首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
In this study, the applicability of physico-chemical methods was investigated for the pre-treatment of the olive mill effluents prior to the discharge into the common sewerage ending with a municipal wastewater treatment plant. The samples were taken from an olive oil industry operated as three-phase process located in Turkey. Various pre-treatment methods including acid craking, polyelectrolyte and lime additions were applied. Advanced oxidation study using Fenton's process was also investigated following pre-treatment by acid cracking and cationic polyelectrolyte. Acid cracking alone gave satisfactory treatment efficiencies and polyelectrolite additions to the acid-cracked samples enhanced treatment efficiency. Since a complete treatment plant is available at the end of the sewer system, results indicated that the effluents of the investigated industry could be discharged into the municipal sewerage in the case of total chemical oxygen demand (CODtot), suspended solid (SS) and volatile suspended solid (VSS) concentrations according to the Turkish Water Pollution Control Regulation after pre-treatment with 5 ppm anionic polyelectrolyte following acid cracking. The minimum CODtot, SS and VSS removals were observed when raw wastewater was pre-treated with lime and the discharge standards to the municipal sewer system could not be met. Advanced oxidation with Fenton's process was applied after acid cracking and cationic polyelectrolyte treatment in order to investigate further reduction in chemical oxygen demand (COD) concentration for minimizing the influence of this industrial discharge on the existing municipal wastewater treatment plant. Results indicated that CODtot removal increased up to 89% from 74% after Fenton's oxidation for the acid cracked samples in which cationic polyelectrolite (10 ppm) was added.  相似文献   

2.
Three wastewater samples from a pharmaceutical plant formulating medical ointments were subjected to lab-scale treatment by a Fenton-like system in combination with lime coagulation. All samples were plant pre-treated by adsorption/flocculation/filtration processes with utilization of bentonite, but the quality of effluents did not comply with the regulations for wastewater discharged to local sewerage. The optimization of Fenton-like oxidation demonstrated the highest process efficacy at H(2)O(2)/COD weight ratio of 2:1, H(2)O(2)/Fe(2+) molar ratio of 10:1 and 2h of treatment time. The fast pH decrease to acidic values approximately 3 during first min of oxidation for all effluents suggested that pH adjustment was unnecessary. Combination of Fe(III) precipitation and lime coagulation proved feasible to improve considerably COD and residual iron concentration reduction in pharmaceutical effluents. Additionally, considerable BOD(7) reduction and BOD(7)/COD ratio improvement of pharmaceutical wastewater samples was achieved by combined treatment. The application of Fenton-like oxidation with subsequent iron (III)/lime coagulation did not only enhance the quality of pharmaceutical effluents with different chemical characteristics and help to meet the requirements for wastewater discharged to sewage, but also improve the biodegradability of pharmaceutical effluents.  相似文献   

3.
Fenton's pre-treatment of mature landfill leachate   总被引:20,自引:0,他引:20  
Lopez A  Pagano M  Volpe A  Di Pinto AC 《Chemosphere》2004,54(7):1005-1010
The aim of this study was to check the effectiveness of the Fenton's reagent (Fe2+ + H2O2 + H+) for the pre-treatment of a municipal landfill leachate with the objective of improving its overall biodegradability, evaluated in terms of BOD5/COD ratio, up to a value compatible with biological treatment. The leachate came from a municipal sanitary landfill located in southern Italy and the average values of its main parameters were: pH=8.2; COD=10,540 mgl(-1); BOD5=2,300 mgl(-1); TOC=3,900 mgl(-1); NH4-N=5210 mgl(-1); conductivity=45,350 microScm(-1); alkalinity=21,470 mgl(-1) CaCO3. The effect of initial pH value on the pre-treatment effectiveness was evaluated by titrating the amount of acidic by-products formed. The extent of leachate oxidation was monitored and controlled by both pH and redox potential measurements. The best operational conditions for achieving the desired goal (i.e., BOD5/COD> or =0.5) resulted: Fe2+=275 mgl(-1); H2O2=3,300 mgl(-1); initial pH=3; reaction time=2 h. At the end of the Fenton's pre-treatment, in order to permit a subsequent biological treatment, residual ferric ions were removed increasing the pH up to 8.5 by adding 3 gl(-1) of Ca(OH)2 and 3 mgl(-1) of a cationic polyelectrolyte, the latter as an aid to coagulation. This final step also resulted in a further modest removal of residual COD due to co-precipitation phenomena.  相似文献   

4.
随着大量污水处理厂的建成投运,中国污水处理事业的重心必然会从以建设为主转向建设与运行并重,运行管理将发挥越来越重要的作用。文中以南京市某城镇污水处理厂为例,分析该污水处理厂运行过程COD、NH^3-N排放超标问题,并提出对策(健全配套污水收集管网,提升工艺参数DO、NO^3-、NO^2-的控制水平,规范运行台账管理等),以期为其他城镇污水处理厂的运行管理提供参考。  相似文献   

5.
城市污水厂水质相关性及分布状态的研究和应用   总被引:1,自引:0,他引:1  
采用统计学及质量控制的一些基本理论及方法对污水处理厂的运行数据进行分析,得出城市污水处理厂BOD5、COD、SS、TN、TP等主要出水指标呈正态分布的规律;城市污水BOD5、COD、TN、TP等指标间存在显著线性相关性的结论.研究结论可用于污水处理厂制定经济合理的出水监测方案以及对污水处理厂运行可靠性等进行评估.  相似文献   

6.
As pollution becomes one of the biggest environmental challenges of the twenty-first century, pollution of water threatens the very existence of humanity, making immediate action a priority. The most persistent and hazardous pollutants come from industrial and agricultural activities; therefore, effective treatment of this wastewater prior to discharge into the natural environment is the solution. Advanced oxidation processes (AOPs) have caused increased interest due to their ability to degrade hazardous substances in contrast to other methods, which mainly only transfer pollution from wastewater to sludge, a membrane filter, or an adsorbent. Among a great variety of different AOPs, a group of electrochemical advanced oxidation processes (EAOPs), including electro-Fenton, is emerging as an environmental-friendly and effective treatment process for the destruction of persistent hazardous contaminants. The only concern that slows down a large-scale implementation is energy consumption and related investment and operational costs. A combination of EAOPs with biological treatment is an interesting solution. In such a synergetic way, removal efficiency is maximized, while minimizing operational costs. The goal of this review is to present cutting-edge research for treatment of three common and problematic pollutants and effluents: dyes and textile wastewater, olive processing wastewater, and pharmaceuticals and hospital wastewater. Each of these types is regarded in terms of recent scientific research on individual electrochemical, individual biological and a combined synergetic treatment.  相似文献   

7.
The St. Lawrence River (SLR) is the second largest waterway in North America. The discharge of the City of Montreal wastewater treatment plant (WWTP) represents the largest volume of treated wastewaters being released into the river. It also ranks as the largest sewage treatment plant of its kind in North America. Over the last decade, intensive multidisciplinary research has focused on assessing the impacts of Montreal wastewater effluents on the SLR. We describe the major findings of these investigations, including the determination of the fate of contaminants, bioaccumulation in fish and invertebrates, ecotoxicological measurements of aquatic animal health, evaluation of endocrine disruption, parasitism in fish, and combined effects of multiple stressors on the SLR. Impacts of the effluents from the WWTP on aquatic organisms from the SLR are both toxicological and ecological, demonstrating the need for an integrated view of the impacts of municipal effluents on aquatic ecosystems.  相似文献   

8.
Constant magnetic field (CMF) was investigated for its potential to intensify chemical oxygen demand (COD) removal in wastewater when applied with a generalized Fenton reaction. Various types of industrial and domestic wastewater were tested in the experiment. A significant dependence was observed between the wastewater type, dose of reacting substances, time of exposure to CMF, effectiveness of COD removal, and the rate of the advanced oxidation process. The use of CMF resulted in the improvement of the treatment process; however, the efficiency depended to a great extent on the type of wastewater and characteristics of the contained organic matter. Domestic wastewater seemed to be most amenable to the applied treatment (82% COD reduction). The least reduction in COD occurred for wood industry wastewater. In the analyzed wastewater, intense oxidation was observed during the first 60 minutes of the process. Longer reaction time did not increase COD reduction, with the exception of wood industry wastewater. The experiment revealed the possibility of applying smaller doses of the Fenton's reagent, thereby keeping up unchanged treatment efficiency, provided that CMFs are applied.  相似文献   

9.
采用UASB中试(100 m3/d)对生活污水处理进行了研究。试验结果表明,采用此系统处理生活污水,出水水质良好。COD的去除率在52%~83%,出水的COD值<100 mg/L以下,SS的去除率在95%左右,UASB处理生活污水的最佳停留时间为6 h。产气率在0.1 m3/d。不管停留时间在10 h、5 h,出水的氨氮、乙酸值比进水的高;钙、镁、总氮、总磷、硫酸根和硝酸根离子出水值比进水值低。  相似文献   

10.
采用“预处理(酸化沉降+铁炭微电解+石灰中和)-生化(水解酸化+两级好氧生化)-深度处理(Fenton试剂催化氧化+石灰中和)”组合工艺对提铜选矿药剂生产废水进行现场中试实验研究,主要考察其COD去除、脱色、除味效果,重点考察生化单元运行特性及其对有机物的去除能力.实验结果表明,该组合工艺对该生产废水具有较好的净化效果,出水清澈透明、无气味,主要出水水质指标pH、色度、COD可以达到《污水综合排放标准(GB8976-1996)》二级标准.  相似文献   

11.
放电等离子体与饲养酵母联合处理味精废水的初步研究   总被引:7,自引:0,他引:7  
对采用放电等离子体与饲养酵母联合处理味精废水进行了初步研究。结果表明,放电等离子体预处理后废水的CODcr值普遍升高,但经假丝酵母联合处理后CODCr去除率增加了38.3%,效果明显优于仅采用饲养酵母法处理的味精废水,说明放电等离子体预处理可使味精废水中的有机大分子破坏成小分子,有利于生物降解,为味精废水治理提供了一条新的途径。实验初步研究了联合处理后的CODcr去除率与预处理电压、预处理电流、预处理次数的关系,结果表明存在相应的最优值。  相似文献   

12.
高浓度钻井废水的混凝-催化氧化处理   总被引:2,自引:0,他引:2  
以华北油田某深井的高浓度钻井废水(COD高达14 460.0 mg/L)为研究对象,提出了酸化-混凝-催化氧化-吸附的组合处理工艺。重点研制了钻井废水催化氧化处理催化剂(镍基催化剂),通过实验确定了最佳工艺参数条件。着重考察了催化氧化处理的工艺条件,在pH值为4,次氯酸钙投加量为4.4 g/L,催化剂投加量为1.6 g/L的条件下COD降至403.5 mg/L,进一步吸附处理后COD降至139.9 mg/L、色度为30倍、石油类含量为3.8 mg/L、pH为8.0和SS浓度为52mg/L,最终出水水质达到《污水综合排放标准》(GB 8978-1996)二级标准,处理成本为84.8元/m3。  相似文献   

13.
This work examines the performance of a hydrous ferric oxide (HFO) reactive filtration (RF) process with coupled chemically enhanced secondary treatment (RECYCLE) for phosphorus removal from municipal wastewater (HFO-RF-RECYCLE). A 3-month, 0.95-ML/d (0.25-mgd) demonstration of HFO-RF-RECYCLE was performed at a municipal wastewater treatment plant equipped with oxidation ditches and secondary clarifiers. Influent to the plant averaged 6.0 mg/L phosphorus, with a tertiary effluent average of 0.011 mg/L phosphorus. Iron doses to the plant were low, at 5 mg/L. Inline recycling of HFO solution rejects to the plant influent resulted in a maximum 90.3%, dose-dependent reduction of phosphorus in the secondary effluent at 4.5 ML/d (1.2 mgd). Other results included reduction of total suspended solids and turbidity. A mass balance analysis was performed. We conclude that HFO-RF-RECYCLE may allow very low levels of phosphorus discharge from municipal wastewater treatment plants with a ferric-iron-based tertiary filtration process and residual recycling.  相似文献   

14.
In this study, a detailed wastewater profile and treatability studies of Demirtas Organized Industrial District (OID) were undertaken on a pilot-scale. The industrial categorisation of Demirtas OID was determined, and the wastewater characterisations of each industrial sector were analysed and the flow-rates were measured. The results were used to design a wastewater treatment plant for Demirtas OID. Pilot-scale chemical and biological treatability studies were carried out. The steady-state performance of the pilot-scale treatment system in removing chemical oxygen demand (COD) and suspended solids (SS) was studied for a period of three months. The removal efficiencies obtained in this study were 42% of COD and 67% of SS in the chemical treatment, and 84% of COD and 25% of SS in the biological treatment. The overall removal efficiency of the pilot-scale system was 91% COD and 75% SS. The pilot-scale study showed that the wastewater from Demirtas OID could be treated with biological and chemical methods, and the treated wastewater met the Regulation of Discharge Standards of Turkey. The significance of this study is that it is the first such system in Turkey to be tested on a pilot scale.  相似文献   

15.
偶氮二异庚腈的生产过程中产生大量的废水,其有机物和氨氮含量高,生化性差.为解决其处理达标问题,采用氨氮吹脱-上流式厌氧污泥床(UASB)-A/O- NaOCl强氧化-接触氧化的组合工艺对其进行了试验研究.结果表明,该工艺对COD、氨氮的去除率分别达到99%、98%以上.并在此试验研究的基础上,投资建设了一个污水处理站,采用氨氮吹脱-UASB-A/O-二级好氧-NaOCl强氧化-接触氧化-气浮池的组合工艺,经过一年多的运行,出水水质稳定,对COD、氨氮的去除率分别为99%、98%以上,出水水质达到《污水综合排放标准》(GB 8978-1996)的一级标准.  相似文献   

16.
微电解法预处理大蒜废水试验研究   总被引:2,自引:0,他引:2  
王娟  范迪 《环境工程学报》2008,2(7):951-954
分析了大蒜废水的特点,探讨了微电解法预处理大蒜废水的可行性,并采用微电解一接触氧化工艺分别对大蒜废水和大蒜蔬菜混合废水进行了试验研究.结果表明,微电解法预处理大蒜废水是可行的,提高了废水的可生化性,微电解较佳停留时间为20 min,微电解-接触氧化工艺处理出水水质为COD≤100 mg/L.  相似文献   

17.
Wastewater from the Afyon Alkaloids Factory (Afyon, Turkey) was subjected to low-pressure catalytic wet-air oxidation (CWAO) using Fenton's reagent, and the optimal reaction conditions were investigated. The CWAO using Fenton's reagent was applied to the factory effluent, diluted factory effluent, and aerobically pretreated wastewater. To find the optimum quantities of reagents, ferrous iron (Fe(+2))-to-substrate ratios of 1:10, 1:25, and 1:50 and hydrogen peroxide (H2O2)-to-Fe(+2) ratios of 1, 5, and 10 were investigated, and the treatment was carried out at different temperatures. High chemical oxygen demand (COD) removals were obtained at 50 degrees C, with the Fe(+2)-to-substrate ratio range between 1:10 and 1:25. The change in H2O2-to-Fe(+2) ratios did not cause any considerable effect. Also, the percentages of COD removals were nearly the same, so the ratio H2O2:Fe(+2):1 is recommended. Aerobic pretreatment seems to be effective. On the other hand, no enhancement was observed in the case of the diluted wastewater.  相似文献   

18.
Sucralose, a chlorinated carbohydrate, has shown its increased use as an artificial sweetener and persistently exists in wastewater treatment plant effluents and aquatic environment. This paper aims to review possible degradation of sucralose and related carbohydrates by biological, electrochemical, chemical, and advanced oxidation processes. Biodegradation of sucralose in waterworks did not occur significantly. Electrochemical oxidation of carbohydrates may be applied to seek degradation of sucralose. The kinetics of the oxidation of sucralose and the related carbohydrates by different oxidative species is compared. Free chlorine, ozone, and ferrate did not show any potential to degrade sucralose in water. Advanced oxidation processes, generating highly strong oxidizing agent hydroxyl radicals (?OH), have demonstrated effectiveness in transforming sucralose in water. The mechanism of oxidation of sucralose by ?OH is briefly discussed.  相似文献   

19.
采用直接混凝、直接水解 -接触氧化的生化处理以及混凝 -水解 -接触氧化 3种不同工艺对某酶制剂废水进行处理。结果表明 ,针对浓度为 6 2 0 0mg/L的原水 ,用本单位的混凝剂 4号进行直接的混凝处理 ,在加入量为 10 0mg/L时可以得到 6 6 %的CODCr处理率 ;同样浓度的原水直接进行水解 -接触氧化生化处理 ,在 34h的停留时间后可以达到国家二类二级排放标准 ;经过混凝处理后的出水进行的生化实验则表明 ,达到国家排放标准的生化停留时间可缩短至 2 2h。  相似文献   

20.
The discharge of effluents and toxic compounds into aquatic systems represents a growing environmental problem involving an impact on water ecology and potential effect on human health. Most municipal wastewaters are complex mixtures; their complexity led as to carry out a hazard assessment using chemical analyses and biological tests.This study investigates biochemical alteratiobns in two sentinel organisms, the Anodonta cygnea mussel and the Xenopus laevis frog exposed for different lengths of time to various concentrartion of wastewater of the S. Antonino Ticino treatment plant. The results point out the long-life of toxic compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号