首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In order to get more information about potential health hazards due to indoor air PCBs the present study investigated the PCB indoor concentration in schools as well as the blood levels of 6 PCB-indicator congeners in teachers from these schools. 151 teachers (78 male and 73 female; mean age 48 years) from 3 contaminated and 2 control schools participated in the study. Maximal indoor air values for total PCBs (6 PCB-indicator congeners times 5) in schools ranged from 1587 to 10655 ng/m3. Blood analyses indicated an increase in mean PCB 28 level from 0.036 (control group) to 0.098 microg/l in teachers from a school with heavy contamination of low chlorinated PCB. But there was no significant increase of PCB 138, 153 and 180 in blood above the normal background concentrations in any of the contaminated schools (mean values of all groups: PCB 138 = 0.66, 153 = 0.95, 180 = 0.70 microg/l blood). The results of blood analyses and additional toxicokinetic calculations suggested that inhalative PCB-uptake in the most contaminated schools caused a minor increase above mean background-PCB concentrations in blood. In conclusion, despite high PCB indoor air levels in schools, there was only a moderate increase in blood concentrations of teachers, mainly due to congeners with low chlorination (PCB 28 to PCB 101).  相似文献   

2.
In 2003, concentrations of altogether 17 PCDD/Fs congeners and 12 non-ortho and mono-ortho dioxin-like PCBs were measured in the blood of 60 randomly selected adults who lived in three settlements surrounding a chemical plant that had been producing chlorinated herbicides (mainly HCHs, HCB, pentachlorophenole, 2,4,5-T) in the 1960's; subjects consuming home-produced animal foods were chosen. Twenty blood donors with similar characteristics from the locality with about 80 km distance were used as control subjects. The factors that influenced the dioxin levels were investigated on the basis of a questionnaire. The aim of our study was to find out whether the residents living in the surroundings of the chemical plant are at a greater exposure risk than the controls. To calculate TEQ values, WHO-TEFs were used. The concentrations of four PCDD and six PCDF congeners were below the LOD in more than 50% of samples. Significantly higher WHO-TEQ levels (p<0.05) were found for PCDDs, PCDFs, or PCBs in all three followed up groups compared with controls. The geometric means of the total TEQ values for PCDD/F/PCBs were 43.8, 50.2, and 40.0 pg/g fat compared to 23.2 pg/g fat in the control. The percentages of TEQ due to the measured congeners in exposed groups were 9-10.3% for PCDDs, 20.5-26.9% for PCDFs, 19.2-23.1% for coplanar and 43.6-47.2% for mono-ortho PCBs. In control, the percentage of TEQ was 11.6, 26.7, 24.1, and 37.5%. PCBs, predominantly PCB156, followed by PCB126 contributed 60 to 70% of the total TEQ value. Positive correlation of the PCDD/PCDF/PCB blood levels with age and with consumption of locally produced eggs was found.  相似文献   

3.
The aim of this study was to determine a new spectrum of substances that will be selected for future breast milk monitoring in Bavaria, Germany. Up to now, the analysis of breast milk in Bavaria was limited to selected organochlorine pesticides (OCP) and polychlorinated biphenyls (PCB). Information on background levels of toxicologically interesting substances, such as dioxins and dioxin-like polychlorinated biphenyls (dl-PCB) or on flame retardants, such as polybrominated diphenyl ethers (PBDE) are very limited or not available for Bavaria. We present here levels on OCP, some nitro musks, indicator PCB, polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and dl-PCB concentrations in breast milk collected at 12 weeks post-partum of 43 primiparous mothers living in Bavaria. The average concentrations of PCDD, PCDF and dl-PCB were 4.98, 4.93 and 9.92 pg WHO-TEQ g(-1) lipid, respectively. The mean contribution of PCDD, PCDF, non-ortho and mono-ortho PCB to the total WHO-TEQ is consistently about 25% each. Furthermore the concentration on PBDE in breast milk at two sampling points, 12 weeks and 16 weeks after delivery, were determined. Overall, 19 PBDE congeners were analysed, however the level of 12 PBDE congeners were below the limit of detection. BDE-153 and BDE-47 were the predominant congeners accounting for about 66% of the total PBDE. The means of the total concentrations of PBDE (five congeners) at the first and second sampling point were 1.90 and 2.03 ng g(-1) lipid, respectively. Based on our results the overall concentrations of the analysed substances in milk samples from Bavaria are consistent with the levels of breast milk samples of other European countries reflecting the low background body burden of these compounds.  相似文献   

4.
Data on dioxin-like PCB in indoor air of buildings with PCB-containing materials and on possible correlation between toxicity equivalent concentrations (TEQ) and levels of non-dioxin-like standard PCB is sparse. As part of a larger survey on indoor-air contamination with PCB, the connection between the concentration of standard PCB congeners and the dioxin-like toxicity expressed as TEQ was investigated. Indoor air samples (n=8) were collected in four public buildings with known PCB sources and total PCB levels in the range from 715 to 2250 ng/m3 and analyzed for the six non-dioxin-like standard PCB (congeners 28, 52, 101, 138, 153, 180), the twelve dioxin-like PCB congeners according to WHO and the 17 2,3,7,8-substituted PCDD/PCDF congeners. In three buildings where PCB were used as flame retardant coatings of acoustic ceiling tiles, PCB 101 had the maximum level among the six standard PCB, while in the building with permanent elastic sealants as PCB source, congeners 28 and 52 dominated the pattern by far. In the case of permanent elastic sealants as PCB source (n=3) a total PCB concentration of 1000 ng/m3 corresponded to a total TEQ level of 0.3-0.6 pg/m3. In contrast, in rooms with acoustic ceiling tiles as PCB source, 1.8-4.7 pg TEQ/m3 per 1000 ng total PCB/m3 were found. Linear regression analysis between PCB and TEQ indicated that PCB 118 might be used to calculate the total TEQ of dioxin-like PCB and PCDD/PCDF. By means of such a correlation it is possible to estimate TEQ by extrapolation from the results of less sophisticated analytical methods. It is tentatively recommended to use PCB 118 for screening purposes or re-evaluation of standard PCB indoor-air measurements. If only the six non-dioxin-like PCB standard congeners are available, a regression algorithm using the sum of PCB 101, 138, 153 and 180 might be used instead.  相似文献   

5.
Todaka T  Hirakawa H  Hori T  Tobiishi K  Iida T  Furue M 《Chemosphere》2007,66(10):1983-1989
We measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), non-ortho polychlorinated biphenyls (non-ortho PCBs) and mono-ortho polychlorinated biphenyls (mono-ortho PCBs) in blood collected from 279 Yusho patients living in Japan, 92 Yusho-suspected persons living in Japan and 127 normal controls living in Fukuoka Prefecture, and compared among the groups in terms the concentrations of these compounds. The total toxic equivalents (TEQ) concentrations of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs in the bloods of Yusho patients and Yusho-suspected persons were 161.4 and 51.2 pg TEQ/g lipid, respectively and were about 3.5 and 1.1 times higher than those of normal controls, respectively. Although the TEQ concentrations of PCDDs, non-ortho PCBs, and mono-ortho PCBs among Yusho patients, Yusho-suspected persons and normal controls were nearly the same, the PCDFs levels of Yusho patients were significantly higher than those of Yusho-suspected persons and about 10.3 times higher than those of normal controls. In Yusho patients, PCDFs contributed about 65% to the total TEQ concentration. Among the PCDFs congeners for Yusho patients, the concentration of 2,3,4,7,8-pentachlorodibenzofuran (PeCDF) was about 11.3 times higher than that of normal controls. These findings indicated that Yusho patients even now, more than 34 years after the outbreak of Yusho, have much higher blood levels of 2,3,4,7,8-PeCDF in general than do unaffected persons.  相似文献   

6.
Ishaq R  Näf C  Zebühr Y  Broman D  Järnberg U 《Chemosphere》2003,50(9):1131-1150
Methodology for the determination of biologically active polychlorinated biphenyls (PCBs), non-ortho PCBs, polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polycyclic aromatic hydrocarbons (PAHs) was used to investigate concentrations and patterns of certain chlorinated PAH (Cl-PAH) in source related samples using synthetic reference mixtures. Thus, in addition to the above mentioned compounds, mono-heptachlorosubstituted fluorenes, phenanthrenes/anthracenes and pyrenes/fluoranthenes (Cl-PAHs) were measured in vapour and particulate air samples from urban road tunnels, samples of settling particulate matter (SPM), and in bottom sediment samples from two point source locations (pulp and paper, and Mg-plant/Fe-Mn-smelter/chlor-alkali) and in the Baltic Sea. Concentrations in air samples followed: PAHs>PCBs>PCNs>non-ortho PCBs or Cl-PAHs>PCDD/Fs. SPM samples collected at increasing distance to the urban area of Stockholm showed: PAHs>PCBs>PCNs>PCDD/Fs>non-ortho PCBs or Cl-PAHs. For all compound groups there was a tenfold (Cl-PAHs fivefold) concentration decrease in SPM samples from highest levels in the urban water area to lowest levels at a distance of 26 km from city centre. PCB profiles of SPM showed similarities with combined profiles of Aroclor 1242 and 1254. PCN profiles of SPM showed similarities with combined profiles of Halowax 1099 and 1014. A correlation with concentration of all tested Cl-PAH and their corresponding parent PAH was found only for Cl-fluorene.  相似文献   

7.
In an attempt to evaluate the background levels of PCDDs, PCDFs and non-ortho PCBs in people living in Madrid (Spain), blood serum samples had been analyzed PCDD, PCDF and coplanar PCB levels from non exposed individuals are reported in this study. Average levels found were 515.29 ppt for total PCDDs, 66.73 ppt for total PCDFs and 85.47 ppt for non-ortho PCBs on a lipid weight basis Calculated I-TEQ values were 8.78 ppt for PCDDs, 6.96 for PCDFs and 7.03 for coplanar PCBs on a lipid weight basis.  相似文献   

8.
Despite their environmental importance, there are still relatively few historical studies of the environmental occurrence of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), especially in middle Europe. Trends in PCBs and PCDD/Fs were, therefore, assessed in lake sediments of the Grosser Arbersee over the past 130 years (1860-1990). Ballschmiter-PCB concentrations (congeners # 28, 52, 101, 138, 153, 180) increased between 1946 and 1972 from 4.2 to 32.0 microg kg(-1) dry wt, but have since decreased to 25.6 microg kg(-1) dry wt. High chlorinated PCB congeners reached their maxima earlier (1968-1972) than low chlorinated congeners (1985-1991). These trends were consistent with patterns expected from the production and use of PCBs and their precursors. PCDD/F concentrations increased between 1950 from 0.6 microg kg(-1) dry wt to 2.3 microg kg(-1) dry wt in 1977, falling to 1.7 microg kg(-1) dry wt by 1993. PCDF concentrations exceeded those of PCDD until 1968, but afterwards PCDDs (especially OCDD) were predominant. These patterns suggest that domestic heating and waste combustion were the most likely sources, but pollution from local industries, such as metal smelting and glass production, might also have been involved. The data provide a valuable case study from central Europe which confirms the overall declining trends of PCB and PCDD/F contamination shown elsewhere.  相似文献   

9.
Hsu JF  Guo YL  Yang SY  Liao PC 《Chemosphere》2005,61(9):1231-1243
In 1978-1979, a mass poisoning occurred in central Taiwan from rice-bran oil contaminated by heat-degraded PCBs was later called the Yucheng (oil disease in Chinese). Only a few studies have so far investigated the levels of specific polychlorinated biphenyl (PCB) or polychlorinated dibenzodioxin/furan (PCDD/F) congeners in the Yucheng victims. This study aimed to investigate the serum residual levels of thirty-three PCBs and seventeen 2,3,7,8-substituted PCDD/F congeners in the Yucheng victims 15 years after the exposure. Forty-one blood samples were collected from individual Yucheng victims in 1994-1995. The mean levels of total 33 PCBs and 17 PCDD/Fs were 2468 ng/g lipid (13.3 ng/g sample) and 6550 pg/g lipid (30.9 pg/g sample) respectively. The higher levels were found in PCBs #99, #138, #153, #156, #170, #179, and #180 among 33 PCB congeners, while 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, and OCDD had the higher concentrations among 17 PCDD/F congeners. The total TEQ was contributed in decreasing order by 10 PCDFs (44%), three non-ortho-PCBs (24%), six mono-ortho-PCBs (20%), and seven PCDDs (12%). The mean total PCB levels and TEQ value of the 17 PCDD/Fs in the Yucheng victims 15 years after the toxic exposure were still 9 and 46 times higher than those in the general population in Taiwan. Principle component analysis (PCA) indicated that seven PCB congeners, PCBs #99, #138, #153, #156, #170, #179, and #180, accounted for 73% of the total variances in PCBs. On the other hand, six PCDD/F congeners, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 1,2,3,6,7,8-HxCDD, 1,2,3,4,6,7,8-HpCDF, and OCDD, accounted for 97% of the total variances in PCDD/Fs. In addition, PCA revealed that at least three characteristic patterns of congener profiles for PCBs were observed among the Yucheng victims. Similar trend was also observed for PCDD/Fs. These patterns may reflect distinctive exposure scenarios and/or different metabolizing capabilities among the Yucheng victims. We suggest that these patterns, in contrast to total PCB and PCDD/F levels, may be valuable for the future epidemiologic studies when linking exposure with specific health effect.  相似文献   

10.
Congener specific polychlorinated biphenyl (PCB) data from the stack gas of nine Korean municipal waste incinerators was used to determine characteristic congener patterns of emitted PCBs. Principal component analysis revealed three classes of incinerators according to their pattern of PCB congener emissions: those resembling the background sampling material; those producing large quantities of a few tetra-chlorinated congeners; those producing large proportions of mono (MO-) and non-ortho (NO-) congeners relative to di-ortho (DO-) levels. Also, correlations between individual PCB congeners and polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) were discovered for several NO-PCBs and tetra and penta chlorinated PCDFs. Full PCB congener data is presented along with operating conditions for each incinerator.  相似文献   

11.
In 1999, the FLEHS was set by the Flemish Ministry of Health, Belgium to assess pollutant concentrations and related health effect biomarkers in humans living in Flanders. Concentrations of selected organochlorine pesticides, polychlorinated biphenyls (PCB) and polychlorinated dibenzo-p-dioxins (PCDD) and furans (PCDF) were measured by gas chromatography-mass spectrometry and Chemical-Activated LUciferase gene eXpression (CALUX) bioassay in 47 serum pools of 200 women between 50 and 65 years living in two areas of Flanders. Correlation between TEQ values of different groups of compounds were computed in these pool results and it was found that total toxic equivalencies (TEQs) correlated well with the values of the groups of contributing compounds: mono-ortho PCBs (r = 0.77), non-ortho PCBs (r = 0.65) and PCDD/Fs (r = 0.88). The total TEQ was lower correlated to the CALUX-TEQ (r = 0.57). When calculating associations between those classes of compounds in the two studied regions separately, they were all higher correlated in the urban area compared to the more rural region. High correlation coefficients (r > 0.80) were also calculated between individual compounds and groups of compounds. It was suggested that in this studied background-exposed population, some compounds could be good predictors for a group: e.g. PCB 153 for indicator and total PCBs, PCB 118 for total PCB TEQ, PCB 156 for mono-ortho PCB-TEQs and total TEQ, 2,3,4,7,8-P5CDF for PCDD/F TEQs and total TEQs. This means that in pooled serum samples correlations between persistent organochlorine compounds are as strong as for individual POP measurements observed in earlier studies.  相似文献   

12.
Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate. The PCBtot levels in the air of the contaminated section were 168-3843 ng m−3 (mean: 1030 ng m−3), while the mean levels in the reference apartments were 6.03 ng m−3. The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221 680 mg kg−1. Principal component analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e.g. for PCB 28air and 28seal (p = 0.04) and for PCB 28air and 52air, 52seal. However, no correlation was observed between the lower chlorinated congeners and the sums of PCB (∑PCB6 or ∑PCB24) or the higher chlorinated congeners. Analysis of air concentrations in relation to questionnaire data indicated that the indoor air levels could be reduced by increased cleaning and airing frequencies.  相似文献   

13.
Differential uptake for dioxin-like compounds by zucchini subspecies   总被引:1,自引:0,他引:1  
Inui H  Wakai T  Gion K  Kim YS  Eun H 《Chemosphere》2008,73(10):1602-1607
The zucchini (Cucurbita pepo) cultivars 'Patty Green', 'Black Beauty', and 'Gold Rush' were cultivated on weathered dioxin-contaminated soil in pots, and concentrations of the 29 dioxin-like compounds that were assigned WHO-TEFs, three non-toxic polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), and two non-dioxin-like polychlorinated biphenyls (PCBs) were analyzed. Toxic equivalent (TEQ) values accumulated in 'Black Beauty' and 'Gold Rush' were about 180 times higher than those in 'Patty Green'. The bioconcentration factor (BCF) based on total mass concentration of the twelve dioxin-like PCBs was higher than those of the seven PCDDs and ten PCDFs in all the cultivars. The BCFs for PCDD and PCDF congeners were negatively correlated with octanol-water partition coefficients in all the plants. No correlations were observed in PCB congeners in the high accumulators, although in 'Patty Green' the BCFs for PCB congeners were significantly correlated with octanol-water partition coefficients. Our findings suggest that the high accumulators had unknown, unique mechanisms for uptake of PCBs, whereas PCDDs and PCDFs were absorbed based on their physicochemical properties.  相似文献   

14.
Kim M  Kim S  Yun S  Lee M  Cho B  Park J  Son S  Kim O 《Chemosphere》2004,54(10):1533-1538
The risk assessment of polychlorinated biphenyls (PCBs) is difficult since complex congeners were used in many industrial applications for a long period of time and the residue monitoring in foods of animal origin and the environment were not established in comparable systems. The relationships of determined concentrations in indicator PCB congeners (mono- and di-ortho PCBs) and coplanar PCB congeners (non-ortho PCBs) in livestock products are presented in this study. The concentrations of seven indicator PCBs were compared with three coplanar PCBs in beef, pork, and chicken fat. Distributions of concentration for the indicator PCBs in three different animal species were similar except for that of PCB-118 (2,3',4,4',5-pentachlorobiphenyl) in pork fat. The congeners with the highest concentration were PCB-138 (2,2',3,4,4',5'-hexachlorobiphenyl) in beef and pork fat and PCB-28 (2,4,4'-trichlorobiphenyl) in chicken fat. The bioaccumulation and metabolism of PCBs in animal species represent different congener profiles in livestock products. The percentage of the total concentration of three coplanar PCBs was about 2% of the total concentration of the seven indicator PCBs. Relatively high concentration of mono-ortho and di-ortho PCBs in fat samples of livestock products may be calculated with the concentration of coplanar PCBs that can be usually determined on a sequential procedure with dioxin analysis. Therefore, the relationship of the amounts between seven indicator PCBs and three coplanar PCBs may be useful to derive the composition and level of contaminants in beef, pork, and chicken.  相似文献   

15.
Hirako M 《Chemosphere》2008,71(2):219-226
To determine the distribution of persistent organochlorine compounds in beef cattle, concentrations of 2,3,7,8-substituted PCDDs, PCDFs and dioxin-like PCBs were measured in the blood, testes and adipose tissue of four two-month-old Japanese Black calves. Of 29 congeners analyzed, 19, 20 and 28 were detected in the blood, testes and adipose tissue, respectively, of three or all calves. Total toxic equivalents (TEQs) were similar in the testes and adipose tissue, and approximately two times higher than in the blood on a lipid weight basis (P<0.05). More PCDDs and PCDFs had accumulated in the testes than in adipose tissue (P<0.01), but more dioxin-like PCBs were found in adipose tissue than in the testes (P<0.0001). Accumulation patterns in the testes and adipose tissue varied among the congeners of PCDD and PCDF, whereas the patterns were similar in dioxin-like PCBs. In particular, highly substituted PCDD congeners were detected at high concentrations in the testes but at lower concentrations in adipose tissue compared with other congeners. By contrast, accumulation levels of highly substituted PCDFs were lower in both those tissues than the other congeners. In conclusion, it was demonstrated that PCDDs, PCDFs and dioxin-like PCBs leave the circulation and accumulate in the testes and adipose tissue in bovine calves. It was suggested that congeners of PCDD, especially highly substituted PCDDs, and PCDFs have a tendency to accumulate in the testis and dioxin-like PCB congeners accumulate readily in adipose tissue.  相似文献   

16.
Chi KH  Chang MB  Kao SJ 《Chemosphere》2007,68(9):1733-1740
Polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF) and polychlorinated biphenyl (PCB) concentrations were analyzed at 1-2cm intervals in a sediment core collected from a reservoir in Northern Taiwan to evaluate the organic pollution history. The highest PCDD/F (14.4ng TEQ/kg d.w.) and PCB (0.261ng TEQ(WHO)/kg d.w.) concentrations were determined at 13-15cm (estimated year: 1992). The ages of the levels of sediment core were estimated from the sedimentation rate. Analysis results demonstrate that the PCDD/F concentration of the sediment core measured in the reservoir reached their peak when the municipal waste incinerators (MWIs) in the area started to operate. Furthermore, the decrease in sediment core PCDD/F concentration is related to the time of enforcement of the PCDD/F emission limit set by the Environmental Protection Administration (EPA) in Taiwan. Significant distribution of OCDD in homologue profiles was noted in archived soil samples in Taiwan in which the major input of PCDD/Fs was thought to be atmospheric. Major PCB congeners found in the sediment core were the major components of the commercial PCB products. Input fluxes of PCDD/Fs (5.75-158ng-I-TEQ/m(2)-yr) and PCBs (0.248-3.71ng TEQ(WHO)/m(2)yr) into the reservoir of interest are also calculated from the concentration and sedimentation rate of the sediment. The results reveal that considerable amounts of PCDD/Fs and PCBs were carried into the reservoir of interest in the flood stage but not during normal stage.  相似文献   

17.
There is no previous report from Turkey on chemically determined polychlorinated dibenzo-para-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (PCBs) in human tissues expressed as World Health Organization (WHO) toxic equivalents (TEQs). The objective of this study was to determine the occurrence of PCDDs/Fs, and dioxin-like PCBs in the general adult Turkish population. For this reason we measured adipose tissue concentrations of PCDDs/Fs and dioxin-like PCBs in 23 Turkish men living in Ankara,Turkey in 2004. PCDD/F concentrations ranged between 3.2 and 19.7 pg WHO-TEQ/g fat (5.34 and 42.7 WHO-TEQ/g fat, respectively, including dioxin-like PCBs). The mean concentrations of WHO(PCDD/F)-TEQ and WHO(PCB)-TEQ were 9.2 and 6.67 pg/g on a lipid basis , respectively. Samples were analyzed for PCDD/F and twelve dioxin-like PCB congeners using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). This study is very important since it is the first report on PCDDs/Fs and dioxin-like PCB contamination in human adipose tissue from Turkey.  相似文献   

18.
Farmed fish can be exposed to persistent organic contaminants--such as polychlorinated biphenyls (PCBs), dibenzodioxins (PCDDs), and dibenzofurans (PCDFs)--via feed, this eventually resulting in accumulation levels of health concern. To study the correlation between feed contamination, chemical accumulation in fish muscle (fillet), and chemical depletion, an all-vegetal base (or blank) feed was prepared and fortified with a commercial PCB mixture (Aroclor 1254) and six PCDD and PCDF congeners (namely, 2,3,7,8-T(4)CDD, 2,3,7,8-T(4)CDF, 1,2,3,7,8-P(5)CDD, 1,2,3,7,8-P(5)CDF, O(8)CDD, and O(8)CDF) to reproduce realistic low, medium, and high contamination levels. After a 1-month exposure, trout (Oncorhynchus mykiss) were fed with the blank feed and sacrificed every 0.5 months over a 3-month period from exposure end; fillet specimens were sampled at each time. In all groups, the average fish weight increased linearly through the observation period. The chemical diminishing patterns observed were due to the combined effect of clearance and growth dilution: for 10 PCB and four PCDD and PCDF congeners, patterns were described with an empirical one-compartment (fish muscle) model. The canonical pseudo-first-order kinetic equation used was also modified into the form C=[C(0)exp(-k(C)t)] (m(W)t+1)(-1) to distinguish between the contributions to depletion from clearance, exp(-k(C)t), and growth dilution, (m(W)t+1)(-1). Most mean clearance half-life (HL(C)) estimates appear to be greater than 4 months, in a number of cases reaching magnitudes well over 10 months or even negative, thus clearly indicating a non-negligible contribution from a second compartment. Based on means and their 95% confidence intervals, the depletion HL(D) estimates of the 14 selected congeners seem to be comprised between 1.2-3.4 and 1.0-5.0 months, respectively: these values, accounting for both clearance and growth dilution, provide an indication of the relevance of a blank feed as a management option to reduce the overall PCB, PCDD, and PCDF content in farmed trout. Due to a lack of bioaccumulation, O(8)CDD and O(8)CDF yielded no results for evaluation, whereas for many PCB congeners results were insufficient for empirical modelling.  相似文献   

19.
Isomer specific concentrations of individual polychlorinated biphenyls (PCBs) including toxic non-ortho (IUPAC 77, 126, 169), mono-ortho (105, 118, 156) and di-ortho (137, 138, 153, 180) coplanar congeners were determined in the blubber of 40 Baikal seals (Phoca sibirica) and as their fish diet collected from Lake Baikal, Siberia. Residue levels of total PCBs in Baikal seals were noticeably high and comparable to those reported for seals from the North Sea, suggesting the recent usage of this compound in the watershed of Lake Baikal. Non-, mono-, and di-ortho coplanar congeners were also detected in Baikal seals and fish. An approach to estimate bioaccumulation profiles of PCB congeners revealed that the non-ortho PCBs, IUPAC 77, 126 and 169 seemed to be less persistent than other congeners. Furthermore, selective biotransformation of PCB congeners having either meta-para vicinal H atoms or both adjacent chlorinated meta-para and ortho-meta positions has been suggested. Comparison of 2,3,7,8-TCDD toxic equivalents (TEQ) of non-, mono- and di-ortho coplanar congeners in Baikal seals with those for other marine mammals suggested higher enrichment of mono-ortho congeners, particularly IUPAC 105 and 118, which contributed significantly to the total TEQs in Baikal seals. Results imply that the TCDD-like toxicity is relatively serious in Baikal seals, because of the enrichment of these toxic PCB congeners in tissues.  相似文献   

20.
Ogura I  Masunaga S  Nakanishi J 《Chemosphere》2001,44(6):1473-1487
The atmospheric bulk (dry and wet) deposition of dioxins was investigated at four locations (Tokyo, Yokohama, Tsukuba, and Tanzawa) in the Kanto region (in Japan) over one year using a stainless-steel pot. Annual average polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/PCDF) deposition fluxes were estimated to be from 450 to 1300 ng/m2/yr, and the annual average TEQ fluxes from 5.7 to 17 ng-TEQ/m2/yr at the four locations. The PCDD/PCDF deposition flux was higher in winter than in summer. The deposition flux could be related to ambient temperature, particularly for less chlorinated PCDDs/PCDFs, while the deposition flux is not necessarily related to the amount of precipitation. The PCDD/PCDF deposition flux increased as the particle deposition flux increased, for the winter samples. Based on the ratio of the PCDD/PCDF deposition fluxes to the particle deposition fluxes, the contribution of the reentrainment of soil particles to the TEQ of PCDD/PCDF deposition was considered to be negligible in this region. Based on the air concentrations monitored near our deposition sampling points by the municipalities, the ratio of the annual deposition flux to the annual average air concentration was roughly estimated to be 0.082 cm/s. The range of deposition flux in the Kanto region was estimated to be from 1.5 to 31 (median: 9.8) ng-TEQ/m2/yr based on the range of air concentration data measured by the municipalities. The total annual deposition flux in the entire Kanto region was estimated to range from 50 to 900 g-TEQ/yr (median 320 g-TEQ/yr). This estimated flux was of the same order as the sum of estimated emissions from municipal solid waste incinerators and industrial waste incinerators in the Kanto region. The contributions of dioxin-like PCBs in Yokohama, Tsukuba, and Tanzawa depositions were less than 10% of the total TEQ; however, in Tokyo it was almost equal to or more than 50%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号