首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

A computational fluid dynamics technique was used to evaluate the effect of traffic pollution on indoor air quality of a naturally ventilated building for various ventilation control strategies. The transport of street-level nonreactive pollutants emitted from motor vehicles through the indoor environment was simulated using the large eddy simulation (LES) of the turbulent flows and the pollutant transport equations. The numerical model developed herein was verified by available wind-tunnel measurements. Good agreement with the measured velocity and concentration data was found. Twelve sets of numerical scenario simulations for various roof- and side-vent openness and outdoor wind speeds were carried out. The effects of the air change rate, the indoor airflow pattern, and the external pollutant dispersion on indoor air quality were investigated. The control strategies of ventilation rates and paths for reducing incoming vehicle pollutants and maintaining a desirable air change rate are proposed to reduce the impact of outdoor traffic pollution during traffic rush hours. It was concluded that the windward side vent is a significant factor contributing to air change rate and indoor air quality. Air intakes on the leeward side of the building can effectively reduce the peak and average indoor concentration of traffic pollutants, but the corresponding air change rate is relatively low. Using the leeward cross-flow ventilation with the windward roof vent can effectively lower incoming vehicle pollutants and maintain a desirable air change rate during traffic rush hours.  相似文献   

2.
Paired indoor and outdoor concentrations of fine and coarse particulate matter (PM), PM2.5 reflectance [black carbon(BC)], and nitrogen dioxide (NO2) were determined for sixteen weeks in 2008 at four elementary schools (two in high and two in low traffic density zones) in a U.S.-Mexico border community to aid a binational health effects study. Strong spatial heterogeneity was observed for all outdoor pollutant concentrations. Concentrations of all pollutants, except coarse PM, were higher in high traffic zones than in the respective low traffic zones. Black carbon and NO2 appear to be better traffic indicators than fine PM. Indoor air pollution was found to be well associated with outdoor air pollution, although differences existed due to uncontrollable factors involving student activities and building/ventilation configurations. Results of this study indicate substantial spatial variability of pollutants in the region, suggesting that children’s exposures to these pollutants vary based on the location of their school.  相似文献   

3.
Effects of excess ground and building temperatures on airflow and dispersion of pollutants in an urban street canyon with an aspect ratio of 0.8 and a length-to-width ratio of 3 were investigated numerically. Three-dimensional governing equations of mass, momentum, energy, and species were modeled using the RNG k-epsilon turbulence model and Boussinesq approximation, which were solved using the finite volume method. Vehicle emissions were estimated from the measured traffic flow rates and modeled as banded line sources, with a street length and bandwidths equal to typical vehicle widths. Both measurements and simulations reveal that pollutant concentrations typically follow the traffic flow rate; they decline as the height increases and are higher on the leeward side than on the windward side. Three-dimensional simulations reveal that the vortex line, joining the centers of cross-sectional vortexes of the street canyon, meanders between street buildings and shifts toward the windward side when heating strength is increased. Thermal boundary layers are very thin. Entrainment of outside air increases, and pollutant concentration decreases with increasing heating condition. Also, traffic-produced turbulence enhances the turbulent kinetic energy and the mixing of temperature and admixtures in the canyon. Factors affecting the inaccuracy of the simulations are addressed.  相似文献   

4.
Numerical simulations were conducted to investigate the effects of building height ratio (i.e., HR, the height ratio of the upstream building to the downstream building) on the air quality in buildings beside street canyons, and both regular and staggered canyons were considered for the simulations. The results show that the building height ratio affects not only the ventilation fluxes of the rooms in the downstream building but also the pollutant concentrations around the building. The parameter, outdoor effective source intensity of a room, is then proposed to calculate the amount of vehicular pollutants that enters into building rooms. Smaller value of this parameter indicates less pollutant enters the room. The numerical results reveal that HRs from 2/7 to 7/2 are the favorable height ratios for the regular canyons, as they obtain smaller values than the other cases. While HR values of 5/7, 7/7, and 7/5 are appropriate for staggered canyons. In addition, in terms of improving indoor air quality by natural ventilation, the staggered canyons with favorable HR are better than those of the regular canyons.  相似文献   

5.
A study on indoor–outdoor RSPM (PM10, PM2.5 and PM1.0) mass concentration monitoring has been carried out at a classroom of a naturally ventilated school building located near an urban roadway in Delhi City. The monitoring has been planned for a year starting from August 2006 till August 2007, including weekdays (Monday, Wednesday and Friday) and weekends (Saturday and Sunday) from 8:0 a.m. to 2:0 p.m., in order to take into account hourly, daily, weekly, monthly and seasonal variations in pollutant concentrations. Meteorological parameters, including temperature, rH, pressure, wind speed and direction, and traffic parameters, including its type and volume has been monitored simultaneously to relate the concentrations of indoor–outdoor RSPM with them. Ventilation rate has also been estimated to find out its relation with indoor particulate concentrations. The results of the study indicates that RSPM concentrations in classroom exceeds the permissible limits during all monitoring hours of weekdays and weekends in all seasons that may cause potential health hazards to occupants, when exposed. I/O for all sizes of particulates are greater than 1, which implies that building envelop does not provide protection from outdoor pollutants. Further, a significant influence of meteorological parameters, ventilation rate and of traffic has been observed on I/O. Higher I/O for PM10 is indicating the presence of its indoor sources in classroom and their indoor concentrations are strongly influenced by activities of occupants during weekdays.  相似文献   

6.
The indoor/outdoor air pollution exposure continuity relationships are considered in an attempt to define the major parameters determining the relation. The widely accepted hypothesis of a homeostatic balance between indoor and outdoor pollutant levels has been disclaimed using particulate lead as an index contaminant. A serial filtration collection technique was employed and analysis was performed by atomic absorption spectrophotometry. The results of this study demonstrate the importance of considering parameters other than outdoor pollutant levels in determining indoor air quality.  相似文献   

7.
Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling.  相似文献   

8.
Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C3–C6), aromatic (C6–C9), halogenated (C1–C7), and oxygenated (C2–C9) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF2CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO2) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites.

Implications: Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for comprehensive VOCs and CO2 were completed for an extended period of over a year. Different hot spots were identified where leaked refrigerant and inadequate handling of laboratory solvents contributed to the high VOCs in the respective locations. CO2 levels reflected HVAC performance and poor ventilation. A list of recommendations has been proposed to eradicate these high levels of air pollution.  相似文献   


9.
In-vehicle carbon monoxide (CO) concentration profiles were monitored in a passenger vehicle driven along a heavily traveled route of a commercial/residential area of Beirut, Lebanon, under several ventilation modes. Trips were conducted during morning rush hours in spring and summer time. Concomitant monitoring of car-exterior CO level, ambient CO level and wind speed was also undertaken. The highest mean CO exposure was experienced for the “windows closed, vents closed” and “windows closed, AC on recirculation” ventilation settings, with mean CO levels of 37.4 and 30.8 ppm, respectively, exceeding the 1-h air quality guidelines. The exposure was less significant for other ventilation modes with respective mean values of 10.819ppm. Mean car-exterior CO levels were lower than the 1-h air quality guidelines, but exceeded the 8-h CO exposure guidelines. Ambient CO levels were low and non-representative of the personal exposure of individuals neither inside nor in the vicinity of road vehicles. In-vehicle CO levels revealed moderate to good correlations to out-vehicle CO levels for ventilation modes allowing for outdoor air intake, and no correlation to ambient CO levels and wind speed. Infiltration as a result of indoor–outdoor air exchange and intrusion from engine combustion/exhaust infiltration constituted the main sources of observed in-vehicle CO levels.  相似文献   

10.
Airflow and pollutant dispersion in a cross-harbor traffic tunnel were experimentally and numerically studied. Concentrations of the gaseous pollutants CO, NOx, and total hydrocarbons (THC) at three axial locations in the tunnel, together with traffic flow rate, traffic speed, and types of vehicle were measured. Three-dimensional (3D) turbulent flow and dispersion of air pollutants in the tunnel were modeled and solved numerically using the finite volume method. Traffic emissions were modeled accordingly as banded line sources along the tunnel floor. The results reveal that cross-sectional concentrations are nonuniformly distributed and that concentrations rise with downstream distance. The piston effect of vehicles alone can provide 9-23% dilution of air pollutants in the tunnel, compounded to a 23-74% dilution effect according to the ventilation condition.  相似文献   

11.
Abstract

Airflow and pollutant dispersion in a cross-harbor traffic tunnel were experimentally and numerically studied. Concentrations of the gaseous pollutants CO, NOx, and total hydrocarbons (THC) at three axial locations in the tunnel, together with traffic flow rate, traffic speed, and types of vehicle were measured. Three-dimensional (3D) turbulent flow and dispersion of air pollutants in the tunnel were modeled and solved numerically using the finite volume method. Traffic emissions were modeled accordingly as banded line sources along the tunnel floor. The results reveal that cross-sectional concentrations are nonuniformly distributed and that concentrations rise with downstream distance. The piston effect of vehicles alone can provide 9–23% dilution of air pollutants in the tunnel, compounded to a 23–74% dilution effect according to the ventilation condition.  相似文献   

12.
In the 1970s, a large ambulatory of the National Tile Museum, Lisbon, was closed with glass panes on both ground and first floor. Although this design was meant to protect the museum collection from ambient air pollutants, small openings between the glass panes remain, creating a semi-enclosed corridor. The effects of the glass panes on the indoor air quality were evaluated in a comparative study by monitoring the airborne particle concentration and the extent of particle deposition at the enclosed corridor as well as inside the museum building. Comparison of the indoor/outdoor ratio of airborne particle concentration demonstrated a high natural ventilation rate in the enclosed corridor as well as inside the museum building. PM10 deposition velocities on vertical surfaces were estimated in the order of 3?×?10?4 m s?1 for both indoor locations. Also, the deposition rates of dark-coloured and black particles in specific were very similar at both indoor locations, causing visual degradation. The effectiveness of the glass panes in protecting the museum collection is discussed.  相似文献   

13.
The effects of building configurations on pollutant dispersion around street canopies were studied numerically. The dispersion of pollutants emitted from ground sources was simulated by continuously discharging large number of particles into the computation domain. The mean wind velocities at each time-step were firstly computed by solving the time-dependent incompressible Navier–Stokes equations, while the fluctuated velocities were determined using a statistical procedure. The trajectories of the discharged particles were obtained from a Lagrangian particle model. Three categories of numerical simulation were conducted to study the effect of different canopy geometries on the pollutant dispersion. The computed wind field data were consistent with the wind field characteristics described in the previous wind tunnel studies. A counter-clockwise vortex was found resulting in high pollutant concentration at the windward side of the downstream building of the street canopy and low pollutant concentration at the leeward side of the upstream building. The increase in height of the urban roughness buildings would facilitate the pollutant dispersion in urban street canopy under certain building configurations. Two or more vortices stacked vertically in a street canopy were found when height of the upstream and downstream buildings of a street canopy was increased, preventing pollutants from escaping out of the canopy.  相似文献   

14.
Simultaneous measurements were made of the concentrations of NO, NO2, and CO inside and outside of a building. The building is located in the Los Angeles area, which is heavily polluted by photochemical smog, and the experiments were conducted at a time of the year when the pollutants in question tend to be high. The results shows that there is a direct relationship between the inside and outside concentrations, and that the phase lag between the concentrations depends principally on the ratio of the building volume to the ventilation rate. Although the outside concentrations of the pollutants in question did not follow the same pattern every day, peak concentrations seemed to be related to “rush-hour” traffic. By reducing ventilation rates during these periods, it may be possible to reduce the concentration peaks inside of the building. The building involved in the current study was not located in the immediate vicinity of heavy traffic, and the indoor concentrations of NO, NO2, and CO did not appear to be very severe when compared to those defined by present air quality standards. Finally, the results support the belief that NO and O3 do not co-exist indoors except in very small quantities.  相似文献   

15.
This paper investigates the impacts of building facades and ground heating on the wind flow and pollutant transport in street canyons using the computational fluid dynamic (CFD) technique. Street canyons of H/W (H representing the building height and W the street width) varied from 0.1 to 2, which covered the basic flow regimes of skimming flow (H/W=1 or 2), wake interference flow (H/W=0.5), and isolated roughness flow (H/W=0.1), were examined in a series of sensitivity tests. Heating that occurred on different surfaces, including ground surface and building façades, posed considerable effects on the street canyon wind flow and pollutant transport compared with those under isothermal conditions. The CFD results showed that the mechanically induced wind flow and pollutant transport were complicated by the buoyancy under temperature stratification. Individual street canyons of different H/W and surface-heating scenarios exhibited their unique wind flow structure and pollutant transport behaviors. Two counter-rotating vortices were calculated in the street canyons of H/W=1, in which the zone of higher pollutant concentration under isothermal conditions was switched from the leeward side to the windward side. In the street canyon of H/W=2, the recirculating wind pattern was perturbed by surface heating that led to the development of either one primary vortex or three closely coupled vortices. Because of the complicated wind structure, the zones of higher pollutant concentration located either on the leeward or windward ground level were subjected to the surface-heating scenarios. Only two vortices were developed inside the street canyon of H/W=0.5. The large primary vortex, centered inside the street canyon, extended above the roof level of the street canyon. Meanwhile, a small secondary vortex was found at the ground-level windward corner whose size results as a function of surface-heating configurations. Finally, in the street canyon of H/W=0.1, an isolated clockwise-rotating vortex was developed beside the leeward building while the wind in the windward side blew in the prevailing wind direction. As a result, air pollutant emitted at the street centerline was unlikely to be carried into the leeward vortex. Instead, it was dispersed rapidly on the windward side before being removed from the street canyon.  相似文献   

16.
As part of a larger program to investigate indoor sources of air pollution, an indoor/outdoor sampling program was carried out for NO, NO2, and CO In four private houses which had gas stoves. The four houses chosen for study represented different surrounding land use, life styles, and house age and layout. The pollutant gases were measured essentially simultaneously at three indoor locations and one outdoor location. The results of the program showed that indoor levels of NO and NO2 are directly related to stove use in the homes tested. Furthermore, these stoves often produced more NO2 than NO. In some instances, the levels of NO2 and CO in the kitchen exceeded the air quality standards for these pollutants if such outdoor standards were to be applied to indoors and the data for the sampling periods were typical of an entire year. A diffusion experiment conducted in one of the houses showed that the half-life for NO2 was less than one-third that for either NO or CO. Oxidation of NO to NO2 (based upon comparing the half-life of NO to CO) does not appear to occur to a significant degree indoors.  相似文献   

17.
The present study examines the behaviour of the ADMS-Urban air quality forecasting model in predicting dispersion of traffic-related pollutants in urban areas. The study has been carried out in Ravenna (NE Italy), a medium-sized town where pollution produced by vehicle traffic accounts for most of the emissions. ADMS-Urban performances have been assessed through statistical analysis, by comparing carbon monoxide concentrations (vehicle traffic tracing pollutant) estimated by the model with concentrations measured by stations of the air quality monitoring network. Although the correspondence of values estimated by ADMS-Urban with measured values turns out to be satisfactory, the study shows that the model tends to produce an underestimated value compared with the actual situation, and identifies a corrective method that makes it possible to improve the relevant performances. Furthermore, the diagnostic analysis highlights that the model performances depend upon some meteorological parameters.  相似文献   

18.
Many energy conservation strategies for residences involve reducing house air exchange rates. Reducing the air exchange rate of a house can cause an increase in pollutant levels if there is an indoor pollution source and if the indoor pollutant source strength remains constant. However, if the indoor pollutant source strength can also be reduced, then it is possible to maintain or even improve indoor air quality. Increasing the insulation level of a house is a means of achieving energy conservation goals and, in addition, can reduce the need for space heating and thereby reduce the pollutant source strengths of combustion space heaters such as unvented kerosene space heaters, unvented gas space heaters, and wood stoves. In this paper, the indoor air quality trade-off between reduced infiltration and increased insulation in residences is investigated for combustion space heaters. Two similar residences were used for the experiment. One residence was used as a control and the other residence had infiltration and insulation levels modified. An unvented propane space heater was used as the source in this study. A model was developed to describe the dependence of both indoor air pollution levels and the appliance source strengths on house air exchange rates and house insulation levels. Model parameters were estimated by applying regression techniques to the data. Results show that indoor air pollution levels in houses with indoor combustion space heating pollution sources can be held constant (or lowered) by reducing the thermal conductance by an amount proportional to (or greater than) the reduction of the air exchange rate.  相似文献   

19.
Modeling relationships between indoor and outdoor air quality   总被引:4,自引:0,他引:4  
Information about the ratio between indoor and outdoor concentrations (IO ratios) of air pollutants is a crucial component in human exposure assessment. The present study examines the relationship between indoor and outdoor concentrations as influenced by the combined effect of time patterns in outdoor concentrations, ventilation rate, and indoor emissions. Two different mathematical approaches are used to evaluate IO ratios. The first approach involves a dynamic mass balance model that calculates distributions of transient IO ratios. The second approach assumes a linear relationship between indoor and outdoor concentrations. We use ozone and benzene as examples in various modeling exercises. The modeled IO ratio distributions are compared with the results obtained from linear fits through plots of indoor versus outdoor concentrations.  相似文献   

20.
Urbanization typically involves a continuous increase in motor vehicle use, resulting in congestion known as traffic jams. Idling emissions due to traffic jams combine with the complex terrain created by buildings to concentrate atmospheric pollutants in localized areas. This research simulates emissions concentrations and distributions for a congested street in Minsk, Belarus. Ground-level (up to 50-meters above the street's surface) pollutant concentrations were calculated using STAR (version 3.10) with emission factors obtained from the U.S. Environmental Protection Agency, wind speed and direction, and building location and size. Relative emissions concentrations and distributions were simulated at 1-meter and 10-meters above street level. The findings demonstrate the importance of wind speed and direction, and building size and location on emissions concentrations and distributions, with the leeward sides of buildings retaining up to 99 percent of the emitted pollutants within 1-meter of street level, and up to 77 percent 10-meters above the street.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号