program, consideration should also be given to uncertainties in future supplies and demands for water as well as to the probability of extreme events such as droughts.  相似文献   

17.
ABSTRACT: Ground water nitrate contamination and water level decline are common concern in Nebraska. Effects of artificial recharge on ground water quality and aquifer storage recovery (ASR) were studied with spreading basins constructed in the highly agricultural region of the Central Platte, Nebraska. A total of 1.10 million m3 of Platte River water recharged the aquifer through 5000 m2 of the recharge basins during 1992, 1993, and 1994. This is equivalent to the quantity needed to completely displace the ground water beneath 34 ha of the local primary aquifer with 13 m thickness and 0.25 porosity. Successful NO3-N remediation was documented beneath and downgradient of the recharge basins, where NO3-N declined from 20 to 2 mg L-1. Ground water atrazine concentrations at the site decreased from 2 to 0.2 mg L-1 due to recharge. Both NO3-N and atrazine contamination dramatically improved from concentrations exceeding the maximum contaminant levels to those of drinking water quality. The water table at the site rose rapidly in response to recharge during the early stage then leveled off as infiltration rates declined. At the end of the 1992 recharge season, the water table 12 m downgradient from the basins was elevated 1.36 m above the preproject level; however, at the end of the 1993 recharge season, any increase in the water table from artificial recharge was masked by extremely slow infiltration rates and heavy recharge from precipitation from the wettest growing season in over 100 years. The water table rose 1.37 m during the 1994 recharge season. Resultant ground water quality and ASR improvement from the artificial recharge were measured at 1000 m downgradient and 600 m upgradient from the recharge basins. Constant infiltration rates were not sustained in any of the three years, and rates always decreased with time presumably because of clogging. Scraping the basin floor increased infiltration rates. Using a pulsed recharge to create dry and wet cycles and maintaining low standing water heads in the basins appeared to reduce microbial growth, and therefore enhanced infiltration.  相似文献   

18.
Soil moisture data collected using an automated data logging system were used to estimate ground water recharge at a crude oil spill research site near Bemidji, Minnesota. Three different soil moisture probes were tested in the laboratory as well as the field conditions of limited power supply and extreme weather typical of northern Minnesota: a self‐contained reflectometer probe, and two time domain reflectometry (TDR) probes, 30 and 50 cm long. Recharge was estimated using an unsaturated zone water balance method. Recharge estimates for 1999 using the laboratory calibrations were 13 to 30 percent greater than estimates based on the factory calibrations. Recharge indicated by the self‐contained probes was 170 percent to 210 percent greater than the estimates for the TDR probes regardless of calibration method. Results indicate that the anomalously large recharge estimates for the self‐contained probes are not the result of inaccurate measurements of volumetric moisture content, but result from the presence of crude oil, or borehole leakage. Of the probes tested, the 50 cm long TDR probe yielded recharge estimates that compared most favorably to estimates based on a method utilizing water table fluctuations. Recharge rates for this probe represented 24 to 27 percent of 1999 precipitation. Recharge based on the 30 cm long horizontal TDR probes was 29 to 37 percent of 1999 precipitation. By comparison, recharge based on the water table fluctuation method represented about 29 percent of precipitation.  相似文献   

19.
ABSTRACT: Under Colorado's appropriative water right system, withdrawals by junior ground water rights must be curtailed to protect senior surface water appropriators sharing the same river system unless the ground water users replace the amount of their injury to the river under an approved plan for augmentation. Compensation of such injury with surface water may not only be expensive but unreliable in dry years. As an alternative, the curtailment of pumping may be obviated by recharging unused surface water into the aquifer when available and withdrawing it when needed. In order to manage such an operation, a practical tool is required to accurately determine that portion of the recharge water that does not return to the river before pumping for irrigation. A digital model was used for this purpose in a demonstration recharge project located in the South Platte River basin in northeastern Colorado. This paper summarizes the experiences gained from this project, the results of the digital model, the economic value of recharge, and the feasibility of the operation. It was determined through the use of the digital model that, with the given conditions in the area, 77 percent of the recharged water remained available for pumping. Economic analyses showed that water could be recharged inexpensively averaging about two dollars per acre foot.  相似文献   

20.
ABSTRACT Raw sewage was metered into a newly-constructed lagoon of the Pima County Department of Sanitation, Tucson, Arizona. Seepage losses were calculated from data on inflow, evaporation and change in storage. Water samples were obtained from shallow suction cups, a 40 ft. and a 60 ft. PVC well and a 100 ft. access tube, all located inside the lagoon. Samples from these wells, together with water samples from the lagoon, were examined for conform organisms and various physical and chemical constituents. Of special concern were transformations in nitrogen. Estimated seepage rates in the lagoon during inundation ranged from 0.20 ft. per day to 0.10 ft. per day. Water level observations in wells reflected the percolation of effluent to the water table, 70 ft. below land surface. Initially, the nitrate ion levels in the suction cup samples were high, manifesting the leaching of indigenous soil nitrogen. With the onset of anaerobic conditions at the base of the lagoon, nitrification was inhibited at the soil surface and ammonia became the predominant form of nitrogen in the soil solution. Sorption of ammonium ion appeared to occur on clay particles in a soil zone of high cation exchange capacity. There were no undesirable microbial or chemical effects of recharge from lagoon seepage on native groundwater quality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号