首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 187 毫秒
1.
采用砂滤-臭氧-生物活性炭工艺在北京市某污水处理厂开展了以污水再生回用为目的的城市污水深度处理中试研究。在臭氧消耗量5mg/L,接触时间20min,生物活性炭空床停留时间(EBCT)为20min的条件下,出水浊度为1.5NTU左右,色度接近0,UV254从0.162cm^-1降低到0.08cm^-1,DOC和CODMn分别从10.1mg/L和12.8mg/L降低到6mg/L左右。由于对生物活性炭柱进行了曝气供氧,NH4^- N从40mg/L降低到5mg/L左右。  相似文献   

2.
臭氧-曝气生物滤池深度处理印染制革园区废水   总被引:3,自引:0,他引:3  
针对浙江省某印染制革园区污水处理厂二级生化出水,开展了处理规模36~120 t/d的臭氧-曝气生物滤池中试研究,对臭氧预处理进行优化,考察了臭氧预处理优化后与不同填料BAF组合对污染物的去除情况。结果表明,当臭氧预处理条件为投加量25 mg/L,三点投加且投加比为6:3:1,臭氧接触时间为42 min时,处理效果较好且最经济;在此臭氧预处理条件下,臭氧-活性炭BAF的出水COD能稳定在50 mg/L,色度稳定在5度,满足《城镇污水厂污染物排放标准》(GB 18918-2002)中的一级B排放要求;臭氧-混合填料BAF的出水COD和色度也能基本达到一级B排放要求;而臭氧-陶粒BAF出水COD和色度都未能达到一级B排放要求。  相似文献   

3.
混凝-IBAC深度处理焦化废水的试验研究   总被引:4,自引:1,他引:3  
以哈尔滨某气化厂焦化废水为目标,探讨混凝-固定化生物活性炭(IBAC)工艺对哈尔滨气化厂焦化废水进行深度处理的净化效能及其可行性.采用筛选、驯化的脱酚菌,对活性炭(GAC)进行固定,使之形成固定化生物活性炭.当该工艺进水COD<800 mg/L时,出水COD在100 mg/L以下,平均去除率在80%左右;当进水总酚在200 mg/L以下时,出水的总酚含量基本在20 mg/L以下;当进水氨氮浓度在75 mg/L以下时,出水氨氮浓度在25 mg/L以下.焦化废水中各污染物指标经混凝-IBAC工艺深度处理后可达污水综合排放标准(GB 8978-1996)的二级标准.  相似文献   

4.
三维电极-好氧生物法联合处理酸性染料废水模拟研究   总被引:1,自引:0,他引:1  
采用电解-好氧生物法联合处理酸性大红G模拟废水,三维电解反应器填料为活性炭与玻璃珠混合物,平板电极材料为石墨,通过正交实验确定的最佳实验条件为:电解时间150min,活性炭/玻璃珠体积比为2:1,槽电压20V、pH为5、Na2SO4投加量1.5g/L,进水初始浓度2000mg/L。此时COD去除率及色度去除率分别可达49.78%和81.45%,废水BOD,/COD由0.12提高到0.42。电解后的废水采用生物接触氧化法处理12h后,出水COD为48mg/L,色度120倍,达到综合污水排放二级标准。  相似文献   

5.
气水比对曝气生物活性炭处理原水的影响   总被引:1,自引:1,他引:0  
廖伟  邹亮  陆少鸣 《环境工程学报》2012,6(4):1188-1192
针对从臭氧-活性炭工艺中开发出来的预臭氧-曝气生物活性炭,在不同气水比工况下进行实验,分析了不同气水比对曝气生物活性炭处理微污染原水的影响与作用。结果表明:在滤速为8~12 m/h,空床接触时间为11.5~15.4 min,装填密度为510 g/L条件下,不同气水比对去除氨氮的影响大于对CODMn的影响。气水比为0.3∶1时,对氨氮浓度为1.65~2.10 mg/L范围的进水平均去除率为81.9%,亚硝酸盐氮平均积累率为1.4%,CODMn去除率为70.6%。当气水比逐渐增加时,氨氮平均去除率有所提高,亚硝酸盐氮积累率则有所下降,对较低浓度的CODMn影响不大。  相似文献   

6.
采用臭氧/活性炭联合工艺对焦化废水A2/O出水进行深度处理。考察了溶液初始pH值、臭氧投加量、活性炭投加量及使用次数、反应时间对焦化废水处理效果的影响。实验结果表明,活性炭的使用可显著提高臭氧对焦化废水COD的去除率,在溶液初始pH值为10.25、臭氧投加量为7.5 mg/min、活性炭投加量50 g/L、反应时间为30 min条件下,COD去除率达到73.51%。同时,在活性炭重复使用10次时,COD去除率为70.85%,仅降低了2.66%。  相似文献   

7.
考虑到突发性水污染中有毒有机物的高频现率,选用苯酚为有毒有机物代表,通过模拟突发苯酚污染的情况,研究了臭氧-生物活性炭(O3-BAC)工艺对苯酚污染的应急处理效果,并且分析了工程中实际环境因素如空床接触时间(EBCT)、pH值对该应急能力的影响.研究表明,在突发性苯酚污染的应急处理中,0.6 mg/L的臭氧可将初始苯酚浓度5倍于达标浓度的进水处理至饮用水达标浓度,即低于0.002 mg/L,15.3 min的空床接触时间是判定其是否为该应急过程的关键因素的分界点,为了取得较好的应急效果,可适当提高进水pH值.  相似文献   

8.
采取固定床连续式水处理方式,实验研究了在固体催化剂作用下微量臭氧催化氧化深度处理地下煤气化废水的效果.结果表明,当处理COD为300 mg,/L左右的该类型废水时,加入微量臭氧,水处理装置COD去除率提高了45%,平均1 mg的臭氧处理了2.4 mg有机物;当废水COD为200 mg/L左右,进水速度为1 L/h时,最佳臭氧投加量为每升废水20 mg左右的臭氧,此时气水比为15:1左右;同时实验发现,不同COD的废水色度均可以被有效去除.通过与其他类似的实验研究比较发现,微量臭氧催化氧化技术具有成本优势.  相似文献   

9.
为了确定3种工艺:混凝-沉淀-砂滤-后臭氧-生物活性炭滤池(工艺Ⅰ)、预臭氧-混凝-沉淀-砂滤-生物活性炭滤池(工艺Ⅱ)和预臭氧-混凝-沉淀-砂滤-后臭氧-生物活性炭滤池(工艺Ⅲ)中臭氧的最优投加量和投加方式,采用动态实验进行了不同工况下有机物的去除效果研究,并从臭氧利用率的角度对3种工艺进行比较。同时,为了明晰工艺Ⅲ中各个单元对有机物的去除机制,研究了各处理阶段的有机物分子质量分布情况。结果表明,工艺Ⅲ在最佳工况下出水水质最优,但单位臭氧利用率较低,单位臭氧去除CODMn、TOC分别为0.92 mg/L和0.55 mg/L。该工艺中预臭氧可显著降低有机物分子质量水平,混凝沉淀砂滤主要去除分子质量3 k Da的有机物,后臭氧则将大分子有机物进一步氧化为分子质量3k Da的有机物,后者通过生物活性炭滤池得到有效地去除。因此,通过臭氧和生物活性炭的联用,能够有效去除有机物,是一种适宜的饮用水深度处理工艺。  相似文献   

10.
臭氧-生物沸石处理有机微污染水研究   总被引:2,自引:1,他引:1  
研究了臭氧氧化、生物过滤、沸石吸附对微污染水中有机物的不同处理效果和组合工艺的竞争、协同效果。结果表明:对于CODMn为6.30~7.20 mg/L的原水,在臭氧投加量为2.1 mg/L,接触时间为15 min时,CODMn的去除率可达10.8%;沸石吸附对CODMn的平均去除率为11.5%,生物沸石对CODMn的平均去除率为32.3%。臭氧-沸石工艺的CODMn平均去除率为15.6%,小于工艺组成单元的单独去除率的加和,各单元在有机物处理上存在竞争关系。臭氧-生物沸石工艺的CODMn平均去除率为45.5%,大于臭氧氧化和生物过滤独立单元去除率的加和,各单元之间为协同作用关系,因此宜采用臭氧-生物沸石工艺处理有机微污染水体。  相似文献   

11.
采用臭氧-生物活性炭(O3-BAC)组合工艺对某工业园区再生水厂MBR出水进行了深度净化的中试研究,主要考察了组合工艺各节点对常规指标的处理效果。结果表明,臭氧投加量约3 mg/L(H2O)、臭氧接触塔接触时间为30min、活性炭滤池空床接触时间(BECT)为15 min时,O3-BAC组合工艺能有效去除水中色度、浊度,平均色度和浊度分别从21度和7.8 NTU降至3度和2.0 NTU以下;组合工艺对UV254、高锰酸盐指数的平均去除率分别约为39%和35%;对NH4+-N有一定的去除,去除率为58%~77%;组合工艺对粪大肠菌群去除效果显著,平均去除率在95%以上。O3-BAC组合工艺是一种有效工业园区再生水深度净化技术。  相似文献   

12.
以红薯浸泡液为碳源的生物反硝化   总被引:3,自引:1,他引:2  
梅翔  占晶  沙昊  谢玥  朱瑾 《环境工程学报》2010,4(5):1032-1036
为选择低碳氮比污水生物脱氮中合适的碳源,以搅拌罐浸泡淀粉类物质释放碳源,在确定利用红薯浸泡液为碳源后,以浸没式生物滤池为反应器进行生物反硝化实验。实验结果表明:20 g红薯置于2 L自来水中,采用250 r/m in的搅拌速度,搅拌频率为每搅拌3 h停1 h,2 d后得到的浸泡液COD浓度平均为5 921 mg/L,最高可超过7 000 mg/L;将此红薯浸泡液和污水以1∶50的流量比例,采用分别投加的方式进入反应器,污水中总氮、硝酸盐氮、亚硝酸盐氮及氨氮的平均去除率分别为88.6%、91.6%、88.2%和54.8%,出水COD平均在30 mg/L以下;在红薯浸泡液COD浓度为5 700 mg/L左右时,进水中亚硝酸盐氮浓度与硝酸盐氮浓度比为3∶2时总氮去除率为95.3%,当该比例为2∶3时总氮去除率为88.2%。研究表明,红薯浸泡液是一种经济合适的碳源,采用红薯浸泡液作为低碳氮比污水生物处理中反硝化的碳源是可行的。  相似文献   

13.
化学生物絮凝工艺是利用将化学和生物协同絮凝作用处理污水的强化一级新工艺.试验通过在不同加药量情况下化学生物絮凝和化学絮凝工艺的中试试验对比研究,得出在相同加药量条件下,化学生物絮凝污染物去除效率均优于化学絮凝工艺10%~20%.在70 mg/L液体聚合氯化铝铁复配0.5 mg/L PAM的加药条件下,化学生物絮凝工艺经过30 min的水力停留时间,在进水CODCr为100~260 mg/L,TP为2~4 mg/L,SS为80~150 mg/L,NH3-N为10~25 mg/L条件下,出水CODCr、TP、SS、NH3-N满足城镇污水处理厂污染物排放二级标准.  相似文献   

14.
Li L  Zhu W  Zhang P  Zhang Z  Wu H  Han W 《Chemosphere》2006,62(9):1514-1522
AC (activated carbon)/O3-BAC (biological activated carbon) process was employed to treat secondary effluent and compared to O3-BAC process. The effects of ozone dosages and empty bed contact time (EBCT) in BAC on dissolved organic carbon (DOC) removal were investigated. The results showed that the presence of AC improved ozone utilization and biodegradability of the effluent. DOC removal increased with ozone dosage and EBCT in BAC, however, 3 mg l(-1) ozone dosage with 15 min oxidation time and 15 min EBCT in BAC were more economical and efficient. For DOC removal, AC/O3-BAC was more efficient than O3-BAC and its synergetic effect was more than that in O3-BAC process. The biomass of the subsequent BAC unit in AC/O3-BAC process was more than that in O3-BAC process and much more than that in BAC alone. Except for organic pollutants with molecular weight (MW) >10 kDa, those of other MW range were decomposed much more by AC/O3 process than by O3 process. GC/MS analysis showed that dibutyl phthalate, bis(2-ethylhexyl) phthalate, 4-bromo-3-chloroaniline, 2-propanone-ethylhydrazone and phenol derivatives were prevalent organic compounds in the secondary effluent. Some aromatic compounds, such as 4-bromo-3-chloroaniline and 2,4-dichloro-benzenamine disappeared after AC/O3 treatment. However, some small molecules were generated, after further biological treatment by BAC, the kinds and concentration of organic compounds were greatly reduced.  相似文献   

15.
以季铵化合物中最具潜在影响力、毒性较大的苄基季铵盐(BAC)为模型物,进行了BAC对好氧活性污泥吸附Ni2+的影响研究.结果表明,当反应液初始pH≤3时,不同浓度的BAC对好氧活性污泥吸附Ni2+的影响较小,当初始pH在3~9时,不同浓度的BAC对Ni2+吸附的抑制影响顺序为100 mg/L>20 mg/L>0 mg/...  相似文献   

16.
针对某炼油厂轻污染废水水质情况,选用了BAF(生物曝气滤池)工艺+SF(砂滤)工艺对该废水进行净化处理。通过试验研究,得到了BAF工艺合适的运行参数,取得了满意的试验结果。经BAF工艺处理后,出水COD和油平均浓度分别为9.78mg/L和0.24mg/L,再经SF工艺进一步去除SS后,出水SS平均浓度为3.8mg/L,系统处理出水完全达到工业回用水水质要求。试验证明:BAF工艺是一种高效的处理方法,适合炼油厂轻污染水的净化处理。  相似文献   

17.
根据昆明市第一污水处理厂深度处理微絮凝-D型滤池工艺的运行数据,评价了工艺出水水质及总磷(TP)去除效果,同时分析了混凝剂投加量及药剂费用。结果表明,微絮凝-D型滤池工艺出水TP平均浓度为0.15 mg/L,最优水平值为0.05 mg/L,95%保证值为0.37 mg/L,TP平均去除率为63.6%。出水悬浮固体(SS)浓度95%保证值为10 mg/L。混凝剂聚合氯化铝(PAC)的投加量在1.5~4 mg Al2O3/L范围波动,去除单位TP的PAC投加量平均值为16.7 mg Al2O3/mg-P,投加比为2~8 mol-Al/mol-P。当投加比超过5时,出水TP浓度可达到0.3 mg/L以下。吨水PAC成本平均值为0.017元/t。  相似文献   

18.
采用Fenton氧化-序批式膜生物反应器(SBMBR)组合工艺处理干法腈纶废水。结果表明,在废水初始pH值为3.0,H2O2投加量为90.0 mmol/L,Fe2+投加量为20.0 mmol/L,反应时间为2.0 h的条件下,Fenton氧化预处理对腈纶生产废水的COD去除率达到47.0%以上,COD由1 091 mg/L降至560 mg/L,废水的BOD5/COD由0.32升至0.69,废水的可生化性得到显著提高。Fenton处理出水与丙烯腈废水等比例混合后,采用SBMBR进行生化处理,在水力停留时间为24 h,90 min缺氧/150 min好氧交替运行的条件下,COD、NH4+-N和TN的平均去除率分别为71.7%、97.2%和47.4%,碳源不足是限制TN去除效果的主要影响因素。在无外加碳源的条件下,组合工艺处理后出水COD和NH4+-N浓度分别为117 mg/L和1.7 mg/L,出水水质可以稳定达到国家一级排放标准(GB8978-1996)。  相似文献   

19.
Improved solubilization of activated sludge by ozonation in pressure cycles   总被引:1,自引:0,他引:1  
Cheng CJ  Hong PK  Lin CF 《Chemosphere》2012,87(6):637-643
The generation of a large volume of activated sludge (AS) from wastewater treatment has increasingly become a great burden on the environment. Anaerobic digestion is routinely practiced for excess waste sludge; however, the process retention time is long because of kinetic limitation in the hydrolysis step. We tested the feasibility of applying ozone in pressure cycles to enhance the disintegration and solubilization of AS with the goal to prepare them for digestion using reduced ozone dose and contact time. The AS was subjected to repetitive pressure cycles in a closed vessel in which an ozone gas mixture was compressed into the slurry to reach 1040 kPa in the headspace to be followed by rapid venting. For a returned AS with total COD (tCOD) of 8200 mg L(-1), a dose of 0.01 gO(3)g(-1) total suspended solids (TSS) delivered via 20 pressure cycles within 16 min resulted in a 37-fold increase of the sCOD/tCOD ratio (due to increased soluble COD, i.e. sCOD) and a 25% reduction of TSS, in comparison to a dose of 0.08 gO(3)g(-1) TSS via bubbling contact over 15 min that resulted in a 15-fold increase of the sCOD/tCOD ratio and a 12% reduction of TSS. Sludge solubilization was evidenced by increased dissolved contents of total phosphorous (from 10 to 64 mg L(-1)), total nitrogen (from 14 to 120 mg L(-1)), and protein (from <15 to 39 mg L(-1)) in the sludge suspension after treatment, indicating significant solubilization of AS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏