首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This study examined the determination of BOD in landfill leachates by dilution (D-method) and manometric methods (M-method). The differences in results were discussed based on statistical tests. The effects of sample dilution, seeding, chloride and total Kjeldahl nitrogen (TKN) level were examined. The M-method was found to be more sensitive to increases in chloride and TKN concentrations. However, in the M-method the positive interference of nitrogenous BOD (NBOD) to carbonaceous BOD (CBOD) was more successfully prevented. The BOD rate constant k and the ultimate BOD (BODu) were estimated by non-linear regression. With the M-method these parameters could be more reliably estimated than the D-method. Suggestions were made for BOD analyses in landfill leachates in future studies.  相似文献   

2.
A number of microorganisms were isolated from sewage. Biochemical Oxygen Demand (BOD-5 day) analysis was carried out by individual pure cultures. The cultures giving higher or equal BOD values as compared to reference GGA solution were selected for the formulation of a defined mixed microbial consortium. This microbial consortium was co-immobilized on calcium-alginate beads. Four synthetic and six industrial samples were tested for BOD by using immobilized beads as well as sewage as source of seeding materials. BOD values obtained with beads for all the synthetic as well as industrial samples were fairly comparable with those obtained with sewage. Reusability of prepared microbial beads was also checked with different synthetic and industrial samples and was compared with reference GGA solution. The same microbial beads can be reused three times for different BOD-5 day estimations. It is recommended that immobilized microbial beads can be used as a ready-to-use seeding material for BOD analysis.  相似文献   

3.
适用于淡水的BOD测定仪已经成型,海水盐度高,BOD浓度低,测定仪样品传输及测量的精度和微生物传感器菌种的耐盐性,给构建海水BOD自动测定仪带来困难.以溶解氧电极微生物传感器法为基础,依据海水BOD测定的技术特点,分析样品传输系统、恒温系统和信号采集与处理系统的技术要求,并筛选耗氧耐盐菌种作为微生物传感器的菌株,构建了海水BOD测定仪.用该测定仪测定海水标样,测定结果与标准稀释法测定的BOD5具有良好的相关性和准确度.  相似文献   

4.
A framework for dissolved oxygen (DO) modeling of the Ravi River has been developed based on a combination of laboratory measurements and field and monitoring data. Both the classical Streeter-Phelps (CSP) and the modified Streeter-Phelps (MSP) models are used for DO simulations. The MSP model considers the carbonaceous biochemical oxygen demand (CBOD) and nitrogenous biochemical oxygen demand (NBOD) separately, whereas the CSP model is evaluated considering only the CBOD and NBOD is incorporated in the overall BOD utilization rate. CBOD, NBOD and BOD rates have been determined through long-term BOD analysis of five main wastewater outfalls and two surface drains discharging into the Ravi River over a 98 km stretch. Analysis by Thomas Method manifests strong coefficient of determination “R2” between 0.72 and 0.98 for all the three types of BOD rates. Sensitivity analyses have also been carried out to find out a suitable reaeration rate formula for highly variable flows in the Ravi River. The CSP model results based on classical approach of considering only CBOD show significant difference between the model predictions and field measurements suggesting that NBOD needs to be incorporated for the model development. The dissolved oxygen values calculated using the MSP model and the CSP model based on overall BOD rate are in close agreement with field measurements and are thus suitable to model DO levels in the Ravi River.  相似文献   

5.
Environmental monitoring of leachate quality from an open municipal solid waste dumping site in Tunceli, Turkey was studied in this research. The most commonly examined pollution parameters were determined on a seasonal basis. The annual average 5-day biological oxygen demand (BOD5) and chemical oxygen demand (COD) values of station points were measured as 70 and 425 mg/L, respectively, and also the average BOD5/COD ratio (a measure of biodegradability) was calculated as 0.20. The low ratio of biodegradability and slightly alkaline pH values in the leachate samples indicated that the site was characterized by methanogenic conditions. The mean ammonium-nitrogen (NH4 +-N) and corresponding phosphate (orthophosphate) values were assayed as 70 and 11 mg/L, respectively. The average solids content in the leachates was measured as 4,681 mg/L (total solids) and 144 mg/L (suspended solids). Very low concentrations of iron, manganese, copper, and zinc in the leachate samples were found and the concentration of cadmium was measured below detection limits. Excessive amount of nutrients and high organic and inorganic pollutant content in the leachates pose serious pollution potential to the environment. Since no drainage system or bio treatment exists in this open dumping site, high permeability of natural soil at the site and in the surrounding area and very fractured and crackled rocks under natural soil are indicators of high groundwater pollution potential in this site.  相似文献   

6.
This study assesses the efficiency of various physico-chemical, biological and other tertiary methods for treating leachate. An evaluation study on the treatability of the leachate from methane phase bed (MPB) reactor indicated that at an optimum hydraulic retention time of 6 days, the efficiency of the reactor in terms of biological oxygen demand (BOD) and chemical oxygen demand (COD) removal was 91.29 and 82.69%, respectively. Recycling of the treated leachate through the municipal solid waste layers in the leachate recycling unit (LRU) resulted in a significant increase in the biodegradation of organics present in the leachate. Optimum BOD and COD removal efficiencies were achieved at the third recycle; additional recycling of the leachate did not produce any significant improvement. Physico-chemical treatment of the leachate demonstrated that alum and lime (Option 2) were more economical than coagulants lime and MgCO3. A cost analysis of the economics of the various treatments revealed that the alternative treatment consisting of a MPB bed followed by a LRU and aerated lagoon is the most cost-effective treatment. However, the alternative consisting of a MPB followed by the LRU and a soil column, which is slightly more costly, would be the most appropriate treatment when adequate land is readily available.  相似文献   

7.
A biochemical oxygen demand (BOD) biosensor for effective and expeditious BOD(7) estimations was constructed and the non-steady phase of the output signal was extensively studied. The modelling approach introduced allows response curve reconstruction and a curve fitting procedure of good quality, resulting in parameters indicating the relationship between response and organic substrate concentration and stability properties of the BOD biosensor. Also, the immobilization matrixes of different thicknesses were characterized to determine their suitability for bio-sensing measurements in non-stationary conditions, as well as for the determination of the mechanical durability of the BOD biosensor in time. The non-steady response of the experimental output of the BOD biosensor was fitted according to the developed model that enables to determine the stability of the biosensor output and dependency on biodegradable organic substrate concentration. The calibration range of the studied BOD biosensor in OECD synthetic wastewater was 15-110 mg O(2) L(-1). Repeatability tests showed relative standard deviation (RSD) values of 2.8% and 5.8% for the parameter τ(d), characterizing the transient output of the amperometric oxygen sensor in time, and τ(s), describing the dependency of the transient response of the BOD biosensor on organic substrate concentration, respectively. BOD biosensor experiments for the evaluation of the biochemical oxygen demand of easily degradable and refractory municipal wastewater showed good concurrence with traditional BOD(7) analysis.  相似文献   

8.
In present study focus has been given on estimating quality and toxicity of waste with respect to heavy metals and its impact on groundwater quality, using statistical and empirical relationships between different hydrochemical data, so that easy monitoring may be possible which in turn help the sustainable management of landfill site and municipal solid waste. Samples of solid waste, leachate and groundwater were analyzed to evaluate the impact of leachates on groundwater through the comparison of their hydrochemical nature. Results suggest the existence of an empirical relationship between some specific indicator parameters like heavy metals of all three above mentioned sample type. Further, K/Mg ratio also indicates three groundwater samples heavily impacted from leachate contamination. A good number of samples are also showing higher values for and Pb than that of World Health Organization (WHO) drinking water regulation. Predominance of Fe and Zn in both groundwater and solid waste samples may be due to metal plating industries in the area. Factor analysis is used as a tool to explain observed relation between numerous variables in term of simpler relation, which may help to deduce the strength of relation. Positive loading of most of the factors for heavy metal clearly shows landfill impact on ground water quality especially along the hydraulic gradient. Cluster analysis, further substantiates the impact of landfill. Two major groups of samples obtained from cluster analysis suggest that one group comprises samples that are severely under the influence of landfill and contaminated leachates along the groundwater flow direction while other assorted with samples without having such influence.  相似文献   

9.
This study covers a thorough characterisation of landfill leachates emerging from a sanitary landfill area. The landfill leachates were obtained in the acidic stage of landfill stabilisation. Their organic content was high as reflected by the high BOD5 (5 day biological oxygen demand) and COD (chemical oxygen demand) values. They were also highly polluted in terms of the parameters TKN (total Kjeldahl nitrogen), NH4-N, alkalinity, hardness and heavy metals. Nickel was present in these wastewaters at a significant concentration. With regard to the high heavy metal content of these wastewaters, several physicochemical removal alternatives for the heavy metals Cu, Pb, Zn, Ni, Cd, Cr, Mn and Fe were tested using coagulation, flocculation, precipitation, base addition and aeration. Additionally, COD removal and ammonia stripping were examined. Co-precipitation with either alum or iron salts did not usually lead to significantly higher heavy metal removal than lime alone. The major methods leading to an effective heavy metal removal were aeration and lime addition. Nickel and cadmium seemed to be strongly complexed and were not removed by any method. Also lead removal proved to be difficult. The results are also discussed in terms of compliance with standards.  相似文献   

10.
A 5-day biochemical oxygen demand (BOD(5)) test has been used as the standard measurement of organic pollution in rivers worldwide. However, it may be argued that BOD is not a sufficient indicator of organic pollution when nitrogenous biochemical oxygen demand (NBOD) is present in water samples. In this study, BOD, NBOD, and carbonaceous biochemical oxygen demand (CBOD) of treated sewage effluent (TSE) were measured near at the discharge outlet of 3 sewage treatment plants (STPs) in Sakai, Itachi, and Kashio rivers in Central Japan. Additional measurements were conducted at one point upstream and two points downstream from the STP discharge points in the rivers. It was estimated that NBOD values in the TSE of Sakai River, Kashio River and Itachi River accounted for 54%, 69% and 18% of their BOD values, respectively. Respective NH4+ and NO2- concentrations were positively correlated with those of NBOD values in Sakai, Itachi, and Kashio rivers. The BOD loads from the TSE were estimated to be 2.2, 5.7, and 1.2 times higher than the CBOD loads in the Sakai, Itachi, and Kashio rivers, respectively. The variation of the portion of NBOD values of each TSE, as well as the ratios of CBOD to BOD loads, was attributed to the difference in each STP system. Consequently, the NH4+ and NO2- of TSE led to the increase of NBOD in the Sakai River basin.  相似文献   

11.
Water quality and bacterial diversity in the surface water of Rawal Lake was investigated for a period of 8 months to evaluate the pollution load from anthropogenic effects of surrounding areas. Rawal Lake in Islamabad, Pakistan is an artificial reservoir that provides the water needs for the residents of Rawalpindi and Islamabad. Grabbed water samples were collected according to standard protocols from ten different locations of the lake and tributaries keeping in view the recharge points from adjacent areas. Temperature, pH, electrical conductivity, dissolved oxygen, total dissolved solids, hardness, alkalinity, and turbidity of water samples were determined to study the water quality characteristics. The physicochemical parameters showed higher values at the tributaries as compared to the sampling locations within the lake such as values of hardness and alkalinity were 298 and 244 mg/L, respectively, at the tributary of the Nurpur stream. Bacterial strains were isolated by streaking on differential and selective growth media by observing colony morphology and other biochemical tests such as Gram reaction, oxidase, and catalase test. Template DNA was prepared from pure cultivated bacteria and 16S rRNA gene analysis was performed using universal primers for bacteria. Sequencing was performed by using BigDye terminator cycle sequencing kit. Sequences of nearest relative microbial species were identified by using basic local alignment search tool and used as reference sequences for phylogenetic analysis. Phylogenetic trees were inferred using the neighbor-joining method. Sequencing and phylogenetic characterization of microbes showed various phylotypes, of which Firmicutes, Teobacteria, and Proteobacteria were predominant.  相似文献   

12.
Several combinations of binders and absorbent additives were utilized to solidify a typical organic waste, API Separator sludge. The effectiveness of the materials was based on the waste leachability from the solidified samples. COD and TOC analyses were used to determine the organic content of the leachate samples.The ability of the COD and TOC analyses to assess waste leachability was limited. The inability of the COD and TOC tests to differentiate between organic compounds made the results difficult to interpret. This was due to organic contaminants from the solidification materials contributing to the COD and TOC contents of the leachates. Also, the COD test may have be influenced by reduced inorganic compounds contained in the flyash binder and the sludge. Representative samples for the TOC analysis were difficult to obtain for the leachates containing oils or suspended particles. It is recommended that the COD and TOC tests only be used as a screening method for determining solidified organic waste leachability and other methods need to be employed to obtain more accurate results.  相似文献   

13.
Due to the complex nature of landfill leachates, metal and metalloid analyses prove to be tricky and suffer from a lack of standard protocols. A complete approach has been adopted to investigate the influence of the different steps during the sample processing of French landfill leachates. The validation of the entire protocol has been achieved using a laboratory reference material. This material, which is a real landfill leachate, is representative of real samples. Its evaluation has allowed a quality control for metal and metalloid analyses in landfill leachates. Precautions concerning storage temperature, aeration and filtration are proposed to perform accurate metal analyses in these complex matrices. The sample processing has been applied to the seasonal monitoring of a French landfill. The assessment of major leachate metallic contaminants such as As, Cr, Sb, Sn, has been performed by evaluating the relative enrichment of metals and metalloids in comparison with rain water and groundwater. In addition, hydrological data are useful and complementary information for pointing out the main factors affecting metal concentrations and thus their potential remobilisation pathways.  相似文献   

14.
The attenuation of arsenic in groundwater near alkaline coal fly ash disposal facilities was evaluated by determining the uptake of arsenic from ash leachates by surrounding alkaline soils. Ten different alkaline soils near a retired coal fly ash impoundment were used in this study with pH ranging from 7.6 to 9.0, while representative coal fly ash samples from two different locations in the coal fly ash impoundment were used to produce two alkaline ash leachates with pH 7.4 and 8.2. The arsenic found in the ash leachates was present as arsenate [As(V)]. Adsorption isotherm experiments were carried out to determine the adsorption parameters required for predicting the uptake of arsenic from the ash leachates. For all soils and leachates, the adsorption of arsenic followed the Langmuir and Freundlich equations, indicative of the favorable adsorption of arsenic from leachates onto all soils. The uptake of arsenic was evaluated as a function of ash leachate characteristics and the soil components. The uptake of arsenic from alkaline ash leachates, which occurred mainly as calcium hydrogen arsenate, increased with increasing clay fraction of soil and with increasing soil organic matter of the alkaline soils. Appreciable uptake of arsenic from alkaline ash leachates with different pH and arsenic concentration was observed for the alkaline soils, thus attenuating the contamination of groundwater downstream of the retired coal fly ash impoundment.  相似文献   

15.
In order to promote pollutant monitoring and preservation of water resources, we evaluate the spatiotemporal trends in recent water quality conditions in Japanese rivers. Trend analysis is conducted on the 92 major rivers in Japan using the available water quality data recorded from 1992 to 2005 and the characteristics of major pollutants in these rivers are analyzed. Spatial and temporal analysis of trends for six water quality indicators is conducted using the Mann Kendall test, a non-parametric statistical method. The indicators analyzed are biochemical oxygen demand (BOD), chemical oxygen demand (COD), dissolved oxygen (DO), total nitrogen (TN), total phosphorus (TP) and pH. The majority of sampling locations monitoring BOD, COD, TN and TP show trends toward decreasing concentrations over time. Many sampling locations show increasing DO concentrations. Our results show that water quality in Japanese rivers has improved dramatically over the past decade, although there are still problems in some places, most notably in the Hokkaido, Kanto, Kinki and Kyushu regions. The improvements seen in water quality appear to be the result of improved wastewater treatment and other water quality improvement efforts achieved through government initiative.  相似文献   

16.
A biochemical oxygen demand (BOD) monitoring system, based on electrochemically-active bacteria in combination with a microbial fuel cell, has been developed for the purpose of on-site, on-line and real-time monitoring of practical wastewater. A microbial fuel cell that had been enriched with electrochemically-active bacteria was used as the basis of the measurement system. When synthetic wastewater was fed to the system, the current generation pattern and its Coulombic yield were found to be dependent on the BOD5 of the synthetic wastewater. A linear correlation between the Coulombic yields and the BOD5 of the synthetic wastewater were established. Real wastewater obtained from a sewage treatment plant also produced a highly linear correlation between the Coulombic yield and BOD5 in the system. To examine on-site, on-line and real-time monitoring capability, the BOD monitoring system was installed at a sewage treatment plant. Over 60 days, the measurement system was successfully operated with high accuracy and good stability with the measuring period for a sample being 45 min. This application showed that the application of the measurement system was a rapid and practical way for the determination of BOD5 in water industries.  相似文献   

17.
In this paper limnological status of river Suswa was observed for a period of two years. A water quality Beck modified Khanna Bhutiani model (BMKB model) was developed to calculate DO (dissolved Oxygen) and BOD (biochemical oxygen demand). The model was developed to calculate DO and BOD by using DO/BOD of same place and upstream in previous season which results in Single output. This model gives the seasonal value on the basis of previously taken upstream and downstream observations/concentrations of DO and BOD. The model was calibrated and verified for the water quality data (Physico-chemical data) of samples collected from river Suswa in different seasons. The model gave good agreement between data observed by it and the data observed manually, thus substantiating the validity of the model. Only minor differences were observed in physical, chemical and heavy metals of all the four sampling stations during the course of study.  相似文献   

18.
The work describes the physicochemical analysis of the water samples collected from Lahore Canal to evaluate pollution load at different points of the canal. Different physical and chemical pollutants such as temperature, pH, electrical conductivity, total dissolved and suspended solids, turbidity, chlorides, sulphates, nitrates, oils and grease, dissolved oxygen, chemical oxygen demand and biological oxygen demand (BOD) were analysed. The data was analysed through analysis of variance, which showed that the p values for dissolved oxygen (DO), chemical oxygen demand (COD), BOD, electrical conductivity, total dissolved solid (TDS), total suspended solid (TSS), turbidity, oil and grease, sulphates, and nitrates are <0.05, while p value of temperature, pH, and chlorides are 1.000, 0.984, and 0.070, respectively, which are >0.05. Further regression analysis revealed that the simple line regression modal is fit for turbidity and TSS, electrical conductivity and TDS, COD and DO, BOD and DO, and BOD and COD. The studies reveal that Lahore Canal is receiving a considerable amount of physical and chemical pollutants at different points.  相似文献   

19.
地表水BOD_5的快速预测预报   总被引:1,自引:0,他引:1  
地表水五日生化需氧量(BOD5)的测试需要五天时间,分析周期较长。本文建立了BOD5与高锰酸盐指数(CODMn)、BOD5与溶解氧(DO)之间的直线回归方程,通过测定地表水的CODMn和DO可分别对地表水的BOD5实现快速预测预报。现场使用溶解氧测定仪检测DO,可立即预报地表水的BOD5。  相似文献   

20.
对大量不同行业和水样的实际样品进行BOD微生物传感器快速测定法与五日生化需氧量法(BOD5)的比对分析,在此基础上,指出了BOD快速测定法的注意事项以及应用范围.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号