首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
为了对长三角地区大气污染进行防治和控制,了解长三角地区大气环境质量变化规律,有必要对其颗粒物的组成及特征进行分析,以揭示其形成机制。采用Partisal plus2025 型连续空气采样机在嘉兴双桥农场(长三角中心)进行采样,利用对采样样品化学分析的结果,分析了PM10、PM25的化学组成、质量浓度的分布特征及其相对关系。 PM25和PM10中19种无机元素质量浓度的总和约占其质量浓度的23%和25%,其中Al、Si、Ca是主要贡献元素;8种水溶性离子质量浓度总和约占PM25和PM10质量浓度的51%和43%,其中NO-3和SO2-4是主要贡献成分;有机碳的质量浓度约占PM25和PM10质量浓度的1612%和1743%,元素碳的质量浓度约占PM25和PM10质量浓度的1697%和1584%,可见该地区存在较严重的二次有机碳污染和元素碳污染。研究结果为揭示大气颗粒物的形成机制和对其污染进行防治和控制提供了基础性的研究数据。  相似文献   

2.
We have investigated the filtering effects of three types of air control systems of enclosed structures on viable particles in the ambient air. Aspergillus fumigatus and other thermophilic organisms were used as monitors for viable particles. The indoor concentrations of viable particles were found to be affected by building design and the use of conventional mechanical air systems. Viable particles of approximately 4.0 μm and greater in aerodynamic diameter were filtered from the air while respirable size particles less than 4.0 μm were not filtered as well. There was evidence of growth of viable particles within the mechanical air systems. Conventional air control systems may not be adequate for the control of viable particle contamination of the indoor environment without modifications and proper maintenance.  相似文献   

3.
Several tiny organisms of various size ranges present in air are called airborne particles or bioaerosol which mainly includes live or dead fungi and bacteria, their secondary metabolites, viruses, pollens, etc. which have been related to health issues of human beings and other life stocks. Bio-terror attacks in 2001 as well as pandemic outbreak of flue due to influenza A H1N1 virus in 2009 have alarmed us about the importance of bioaerosol research. Hence characterization i.e. identification and quantification of different airborne microorganisms in various indoor environments is necessary to identify the associated risks and to establish exposure threshold. Along with the bioaerosol sampling and their analytical techniques, various literatures revealing the concentration levels of bioaerosol have been mentioned in this review thereby contributing to the knowledge of identification and quantification of bioaerosols and their different constituents in various indoor environments (both occupational and non-occupational sections). Apart from recognition of bioaerosol, developments of their control mechanisms also play an important role. Hence several control methods have also been briefly reviewed. However, several individual levels of efforts such as periodic cleaning operations, maintenance activities and proper ventilation system also serve in their best way to improve indoor air quality.  相似文献   

4.
Air pollution is a major environmental problem in urban areas worldwide. Delhi, the capital city of India, is no exception to the universal pattern of deteriorating urban air quality with concentration of pollutants being well above the recommended WHO levels. The magnitude and urgency of the problem as a global environmental issue needs a systematic understanding of the potential causes of pollution and their contribution to air quality. In the present study, ambient air quality data (1987–2006) of SO2, NO2, SPM, and RSPM were analyzed to asses the changing air quality in the study area and to evaluate the effect of measures taken to control it. The primary data were collected from 1,583 households to examine the relationship between outdoor and indoor pollution level. Based on the data, the current study concludes that despite the implementation of different pollution-controlling measures, the pollutants, especially the particulate pollutants, were well above the standard limits set by CPCB. Integration between technological and social approach of urban planning is required to mitigate and manage urban environmental problems in sustainable manner.  相似文献   

5.
Dry and irritated mucous membranes of the eyes and airways are common symptoms reported in office-like environments. Earlier studies suggested that indoor pollutants were responsible. We have re-evaluated, by review of the literature, how low relative humidity (RH) may influence the immediately perceived indoor air quality (IAQ), including odour, and cause irritation symptoms (i.e. longer-term perceived IAQ). "Relative humidity" were searched in major databases, and combined with: air quality, cabin air, dry eyes, formaldehyde, inflammation, mucous membranes, offices, ozone, pungency, sensory irritation, particles, precorneal tear film, sick building syndrome, stuffy air, and VOCs. The impact of RH on the immediately and longer-term perceived IAQ by VOCs, ozone, and particles is complex, because both the thermodynamic condition and the emission characteristics of building materials are influenced. Epidemiological, clinical, and human exposure studies indicate that low RH plays a role in the increase of reporting eye irritation symptoms and alteration of the precorneal tear film. These effects may be exacerbated during visual display unit work. The recommendation that IAQ should be "dry and cool" may be useful for evaluation of the immediately perceived IAQ in material emission testing, but should be considered cautiously about the development of irritation symptoms in eyes and upper airways during a workday. Studies indicate that RH about 40% is better for the eyes and upper airways than levels below 30%. The optimal RH may differ for the eyes and the airways regarding desiccation of the mucous membranes.  相似文献   

6.
Systematic characterization of morphological, mineralogical, chemical and toxicological properties of various size fractions of the atmospheric particulate matter was a main focus of this study together with an assessment of the human health risks they pose. Even though near-ground atmospheric aerosols have been a subject of intensive research in recent years, data integrating chemical composition of particles and health risks are still scarce and the particle size aspect has not been properly addressed yet. Filling this gap, however, is necessary for reliable risk assessment. A high volume ambient air sampler equipped with a multi-stage cascade impactor was used for size specific particle collection, and all 6 fractions were a subject of detailed characterization of chemical (PAHs) and mineralogical composition of the particles, their mass size distribution and genotoxic potential of organic extracts. Finally, the risk level for inhalation exposure associated to the carcinogenic character of the studied PAHs has been assessed. The finest fraction (< 0.45 μm) exhibited the highest mass, highest active surface, highest amount of associated PAHs and also highest direct and indirect genotoxic potentials in our model air sample. Risk assessment of inhalation scenario indicates the significant cancer risk values in PM 1.5 size fraction. This presented new approach proved to be a useful tool for human health risk assessment in the areas with significant levels of air dust concentration.  相似文献   

7.
The EU directives on air quality force member states to inform the public on the status of the ambient air quality. The Internet is commonly used for this purpose and often air quality is being presented as an index ranging from good to bad. A review of existing websites and air quality indices shows that the way air quality is interpreted differs considerably. The paper presents a new air quality index. The index is part of a project to develop a website dedicated to comparing air quality in European cities. The common air quality index (CAQI) is not aimed at replacing existing local indices. The CAQI is a set of two indices: one for roadside monitoring sites and one for average city background conditions. Differentiating between roadside and general city conditions is a first step in assuring consistence in the parameters that are being compared.  相似文献   

8.
Along with the progress of urbanization and environmental deterioration, residents' desire for improved air quality is increasing. In order to quantify an individual's willingness-to-pay (WTP) for improved air quality in Jinan of eastern China, a contingent valuation method (CVM) was employed. A sample of 1,500 residents was chosen on the basis of multistage sampling methods with face-to-face interviews by using a series of hypothetical, open-ended scenario questions which were designed to elicit the respondents' WTP. Results showed that 59.7% of respondents were able to express their WTP and the mean WTP is 100 Chinese Yuan (CNY) per person per year. A probit model on the probability of a positive WTP and a regression model were developed to find the relationship between endogenous variables and WTP. Most parameters in the econometric analysis had the expected sign. Annual household income and expenditure on treating respiratory diseases significantly influence WTP. The rates of positive WTP and the monetary amount are larger for men than for women. Results also showed that people who lived in more polluted areas were willing to pay more for clean air. Unlike developed countries, clean air may only be considered as a public good in China in that more than 40% of respondents had no incentive to bear the costs of attempting to achieve better air quality, which indicates the relatively low environmental consciousness.  相似文献   

9.
Abstract

Along with the progress of urbanization and environmental deterioration, residents' desire for improved air quality is increasing. In order to quantify an individual's willingness-to-pay (WTP) for improved air quality in Jinan of eastern China, a contingent valuation method (CVM) was employed. A sample of 1,500 residents was chosen on the basis of multistage sampling methods with face-to-face interviews by using a series of hypothetical, open-ended scenario questions which were designed to elicit the respondents' WTP. Results showed that 59.7% of respondents were able to express their WTP and the mean WTP is 100 Chinese Yuan (CNY) per person per year. A probit model on the probability of a positive WTP and a regression model were developed to find the relationship between endogenous variables and WTP. Most parameters in the econometric analysis had the expected sign. Annual household income and expenditure on treating respiratory diseases significantly influence WTP. The rates of positive WTP and the monetary amount are larger for men than for women. Results also showed that people who lived in more polluted areas were willing to pay more for clean air. Unlike developed countries, clean air may only be considered as a public good in China in that more than 40% of respondents had no incentive to bear the costs of attempting to achieve better air quality, which indicates the relatively low environmental consciousness.  相似文献   

10.
Estimates of source contribution are important for setting more realistic air quality standards for total suspended particles (TSP). Soil dust contributes a major fraction of the atmospheric particulate load in India during the dry months. Chemical element balance (CEB) analysis shows that nearly 50% to 60% of the TSP in Bombay during winter months are of crustal origin. Wind-raised dust from parched earth surface and traffic dust from badly maintained roads are the probable causes of the observed higher contribution of soil dust.  相似文献   

11.
BackgroundAirborne particles are a complex mix of organic and inorganic compounds, with a range of physical and chemical properties. Estimation of how simultaneous exposure to air particles affects the risk of adverse health response represents a challenge for scientific research and air quality management. In this paper, we present a Bayesian approach that can tackle this problem within the framework of time series analysis.MethodsWe used Dirichlet process mixture models to cluster time points with similar multipollutant and response profiles, while adjusting for seasonal cycles, trends and temporal components. Inference was carried out via Markov Chain Monte Carlo methods. We illustrated our approach using daily data of a range of particle metrics and respiratory mortality for London (UK) 2002–2005. To better quantify the average health impact of these particles, we measured the same set of metrics in 2012, and we computed and compared the posterior predictive distributions of mortality under the exposure scenario in 2012 vs 2005.ResultsThe model resulted in a partition of the days into three clusters. We found a relative risk of 1.02 (95% credible intervals (CI): 1.00, 1.04) for respiratory mortality associated with days characterised by high posterior estimates of non-primary particles, especially nitrate and sulphate. We found a consistent reduction in the airborne particles in 2012 vs 2005 and the analysis of the posterior predictive distributions of respiratory mortality suggested an average annual decrease of − 3.5% (95% CI: − 0.12%, − 5.74%).ConclusionsWe proposed an effective approach that enabled the better understanding of hidden structures in multipollutant health effects within time series analysis. It allowed the identification of exposure metrics associated with respiratory mortality and provided a tool to assess the changes in health effects from various policies to control the ambient particle matter mixtures.  相似文献   

12.
This study examines the relationship between air pollution, social deprivation and health in the city of Leeds, UK under a baseline and three distance-based road user charging (RUC) scenarios set at 2 pence, 10 pence and 20 pence/km. Through application of a series of linked models of traffic, emission and pollutant dispersion, air quality was modelled in response to RUC scenarios. The pollutant modelled were NO(2), PM(10), CO, benzene and 1,3-butadiene, though results of NO(2) are used in this study. The RUC scenarios were compared with the 'base' scenario, all set for the year 2005. The RUC initiatives result in the differences in ambient concentrations of NO(2). The study correlates NO(2) concentrations with derived indices of social deprivation and health. The study concludes that positive but weak relationship exists between air quality and social deprivation, and indicates that deprived population groups are disproportionately exposed to higher NO(2) levels. The relationship between air quality and health status of the population is weak. There is a strong relationship between social deprivation and health status of the population. The study concludes that RUC scenarios result in reducing disparity between affluent and deprived populations.  相似文献   

13.
Air quality is managed in Great Britain via an effects-based, risk management process designed to provide a dynamic solution to public health issues associated with elevated concentrations of seven specified air pollutants. This paper is concerned with an examination and evaluation of the process of Local Air Quality Management (LAQM) in Great Britain from the late 1980s to date as a risk management process. The statutory basis of LAQM process is provided by the Environment Act 1995. The Act provides a framework in which national and local actions are required to identify and remediate areas of poor air quality. Within this framework, the implementation of the process at national and local levels is considered, leading to an identification and assessment of risks in the formulation and implementation of air quality management policy and practice. Local Authorities began the process of Review and Assessment in 1999 and the first round of the process concluded in 2001. Following this, some 129 Local Authorities declared one or more Air Quality Management Areas (AQMAs). The Review and Assessment elements of the framework were subjected to an evaluation in 2001 and the essential elements of it were confirmed as fit for purpose. The evaluation led to a confirmation of the process of LAQM but also a simplification based on the experience of Round 1. Now, a two step process is required comprising of an Updating and Screening Assessment and, where a risk of exceeding an Air Quality Objective (AQO) is identified, a Detailed Assessment follows. The Government has identified a time scale for Review and Assessment through to 2010 and also introduced the requirement of a regular Progress Report in order that a Local Authority is able to address routine matters of air quality management. The risks inherent in epidemiological or scientific uncertainty are factored into the LAQM process at an early stage of the process and, by identifying the risks and subjecting them to regular review, the process provides a 'level playing field' across spatial and temporal scales. Whilst the process of LAQM described in this paper has been developed for Great Britain, the generic elements of the process are applicable to other countries challenged by air pollution problems which require both national and local action to resolve them.  相似文献   

14.
Particulate air pollution in Lanzhou China   总被引:4,自引:0,他引:4  
Chu PC  Chen Y  Lu S  Li Z  Lu Y 《Environment international》2008,34(5):698-713
Concentrations of total suspended particles (TSP) and PM(10) in Lanzhou China have been kept high for the past two decades. Data collected during the intensive observational period from October 1999 to April 2001 show high TSP and PM(10) concentrations. Starting from November, the PM(10) pollution intensifies, and reaches mid to high alert level of air pollution, continues until April next year, and is at low alert level in the summer. In the winter and spring, the TSP concentration is 2-10 times higher than the third-level criterion of air quality (severe pollution). Effects of intrinsic factors (sources of pollution) and remote preconditions (propagation of dust storms) for severe PM(10) and TSP pollution in Lanzhou are analyzed.  相似文献   

15.
Residents of Xuan Wei County in China have unusually high lung cancer mortality that cannot be attributed to tobacco use or occupational exposure. They are exposed to smoke from unvented, open pit coal or wood fires (often used for cooking and heating). The variation in lung cancer rates among communes within the county suggests that indoor combustion of smoky coal may be the prime determinant of lung cancer. To characterize the air in Xuan Wei homes, samples of air particles and semivolatile organic compounds were collected from homes located in two communes; one commune has a high rate of lung cancer, and the other has a low rate. Samples collected in the commune where the lung cancer rate is high and where smoky coal is the predominant fuel contained high concentrations of small particles with high organic content; organic extracts of these samples were mutagenic. Samples from homes in the wood-burning commune, which has a low rate of lung cancer, consisted mostly of larger particles of lower organic content and mutagenicity. The smoky coal sample was a mouse skin carcinogen and was a more potent initiator of skin tumors in comparison to the wood or smokeless coal sample.  相似文献   

16.
This study was performed to investigate the concentration of PM(10) and PM(2.5) inside trains and platforms on subway lines 1, 2, 4 and 5 in Seoul, KOREA. PM(10), PM(2.5), carbon dioxide (CO(2)) and carbon monoxide (CO) were monitored using real-time monitoring instruments in the afternoons (between 13:00 and 16:00). The concentrations of PM(10) and PM(2.5) inside trains were significantly higher than those measured on platforms and in ambient air reported by the Korea Ministry of Environment (Korea MOE). This study found that PM(10) levels inside subway lines 1, 2 and 4 exceeded the Korea indoor air quality (Korea IAQ) standard of 150 microg/m(3). The average percentage that exceeded the PM(10) standard was 83.3% on line 1, 37.9% on line 2 and 63.1% on line 4, respectively. PM(2.5) concentration ranged from 77.7 microg/m(3) to 158.2 microg/m(3), which were found to be much higher than the ambient air PM(2.5) standard promulgated by United States Environmental Protection Agency (US-EPA) (24 h arithmetic mean: 65 microg/m(3)). The reason for interior PM(10) and PM(2.5) being higher than those on platforms is due to subway trains in Korea not having mechanical ventilation systems to supply fresh air inside the train. This assumption was supported by the CO(2) concentration results monitored in tube of subway that ranged from 1153 ppm to 3377 ppm. The percentage of PM(2.5) in PM(10) was 86.2% on platforms, 81.7% inside trains, 80.2% underground and 90.2% at ground track. These results indicated that fine particles (PM(2.5)) accounted for most of PM(10) and polluted subway air. GLM statistical analysis indicated that two factors related to monitoring locations (underground and ground or inside trains and on platforms) significantly influence PM(10) (p<0.001, R(2)=0.230) and PM(2.5) concentrations (p<0.001, R(2)=0.172). Correlation analysis indicated that PM(10), PM(2.5), CO(2) and CO were significantly correlated at p<0.01 although correlation coefficients were different. The highest coefficient was 0.884 for the relationship between PM(10) and PM(2.5).  相似文献   

17.
Improper natural ventilation practices may deteriorate indoor air quality when in close proximity to roadways, although the intention is often to reduce energy consumption. In this study, we employed a CFD-based air quality model to quantify the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building. Our study found that the building envelope restricts dispersion and dilution of particulate matter. The indoor concentration in the baseline condition located 10 m away from the roadway is roughly 16–21% greater than that at the edge of the roadway. The indoor flow recirculation creates a well-mixed zone with little variation in fine particle concentration (i.e., 253 nm). For ultrafine particles (< 100 nm), a noticeable decrease in particle concentrations indoors with increasing distance from the road is observed due to Brownian and turbulent diffusion. In addition, the indoor concentration strongly depends on the distance between the roadway and building, particle size, wind condition, and window size and location. A break-even point is observed at D ~ 2.1 (normalized distance from the roadway by the width of the road). The indoor particle concentration is greater than that at the highway where D < 2.1, and vice versa. For new building planning, the distance from the roadway and the ambient wind condition need to be considered at the early design stage whereas the size and location of the window openings, the interior layout, and the placement of fresh air intakes are important to the indoor air quality of existing buildings adjacent to roadways.  相似文献   

18.
This article reports the results of an examination of the relationships between degree of sprawl and improvements in ozone air quality for 52 metropolitan areas in the US. It also examines state political alignment and environmental resources with regard to these two primary objects of investigation. Evidence of a relationship between sprawl and air quality improvement was identified, but the evidence is ambiguous. More research appears warranted to explore the sprawl–air quality improvement relationship. Electronic Publication  相似文献   

19.
为探索新的空气质量预报方法,提高预报准确率,采用统计和对比方法,分析了长沙市空气质量现状,介绍了天气形势相似及动态逐步回归两种空气质量统计预报方法,并对其一年多的运行结果进行了检验和对比。结果表明,长沙市空气污染主要由PM\-\{10\}和SO\-2浓度超标引起, 且具有明显的空间分布特征;5年来长沙城市空气质量明显好转;两种预报方法对各污染物都有一定的预报能力,预报的误差绝对值多集中在30以内,而级别误差基本上在1级以内。两种方法对NO\-2的预报准确率均在98%左右,预报效果优良。绝对误差对比发现,两种预报方法对SO\-2的预报明显优于PM\-\{10\}预报;级别准确率对比时,两种预报方法对3种污染物的预报准确率相近。两种预报方法对3个污染因子的预报准确率呈现出NO\-2优于SO\-2优于PM\-\{10\}的趋势。  相似文献   

20.
A subcommittee of the Nordic Committee for Building Codes has released guidelines for building regulations regarding indoor air quality, especially concerning ventilation. The main features of the guidelines, such as acceptable outdoor air quality for ventilation and minimum outdoor air flows for dwellings and offices, are presented and discussed. Mechanical ventilation is, in principle, required in all buildings including dwellings, due to the requirement of a minimum outdoor air change of 0.5 h−1 and the normal highly airtight nature of new buildings. The guidelines are a basis for designing energy-efficient buildings while maintaining an indoor air quality which provides acceptable comfort and does not impair health.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号