1.
The data mining/groundwater modeling methodology developed in McDade et al. (2013) was performed to determine if matrix diffusion is a plausible explanation for the lower‐concentration but persistent chlorinated solvent plumes in the groundwater‐bearing units at three different pump‐and‐treat systems. Capture‐zone maps were evaluated, and eight wells were identified that did not draw water from any of the historical source areas but captured water from the sides of the plume. Two groundwater models were applied to study the persistence of the plumes in the absence of contributions from the historical source zones. In the wells modeled, the observed mass discharge generally decreased by about one order of magnitude or less over 4 to 10 years of pumping, and 1.8 to 17 pore volumes were extracted. In five of the eight wells, the matrix diffusion model fit the data much better than the advection dispersion retardation model, indicating that matrix diffusion better explains the persistent plume. In the three other wells, confounding factors, such as a changing capture zone over time (caused by changes in pumping rates in adjacent extraction wells); potential interference from a high‐concentration unremediated source zone; and limited number of pore volumes removed made it difficult to confirm that matrix diffusion processes were active in these areas. Overall, the results from the five wells indicate that mass discharge rates from the pumping wells will continue to show a characteristic “long tail'' of mass removal from zones affected by active matrix diffusion processes. Future site management activities should include matrix diffusion processes in the conceptual site models for these three sites. © 2013 Wiley Periodicals, Inc.  相似文献   

2.
Groundwater tracing with fluorescent tracer dyes is a valuable tool in many remediation projects. Three of four common dyes can be used concurrently, effectively separated, and their concentrations quantified if modern laboratory instruments and appropriate protocols are used. Unfortunately, investigators often overestimate the amount of introduced dye likely to be detected, use too little dye because of these estimates and concern that colored water might be detectable off‐site, and place sampling reliance solely on grab samples of water. The common result is flawed studies that identify only some of the points to which the dyed water flows. Results are quantitatively compared for monitoring sites during periods where both water samples and granular activated carbon samplers (referred to as carbon samplers) were used. The results demonstrate that carbon samplers are superior to water samples for detecting the presence of the fluorescent tracer dyes evaluated. A technically sound and cost‐effective strategy is to place primary sampling reliance on carbon samplers for detecting the presence of the dyes and secondary reliance on grab samples of water for determining dye concentrations when they are greater than the detection limits.  相似文献   

3.
Despite the installation in the 1980s and 1990s of hydraulic containment systems around known source zones (four slurry walls and ten pump‐and‐treat systems), trichloroethene (TCE) plumes persist in the three uppermost groundwater‐bearing units at the Middlefield‐Ellis‐Whisman (MEW) Superfund Study Area in Mountain View, California. In analyzing TCE data from 15 recovery wells, the observed TCE mass discharge decreased less than an order of magnitude over a 10‐year period despite the removal of an average of 11 pore volumes of affected groundwater. Two groundwater models were applied to long‐term groundwater pump‐and‐treat data from 15 recovery wells to determine if matrix diffusion could explain the long‐term persistence of a TCE plume. The first model assumed that TCE concentrations in the plume are controlled only by advection, dispersion, and retardation (ADR model). The second model used a one‐dimensional diffusion equation in contact with two low‐permeability zones (i.e., upper and lower aquitard) to estimate the potential effects of matrix diffusion of TCE into and out of low‐permeability media in the plume. In all 15 wells, the matrix diffusion model fit the data much better than the ADR model (normalized root mean square error of 0.17 vs. 0.29; r2 of 0.99 vs. 0.19), indicating that matrix diffusion is a likely contributing factor to the persistence of the TCE plume in the non‐source‐capture zones of the MEW Study Area's groundwater‐extraction wells. © 2013 Wiley Periodicals, Inc.  相似文献   

4.
This article presents field tests comparing two methods of treatment of chlorinated solvents undertaken at the same site. The site is an automobile factory where two chlorinated solvents (CS) plumes were identified. At the first source, in situ chemical reduction (ISCR) was applied, while at the second one, enhanced natural attenuation (ENA) was used. A set of specific multilevel sampling wells were installed approximately 20 m downgradient of the sources to estimate the efficiency of the treatments. The presence of a low‐permeability layer (source 1) or a thick oil lens (source 2) in the top part of the aquifer prevented the CS from reaching the bottom of the aquifer. These layers led to difficulties treating the contamination. At the ISCR and ENA treatment zones, the concentrations of tetrachloroethene (PCE) and trichloroethene (TCE) did not change significantly, while the concentration of metabolites (cis‐1,2‐DCE, vinyl chloride, and ethene) significantly increased 50 to 150 days after treatment. Due to high concentration of CS in the source zone, a mass balance calculation, including chlorine, was possible. It showed that around 1 to 2 percent of the injected products were used to reduce the CS. A detailed analysis and 1D analytical modeling of CS concentrations showed that the treatment led to a large (two to three times) increase in dissolution of the organic phase. This explains why, despite an efficient treatment, the PCE and TCE concentrations remained virtually unchanged. Degradation rates also increased due to the treatment. Due to some differences in the source‐zone chemistry, it was not possible to differentiate between the ISCR and ENA efficiencies. © 2013 Wiley Periodicals, Inc.  相似文献   

5.
In the early 1990s, a soil removal action was completed at a former disposal pit site located in southern Michigan. This action removed waste oil, cutting oil, and chlorinated solvents from the unsaturated zone. To contain groundwater contaminant migration at the site, a groundwater pump‐and‐treat system comprised of two extraction wells operating at a combined flow of 50 gallons per minute, carbon treatment, and a permitted effluent discharge was designed, installed, and operated for over 10 years. Groundwater monitoring for natural attenuation parameters and contaminant attenuation modeling demonstrated natural attenuation of the contaminant plume was adequate to attain site closure. As a result of incomplete contaminant source removal, a rebound of contaminants above the levels established in the remedial action plan (RAP) has occurred in the years following system shutdown and site closure. Groundwater concentrations have raised concerns regarding potential indoor air quality at adjacent residential properties constructed in the past 9 to 10 years. The only remedial option available in the original RAP is to resume groundwater pump‐and‐treat. To remediate the source area, an alternate remediation strategy using an ozone sparge system was developed. The ozone sparge remediation strategy addresses the residual saturated zone contaminants beneath the former disposal pit and reestablishes site closure requirements without resumption of the pump‐and‐treat system. A pilot study was completed successfully; and the final system design was subsequently approved by the Michigan Department of Environmental Quality. The system was installed and began operations in July 2010. As of the January 2011 monitoring event, the system has shown dramatic improvement in site contaminant concentrations. The system will continue to operate until monitoring results indicate that complete treatment has been obtained. The site will have achieved the RAP objectives when the system has been shut down and meets groundwater residential criteria for four consecutive quarters. © 2011 Wiley Periodicals, Inc.  相似文献   

6.
Field‐scale pilot tests were performed to evaluate enhanced reductive dechlorination (ERD) of dissolved chlorinated solvents at a former manufacturing facility located in western North Carolina (the site). Results of the site assessment indicated the presence of two separate chlorinated solvent–contaminated groundwater plumes, located in the northern and southern portions of the site. The key chlorinated solvents found at the site include 1,1,2,2‐tetrachloroethane, trichloroethene, and chloroform. A special form of EHC® manufactured by Adventus Americas was used as an electron donor at this site. In this case, EHC is a pH‐buffering electron donor containing controlled release carbon and ZV Iron MicroSphere 200, a micronscale zero‐valent iron (ZVI) manufactured by BASF. Approximately 3,000 pounds of EHC were injected in two Geoprobe® boreholes in the saprolite zone (southern plume), and 3,500 pounds of EHC were injected at two locations in the partially weathered rock (PWR) zone (northern plume) using hydraulic fracturing techniques. Strong reducing conditions were established immediately after the EHC injection in nearby monitoring wells likely due to the reducing effects of ZV Microsphere 200. After approximately 26 months, the key chlorinated VOCs were reduced over 98 percent in one PWR well. Similarly, the key chlorinated solvent concentrations in the saprolite monitoring wells decreased 86 to 99 percent after initial increases in concentrations of the parent chlorinated solvents. The total organic carbon and metabolic acid concentrations indicated that the electron donor lasted over 26 months after injection in the saprolite aquifer. © 2009 Wiley Periodicals, Inc.  相似文献   

7.
In efforts to evaluate the use of plants as a forensic tool for delineating contaminated soil and groundwater, a laboratory experiment and a field sampling effort were undertaken. Site assessments are often costly and inaccurate, requiring multiple mobilizations to hone in on source areas and getting accurate estimates of contaminant extent and distribution. As these extensive site delineations take place, valuable time and resources are lost. The findings of this study show that plants can be used as a tool to evaluate a variety of subsurface contaminants, either in the vadose zone or in the saturated zone. In the first field application of Taproot? Technology, a large, heavily forested site was sampled in one day and the contamination on‐site was more accurately delineated than had been generated at the site in over a decade, with more than 26 wells installed. New source zones were detected on the site, and the presence of new waste depositions was uncovered for the first time showing the great value of tree coring as a contaminant detection tool. © 2009 Wiley Periodicals, Inc.  相似文献   

8.
Using a dual species methane/acetylene instrument based on cavity ring down spectroscopy (CRDS), the dynamic plume tracer dispersion method for quantifying the emission rate of methane was successfully tested in four measurement campaigns: (1) controlled methane and trace gas release with different trace gas configurations, (2) landfill with unknown emission source locations, (3) landfill with closely located emission sources, and (4) comparing with an Fourier transform infrared spectroscopy (FTIR) instrument using multiple trace gasses for source separation. The new real-time, high precision instrument can measure methane plumes more than 1.2 km away from small sources (about 5 kg h?1) in urban areas with a measurement frequency allowing plume crossing at normal driving speed. The method can be used for quantification of total methane emissions from diffuse area sources down to 1 kg per hour and can be used to quantify individual sources with the right choice of wind direction and road distance. The placement of the trace gas is important for obtaining correct quantification and uncertainty of up to 36% can be incurred when the trace gas is not co-located with the methane source. Measurements made at greater distances are less sensitive to errors in trace gas placement and model calculations showed an uncertainty of less than 5% in both urban and open-country for placing the trace gas 100 m from the source, when measurements were done more than 3 km away. Using the ratio of the integrated plume concentrations of tracer gas and methane gives the most reliable results for measurements at various distances to the source, compared to the ratio of the highest concentration in the plume, the direct concentration ratio and using a Gaussian plume model. Under suitable weather and road conditions, the CRDS system can quantify the emission from different sources located close to each other using only one kind of trace gas due to the high time resolution, while the FTIR system can measure multiple trace gasses but with a lower time resolution.  相似文献   

9.
The distribution of air around injection wells is an important determinant of the effectiveness, design, and cost of air sparging remediation systems. High-level air sparging field tests were conducted at two sites for the purpose of determining the pattern of airflow under widely different subsurface conditions. One site consisted of relatively homogeneous dune sand (Site A). The other consisted of highly heterogeneous glacial till (Site B). At both sites, cross-borehole electrical resistance tomography (ERT) was used to image the principal region of airflow in the saturated zone. The response of conventional monitoring data was compared with the ERT results. At Site A, the principal region of airflow was approximately symmetric about the sparge well and only 2.4 m in radius. At Site B, the pattern of airflow was much more complex and had a major horizontal component. In both site studies, conventional monitoring data provided a much more ambiguous indication of the region of airflow in the saturated zone than did ERT. The investigations at these two sites demonstrate that, while the exact distribution of injected air is not readily discernible by conventional monitoring, the character of the airflow pattern can be recognized when appropriate physical response data are collected. Such response data can be used to evaluate site suitability for air sparging and to improve the system design and operation.  相似文献   

10.
In situ treatability studies are being conducted to evaluate various in situ technologies to manage groundwater contamination at the NASA Marshall Space Flight Center in Huntsville, Alabama. The focus of these studies is to evaluate remediation options for contaminated (mostly aerobic) groundwater occurring within the basal portion of a clayey residuum called the rubble zone. The tension‐saturated media and unsaturated media lying above the rubble zone are also being treated where they make up a significant component of the contaminant mass. An in situ chemical reduction field pilot test was implemented (following bench‐scale tests) during July and August 2000. The test involved the injection of zero‐valent iron powder in slurry form, using the FeroxSM process patented by ARS Technologies, Inc. The pilot test focused on trichloroethene (TCE)‐contaminated groundwater within the rubble zone. Maximum pre‐injection concentrations of about 72,800 micrograms per liter (μg/l) were observed and no secondary sources are believed to exist beneath the area. The potential presence of unexploded ordnance forced an implementation strategy where source area injections were completed, as feasible, followed by overlapping injections in a down gradient alignment to create a permeable reactive zone for groundwater migration. Eight post‐injection rounds of groundwater performance monitoring were completed. The results are encouraging, in terms of predicted responses and decreasing trends in contaminant levels. © 2003 Wiley Periodicals, Inc.  相似文献   

11.
以沉淀一热解法制备了纳米级Co3O4催化剂,并用X射线衍射仪、红外光谱仪对Co3O4催化剂进行了表征。以300W高压汞灯为光源,研究了Co3O4催化剂对不同活性染料的光催化氧化活性。实验结果表明:在活性染料质量浓度为20mg/L、250mL染料溶液中Co3O4催化剂加入量为150mg、反应2h的条件下,Co3O4催化剂对B—GFF黑、B—RN蓝、K—NR艳蓝3种活性染料溶液的脱色率分别为95%,87%,77%;适当加入酸或碱有利于提高处理效率,反应后染料溶液的pH为7.12~8.37,染料溶液初始pH为10.00时的脱色率最高为100%;Co3O4催化剂具有一定的再利用价值。  相似文献   

12.
Air sparging is an innovative methodology for remediating organic compounds present in contaminated, saturated soil zones. In the application of the technology, sparging (injection) wells are used to inject a hydrocarbon-free gaseous medium (typically air) into the saturated zone below or within the areas of contamination. Two major mechanisms of remediation are engaged/enhanced due to the sparging process. First, volatile organic compounds are dissolved in the groundwater and sorbed on the soil partition into the advective air phase, effectively simulating an in-situ air stripping system. The stripped contaminants are transported in the air phase to the vadose zone, generally within the radius of influence of a standard vapor extraction and vapor treatment system. Second, with optimal environmental conditions, volatile and semivolatile organic compounds may be biodegraded by utilizing the sparging process to oxygenate the groundwater, thereby enhancing the growth and activity of the indigenous bacterial community. Air sparging is a complex multifluid phase process which has been applied successfully in Europe since the mid-1980s. Major design considerations include site geology, contaminant type, gas injection pressures and flow rates, injection interval (areal and vertical), and site-specific biofeasibility parameters. Site-specific geology and biofeasibility are the dominant design parameters. Pilot testing and full-scale design considerations should also be addressed. Mathematical models have been developed to simulate the air flow field during the sparging process and to examine the limitations imposed by site geology. Correct design and operation of this technology have been demonstrated to achieve groundwater cleanup to low part-per-billion contaminant levels. Incorrect design and operation can introduce significant pollution liability through undesirable contaminant migration in both the dissolved and vapor phases.  相似文献   

13.
It is difficult to quantify the range in source strength reduction (MdR) that may be attainable from in situ remediation of a dense nonaqueous‐phase liquid (DNAPL) site given that available studies typically report only the median MdR without providing insights into site complexity, which is often a governing factor. An empirical study of the performance of in situ remediation at a wide range of DNAPL‐contaminated sites determined MdRs for in situ bioremediation (EISB), in situ chemical oxidation (ISCO), and thermal treatment remedies. Median MdR, geometric mean MdR, and lower/upper 95 percent confidence interval for the mean were: 49x, 105x, 20x/556x, respectively, for EISB; 9x, 21x, and 4x/110x for ISCO; and 19x, 31x, and 6x/150x for thermal treatment. Lower MdR values were determined for large, complex sites and for sites with DNAPL pool‐dominated source zones. A feasibility analysis of partial DNAPL depletion is described for a pool‐dominated source zone. Back‐diffusion from low‐hydraulic conductivity units within a pool‐dominated source zone is shown to potentially sustain a secondary source for more than 1,000 years, indicating that aggressive source treatment may not reduce the remediation timeframe. Estimated plume response demonstrates there may be no reduction in cost associated with aggressive treatment, and little difference in risk reduction associated with the various alternatives. Monitored natural attenuation (MNA) for the source zone is shown to be a reasonable alternative for the pool‐dominated source zone considered in this example. It is demonstrated that pool‐dominated source zones with a large range in initial DNAPL mass (250 to 1,500 kg) may correspond to a narrow range in source strength (20 to 30 kg/year). This demonstrates that measured source strength is nonunique with respect to DNAPL mass in the subsurface and, thus, source strength should not be used as the sole basis for predicting how much DNAPL mass remains or must be removed to achieve a target goal. If aggressive source zone treatment is to be implemented due to regulatory requirements, strategic pump‐and‐treat is shown to be most cost effective. These remedial decisions are shown to be insensitive to a range of possible DNAPL pool conditions. At sites with an existing pump‐and‐treat system, a significant increase in mass removal and source strength reduction may be achieved for a low incremental cost by strategic placement of extraction wells and pumping rate selection. © 2014 Wiley Periodicals, Inc.  相似文献   

14.
Oxygen Release Compound (ORC®) is a patented formulation of intercalated magnesium peroxide that releases oxygen slowly when hydrated. ORC treatment represents a “low intensity” approach to site remediation. It provides a simple, passive, low-cost and long-term acceleration of aerobic natural attenuation and has been shown to cost-effectively reduce time to site closure. ORC is now a proven technology as evidenced by its five years of use on over 5,000 sites in 50 states and 11 countries, and the existence of a full body of independent, peer reviewed literature on its performance. The first applications of ORC were for the treatment of benzene, toulene, ethylbenzene, and xylene (BTEX) and other light petroleum hydrocarbon fractions. Use has now expanded to the treatment of heavier fractions such as heating oil and some of the Polycyclic aromatic hydrocarbons (PAHs). More recently. ORC has been used to bioremediate the highly mobile and problematic gasoline oxygenate methyl tertiary butyl ether (MTBE) and has been applied to sites impacted with nitroaromatics, chloroaromatics, and some of the lower-order chlorinated hydrocarbons that can be treated aerobically—most notably vinyl chloride. Since ORC is an insoluble powder, it can be packaged in material composed of a specially designed filter fabric. These “filter socks” are then contacted with contaminated groundwater via an array of wells or trenches. ORC can also be mixed directly with water to form a slurry for permanent injection applications in the saturated zone or dispersed in powdered form for the in-situ or ex-situ treatment of soil. A broad array of treatment points, in which ORC slurry is backfilled or injected, can be implemented with low-cost, small-bore push-point technologies to directly treat dissolved phase plumes and moderate levels of sorbed contaminants. Powder or slurry is traditionally used in the remediation of residual contamination at the bottom of contaminated soil excavations. © 1999 John Wiley & Sons, Inc.  相似文献   

15.
A survey of experts in the application of natural attenuation was conducted to better understand how monitored natural attenuation (MNA) is being applied at chlorinated solvent sites. Thirty‐four remediation professionals provided general information for 191 sites where MNA was evaluated, and site‐specific data for 45 chlorinated solvent plumes being remediated by MNA. Respondents indicated that MNA was precluded as a remedy at only 23 percent of all sites where evaluated as a remedial option. Leading factors excluding MNA as a remedial approach were the presence of an expanding plume and an unreasonably long estimated remediation time frame. MNA is being used as the sole remedy at about 30 percent of the sites, and 33 percent are implementing MNA in conjunction with source zone remediation. The remaining sites are implementing MNA with plume remediation (13 percent), source containment (9 percent), or some other strategy (16 percent). © 2004 Wiley Periodicals, Inc.  相似文献   

16.
Permeable reactive barriers made of zero‐valent iron (ZVI PRBs) have become a prominent remediation technology in addressing groundwater contamination by chlorinated solvents. Many ZVI PRBs have been installed across the United States, some as research projects, some at the pilot scale, and many at full scale. As a passive and in situ remediation technology, ZVI PRBs have many attractive features and advantages over other approaches to groundwater remediation. Ten ZVI PRBs installed in California were evaluated for their performance. Of those ten, three are discussed in greater detail to illustrate the complexities that arise when quantifying the performance of ZVI PRBs, and to provide comment on the national debate concerning the downgradient effects of source‐zone removal or treatment on plumes of contaminated groundwater. © 2009 Wiley Periodicals, Inc.  相似文献   

17.
EOS, or emulsified oil substrate, was used to stimulate anaerobic biodegradation of trichloroethene (TCE) and tetrachloroethene (PCE) at a former Army‐owned manufacturing facility located in the Piedmont area of North Carolina. Previous use of chlorinated solvents at the facility resulted in soil and groundwater impacts. Ten years of active remediation utilizing soil vacuum extraction and air sparging (SVE/AS) were largely ineffective in reducing the TCE/PCE plume. In 2002, the Army authorized preparation of an amended Remedial Action Plan (RAP) to evaluate in situ bioremediation methods to remediate TCE in groundwater. The RAP evaluated eight groundwater remediation technologies and recommended EOS as the preferred bioremediation alternative for the site. Eight wells were drilled within the 100 × 100 feet area believed to be the primary source area for the TCE plume. In a first injection phase, dilute EOS emulsion was injected into half of the wells. Distribution of the carbon substrate through the treatment zone was enhanced by pumping the four wells that were not injected and recirculating the extracted water through the injection wells. The process was repeated in a second phase that reversed the injection/extraction well pairs. Overall, 18,480 pounds of EOS were injected and 163,000 gallons of water were recirculated through the source area. Anaerobic groundwater conditions were observed shortly after injection with a corresponding decrease in both PCE and TCE concentrations. Dissolved oxygen, oxidation‐reduction potential, and sulfate concentrations also decreased after injection, while TCE‐degradation products, ferrous iron, and methane concentrations increased. The reduction in TCE allowed the Army to meet the groundwater remediation goals for the site. Approximately 18 months after injection, eight wells were innoculated with a commercially prepared dechlorinating culture (KB‐1) in an attempt to address lingering cis‐1,2‐dichloroethene (cis‐DCE) and vinyl chloride (VC) that continued to be observed in some wells. Dehalococcoides populations increased slightly post‐bioaugmentation. Both cis‐DCE and VC continue to slowly decrease. © 2007 Wiley Periodicals, Inc.  相似文献   

18.
The chemical recycling of cellulosic fibres may represent a next-generation fibre–fibre recycling system for cotton textiles, though remaining challenges include how to accommodate fibre blends, dyes, wrinkle-free finishes, and other impurities from finishing. These challenges may disrupt the regeneration process steps and reduce the fibre quality. This study examines the impact on regenerated viscose fibre properties of a novel alkaline/acid bleaching sequence to strip reactive dyes and dimethyloldihydroxyethyleneureas (DMDHEU) wrinkle-free finish from cotton textiles. Potentially, such a bleaching sequence could advantageously be integrated into the viscose process, reducing the costs and environmental impact of the product. The study investigates the spinning performance and mechanical properties (e.g., tenacity and elongation) of the regenerated viscose fibres. The alkaline/acid bleaching sequence was found to strip the reactive dye and DMDHEU wrinkle-free finish from the cotton fabric, so the resulting pulp could successfully be spun into viscose fibres, though the mechanical properties of these fibres were worse than those of commercial viscose fibres. This study finds that reactive dyes and DMDHEU wrinkle-free finish affect the viscose dope quality and the regeneration performance. The results might lead to progress in overcoming quality challenges in cellulosic chemical recycling.  相似文献   

19.
In June and July 2001, the Massachusetts Department of Environmental Protection (MassDEP) installed a permeable reactive barrier (PRB) to treat a groundwater plume of chlorinated solvents migrating from an electronics manufacturer in Needham, Massachusetts, toward the Town of Wellesley's Rosemary Valley wellfield. The primary contaminant of concern at the site is trichloroethene (TCE), which at the time had a maximum average concentration of approximately 300 micrograms per liter directly upgradient of the PRB. The PRB is composed of a mix of granular zero‐valent iron (ZVI) filings and sand with a pure‐iron thickness design along its length between 0.5 and 1.7 feet. The PRB was designed to intercept the entire overburden plume; a previous study had indicated that the contaminant flux in the bedrock was negligible. Groundwater samples have been collected from monitoring wells upgradient and downgradient of the PRB on a quarterly basis since installation of the PRB. Inorganic parameters, such as oxidation/reduction potential, dissolved oxygen, and pH, are also measured to determine stabilization during the sampling process. Review of the analytical data indicates that the PRB is significantly reducing TCE concentrations along its length. However, in two discrete locations, TCE concentrations show little decrease in the downgradient monitoring wells, particularly in the deep overburden. Data available for review include the organic and inorganic analytical data, slug test results from nearby bedrock and overburden wells, and upgradient and downgradient groundwater‐level information. These data aid in refining the conceptual site model for the PRB, evaluating its performance, and provide clues as to the reasons for the PRB's underperformance in certain locations. © 2008 Wiley Periodicals, Inc.  相似文献   

20.
Groundwater at most underground storage tank (UST) spills sites in Kansas contains both methyl tertiary butyl ethylene (MTBE) and benzene, and both contaminants must be effectively treated to close the sites. Soil vacuum extraction, air sparging, and excavation are the most common treatment technologies in Kansas. To compare the relative performance of these conventional remedial technologies for treating MTBE as compared to benzene, 66 sites in the Kansas UST Trust Fund were identified that had initial concentrations of both MTBE and benzene above the reporting limit of 1 μg/L, and that had at least two rounds of analytical data. Sites were excluded from the comparison if the monitoring wells had free product. Of the 66 sites, 15 had met the clean‐up goal for benzene, and 50 had met the goal for MTBE. The extent of treatment for MTBE and benzene was calculated as the ratio of the highest concentration in any well at the site in the most recent round of sampling to the maximum concentration in any well at the site in the previous rounds of sampling. The extent of treatment was greater for MTBE (statistically significant at p = 0.032). The geometric mean of the extent of treatment in the 66 sites was 0.057 for MTBE, compared to 0.14 for benzene. In Kansas, conventional technologies removed MTBE from the source areas of groundwater plumes at least as effectively as they removed benzene. © 2003 Wiley Periodicals, Inc.  相似文献   